Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Jackson, L., Johnson, M.B., Latrach, A., Grimes, D., Martinez, C., and Mclaughlin, J.F., 2024, Multidisciplinary geotechnical data collection, curation, and analysis for conformity with the regulatory framework for geologic carbon storage in Wyoming, USA: Geological Society of America Abstracts with Programs. Vol. 56, No. 5, 2024, doi: 10.1130/abs/2024AM-405024

Title: Multidisciplinary Geotechnical Data Collection, Curation, and Analysis for Conformity with the Regulatory Framework for Geologic Carbon Storage in Wyoming, USA. Text: Construction and operation of wells for geologic sequestration of carbon dioxide necessitate that they are permitted under the Environmental Protection Agency’s Underground Injection Control Class VI requirements. Class VI wells conform to stringent requirements to ensure long-term safety and integrity of the storage site and the protection of Underground Sources of Drinking Water. Entities pursuing Class VI permitting must provide comprehensive geologic site characterization, including regional geologic structure and stratigraphy, aquifer information, reservoir and confining unit geomechanical properties, geochemical analyses, assessment of trapping capacity and mechanisms, and a variety of other of multidisciplinary geotechnical data. The Wyoming Class VI Site Characterization Database Project is focused on developing a geologic site characterization database of geotechnical information, which has been compiled and verified from established, public databases/entities and scientific literature to expedite Class VI permitting in Sweetwater County within the Greater Green River Basin of southern Wyoming. The preliminary suite of compiled data from 14,000 wells includes 8,000 wells with logs and 7,250 wells with formation tops, ~70 wells with core data (e.g., X-Ray diffraction, petrographic, and petrophysical data), ~2,500 water analyses, ~740 seismic events data, and ~520 bottom-hole temperature measurements. Future work on—and stemming from—this project will include new core analyses, calculation and interpolation of subsurface temperature gradients, mechanical earth models, geochemical simulations, storage capacity estimation, stratigraphic column generation and correlation, and construction of subsurface maps. Finally, this work will help to inspire and facilitate subsurface data compilation and curation beyond Sweetwater County, Wyoming.

42 ENGINEERING↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Electric vehicle batteries alone could satisfy short-term grid storage demand by as early as 2030

The energy transition will require a rapid deployment of renewable energy (RE) and electric vehicles (EVs) where other transit modes are unavailable. EV batteries could complement RE generation by providing short-term grid services. However, estimating the market opportunity requires an understanding of many socio-technical parameters and constraints. We quantify the global EV battery capacity available for grid storage using an integrated model incorporating future EV battery deployment, battery degradation, and market participation. We include both in-use and end-of-vehicle-life use phases and find a technical capacity of 32–62 terawatt-hours by 2050. Low participation rates of 12%–43% are needed to provide short-term grid storage demand globally. Participation rates fall below 10% if half of EV batteries at end-of-vehicle-life are used as stationary storage. Short-term grid storage demand could be met as early as 2030 across most regions. Our estimates are generally conservative and offer a lower bound of future opportunities.

25 ENERGY STORAGE↗

Relationship between clay minerals and microorganisms in underground hydrogen storage reservoirs: a mini review

Hydrogen (H 2 ) will play a vital role in the global shift towards sustainable energy systems. Due to the high cost and challenges associated with storing hydrogen in large quantities for industrial applications, Underground Hydrogen Storage (UHS) in geological formations has emerged as a promising solution. Clay minerals, abundant in subsurface environments, play a critical role in UHS by providing low permeability, cation exchange capacity, and stability, essential for preventing hydrogen leakage. However, microorganisms in the subsurface, particularly hydrogenotrophic species, interact with clay minerals in ways that can affect the integrity of these storage systems. Microbes form biofilms on clay surfaces, which can cause pore clogging and reduce the permeability of the reservoir, potentially stabilizing H 2 storage and limiting injectivity. Microbial-induced chemical weathering, through the production of organic acids and redox reactions, can degrade clay minerals, releasing metal ions and destabilizing the storage site. These interactions raise concerns about the long-term storage capacity of UHS, as microbial processes could lead to H 2 loss and caprock degradation, compromising the storage system’s effectiveness. This mini review aims to cover the current understanding of the interactions between clay minerals and microorganisms and how these dynamics can affect the safe and sustainable deployment of UHS .

Clark, Allison↗

West Africa Battery Energy Storage Systems (BESS) Capacity Building - Discussion of BESS Tariffs: Payment Structures and Case Studies [Slides]

Battery Energy Storage Systems (BESS) are emerging as critical assets for enhancing grid reliability, integrating renewable energy, and enabling system flexibility. Yet, the regulatory and financial frameworks that determine how BESS projects are compensated vary widely across jurisdictions. This presentation explores international case studies - from Honduras, Costa Rica, Chile, South Africa, Mexico, and Brazil - to illustrate how tariff design and payment structures are evolving to support large-scale BESS deployment. The cases highlight a range of ownership and revenue models, including cost-of-service mechanisms, energy and capacity payments, and market-based arbitrage, as well as hybrid approaches under development. The discussion will examine key challenges such as defining remuneration for ancillary services, addressing double charging, and accounting for efficiency losses and degradation over time. By comparing experiences across markets, the presentation identifies emerging best practices for valuing BESS and designing tariffs that align technical performance with economic incentives, providing insights for regulators, utilities, and policymakers pursuing storage integration.

