Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat transfer and core neutronics considerations of the heat pipe cooled thermionic reactor

The authors summarize the results of detailed neutronic and thermal-hydraulic evaluations of the heat pipe cooled thermionic (HPTI) reactor design, identify its key design attributes, and quantify its performance characteristics. The HPTI core uses modular, liquid-metal core heat transfer assemblies to replace the liquid-metal heat transport loop employed by in-core thermionic reactor designs of the past. The nuclear fuel, power conversion, heat transport, and heat rejection functions are all combined into a single modular unit. The reactor/converter assembly uses UN fuel pins to obtain a critical core configuration with in-core safety rods and reflector controls added to complete the subassembly. By thermally bonding the core heat transfer assemblies during the reactor core is coupled neutronically, thermally, and electrically into a modular assembly of individual power sources with cross-tied architecture. A forward-facing heat pipe radiator assembly extends from the reactor head in the shape of a frustum of a cone on the opposite side of the power system from the payload. Important virtues of the concept are the absence of any single-point failures and the ability of the core to effectively transfer the TFE waste heat load laterally to other in-core heat transfer assemblies in the event of multiple failures in either in-core and radiator heat pipes.

Determan, W. R.↗

Aeroheating Predictions for the X-43 Cowl-Closed Configuration at Mach 7 and 10

A pre-flight analysis was conducted for the Mach 7 and Mach 10 X-43 cowl-closed configurations to evaluate three-dimensional flow-field effects on localized heating in the vicinity of the closed cowl flap and sidewall. First, engineering-level analyses based on documented laminar and turbulent surface heating database were used to estimate localized heating amplification factors to account for turbulent flow effects, corner flow effects and the presence of forebody boundary layer trip devices. These estimated factors were applied to 2-D computational predictions to develop surface heat loads. Second, thin-film gauge surface heating data were obtained for a Mach 10 cowl-closed configuration in a reflected shock tunnel at simulated flight conditions. Third, computational fluid dynamics (CFD) flow-field predictions were obtained at Mach 10 ground test conditions to provide comparisons with the engineering database predictions and experimental measurements. Similarly, a CFD solution was also obtained at Mach 7 flight conditions to provide qualitative comparisons with engineering predictions. The Mach 10 CFD predictions compare favorably with the experimental measurements and the engineering estimates for surface heating amplification on the closed cowl. However, experimental measurements were not of sufficient quantity on the sidewall surface to capture the highest localized heating rates, and also the Mach 10 CFD predictions suggest higher peak heating on the sidewall compared to the engineering estimates. Also, the Mach 7 CFD predictions indicate qualitative agreement with the database estimates in terms of flow-field structure and peak heating locations on the closed-cowl flap and sidewall surfaces.

Cockrell, Charles E., Jr.↗

Working Fluids for Increasing Capacities of Heat Pipes

A theoretical and experimental investigation has shown that the capacities of heat pipes can be increased through suitable reformulation of their working fluids. The surface tensions of all of the working fluids heretofore used in heat pipes decrease with temperature. As explained in more detail below, the limits on the performance of a heat pipe are associated with the decrease in the surface tension of the working fluid with temperature, and so one can enhance performance by reformulating the working fluid so that its surface tension increases with temperature. This improvement is applicable to almost any kind of heat pipe in almost any environment. The heat-transfer capacity of a heat pipe in its normal operating-temperature range is subject to a capillary limit and a boiling limit. Both of these limits are associated with the temperature dependence of surface tension of the working fluid. In the case of a traditional working fluid, the decrease in surface tension with temperature causes a body of the liquid phase of the working fluid to move toward a region of lower temperature, thus preventing the desired spreading of the liquid in the heated portion of the heat pipe. As a result, the available capillary-pressure pumping head decreases as the temperature of the evaporator end of the heat pipe increases, and operation becomes unstable. Water has widely been used as a working fluid in heat pipes. Because the surface tension of water decreases with increasing temperature, the heat loads and other aspects of performance of heat pipes that contain water are limited. Dilute aqueous solutions of long-chain alcohols have shown promise as substitutes for water that can offer improved performance, because these solutions exhibit unusual surface-tension characteristics: Experiments have shown that in the cases of an aqueous solution of an alcohol, the molecules of which contain chains of more than four carbon atoms, the surface tension increases with temperature when the temperature exceeds a certain value. There are also other liquids that have surface tensions that increase with temperature and could be used as working fluids in heat pipes. For example, as a substitute for ammonia, which is the working fluid in some heat pipes, one could use a solution of ammonia and an ionic surfactant.

