Search NASA⌕ Search

SEARCH · Search NASA

Results for “high field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Multiphysics Simulations of Thermal Shock Testing of Nanofibrous High Power Targets

Increase of primary beam power for neutrino beam-lines leads to a reduced lifespan for production targets. New concepts for robust targets are emerging from the field of High Power Targetry (HPT); one idea being investigated by the HPT R&D Group at Fermilab is an electrospun nanofiber target. As part of their evaluation, samples with different densities were sent to the HiRadMat facility at CERN for thermal shock tests. The samples with the higher density, irradiated under a high intensity beam pulse, exhibit major damage at the impact site whereas those with the lower density show no apparent damage. The exact cause of this failure was unclear at the time. In this paper, we present the results of multiphysics simulations of the thermal shock experienced by the nanofiber targets that suggest the failure originates from the reduced permeability of the high density sample to air flow. The air present in the porous target expands due to heating from the beam, but is unable to flow freely in the high density sample, resulting in a larger back pressure that blows apart the nanofiber mat. We close with a discussion on how to further validate this hypothesis.

43 PARTICLE ACCELERATORS↗

Upgraded Near-Field Antenna-Testing System

Upgraded system for near-field testing of large microwave antenna built around commercial automated network analyzer (HP8510) designed for measurement and characterization of microwave circuits and components. Contains highly capable microwave receiver also suitable for far-field and radar-cross-section measurements. Receiver operates in fast-data-acquisition mode at rate of one new data point every millisecond without averaging. Also operates with greater sensitivity by use of averaging feature at time penalty of 0.2 ms per average. Time-domain option added to analyzer enables it to perform time-domain reflectometry.

Kunath, Richard R.↗

Benchmark Testing of the Largest Titanium Aluminide Sheet Subelement Conducted

To evaluate wrought titanium aluminide (gamma TiAl) as a viable candidate material for the High-Speed Civil Transport (HSCT) exhaust nozzle, an international team led by the NASA Glenn Research Center at Lewis Field successfully fabricated and tested the largest gamma TiAl sheet structure ever manufactured. The gamma TiAl sheet structure, a 56-percent subscale divergent flap subelement, was fabricated for benchmark testing in three-point bending. Overall, the subelement was 84-cm (33-in.) long by 13-cm (5-in.) wide by 8-cm (3-in.) deep. Incorporated into the subelement were features that might be used in the fabrication of a full-scale divergent flap. These features include the use of: (1) gamma TiAl shear clips to join together sections of corrugations, (2) multiple gamma TiAl face sheets, (3) double hot-formed gamma TiAl corrugations, and (4) brazed joints. The structural integrity of the gamma TiAl sheet subelement was evaluated by conducting a room-temperature three-point static bend test.

Bartolotta, Paul A.↗

Prospects for Nonlinear Laser Diagnostics in the Jet Noise Laboratory

Two experiments were conducted to test whether optical methods, which rely on laser beam coherence, would be viable for off-body flow measurement in high-density, compressible-flow wind tunnels. These tests measured the effects of large, unsteady density gradients on laser diagnostics like laser-induced thermal acoustics (LITA). The first test was performed in the Low Speed Aeroacoustics Wind Tunnel (LSAWT) of NASA Langley Research Center's Jet Noise Laboratory (JNL). This flow facility consists of a dual-stream jet engine simulator (with electric heat and propane burners) exhausting into a simulated flight stream, reaching Mach numbers up to 0.32. A laser beam transited the LSAWT flow field and was imaged with a high-speed gated camera to measure beam steering and transverse mode distortion. A second, independent test was performed on a smaller laboratory jet (Mach number < 1.2 and mass flow rate < 0.1 kg/sec). In this test, time-averaged LITA velocimetry and thermometry were performed at the jet exit plane, where the effect of unsteady density gradients is observed on the LITA signal. Both experiments show that LITA (and other diagnostics relying on beam overlap or coherence) faces significant hurdles in the high-density, compressible, and turbulent flow environments similar to those of the JNL.

