Search NASA⌕ Search

SEARCH · Search NASA

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

NIRCam: The JWST Near-IR Camera and Slitless Spectrograph

NIRCam is the primary near-infrared camera for JWST. It is well-suited for a wide variety of star formation and other scientific studies and will also be used for aligning the JWST primary mirror segments and telescope. NIRCam will provide high sensitivity, high spatial resolution images in a variety of filters over the 0.6 - 5 μm wavelength region including coronagraphic modes and slitless spectroscopic capabilities. NIRCam consists of two identical optical modules that have adjacent 2.2' x 2.2' fields of view on the sky. Each module is composed of two channels that observe the same field at short (< 2.4 μm) or long (> 2.4 μm) wavelengths simultaneously, with optimized spatial sampling in each channel. NIRCam optical elements include narrow (R = 100), medium (R = 10), and wide (R <= 4) filters, coronagraphic imaging spot and bar masks, and grisms that provide wide-field or time-series slitless spectroscopy. These major NIRCam features will be introduced, and some applications to galactic star formation will be briefly presented.

Greene, Thomas↗

STARscan: Spatial Targeting and Alignment Rig for Scanning

The Spatial Targeting and Alignment Rig for Scanning (STARScan) is a 3D photogrammetry system developed at NASA Ames Research Center to address bottlenecks in pre/post-test scanning of arcjet test articles. It reduces scan time from 15 minutes with handheld laser scanners to under 2 minutes, while maintaining high accuracy (±0.2-0.5 mm). STARScan integrates an array of cameras, a 3D-printed rack, turntable, and LED light panels, all controlled via a user-friendly graphical user interface (GUI). The system offers tools for scan visualization, mesh analysis, and data export, automating tasks such as alignment of pre/post-test scans, material recession measurements, surface roughness assessment, and curvature analysis. By integrating scanning, imaging, and post-processing into one application, STARScan significantly improves efficiency in scanning and analyzing arcjet test samples.

Ablation↗

Imaging Schwarzschild multilayer X-ray microscope

We have designed, analyzed, fabricated, and tested Schwarzschild multilayer X-ray microscopes. These instruments use flow-polished Zerodur mirror substrates which have been coated with multilayers optimized for maximum reflectivity at normal incidence at 135 A. They are being developed as prototypes for the Water Window Imaging X-Ray Microscope. Ultrasmooth mirror sets of hemlite grade sapphire have been fabricated and they are now being coated with multilayers to reflect soft X-rays at 38 A, within the biologically important 'water window'. In this paper, we discuss the fabrication of the microscope optics and structural components as well as the mounting of the optics and assembly of the microscopes. We also describe the optical alignment, interferometric and visible light testing of the microscopes, present interferometrically measured performance data, and provide the first results of optical imaging tests.

Hoover, Richard B.↗

Radio-Optical Alignments in a Low Radio Luminosity Sample

We present an optically-based study of the alignment between the radio axes and the optical major axes of eight z approximately 0.7 radio galaxies in a 7C sample. The radio galaxies in this sample are approximately 20-times less radio luminous than 3C galaxies at the same redshift, and are significantly less radio-luminous than any other well-defined samples studied to date. Using Nordic Optical Telescope images taken in good seeing conditions at rest-frame wavelengths just longward of the 4000A break, we find a statistically significant alignment effect in the 7C sample. Furthermore, in two cases where the aligned components are well separated from the host we have been able to confirm spectroscopically that they are indeed at the same redshift as the radio galaxy. However, a quantitative analysis of the alignment in this sample and in a corresponding 3C sample from HST (Hubble Space Telescope) archival data indicates that the percentage of aligned flux may be lower and of smaller spatial scale in the 7C sample. Our study suggests that alignments on the 50-kpc scale are probably closely related to the radio luminosity, whereas those on the 15 kpc scale are not. We discuss these results in the context of popular models for the alignment effect.

Lacy, Mark↗

Image data rate converter: A concept

Establish data tracks on periphery of rotating drum and axially displace entire drum to place given track in alignment with either fixed or rotating read/record head. Accurate control of speed drum and rotating head can be accomplished by using separate synchronous motors driven by digitally-set oscillators to provide required difference in speed.