Chao, David F.↗

Backshell Radiation Analysis with US3D

During atmospheric entry, radiative heat flux can be a dominant heat transfer mechanism acting on the after-body of the space vehicle. Though the magnitude of radiative heat flux is small, the materials used on the back shell are designed to accommodate smaller heat loads. Therefore, an accurate estimation of radiative heat flux is required. For MSL, Brandis et al.1 performed radiation analysis on the afterbody of the vehicle. They used full angular integration to accurately calculate the radiative heat flux at multiple body points. The above analysis was performed on structured CFD solutions, and the present work applies the same type of analysis to unstructured solutions using US3D.

Raghava S C Davuluri↗

Built-in Thermionic Electron Source for an SRF Linacs

The design of a thermionic electron source connected directly to a superconducting cavity, the key part of an SRF gun, is described. The results of beam dynamics optimization are presented which allow lack of beam current intercepting in the superconducting cavity. The electron source concept is presented including the cathode-grid assembly, thermal insulation of the cathode from the cavity, and the gun resonator design. The cavity thermal load caused by the gun is analyzed including the static heat load, black body radiation, backward electron heating, etc.

43 PARTICLE ACCELERATORS↗

Intermittency Model for Coupled CFD-Stability Transition Analysis in Hypersonic Flow

Accurate prediction of aerothermodynamic loads on hypersonic vehicles requires precise modeling of surface quantities across the boundary layer transition zone. The peak heating loads and total heat transfer are determined by parameters such as the transition zone length and the magnitude of potential overshoots in heat flux and skin friction beyond their respective values in fully turbulent flows. While previous studies on CFD integrated transition modeling using linear stability correlations have shown promise in modeling these features, they did not develop an intermittency model for hypersonic flows. This paper presents a data-driven approach to develop a model of this type by correlating experimental transition data with the relevant flow parameters. The resulting model demonstrates significant improvements over previous low-speed models in terms of predicting heat transfer distributions during the transition process associated with first and second mode instabilities in axisymmetric high-speed flows. Separate correlations for flight and ground test conditions are developed, and the potential to combine these correlations is discussed.

Transition↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

A Simplified Approach for the Rapid Generation of Transient Heat-Shield Environments

A simplified approach has been developed whereby transient entry heating environments are reliably predicted based upon a limited set of benchmark radiative and convective solutions. Heating, pressure and shear-stress levels, non-dimensionalized by an appropriate parameter at each benchmark condition are applied throughout the entry profile. This approach was shown to be valid based on the observation that the fully catalytic, laminar distributions examined were relatively insensitive to altitude as well as velocity throughout the regime of significant heating. In order to establish a best prediction by which to judge the results that can be obtained using a very limited benchmark set, predictions based on a series of benchmark cases along a trajectory are used. Solutions which rely only on the limited benchmark set, ideally in the neighborhood of peak heating, are compared against the resultant transient heating rates and total heat loads from the best prediction. Predictions based on using two or fewer benchmark cases at or near the trajectory peak heating condition, yielded results to within 5-10 percent of the best predictions. Thus, the method provides transient heating environments over the heat-shield face with sufficient resolution and accuracy for thermal protection system design and also offers a significant capability to perform rapid trade studies such as the effect of different trajectories, atmospheres, or trim angle of attack, on convective and radiative heating rates and loads, pressure, and shear-stress levels.

Wurster, Kathryn E.↗

Liquid lithium as divertor material to mitigate severe damage of nearby components during plasma transients

The successful operation of thermonuclear fusion reactors such as ITER, DEMO, and future commercial plants is mainly determined by the optimum choice of materials for various components. The objective of this work is to accurately and comprehensively simulate the entire device in 3D to predict pros and cons of various materials, e.g., liquid lithium in comparison to tungsten and carbon to predict future ITER-like and DEMO divertor performances. We used our comprehensive HEIGHTS simulation package to investigate ITER-like components response during transient events in exact 3D geometry. Starting from the lost hot core plasma particles through SOL, deposition on the divertor surface, and the generation of secondary plasma of divertor materials. Our simulations predicted significant reduction in the heat loading and damage to the divertor nearby and internal components in the case when lithium is used on the divertor plates. While if tungsten or carbon are used on the divertor plate, significant melting areas and vaporization spots can occur (less for carbon) on the reflector, dome, and stainless steel tubes, and even parts of the first walls can melt due to the high radiation power of the secondary divertor plasma. Lithium photon radiation deposition into the divertor and nearby surfaces was decreased by two orders of magnitude compared to tungsten and by one order of magnitude compared to carbon. This analysis showed that using liquid lithium for ITER-like surfaces and future DEMO can lead to significant enhancement in components lifetime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pilgrim Hot Springs Building Dimensions and Energy Modeling

