Search NASA⌕ Search

SEARCH · Search NASA

Results for “hybrid heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Evapotranspiration partitioning estimates from 8 methods from 47 NEON sites, 2019-2021

This dataset provides daily estimates of evapotranspiration (ET) and the transpiration-to-evapotranspiration ratio (T/ET) across 47 terrestrial National Ecological Observatory Network (NEON) sites spanning diverse environmental and biome conditions in the United States across three years of data (2019-2021). Daily ET is reported in both energy units (MJ m⁻² day⁻¹) and equivalent water depth (mm day⁻¹), assuming a constant latent heat of vaporization of 2.45 MJ/kg. The primary method uses a hybrid recurrent neural network–Penman–Monteith framework (RNN-PM), which integrates physically based surface energy balance constraints with data-driven learning to partition ET into transpiration and evaporation components. Model inputs include in situ meteorological observations (air temperature, vapor pressure deficit, wind speed, and radiation) combined with satellite-derived land surface temperature, leaf area index, and soil moisture. For benchmarking and uncertainty assessment, T/ET estimates from seven additional models are included: Priestley-Taylor Jet Propulsion Laboratory (PT-JPL), Penman-Monteith (P-M), Two-Source Energy Balance (TSEB), Support Vector Regression (SVR), and Categorical Boosting (CatBoost), among others—spanning empirical, machine-learning, and process-based approaches (see methods section or linked publication for detailed descriptions). Data Package Contents: The dataset a csv files containing daily ET and T/ET estimates for each site and model, along with associated metadata files these variables. Data can be accessed using common spreadsheet software (e.g., Microsoft Excel, LibreOffice) or programming environments such as R or Python. Together, these data support cross-site comparisons of ecosystem water use, evaluation of ET partitioning methods, and development of improved land–atmosphere exchange models.

EARTH SCIENCE > ATMOSPHERE↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ~12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation models of electron conics

Electron distribution functions (EDFs) with a peak oblique to the magnetic field, adjacent to but distinct from loss-cone features, have been observed by the DE 1, Viking, and S3-3 spacecraft in passes through the nightside auroral zone, polar cap, dayside cusp, and extended dayside auroral oval. Using particle simulations, two types of wave excitation and particle acceleration mechanisms which may contribute to producing these electron conic distributions are investigated. The first involves excitation of upper-hybrid waves by the electron loss cone, and the subsequent perpendicular heating of the background and thermal electrons. The second involves excitation of downward propagating parallel modes by an auroral electron beam which frequently accompanies the upflowing electron conics. These modes provide parallel acceleration, which modifies the GDF. Those electrons which are not lost to the atmosphere and mirror back up the magnetic field line give rise to enhancements in the GDF at the edge of the loss cone.

Roth, I.↗

NASA Tech Briefs, April 2010

Topics covered include: Active and Passive Hybrid Sensor; Quick-Response Thermal Actuator for Use as a Heat Switch; System for Hydrogen Sensing; Method for Detecting Perlite Compaction in Large Cryogenic Tanks; Using Thin-Film Thermometers as Heaters in Thermal Control Applications; Directional Spherical Cherenkov Detector; AlGaN Ultraviolet Detectors for Dual-Band UV Detection; K-Band Traveling-Wave Tube Amplifier; Simplified Load-Following Control for a Fuel Cell System; Modified Phase-meter for a Heterodyne Laser Interferometer; Loosely Coupled GPS-Aided Inertial Navigation System for Range Safety; Sideband-Separating, Millimeter-Wave Heterodyne Receiver; Coaxial Propellant Injectors With Faceplate Annulus Control; Adaptable Diffraction Gratings With Wavefront Transformation; Optimizing a Laser Process for Making Carbon Nanotubes; Thermogravimetric Analysis of Single-Wall Carbon Nanotubes; Robotic Arm Comprising Two Bending Segments; Magnetostrictive Brake; Low-Friction, Low-Profile, High-Moment Two-Axis Joint; Foil Gas Thrust Bearings for High-Speed Turbomachinery; Miniature Multi-Axis Mechanism for Hand Controllers; Digitally Enhanced Heterodyne Interferometry; Focusing Light Beams To Improve Atomic-Vapor Optical Buffers; Landmark Detection in Orbital Images Using Salience Histograms; Efficient Bit-to-Symbol Likelihood Mappings; Capacity Maximizing Constellations; Natural-Language Parser for PBEM; Policy Process Editor for P(sup 3)BM Software; A Quality System Database; Trajectory Optimization: OTIS 4; and Computer Software Configuration Item-Specific Flight Software Image Transfer Script Generator.