Herring, Gregory C.↗

The 2010 ILSO-ISRU Field Test at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

For the advanced Moessbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform X-ray fluorescence analysis simultaneously to Moessbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The ISRU 2010 field campaign demonstrated that in-situ Moessbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

Klingelhoefer, G.↗

Risk Reduction Testing of Superconducting Coils for the High Efficiency Megawatt Motor

Second generation high temperature superconducting coils provide a very attractive level of performance for use in the field winding of electric machines for aircraft. Aside from maintaining these coils at cryogenic temperatures, much care must be taken to prevent damaging these relatively fragile materials due to excessive stress. Thermal stresses due to temperature cycling and mechanical stresses due to centrifugal forces are the most critical for the High Efficiency Megawatt Motor. This paper summarizes two test campaigns that were undertaken to reduce the risks posed by these loads. In one campaign, several superconducting coils were fabricated, thermally cycled up to 50~times, and electrically tested in liquid nitrogen to assess the change in superconductivity metrics throughout thermal cycling. In the other campaign, a full-scale superconducting coil was fabricated, a test article was designed to produce a representative stress environment in the coil, the test article and coil were rotated at room temperature up to a speed of 11,800~rpm, and the superconductivity metrics were measured in liquid nitrogen before and after each rotation. The experimental results demonstrate that the superconducting coils manufactured in house can survive both thermal cycling and high speed rotation with no appreciable degradation in superconducting performance.

partially superconducting electric machine↗

Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

Fluorescence↗

A modified objective mapping technique for scatterometer wind data

A method for generating high-resolution wind maps from scatterometer data was developed and tested on synthetic data for the northeast Pacific Ocean. It is shown that, unlike the wind fields generated by current GCMs, the wind maps constructed by this method retain the high spatial resolution of the scatterometer wherever adequate measurements exist. For the NASA scatterometer, this method would produce every 12 hours a wind map with spatial resolution that preserves the small-scale features of the original data over about half the mapped region. Over the rest of the region, maps with somewhat lower resolution and accuracy will be obtained.

Kelly, Kathryn A.↗

Effect of Microscopic Damage Events on Static and Ballistic Impact Strength of Triaxial Braid Composites

In previous work, the ballistic impact resistance of triaxial braided carbon/epoxy composites made with large flat tows (12k and 24k) was examined by impacting 2 X2 X0.125" composite panels with gelatin projectiles. Several high strength, intermediate modulus carbon fibers were used in combination with both untoughened and toughened matrix materials. A wide range of penetration thresholds were measured for the various fiber/matrix combinations. However, there was no clear relationship between the penetration threshold and the properties of the constituents. During some of these experiments high speed cameras were used to view the failure process, and full-field strain measurements were made to determine the strain at the onset of failure. However, these experiments provided only limited insight into the microscopic failure processes responsible for the wide range of impact resistance observed. In order to investigate potential microscopic failure processes in more detail, quasi-static tests were performed in tension, compression, and shear. Full-field strain measurement techniques were used to identify local regions of high strain resulting from microscopic failures. Microscopic failure events near the specimen surface, such as splitting of fiber bundles in surface plies, were easily identified. Subsurface damage, such as fiber fracture or fiber bundle splitting, could be identified by its effect on in-plane surface strains. Subsurface delamination could be detected as an out-of-plane deflection at the surface. Using this data, failure criteria could be established at the fiber tow level for use in analysis. An analytical formulation was developed to allow the microscopic failure criteria to be used in place of macroscopic properties as input to simulations performed using the commercial explicit finite element code, LS-DYNA. The test methods developed to investigate microscopic failure will be presented along with methods for determining local failure criteria that can be used in analysis. Results of simulations performed using LS-DYNA will be presented to illustrate the capabilities and limitations for simulating failure during quasi-static deformation and during ballistic impact of large unit cell size triaxial braid composites.

Littell, Justin D.↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

NOAA AVHRR Land Surface Albedo Algorithm Development

The primary objective of this research is to develop a surface albedo model for the National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR). The primary test site is the Konza prairie, Kansas (U.S.A.), used by the International Satellite Land Surface Climatology Project (ISLSCP) in the First ISLSCP Field Experiment (FIFE). In this research, high spectral resolution field spectrometer data was analyzed to simulate AVHRR wavebands and to derive surface albedos. Development of a surface albedo algorithm was completed by analysing a combination of satellite, field spectrometer, and ancillary data. Estimated albedos from the field spectrometer data were compared to reference albedos derived using pyranometer data. Variations from surface anisotropy of reflected solar radiation were found to be the most significant albedo-related error. Additional error or sensitivity came from estimation of a shortwave mid-IR reflectance (1.3-4.0 micro-m) using the AVHRR red and near-IR bands. Errors caused by the use of AVHRR spectral reflectance to estimate both a total visible (0.4-0.7 micro-m) and near-IR (0.7-1.3 micro-m) reflectance were small. The solar spectral integration, using the derived ultraviolet, visible, near-IR and SW mid-IR reflectivities, was not sensitive to many clear-sky changes in atmospheric properties and illumination conditions.