This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern buildings (Caretaker's Cabin, Igloo, Visitor's Cabin, Staff Shower Hut), and planned building projects (Changing Room, Greenhouse). Modeling results were used to determine feasible geothermal system typologies. The previous study linked below ("Village of Solomon Development of Energy Efficiency Building Standards for New Construction") feeds in to this project. The dataset includes DWG drawings and AKwarm energy models (.hm2) of a subset of existing buildings at the site of Pilgrim Hot Springs. All buildings were modeled in their current state, and some were additionally modeled with improvements to the building envelope. Energy modeling results exported from AKwarm include .htm and .png images.

AKwarm↗

Modeling of thermal pressurization in tight claystone using sequential THM coupling: Benchmarking and validation against in-situ heating experiments in COx claystone

We apply thermoporoelasticity and a sequentially coupling technique for modeling thermally-driven coupled Thermo-Hydro-Mechanical (THM) processes in tight claystone. A THM benchmark case with a corresponding analytic solution for thermoporoelasticity under a constant heat loading verifies the model. Thereafter, two in situ heating experiments are simulated for model validation: a smaller-scale heating experiment (TED experiment) and a larger-scale experiment (ALC experiment) in Callovo-Oxfordian (COx) claystone at the Meuse/Haute-Marne underground research laboratory in France. The model exhibits good performance to match the observed temperature and pore pressure evolution for the smaller-scale TED experiment. For the larger-scale ALC experiment, general trends of thermal-pressurization are captured in the modeling, but pressure is underestimated at some monitoring points during cool-down. This indicates that the THM response in the field may be affected by the variability of rock's properties or irreversible or time-dependent mechanical processes that are not included in the current thermoporoelastic model. The main contributions of this work are as follows: (1) we verify and validate the numerical simulator, TOUGH-FLAC, to be a valuable coupled THM modeling tool; (2) prove that the laboratory determined material parameters can be used as reference values for upscaling experiments. However, to better identify and quantify THM processes with modeling of in situ tests, more emphasize should be dedicated to obtaining high-quality mechanical deformation data.

58 GEOSCIENCES↗

Internal convective cooling systems for hypersonic aircraft

Parametric studies were conducted to investigate the relative merits of construction materials, coolants, and cooled panel concepts for internal convective cooling systems applied to airframe structures of hydrogen-fueled hypersonic aircraft. These parametric studies were then used as a means of comparing various cooled structural arrangements for a hypersonic transport and a hypersonic research airplane. The cooled airplane studies emphasized weight aspects as related to the choice of materials, structural arrangements, structural temperatures, and matching of the cooling system heat load to the available hydrogen fuel-flow heat sink. Consideration was given to reliability and to fatigue and fracture aspects, as well. Even when auxiliary thermal protection system items such as heat shielding, insulation, and excess hydrogen for cooling are considered the more attractive actively cooled airframe concepts indicated potential payload increases of from 40 percent to over 100 percent for the hypersonic transport as compared to the results of previous studies of the same vehicle configuration with an uncooled airframe.

Anthony, F. M.↗

Analysis of Heat Transfer from Local Heating and Cooling Sources at Cryogenic Temperatures

Understanding the dispersion of heat around a cryogenic fluid tank, specifically the interaction between the cryogenic fluid and the tank wall is critical in the analysis of long duration cryogen storage in microgravity. The heat transfer interaction between a cryogenic storage tank and heat sources from external spacecraft structures is also one of the many factors that determine how much heat enters a tank. Recent flight experiments with two-phase fluids have indicated that local concentrations of heat input (also known as “hot spots”) can cause unwanted affects including local boiling. Computational fluid dynamic (CFD) models can provide a detailed assessment of the heat transfer occurring across a cryogenic storage system. However, CFD modeling takes time to construct and run. A simpler approach that can act as initial guidance for later CFD modeling analyzes external “hot spots” as point or finite heat sources. A radial, finite element network or a local direct solution can effectively estimate the heat spread across a cryogenic storage tank by calculating the temperature and heat load as a function of distance from the heat source. This calculation accounts for the convective heat transfer between the cryogenic fluid and storage tank surface. Similar approaches can be used to determine the effectiveness of cooling from a cryocooler as a finite, local heat sink. This approach allows for quick approximations of the thermal map across a cryogenic tank as well as sensitivity analysis under a wide range of design parameters including gravitational fields as implied through natural convection coefficients.