Source record↗

Geological Thermal Energy Storage (GeoTES) Charged with Solar Thermal Technology Using Depleted Oil/Gas Reservoirs and Carnot-Battery Technique Using Shallow Reservoirs: Preprint

Geological thermal energy storage (GeoTES) utilizes the underground reservoirs to storage and dispatch energy per given demand schedule over a time scale up to seasons of a year. The energy input can be of various sources/forms; in this paper, we investigate 1) the GeoTES technology with solar thermal hybridization and using depleted oil/gas reservoirs; 2) the GeoTES technology with heat pumps charged by excess renewable electricity and using low-temperature shallow reservoirs. For each GeoTES technology, we carry out the suitability analysis of candidate reservoirs, develop initial techno-economic models, and validate the model with selected case study. The paper provides an overview of our technical progress on the topics of concern and aims to promote a wider acceptance of the GeoTES technologies in the future energy market.

Carnot battery↗

Thermal Energy Storage Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage models developed within the HYBRID Modelica repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of concrete, latent heat, and packed-bed thermocline energy storage technologies for deployment in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to cyclically charge and discharge when exposed to time-varying boundary conditions. In addition, low-level surrogate models for some of the thermal energy storage technologies were created using Python. These lower order Python files are much cheaper to run (i.e., computationally faster) and thus operate well when incorporated within the stochastic optimization problems run for the IES program. Moreover, economic data was collected for use within the INL-developed Framework for Optimization of ResourCes and Economics (FORCE). This information is incorporated within the FORCE platform. This work has resulted in creation of systems-level models for concrete, latent heat, and thermocline thermal energy storage systems with associated control systems. Now that these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies (e.g., Storworks Power, EnergyNest) can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

25 ENERGY STORAGE↗

Radiative Heating Rate Profiles over the Southeast Atlantic Ocean during the 2016 and 2017 Biomass Burning Seasons

Marine boundary layer clouds, including the transition from stratocumulus to cumulus, are poorly represented in numerical weather prediction and general circulation models. Further uncertainties in the cloud structure arise in the presence of biomass burning carbonaceous aerosol, as is the case over the southeast Atlantic Ocean where biomass burning aerosol is transported from the African continent. As the aerosol plume progresses across the southeast Atlantic Ocean, radiative heating within the aerosol layer has the potential to alter the thermodynamic environment and therefore the cloud structure; however, limited work has been done to quantify this along the trajectory of the aerosol plume in the region. The deployment of the First Atmospheric Radiation Measurement Mobile Facility in support of the Layered Atlantic Smoke Interactions with Clouds field campaign provided a unique opportunity to collect observations of cloud and aerosol properties during two consecutive biomass burning seasons during July through October of 2016 and 2017 over Ascension Island (7.96 °S, 14.35 °W). Using observed profiles of temperature, humidity, and clouds from the field campaign, alongside aerosol optical properties from MERRA-2 as input for the Rapid Radiation Transfer Model, profiles of the radiative heating rate due to aerosols and clouds were computed. Radiative heating is also assessed across the southeast Atlantic Ocean using an ensemble of back trajectories from the Hybrid Single Particle Lagrangian Integrated Trajectory Model. Idealized experiments using the Rapid Radiation Transfer Model with and without aerosols and a range of values for the single scattering albedo demonstrate that shortwave heating within the aerosol layer above Ascension Island can locally range between 2 and 8 K per day depending on the aerosol optical properties, though impacts of the aerosol can be felt elsewhere in the atmospheric column. When considered under clear conditions, the aerosol has a cooling effect at the TOA and based on the observed cloud properties at Ascension Island, the cloud albedo is not large enough to overcome this. Shortwave radiative heating due to biomass burning aerosol is not balanced by additional longwave cooling, and the net radiative impact results in a stabilization of the lower troposphere. However, these results are extremely sensitive to the single scattering albedo assumptions in models.