Billingsley, F. C.↗

Imaging Polarized Dust Emission in Star Formation Regions with the OVRO MM Array

We present OVRO interferometric observations of linearly polarized emission from magnetically aligned dust grains which allow the magnetic field geometry in nearby star formation regions to be probed on scales ranging from 100 to 3000 AU. Current results include observations of the young stellar objects NGC1333/IRAS 4A, IRAS 16293-2422 and Orion IRc2-KL.

Akeson, Rachel↗

Flow-aligned jets in the magnetospheric cusp: Results from the Geospace Environment Modeling Pilot program

The extended flight of the Airborne Ionospheric Observatory during the Geospace Environment Modeling (GEM) Pilot program on January 16, 1990, allowed continuous all-sky monitoring of the two-dimensional ionospheric footprint of the northward interplanetary magnetic field (IMF) cusp in several wavelengths. Especially important in determining the locus of magnetosheath electron precipitation was the 630.0-nm red line emission. The most striking morphological change in the images was the transient appearance of zonally elongated regions of enhanced 630.0-nm emission which resembled 'rays' emanating from the centroid of the precipitation. The appearance of these rays was strongly correlated with the Y component of the IMF: when the magnitude of B(sub y) was large compared to B(sub z), the rays appeared; otherwise, the distribution was relatively unstructured. Late in the flight the field of view of the imager included the field of view of flow measurements from the European incoherent scatter radar (EISCAT). The rays visible in 630.0-nm emission exactly aligned with the position of strong flow jets observed by EISCAT. We attribute this correspondence to the requirement of quasi-neutrality; namely, the soft electrons have their largest precipitating fluxes where the bulk of the ions precipitate. The ions, in regions of strong convective flow, are spread out farther along the flow path than in regions of weaker flow. The occurrence and direction of these flow bursts are controlled by the IMF in a manner consistent with newly opened flux tubes; i.e., when absolute value of B(sub y) greater than absolute value of B(sub z), tension in the reconnected field lines produce east-west flow regions downstream of the ionospheric projection of the x line. We interpret the optical rays (flow bursts), which typically last between 5 and 15 min, as evidence of periods of enhanced dayside (or lobe) reconnection when absolute value of B(sub y) greater than absolute value of B(sub z). The length of the reconnection pulse is difficult to determine, however, since strong zonal flows would be expected to persist until the tension force in the field line has decayed, even if the duration of the enhanced reconnection was relatively short.

Weiss, L. A.↗

Reconstruction of the 4D beam matrix

The widely used transverse parameters characterizing particle beams are the Twiss parameters. These parameters can be measured experimentally but they do not fully characterize the beam since they do not account for possible correlations in particle distribution between two transverse coordinates. These correlations may occur due to uncompensated magnetic field at the cathode or misalignment of focusing quadrupoles in the transport beamline. We test a novel diagnostic for diagnosing full 4D beam matrix which may be used to identify such imperfections. The diagnostic is based on transporting the beam through the beamline which includes a quadrupole and a skew quadrupole magnets and measuring the resulting 2D beam distribution at the screen downstream. Such a measurement can be viewed as measuring a 2D projection of the 4D distribution. Different settings of the quads provide measurements of different slices of the phase space. The reconstruction of the original beam matrix from a number of measurements is done using machine learning algorithm, which provides a fast and reliable way of reconstruction for an arbitrary configuration of the scanning beamline. In August 2024, we set up the diagnostic beamline to perform a quadrupole scan of the beam. The setup includes a skew quadrupole, a regular quadrupole, and a screen. The images on the screen were post-processed to remove experimental artifacts and enhance contrast by eliminating background noise outside the core of the distribution=. The rms parameters of the distribution were then calculated and used as inputs for the reconstruction algorithm. This algorithm attempts to determine the initial beam matrix that produces expected images on the screen closely matching the observed images across all quadrupole settings. The algorithm found a solution in which the expected rms parameters closely align with the observations. Validation of the results is planned for FY25.

43 PARTICLE ACCELERATORS↗

Optical alignment of high resolution Fourier transform spectrometers

Remote sensing, high resolution FTS instruments often contain three primary optical subsystems: Fore-Optics, Interferometer Optics, and Post, or Detector Optics. We discuss the alignment of a double-pass FTS containing a cat's-eye retro-reflector. Also, the alignment of fore-optics containing confocal paraboloids with a reflecting field stop which relays a field image onto a camera is discussed.