Toll, D. L.↗

Analysis and Comparison of Surface Roughness Effects on Pressure Data from SLS Wind Tunnel Test

Unsteady flows are becoming a more characterized field of study as advancements in technology is allowing for more high-speed, time-resolved data acquisition. It is important to understand these flows as the shock-wave boundary-layer interactions and separation they are involved with can generate extreme loads caused by high pressure and temperature on the body of a flight vehicle. It is vital to characterize these loads, as they can impede upon the structural integrity of a high-speed system. A common instrument utilized today to characterize pressure distributions caused by unsteady flows are unsteady pressure transducers. Set flush with the surface of a flight vehicle or wind tunnel model, these transducers can provide a pressure distribution, capturing the frequency of unsteady loads that could impinge upon the test article. A couple negative aspects of this instrumentation is that they are expensive, have long lead times, and a pressure distribution can only be determined in one discrete location where the transducer is installed. An optical diagnostic known as unsteady pressure-sensitive paint (uPSP) can help to satisfy these deficiencies. This is a spray paint that can be applied to a surface of a model to provide a global pressure distribution across the whole painted region.2 A complete picture of the fluid dynamic pressures occurring on the surface of a test article can be analyzed, especially in locations where it may have been impossible to install a transducer. Pressure-sensitive paint is also less expensive than traditional pressure transducers, which are, on average, about $2,000 each including the cost of installation.3 Unsteady PSP will not replace unsteady pressure transducers, but the transducers can be used to validate the PSP response to the flow and measure frequencies higher than the frequency response of the paint. One issue that can arise using these tools simultaneously, is that the surface roughness of the uPSP can affect the pressure readings of the transducers. Applying the uPSP to the surface of the model is going to affect the flow in some way as the topography of the model is now different than if it was not painted. One study with steady PSP conducted by Amer, Obara, and Liu at NASA Langley concluded that the PSP surface roughness was minimally intrusive at different test conditions with various lift, drag, etc., however, it was noted that data from some pressure transducers had decreased, likely due to the uneven application of the PSP in the localized region of the transducers.9 Sugioka et. al. tested various formulations of uPSP to study surface roughness effects on a Common Research Model (CRM) in transonic flow. The influence of uPSP on the surface of the model, depending on how it was formulated, was noted to have the possibility of relocating the shock wave present in the flow. This study was conducted to examine and compare transducer data acquired in December 2017 of a 4% scale model of the Space Launch System (SLS) performed at NASA Ames Research Center (ARC) Unitary Plan Wind Tunnel (UPWT). One goal of the test was to demonstrate to the customer the potential of the uPSP system developed at NASA ARC. The effect of uPSP on transducer signals also became an interest in this experiment and is the reason for this data analysis. The results of this study were discussed with the SLS team to help them make decisions regarding the next test on an SLS model with the PSP and Unitary Plan Wind Tunnel teams.

pressure-sensitive paint↗

Comparative lifetesting results for microchannel plates in windowless EUV photon detectors

Microchannel plates (MCPs) from seven manufacturers were subjected to a series of tests to determine their suitability for the Extreme Ultraviolet Explorer satellite. Comparative data are presented for sixteen MCP tandem pairs with channel length to diameter ratios (l/d) ranging from 40:1 to 60:1 and for two saturable (curved channel) MCPs with l/d's of 80:1. Results for MCPs with funnelled channel throats are also discussed. Properties of the MCPs which were monitored include: background count rate, output charge pulse height distribution (PHD), modal gain, PHD full width half maximum (FWHM), and extreme ultraviolet (EUV) photon quantum efficiency. Five detectors were chosen for further lifetime testing consisting of a mild bake to 100 C, and charge extraction to 0.01 coulombs, repeated high voltage cycling and reexposure to one atmosphere conditions. The results of these tests and their implications for the flight detectors are discussed. Erratic events in the detector background were recorded, probably due to field emission from high voltage surfaces or the absorption of water vapor into the electrode following exposure to air. The steps taken to control the detector background are discussed.