Allison B. Marquardt Collow↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Radiative heating rate profiles over the southeast Atlantic Ocean during the 2016 and 2017 biomass burning seasons

Marine boundary layer clouds, including the transition from stratocumulus to cumulus, are poorly represented in numerical weather prediction and general circulation models. Further uncertainties in the cloud structure arise in the presence of biomass burning carbonaceous aerosol, as is the case over the southeast Atlantic Ocean, where biomass burning aerosol is transported from the African continent. As the aerosol plume progresses across the southeast Atlantic Ocean, radiative heating within the aerosol layer has the potential to alter the thermodynamic environment and therefore the cloud structure; however, limited work has been done to quantify this along the trajectory of the aerosol plume in the region. The deployment of the first Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF1) in support of the Layered Atlantic Smoke Interactions with Clouds field campaign provided a unique opportunity to collect observations of cloud and aerosol properties during two consecutive biomass burning seasons during July through October of 2016 and 2017 over Ascension Island (7.96° S, 14.35° W). Using observed profiles of temperature, humidity, and clouds from the field campaign alongside aerosol optical properties from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), as input for the Rapid Radiation Transfer Model (RRTM), profiles of the radiative heating rate due to aerosols and clouds were computed. Radiative heating is also assessed across the southeast Atlantic Ocean using an ensemble of back trajectories from the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model. Idealized experiments using the RRTM with and without aerosols and a range of values for the single-scattering albedo (SSA) demonstrate that shortwave (SW) heating within the aerosol layer above Ascension Island can locally range between 2 and 8 K d -1 depending on the aerosol optical properties, though impacts of the aerosol can be felt elsewhere in the atmospheric column. When considered under clear conditions, the aerosol has a cooling effect at the TOA, and based on the observed cloud properties at Ascension Island, the cloud albedo is not large enough to overcome this. Shortwave radiative heating due to biomass burning aerosol is not balanced by additional longwave (LW) cooling, and the net radiative impact results in a stabilization of the lower troposphere. However, these results are extremely sensitive to the single-scattering albedo assumptions in models.

54 ENVIRONMENTAL SCIENCES↗

Cause and impact of low-frequency chirping modes in DIII-D hybrid discharges

Significant variations in MHD activity and fast-ion transport are observed in the DIIID high-beta, steady-state hybrid discharges with a mixture of Electron Cyclotron (EC) waves and Neutral Beam Injection (NBI). When Electron Cyclotron Heating (ECH) or Current Drive (ECCD) is applied, Alfven Eigenmodes (AEs) are usually suppressed and replaced by low-frequency bursting modes. The analysis of a recently compiled database of hybrid discharges suggests that the change of the fast-ion pressure especially the perpendicular pressure is the main factor responsible for the instability transition. The lower ratio of fast-ion injection speed v inj to Alfven speed v alfven and slight drop of safety factor q min during ECCD may also facilitate the transition. The database shows that AEs mainly occur when the fast-ion fraction P f /P total is less than 0.53 and v inj /v alfven is greater than 0.50, while low-frequency bursting modes appear in the opposite regime. In this research, P f and P total are the central fast-ion pressure from classical prediction and total plasma pressure, respectively. The reason why the instability transition correlates with P f /P total and v inj /v alfven is that they can significantly modify the drive of low-frequency bursting modes and AEs. The explanation is supported by the observation that low-frequency bursting modes are rarely seen in the hybrids with NBI only, with EC waves and counter-NBI, or with high plasma density. A careful check of the low-frequency bursting modes suggests that they are mainly chirping (neoclassical) tearing modes [referred to as chirping (N)TM], i.e. the mode frequency firstly jumps up from the steady (N)TM frequency, then chirps down, and finally returns to the steady (N)TM frequency. Sometimes, the (N)TMs are fully stabilized and replaced with pure fishbones. Lastly, the resonance condition calculation and ’Kick’ model simulations suggest that (N)TMs and fishbones can interact through modification of the fast ion distribution in phase space, which influences the drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid Analytics Solution for Power Plant Operations