Breckinridge, J. B.↗

Very large ground-based telescopes for optical and IR astronomy

Methods for improving the light grasp by an order of magnitude for earth-based observations of astrophysical objects are reviewed. Noting that the atmosphere is opaque below 0.3 micron and that techniques have been developed to make corrections for the atmospheric distortion, fully diffraction limited IR performance at 10 microns is asserted to be practicable. The use of mirror-seeing with metal mirrors with thin faceplates and air cooling is outlined as a means to achieve subarcsec resolution. Designs are considered which involve multiple sections to gain effective large aperture viewing for spectroscopy, using Si CCD detectors, and heterodyne IR interferometry, but not for direct interferometry or certain IR measurements. The Multiple Mirror Telescope is described, including designs for four 7.5 m honeycomb glass primaries co-aligned in a single mount. Further discussion is devoted to the fabrication of mirror elements and electronic image stabilization.

Angel, J. R. P.↗

Observation of Individual Fluorine Atom from Highly Oriented Poly (tetrafluoroethylene) Films by Atomic Force Microscopy

Direct observation of the film thickness, molecular structure and individual fluorine atoms from highly oriented poly(tetrafluoroethylene) (PTFE) films were achieved using atomic force microscopy (AFM). A thin PTFE film is mechanically deposited onto a smooth glass substrate at specific temperatures by a friction transfer technique. Atomic resolution images of these films show that the chain-like helical structures of the PTFE macromolecules are aligned parallel to each other with an intermolecular spacing of 5.72 A, and individual fluorine atoms are clearly observed along these twisted molecular chains with an interatomic spacing of 2.75 A. Furthermore, the first direct AFM measurements for the radius of the fluorine-helix, and of the carbon-helix in sub-angstrom scale are reported as 1.70 A and 0.54 A respectively.

Lee, Jonathan A.,↗

Observation of Individual Fluorine Atoms from Highly Oriented Poly(Tetrafluoroethylene) Films by Atomic Force Microscopy

Direct observation of the film thickness, molecular structure, and individual fluorine atoms from highly oriented poly(tetrafluoroethylene) (PTFE) films were achieved using atomic force microscopy (AFM). A thin PTFE film is mechanically deposited onto a smooth glass substrate at specific temperatures by a friction-transfer technique. Atomic resolution images of these films show that the chain-like helical structures of the PTFE macromolecules are aligned parallel to each other with an intermolecular spacing of 5.72 A, and individual fluorine atoms are clearly observed along these twisted molecular chains with an interatomic spacing of 2.75 A. Furthermore, the first direct AFM measurements for the radius of the fluorine-helix, and of the carbon-helix in sub-angstrom scale are reported as 1.7 and 0.54 A respectively.

Lee, J. A.↗

Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects

An optical design is presented for a measurement system used to assess the impact of surface errors originating from diamond turning artifacts. Diamond turning artifacts are common by-products of optical surface shaping using the diamond turning process (a diamond-tipped cutting tool used in a lathe configuration). Assessing and evaluating the errors imparted by diamond turning (including other surface errors attributed to optical manufacturing techniques) can be problematic and generally requires the use of an optical interferometer. Commercial interferometers can be expensive when compared to the simple optical setup developed here, which is used in combination with an image-based sensing technique (phase retrieval). Phase retrieval is a general term used in optics to describe the estimation of optical imperfections or aberrations. This turnkey system uses only image-based data and has minimal hardware requirements. The system is straightforward to set up, easy to align, and can provide nanometer accuracy on the measurement of optical surface defects.