Malina, R. F.↗

Application of DPIV to Enhanced Mixing Heated Nozzle Flows

Digital Particle Imaging Velocimetry (DPIV) is a planar velocity measurement technique that continues to be applied to new and challenging engineering research facilities while significantly reducing facility test time. DPIV was used in the GRC Nozzle Acoustic Test Rig (NATR) to characterize the high temperature (560 C), high speed (is greater than 500 m/s) flow field properties of mixing enhanced jet engine nozzles. The instantaneous velocity maps obtained using DPIV were used to determine mean velocity, rms velocity and two-point correlation statistics to verify the true turbulence characteristics of the flow. These measurements will ultimately be used to properly validate aeroacoustic model predictions by verifying CFD input to these models. These turbulence measurements have previously not been possible in hot supersonic jets. Mapping the nozzle velocity field using point based techniques requires over 60 hours of test time, compared to less than 45 minutes using DPIV, yielding a significant reduction in testing time. A dual camera DPIV configuration was used to maximize the field of view and further minimize the testing time required to map the nozzle flow. The DPIV system field of view covered 127 by 267 mm. Data were acquired at 19 axial stations providing coverage of the flow from the nozzle exit to 2.37 in downstream. At each measurement station, 400 image frame pairs were acquired from each camera. The DPIV measurements of the mixing enhanced nozzle designs illustrate the changes in the flow field resulting in the reduced noise signature.

Wernet, Mark P.↗

Development of a portable high-T c spherical neutron polarimetry device at the Oak Ridge National Laboratory

Spherical neutron polarimetry is a powerful polarized neutron scattering technique used to determine complex magnetic structures which are only partly accessible by other methods. This technique measures the full neutron polarization change upon scattering from a sample by fully decoupling the incoming and outgoing neutron polarization with a zero-field chamber placed at the sample position. Recent advancements and testing are presented for a new spherical neutron polarimetry device utilizing high-T c superconducting YBCO films, PHiTPAD, at the High Flux Isotope Reactor at Oak Ridge National Laboratory. Furthermore, we introduce a conceptual design that utilizes wavelength-independent adiabatic transitions to adapt spherical neutron polarimetry for use with pulsed neutron sources, thereby expanding its potential applications in neutron scattering research.

47 OTHER INSTRUMENTATION↗

Hybrid propulsion for launch vehicle boosters: A program status update

Results obtained in studying the origin and suppression of large-amplitude pressure oscillations in a 24 in. diameter hybrid motor using a liquid oxygen/hydroxylterminated polybutadiene/polycyclopentadiene propellant system are discussed. Tests conducted with liquid oxygen flow rates varying from 10 to 40 lbm/sec were designed to gauge the effectiveness of various vaporization chamber flow fields, injector designs, and levels of heat addition in suppressing high-frequency longitudinal mode oscillations. Longitudinal acoustic modes did not arise in any tests. However, initial testing revealed the presence of high-amplitude, sinusoidal, nonacoustic oscillations persisting throughout the burn durations. Analysis showed this to be analogous to chug mode instability in liquid rocket engines brought about by a coupling of motor combustion processes and the liquid oxygen feed system. Analytical models were developed and verified by test data to predict the amplitude and frequency of feed-system-coupled combustion pressure oscillations. Subsequent testing showed that increasing the feed system impedance eliminated the bulk mode instability. This paper documents the work completed to date in performance of the Hybrid Propulsion Technology for Launch Vehicle Boosters Program (NAS8-39942) sponsored by NASA's George C. Marshall Space Flight Center.

Carpenter, R. L.↗

Exploring code portability solutions for HEP with a particle tracking test code

Traditionally, high energy physics (HEP) experiments have relied on x86 CPUs for the majority of their significant computing needs. As the field looks ahead to the next generation of experiments such as DUNE and the High-Luminosity LHC, the computing demands are expected to increase dramatically. To cope with this increase, it will be necessary to take advantage of all available computing resources, including GPUs from different vendors. A broad landscape of code portability tools—including compiler pragma-based approaches, abstraction libraries, and other tools—allow the same source code to run efficiently on multiple architectures. In this paper, we use a test code taken from a HEP tracking algorithm to compare the performance and experience of implementing different portability solutions. While in several cases portable implementations perform close to the reference code version, we find that the performance varies significantly depending on the details of the implementation. Achieving optimal performance is not easy, even for relatively simple applications such as the test codes considered in this work. Several factors can affect the performance, such as the choice of the memory layout, the memory pinning strategy, and the compiler used. The compilers and tools are being actively developed, so future developments may be critical for their deployment in HEP experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