Search NASA⌕ Search

SEARCH · Search NASA

Results for “holographic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Ruled and holographic gratings experiment (AO 138-5)

Experiments on the the Long Duration Exposure Facility involving the study of the behavior of diffraction gratings, ruled replica, holographic, and ion etched masters with a long exposure to the space environment are discussed. To separate the metallic coatings compartment, some mirrors were added to the experiment. In order to be free from grating senescence on ground, one set of reference compounds was stored. Two sets of compounds were loaded, exposed, and shaded typed, in order to differentiate vacuum influences and sun illumination, cosmic dust, and radiation incidences. The investigation of possible damages was operated according to the fundamental triple point of view of wavefront flatness, absolute efficiency, and stray light level.

Bonnemason, Francis↗

Holographic interferometry at the NASA-Ames Hypervelocity Free-Flight Aerodynamic Facility

A laser holographic interferometer has been designed and developed to improve flow visualization for models in free-flight at high velocities and low freestream static pressures. Of special interest is the flow structure due to high-temperature effects in the post-shock region of models traveling at hypervelocity. A dual-plate technique with a double-pass, Michelson-type configuration has been incorporated in an existing hypervelocity ballistic range. Holograms of 5-deg blunt conical models traveling at 5 km/sec in air at a freestream static pressure of 0.08 atm have been made. Finite- and infinite-fringe interferograms were reconstructed from the holograms and provided qualitative flowfield results. In addition, a digital scanning technique was also used to produce a 'synthetic' infinite-fringe interferogram from the analysis of an experimental finite-fringe interferogram. A 'synthetic' infinite-fringe interferogram shows detail in the wake region not found in the experimental interferograms.

Tam, Tim C.↗

Optical Correlator With Complex Holographic Filter

Experimental real-time optical correlator includes complex-valued holographic filter computed from one of two input scenes. Made more tolerant of errors in patterns to be recognized. Filter function essentially coded hologram computed by Burchhardt's method, in which complex value of each pixel of fast Fourier transform of image represented by three real, nonnegative numbers. In generating optical correlator according to method, phasor of each pixel in Fourier transform represented by intensities in three adjacent pixels.

Chao, Tien-Hsin↗

Ruled and holographic diffraction gratings experiment (AO 138-5)

Ruled and Holographic Gratings (originals and replicas) proposed for use in loaded spectroscopic experiments are discussed. The optical performance of the gratings was tested in the low-earth orbital environment. Comparisons were made with identical components, which had been stored on the earth for the duration of the experiment. The following tests were performed: wavefront planeity, light efficiency, and stray-light level.

Francis Bonnemason↗

Ruled and holographic experiment (AO 138-5)

The AO 138-5 experiment has been designed, via the French Cooperative Payload (FRECOPA) experiment with the aim to study the optical behavior of different diffraction gratings submitted to space vacuum long exposure and solar radiation. Samples were rules and holographic gratings, masters or replica, and some additional control mirrors with various coatings. The experiment was located on the B3, trailing edge of the Long Duration Exposure Facility (LDEF) and has been protected against atomic oxygen flux. The experienced thermal cycling has been evaluated from -23 C to 66 C during the flight, 34,000 orbits. The analysis has been focused on the triple point characterization including light efficiency, wavefront flatness quality and stray light level. Tests were conducted on control mirrors and gratings loaded but not exposed to cosmic dust or solar irradiations. They did not show any significant variations. Solar exposure has damaged the coating reflectivity in the ultraviolet region, the degradation is higher with the gratings, in terms of efficiency. However, wavefront flatness quality and stray light level tests revealed no additional changes.

Bonnemason, Francis↗

Holographic data storage crystals for the LDEF

Lithium niobate is a significant electro-optic material, with potential applications in ultra high capacity storage and processing systems. Lithium niobate is the material of choice for many integrated optical devices and holographic mass memory systems. For crystals of lithium niobate were passively exposed to the space environment of the Long Duration Exposure Facility (LDEF). Three of these crystals contained volume holograms. Although the crystals suffered the surface damage characteristics of most of the other optical components on the Georgia Tech tray, the crystals were recovered intact. The holograms were severely degraded because of the lengthy exposure, but the bulk properties are being investigated to determine the spaceworthiness for space data storage and retrieval systems.