Dean, Bruce↗

C/NOFS Observations of Electromagnetic Coupling Between Magnetically Conjugate MSTID Structures

This report demonstrates empirically that couplings between magnetically conjugate medium-scale traveling ionospheric disturbances (MSTIDs) are electromagnetic in nature. This is accomplished by comparing plasma density, electric, and magnetic perturbations sampled simultaneously by sensors on the Communication Navigation Outage Forecasting System (CNOFS) satellite. During the period of interest on 17 February 2010, CNOFS made three consecutive orbits while magnetically conjugate to the field of view of an all-sky imager located at El Leoncito, Argentina (31.8degS, 69.3degW). Imaged 630.0 nm airglow was characterized by alternating bands of relatively bright and dark emissions that were aligned from northeast to southwest and propagated toward the northwest, characteristic of MSTIDs in the southern hemisphere. Measurable Poynting fluxes flow along the Earths magnetic field (S) from generator to load hemispheres. While S was predominantly away from the ionosphere above El Leoncito, interhemispheric energy flows were not one-way streets. Measured Poynting flux intensities diminished with time over the three CNOFS passes, suggesting that source mechanisms of MSTIDs were absent or that initial impedance mismatches between the two hemispheres approached an equilibrium status.

Burke, W. J.↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This paper presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the test section. Some icing spray clouds with large drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow in the measurement area of the probe between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a pitot-static probe affixed on the mounting plate next to the stand. Those findings were later verified in the Icing Research Tunnel using a new pitot-static probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations were performed with the airflow moving towards the probe head with a Langmuir-D 7-bin distribution cloud containing large drops. The simulation results helped identify a critical drop-size threshold of 300 μm above which the velocities of larger drops are negligibly affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This presentation presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the tunnel test section. Some icing spray clouds with large-sized drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a Pitot static probe affixed on the mounting plate. Those findings were later verified in the Icing Research Tunnel using a new Pitot probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations as airflow moving towards the probe head were run for a Langmuir-D 7-bin drop size distribution of a spray cloud with a nominally large value of medium volumetric diameter. The simulation results helped identify a critical drop-size threshold of 300 µm above which the velocities of larger drops are not affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Capability of ERTS-1 imagery to investigate geological and structural features in a sedimentary basin (Bassin Parisien, France)

The author has identified the following significant results. The region covered by the MSS images has the benefit of complete geological mapping at scales of 1:80,000, 1:320,000, and 1:1,000,000. Comparison of imagery and exisiting geological maps, particularly the 1:1,000,000 scale, produces important information: (1) Good correspondence is seen between large units distinguished on the images and the concentric strata of the Jurassic, Cretaceous, and Paleocene on the map. (2) Comparison of MSS images with the hydrogeological map of the Parisian basin at 1:500,000 removes all ambiguity with regard to lithological variations. Among the many faults revealed, only three were considered: (1) the Metz; (2)Juranze; and (3) the double fault of the Marne. Imagery shows a conspicuous alignment of the Metz fault unknown until now and ending near Montereau against the group of north-south faults between Montargis and Bourbon l'Archambault. MSS images show that the Juranze fault divides beyond Brienne into two branches of equal importance. The northern one represents the known fault, the southern one was not known until now, but the convergence of the faults constitutes a tectonic trap. The double fault of the Marne is known for a total length of 50 km. ERTS-1 imagery suggest a prolongation toward the southeast which could bring its length to 110 km.

Weecksteen, G.↗

The UAH Spinning Terrella Experiment: A Laboratory Analog for the Earth's Magnetosphere

The UAH Spinning Terrella Experiment has been modified to include the effect of a second magnet. This is a simple laboratory demonstration of the well-known double-dipole approximation to the Earth's magnetosphere. In addition, the magnet has been biassed $\sim$-400V which generates a DC glow discharge and traps it in a ring current around the magnet. This ring current is easily imaged with a digital camera and illustrates several significant topological properties of a dipole field. In particular, when the two dipoles are aligned, and therefore repel, they emulate a northward IMF Bz magnetosphere. Such a geometry traps plasma in the high latitude cusps as can be clearly seen in the movies. Likewise, when the two magnets are anti-aligned, they emulate a southward IMF Bz magnetosphere with direct feeding of plasma through the x-line. We present evidence for trapping and heating of the plasma, comparing the dipole-trapped ring current to the cusp-trapped population. We also present a peculiar asymmetric ring current produced in by the plasma at low plasma densities. We discuss the similarities and dissimilarities of the laboratory analog to the collisionless Earth plasma, and implications for the interpretation of IMAGE data.

Sheldon, R. B.↗