25 ENERGY STORAGE↗

Shaker Table Test Plan

Currently, spent nuclear fuel (SNF) is stored in onsite independent spent fuel storage facilities (ISFSIs), which is a dry storage facility, at 55 nuclear power plant sites. The majority of SNF in dry storage is in welded metal canisters (2,917 canisters at the end of 2019). The canisters are loaded for storage in storage overpacks (vertical casks or horizontal storage modules) and placed on outdoor concrete pads. Because the SNF will be stored at ISFSIs for an extended period of time, there is growing concern with regards to the behavior of the SNF within these dry storage systems during earthquakes. To address these concerns, the SFWST program is considering conducting an earthquake shaker table test. The goal of this test is to determine the strains and accelerations on fuel assembly hardware and cladding during earthquakes of different magnitudes to better quantify the potential damage an earthquake could inflict on spent nuclear fuel rods. The seismic integrity of the storage system has been addressed in the past by the US Nuclear Regulatory Commission and is not the focus of this potential test. Instead the DOE would benefit from knowing the condition of the fuel cladding from storage, transportation, to disposal so that it can ascertain repository performance for the fuel and packaging in its final state. A seismic event is part of the possible loading events that the fuel could experience in its lifetime. This report proposes several earthquake shaker table tests with different degrees of complexity. Alternative 1 was defined in the FY20 work scope. Alternatives 2 and 3 were recently developed to take advantage of the NUHOMS 32PTH dry storage canister that may be available in FY21 for this test at a minimum cost to the project. The selection of the alternative(s) will depend on the available budget and the SFWST program priorities for the near future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overcoming Data Scarcity in Carbon Storage Assessment: Estimating Petrophysical Properties in Legacy Wells Integrating Sample Logs and Geostatistical Approaches

Geological CO2 sequestration feasibility studies in mature basins frequently face challenges associated with legacy well data, which often lack the comprehensive logging suites required for accurate reservoir characterization. This study evaluates the storage potential of Ordovician– Devonian formations in a filed in the Delaware Basin portion of the Permian Basin, using a dataset of 47 wells.

58 GEOSCIENCES↗

Evaluating the Impacts of the Bipartisan Budget Act of 2018 45Q Tax Credit on CCS Network Costs

This study evaluates the impact of the Bipartisan Budget Act of 2018 (BBA)-amended 45Q tax credit on integrated carbon capture and storage (CCS) networks for source types and geologic storage reservoirs common to the north-central U.S. The integrated CCS networks evaluated were chosen to closely replicate those in the forthcoming National Energy Technology Laboratory (NETL) central U.S. CCS cost options study’s Northwest CCS Network Regional Impact Area (Northwest Impact Area).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling the Write-Once Read-Many (WORM) Dashboard and Web Interface for HPC Data Storage

Idaho National Laboratory (INL), supported by the Department of Energy Office of Nuclear Energy (DOE-NE) through the Nuclear Science User Facilities, provides access to supercomputer systems and data storage along with support staff for system management, software installation, cybersecurity, and user support to the broader DOE-NE user community. A key component of this is providing long-term or perpetual data storage as part of efforts to improve reproducibility in modeling and simulation in addition to supporting simulations with regulatory compliance requirements. This milestone details the deployment of a new type of storage option for users requiring tamper resistant perpetual storage of data and the associated support for data control and release via the data storage web interface. The perpetual data storage system is integrated within the Open OnDemand framework deployed at INL and is called the ?WORM? in recognition of its write-once read-many characteristics.

99 GENERAL AND MISCELLANEOUS↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

A Software/Hardware Framework for Efficient and Safe Emergency Response in Post-Crash Scenarios of Battery Electric Vehicles

The adoption rate of battery electric vehicles (EVs) is rapidly increasing. Electric vehicles differ significantly from conventional internal combustion engine vehicles and vary widely across different manufacturers. Emergency responders (ERs) and recovery personnel may have less experience with EVs and lack timely access to critical information such as the extent of the stranded energy present, high-voltage safety hazards, and post-crash handling procedures in a user-friendly manner. This paper presents a software/hardware interactive tool named Electric Vehicle Information for Incident Response Solutions (EVIRS) to aid in the quick access to emergency response and recovery information. The current prototype of EVIRS identifies EVs using the VIN or Make, Model, and Year, and offers several useful features for ERs and recovery personnel. These features include integration and easy access to emergency response procedures tailored to an identified EV, vehicle structural schematics, the quick identification of battery pack specifications, and more. For EVs that are not severely damaged, EVIRS can perform calculations to estimate stranded energy in the EV’s battery and discharge time for various power loads using either EV dashboard information or operational data accessed through the CAN interface. Knowledge of this information may be helpful in the post-crash handling, management, and storage of an EV. The functionality and accuracy of EVIRS were demonstrated through laboratory tests using a 2021 Ford Mach-E and associated data acquisition system. The results indicated that when the remaining driving range was used as an input, EVIRS was able to estimate the pack voltage with an error of less than 3 V. Conversely, when pack voltage was used as an input, the estimated state of charge (SOC) error was less than 5% within the range of 30–90% SOC. Additionally, other features, such as retrieving emergency response guides for identified EVs and accessing lessons learned from archived incidents, have been successfully demonstrated through EVIRS for quick access. EVIRS can be a valuable tool for emergency responders and recovery personnel, both in action and during offline training, by providing crucial information related to assessing EV/battery safety risks, appropriate handling, de-energizing, transport, and storage in an integrated and user-friendly manner.