Callen, W. Russell↗

Conically scanned lidar telescope using holographic optical elements

Holographic optical elements (HOE) using volume phase holograms make possible a new class of lightweight scanning telescopes having advantages for lidar remote sensing instruments. So far, the only application of HOE's to lidar has been a non-scanning receiver for a laser range finder. We introduce a large aperture, narrow field of view (FOV) telescope used in a conical scanning configuration, having a much smaller rotating mass than in conventional designs. Typically, lidars employ a large aperture collector and require a narrow FOV to limit the amount of skylight background. Focal plane techniques are not good approaches to scanning because they require a large FOV within which to scan a smaller FOV mirror or detector array. Thus, scanning lidar systems have either used a large flat scanning mirror at which the receiver telescope is pointed, or the entire telescope is steered. We present a concept for a conically scanned lidar telescope in which the only moving part is the HOE which serves as the primary collecting optic. We also describe methods by which a multiplexed HOE can be used simultaneously as a dichroic beamsplitter.

Schwemmer, Geary K.↗

Microwave holographic metrology for antenna diagnosis

Advances in antenna diagnostic methodologies have been very significant in recent years. In particular, microwave holographic diagnostic techniques have been applied very successfully in improving the performance of reflector and array antennas. These techniques use the knowledge of the measured amplitude and phase of the antenna radiated fields and then take advantage of the existing Fourier transform relationships between the radiated fields and the effective aperture or current distribution to eventually determine the reflector surface or array excitation coefficients anomalies. In this paper an overview of the recent developments in applying microwave holography is presented. The theoretical, numerical and measurement aspects of this technique is detailed by providing representative results.

Rahmat-Samii, Y.↗

A method of analyzing holographic interferograms of ballistic models in hypersonic free-flight

The objective of this research was to develop a method to extract integrated flowfield density information from finite-fringe interferograms produced with a laser holographic interferometer. This method was applied to two sets of holograms. An aeroassist flight experiment model flown in a mixture of 50 percent air - 50 percent argon and a blunt slender cone flown in air were flown at Mach 14.5 into freestream static pressures of 0.04 and 0.08 atm, respectively. The method of analysis can be separated into two main divisions. The first step is to identify fringes inside the wake in terms of the fringes in the freestream. This is important because refraction effects have obscured the region near the shock such that fringes cannot be followed into the wake region. The second step is to extrapolate the freestream fringes into the wake to determine the location of disturbance-related fringe shifts. Coupled with assumptions about the shape of the wake region, the locations of the disturbance-related fringe shifts can be related to the integrated density.

Kieffer, Douglas L.↗

Real-time optical correlator using computer-generated holographic filter on a liquid crystal light valve

Limitations associated with the binary phase-only filter often used in optical correlators are presently circumvented in the writing of complex-valued data on a gray-scale spatial light modulator through the use of a computer-generated hologram (CGH) algorithm. The CGH encodes complex-valued data into nonnegative real CGH data in such a way that it may be encoded in any of the available gray-scale spatial light modulators. A CdS liquid-crystal light valve is used for the complex-valued CGH encoding; computer simulations and experimental results are compared, and the use of such a CGH filter as the synapse hologram in a holographic optical neural net is discussed.

Chao, Tien-Hsin↗

Critical needs of fringe-order accuracies in two-color holographic interferometry

Requirements for the fringe order accuracy in two-color holographic interferometry are discussed with reference to crystal growth. A simple test cell (rectangular parallelepiped) containing a fluid is considered. The temperature and concentration variations are related to the fringe orders from the two interference patterns, and the uncertainties in the fringe orders are related to errors in the temperature and concentration determination. The formulation developed here is applied to the particular case of an aqueous solution of triglycerine sulfate as an example.

Vikram, C. S.↗

Holographic diagnostics of breakup phenomena of impinging jets for liquid rocket motor applications

The use of pulsed laser holography in analyzing the atomization of impinging jets is evaluated using a holographic camera system capable of recording a 3D image of the atomization process in 3 x 10 exp -8 seconds. The holocamera and the experimental configuration and procedure are described in detail. Two nozzles were fabricated to produce 1-mm diameter liquid water jets that impinged at 60 and 90 deg. Holograms were obtained for each nozzle at liquid velocities of 20 and 40 m/s. Analysis of the holograms revealed the evolution of the jets from the plane of emergence through the region of droplet formation. Features of interest included the growth of disturbances prior to the breakup region and the effect of these disturbances on the formation of ligaments and liquid globules. Preliminary analyses show that waves of atomized liquid formed after impingement are closely correlated to waves measured on the jets, leading to the possibility of controlling the atomization process at the nozzle.