Cryogenic Fluid Management↗

Uranus Probe Entry and Descent Mission Concept

Introduction: Uranus was identified as the third highest priority flagship mission in the 2012-2022 Planetary Science Decadal Survey. This latest concept study was requested by the Decadal Survey panel to determine NASA’s planetary science priorities from 2022-2032. This study focused on the probe’s entry and descent aspects and associated trades for viable trajectory options. Uranus Mission and Descent Probe: The proposed Uranus Orbiter and Probe (UOP) Flagship mission will investigate Uranus and its surrounding moons using an orbiting spacecraft with a Uranus descent probe. Unlike previous studies the probe release will occur after orbit insertion allowing sufficient separation of critical events during the orbit insertion burn. The probe will be released at an altitude that allows one hour of in situ atmospheric readings that will be relayed to the orbiter. Afterwards the orbiter will transition to the moon tour phase of the mission. The configuration chosen for the entry aeroshell was a 45° sphere-cone. This shape has been used in the past in the Pioneer Venus Galileo missions. However, the nose radius considered in the present study differed from the values used in either of the previous configurations, primarily to reduce the heat flux at the stagnation point. A two-step approach was used in the development of flight trajectories for the chosen configuration. In the first step, the trajectory code POST2 was used to screen the thousands of entry states provided by interplanetary trajectory simulations, which were terminated at an altitude of 2000 km from the reference surface (1 bar) of Uranus. The screening criteria were: (i) optimization of the communication geometry between the entry probe and orbiter to ensure at least 1 hour of science measurements, (ii) peak stagnation point pressures to be less than six bar, (iii) peak heat fluxes to be less than 5 kW/cm2; the latter two constraints being the limits of ground-test capabilities of the arc jets at NASA Ames Research Center. The entry team investigated two trajectories that met the criteria above, a shallow entry (high heat load ~44 kJ/cm2) and a steeper entry (high heat rate ~1950 W/cm2). In the second step, the two bounding candidate entry states from the POST2 screening process were used in developing flight trajectories using TRAJ coupled with FIAT (a materials thermal response and sizing code) and a margins policy to determine a margined uniform thickness (hence mass) of the forward heatshield material based on the aerothermal environments at the stagnation point. Since the combination of TRAJ and FIAT size the TPS based on stagnation point environments only, flow field computations using DPLR were necessary to determine turbulent aerothermal environments on the conical flank, and the augmentation of these environments due to surface roughness. The environments at select locations on the forward heatshield were then used to size the thermal protection material, with the largest thickness value then used to estimate the mass. The newly developed woven thermal protection material –HEEET (Heatshield for Extreme Entry Environments Technology) –was considered for the forward heatshield and PICA (Phenolic-Impregnated Carbon Ablator) was considered for the backshell. These NASA-developed materials are at TRL 6 and TRL 9, respectively. Furthermore, two options were considered for the HEEET material: (i) a dual-layer option with a denser recession layer on top and an insulative layer underneath it, and (ii) a single layer option consisting of the insulative layer alone. Results: It is clear that probe entry states are feasible and the selected TPS options are able to perform in the predicted aerothermal environments thus enabling the mission to meet of the descent probe portion of this flagship mission

Entry Descent and Landing↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Design and testing of a passive, feedback-controlled, variable conductance heat pipe

A passive feedback system, which stabilizes the heat source temperature (T sub s) of a gas loaded heat pipe, was designed and tested. The control of T sub s is accomplished by an auxiliary liquid that senses the heat source and actuates a metal bellows system due to the liquid's thermal expansion. The movement of the bellows varies the gas reservoir volume and leads to a corresponding change of the condensation area of the heat pipe. With methanol as the heat pipe working fluid and perfluoro-n-pentane as the auxiliary liquid, the control capability was found to be T sub s = 31.5 + or - 1.5 C in a power range from 3 to 30 W, compared to T sub s = 33 + or - 3 C with methanol as auxiliary liquid. The change in T sub s was 35 + or - 5.5 C with the bellows held in the closed position.

Schlitt, K. R.↗