25 ENERGY STORAGE↗

Historical Hydropower Operations and Economic Value

This report on historical hydropower operations and economic value focuses primarily on addressing HydroWIRES Objective 1.3: Advance valuation of conventional and pumped-storage hydropower assets. It is informed by previous work performed by Argonne and other national laboratories on the modeling and analysis of value of pumped storage and conventional hydropower. The results from this report will feed into the new projects that are planned under the HydroWIRES initiative and that will examine hydropower’s value in providing grid reliability and resilience, as well as in improving the modeling and representation of hydropower in power system models. Other relevant DOE efforts include various WPTO-funded projects, such as the Beyond Levelized Cost of Energy Project and Integrated Hydropower and Storage Systems, that are currently addressing similar challenges associated with defining grid service values that arise from hydropower machine capabilities.

13 HYDRO ENERGY↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗

Microbial carbon limitation: The need for integrating microorganisms into our understanding of ecosystem carbon cycling

Abstract Numerous studies have demonstrated that fertilization with nutrients such as nitrogen, phosphorus, and potassium increases plant productivity in both natural and managed ecosystems, demonstrating that primary productivity is nutrient limited in most terrestrial ecosystems. In contrast, it has been demonstrated that heterotrophic microbial communities in soil are primarily limited by organic carbon or energy. While this concept of contrasting limitations, that is, microbial carbon and plant nutrient limitation, is based on strong evidence that we review in this paper, it is often ignored in discussions of ecosystem response to global environment changes. The plant‐centric perspective has equated plant nutrient limitations with those of whole ecosystems, thereby ignoring the important role of the heterotrophs responsible for soil decomposition in driving ecosystem carbon storage. To truly integrate carbon and nutrient cycles in ecosystem science, we must account for the fact that while plant productivity may be nutrient limited, the secondary productivity by heterotrophic communities is inherently carbon limited. Ecosystem carbon cycling integrates the independent physiological responses of its individual components, as well as tightly coupled exchanges between autotrophs and heterotrophs. To the extent that the interacting autotrophic and heterotrophic processes are controlled by organisms that are limited by nutrient versus carbon accessibility, respectively, we propose that ecosystems by definition cannot be ‘limited’ by nutrients or carbon alone. Here, we outline how models aimed at predicting non‐steady state ecosystem responses over time can benefit from dissecting ecosystems into the organismal components and their inherent limitations to better represent plant–microbe interactions in coupled carbon and nutrient models.

Soong, Jennifer L.↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

February 2020 Bayou Choctaw Subsidence Analysis

Subsidence monitoring is a crucial component to understanding cavern integrity of salt storage caverns. This report looks at the historical and current subsidence monitoring program and includes interpretation of the data from the Bayou Choctaw Strategic Petroleum Reserve site. The current monitoring program consists of an annual elevation survey as well as GPS and tiltmeter instruments above both Cavern 4 and Cavern 20. This year's level and rod survey indicates little subsidence across the site. In addition, the GPS and tiltmeter instruments do not indicate any substantial movement above caverns 4 and 20. As such, there is no reason to indicate any of the caverns at Bayou Choctaw have lost integrity.

02 PETROLEUM↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

United States Nuclear Power Reactor Used Nuclear Fuel Database and Applications

The Unified Database (UDB) within STANDARDS serves as the foundational data infrastructure for managing the United States' spent nuclear fuel inventory of 315,111 discharged assemblies totaling 91,036 metric tons of heavy metal. The database organizes this complex inventory through over 200 interconnected tables structured into eight primary attribute categories, supporting integrated analyses across storage, transportation, and disposal domains. Data enters the UDB through the GC-859 Nuclear Fuel Data Survey, which transitioned to web-based collection in 2023, improving data quality through real-time validation. The UDB enables automated generation of input files for nuclear safety analyses, reducing preparation time from weeks to hours while maintaining traceability. Applications include national inventory reporting, Certificate of Compliance assessments, and facility optimization. The three-tier distribution model balances accessibility with security requirements for federal agencies, national laboratories, and research organizations. The UDB provides essential data infrastructure as spent fuel management transitions from site-specific to integrated national campaigns.

Stefanovic, Peter↗