Hess, C. F.↗

A large-field laser holographic focusing schilieren system

A large-field laser holographic focusing schlieren system for high-speed flow visualization has been built and evaluated. This system is based on a recently improved large-field focusing schlieren technique and is combined with laser holography methods to record three-dimensional flows. A coordinated experimental and computational study of supersonic flows over wedge, cone, and sphere geometries was conducted to evaluate the capabilities and limitations of the system. The ability of the system to focus on planes normal to its optical axis is demonstrated. The sharpness of focus of the present system was found to be limited. Issues regarding obtaining quantitative measurements of the density gradient are discussed.

Doggett, Glen P.↗

Visualization of hydrogen injection in a scramjet engine by simultaneous PLIF imaging and laser holographic imaging

Flowfield characterization has been accomplished for several fuel injector configurations using simultaneous planar laser induced fluorescence (PLIF) and laser holographic imaging (LHI). The experiments were carried out in the GASL-NASA HYPULSE real gas expansion tube facility, a pulsed facility with steady test times of about 350 microsec. The tests were done at simulated Mach numbers 13.5 and 17. The focus of this paper is on the measurement technologies used and their application in a research facility. The HYPULSE facility, the models used for the experiments, and the setup for the LHI and PLIF measurements are described. Measurement challenges and solutions are discussed. Results are presented for experiments with several fuel injector configurations and several equivalence ratios.

Anderson, Robert C.↗

Multi-layer holographic bifurcative neural network system for real-time adaptive EOS data analysis

Optical data processing techniques have the inherent advantage of high data throughout, low weight and low power requirements. These features are particularly desirable for onboard spacecraft in-situ real-time data analysis and data compression applications. The proposed multi-layer optical holographic neural net pattern recognition technique will utilize the nonlinear photorefractive devices for real-time adaptive learning to classify input data content and recognize unexpected features. Information can be stored either in analog or digital form in a nonlinear photorefractive device. The recording can be accomplished in time scales ranging from milliseconds to microseconds. When a system consisting of these devices is organized in a multi-layer structure, a feed forward neural net with bifurcating data classification capability is formed. The interdisciplinary research will involve the collaboration with top digital computer architecture experts at the University of Southern California.

Liu, Hua-Kuang↗

Imaging Spectrometers Using Concave Holographic Gratings

Imaging spectroscopy combines the spatial attributes of imaging with the compositionally diagnostic attributes of spectroscopy. For spacebased remote sensing applications, mass, size, power, data rate, and application constrain the scanning approach. For the first three approaches, substantial savings in mass and size of the spectrometer can be achieved in some cases with a concave holographic grating and careful placement of an order-sorting filter. A hologram etched on the single concave surface contains the equivalent of the collimating, dispersing, and camera optics of a conventional grating spectrometer and provides substantial wavelength dependent corrections for spherical aberrations and a flat focal field. These gratings can be blazed to improve efficiency when used over a small wavelength range or left unblazed for broadband uniform efficiency when used over a wavelength range of up to 2 orders. More than 1 order can be imaged along the dispersion axis by placing an appropriately designed step order-sorting filter in front of the one- or two-dimensional detector. This filter can be shaped for additional aberration corrections. The VIRIS imaging spectrometer based on the broadband design provides simultaneous imaging of the entrance slit from lambda = 0.9 to 2.6 microns (1.5 orders) onto a 128 x 128 HgCdTe detector (at 77 K). The VIRIS spectrometer was used for lunar mapping with the UH 24.in telescope at Mauna Kea Observatory. The design is adaptable for small, low mass, space based imaging spectrometers.

Gradie, J.↗

Multi-channel holographic birfurcative neural network system for real-time adaptive EOS data analysis

Viewgraphs on multi-channel holographic bifurcative neural network system for real-time adaptive Earth Observing System (EOS) data analysis are presented. The objective is to research and develop an optical bifurcating neuromorphic pattern recognition system for making optical data array comparisons and to evaluate the use of the system for EOS data classification, reduction, analysis, and other applications.

Liu, Hua-Kuang↗

Temporal averaging of phase measurements in the presence of spurious phase drift - Application to phase-stepped real-time holographic interferometry

A technique that compensates for low spatial frequency spurious phase changes during an interference experiment is developed; it permits temporal averaging of multiple-phase measurements, made before and after object displacement. The method is tested with phase-stepped real-time holographic interferometry applied to cantilever bending of a piezoelectric bimorph ceramic. Results indicate that temporal averaging of the corrected data significantly reduces the white noise in a phase measurement without incurring systematic errors or sacrificing spatial resolution. White noise is reduced from 3 deg to less than 1 deg using these methods.

Ovryn, B.↗