Expert Microsystems, Inc., MapEx Software Inc. and XMPLR Energy LLC have teamed to submit a proposal to the US Department of Energy’s Office of Fossil Energy to improve the efficiency, reliability and flexibility of existing coal-based power plants. The project, titled Hybrid Analytics Solution to Improve Coal Power Plant Operations (the “Hybrid Analytics” project), will develop, demonstrate and commercialize a novel approach that integrates two proven real-time monitoring techniques. The Hybrid Analytics approach integrates into a single, integrated solution: a) an established, advanced data-driven analytics solution that includes artificial intelligence, advanced pattern recognition and machine-learning techniques and b) a well-proven, first principle thermal heat balance model solution. The future role of coal plants will depend on the ability to cycle and follow loads to meet marginal power demands, accommodate renewables and support the grid. Essential to success in this new role is a plant’s ability to maintain high reliability, efficiency and flexibility. However, these changing operational demands put significant stresses on power plant components that directly impact the ability to deliver these requirements. In the past, plants have independently monitored performance using physics-based solutions (heat rate, boiler losses, etc.) and reliability using data-driven analytics (advanced pattern recognition). The Hybrid Analytics solution integrates both approaches to enhance fault detection, provide automated diagnostics and estimates of remaining time to act, and provide critical, enhanced and accurate real-time information to coal plant operators. As a result, coal plants can improve efficiency, reliability, and flexibility and can cost-effectively maintain their key role in the power delivery system.

01 COAL, LIGNITE, AND PEAT↗

Influence of geometry on columnar to equiaxed transition during electron beam powder bed fusion of IN718

Correlation between spot-melt scan parameters (linear spot-density aka areal energy density), build geometry, and solidification microstructure evolution (columnar vs equiaxed) in a powder bed fusion technology is investigated. It is shown that to maintain the equiaxed solidification microstructure evolution in electron beam powder bed additive manufacturing (AM), the areal energy density per layer needs to be scaled with respect to the 2D cross-sectional area of the layer being melted. Samples with two different cross-sectional areas (40 × 40 mm and 20 × 20 mm) have been fabricated with varying areal energy densities. For a given square cross-section (20 × 20 mm), increasing the areal energy density (4.8 MJ/sq.m to 14.7 MJ/sq.m) transitioned the solidification microstructure from columnar to equiaxed. The observed microstructure data (Electron Back Scattered Diffraction - EBSD) is quantified by calculating the principal component (PC) score using a spatial statistics methodology. The sample with equiaxed grains is found to have a low PC score while the sample with columnar grain had a high PC score. A semi-analytical model is used to simulate the heat transfer and the local solidification conditions as a function of processing parameters (linear spot-density). The result from the heat transfer model is correlated with previously quantified microstructure data. Space-Time analysis of the melt pattern is done and correlated with the observed microstructure. In addition, from the findings, appropriate parameters have been used to additively manufacture a turbine blade with site-specific or hybrid solidification microstructure (traditional fabrication possible via a patented method of localized cold working and heat treatment).

36 MATERIALS SCIENCE↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗

Electrical and Thermal Characterization of 3D Printed Thermoplastic Parts with Embedded Wires for High Current-Carrying Applications

Fabrication of parts exhibiting multi-functionality has recently been complemented by hybrid polymer extrusion additive manufacturing in combination with wire embedding technology. While much mechanical characterization has been performed on parts produced with fused deposition modeling, limited characterization has been performed when combined electrical and thermal loads are applied to 3D printed multi-material parts. As such, this work describes the design, fabrication, and testing of 3D printed thermoplastic coupons containing embedded copper wires that carried current. An automated fabrication process was used employing a hybrid additive manufacturing machine that dispensed polycarbonate thermoplastic and embedded bare copper wires. Testing included AC and DC hipot testing as well as thermal testing on as-fabricated and heat treated coupons to determine the effect of porosity in the substrate. The heat-treated parts contained reduced amounts of porosity, as corroborated through scanning electron microscopy, which led to 50 % increased breakdown strength and 30 to 40 % increased heat dissipation capabilities. The results of this research are describing a set of design protocol that can be used as a guideline for 3D printed embedded electronics to predict the electrical and thermal behavior.

Hipot testing↗