Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometry.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Biphoton spectral quantum interference for information processing and delay metrology

Broadband time-energy entangled photons feature strong temporal correlations with potential for precision delay metrology, but previous work has leveraged only time-of-flight information ultimately limited by the detection jitter and resolution of the time-tagging electronics. Firstly, our work pushes the entanglement-based nonlocal delay metrology from the conventional time-of-flight measurement to a new direction—two-photon interferometry with subpicosecond sensitivity independent of detection resolution. Next, we show the selective sensitivity of frequency-bin encoded Bell states to the sum and difference of biphoton-delays by using a novel reconfigurable setup capable of switching between the Bell states by successively employing single and dual spectral-line pumps.

Seshadri, Suparna↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

The Role of Laser Wavelength on the Early-stage Electron Density Evolution in Laser-Produced Plasma

In this study, a laser-produced plasma (LPP) was generated by focusing fundamental (1064 nm), second (532nm), and fourth (266 nm) harmonic radiation from a 6 ns Nd:YAG laser at a laser intensity of 10 GW/cm2 onto a copper target placed in vacuum. The early time evolution of the plasma between 0-70 ns following laser ablation was then analyzed using Nomarski interferometry. The dependence of plasma properties such as the electron density distribution, plume velocity, and plume morphology on the laser wavelength are discussed.

(280.5395) Plasma Diagnostics, (140.3440) Laser-in↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

TiO 2 Nanocoatings with Controllable Crystal Type and Nanoscale Topography on Zirconia Implants to Accelerate Bone Formation

In dentistry, zirconia implants have emerged as a promising alternative for replacing missing teeth due to their superior aesthetic performance and chemical stability. To improve the osseointegration of zirconia implants, modifying their surface with hierarchical micro/nanotopography and bioactive chemical composition are two effective ways. In this work, a microscale topography was prepared on a zirconia surface using hydrofluoric acid etching, and then a 50 nm TiO 2 nanocoating was deposited via atomic layer deposition (ALD). Subsequently, an annealing treatment was used to transform the TiO 2 from amorphous to anatase and simultaneously generate nanoscale topography. Various investigations into the coating surface morphology, topography, wettability, and chemical composition were carried out using scanning electron microscopy, white light interferometry, contact‐angle measurement, X‐ray diffraction, and X‐ray photoelectron spectroscopy. In addition, in vitro cytocompatibility and osteogenic potential performance of the coatings were evaluated by human bone marrow mesenchymal stem cells (hBMSCs), and in vivo osseointegration performance was assessed in a rat femoral condyle model. Moreover, the possible mechanism was also investigated. The deposition of TiO 2 film with/without annealing treatment did not alter the microscale roughness of the zirconia surface, whereas the nanotopography changed significantly after annealing. The in vitro studies revealed that the anatase TiO 2 coating with regular wavelike nanostructure could promote the adhesion and proliferation of osteoblasts and further improve the osteogenic potential in vitro and osseointegration in vivo. These positive effects may be caused by nanoscale topography via the canonical Wnt/ β ‐catenin pathway. The results suggest that using ALD in combination with annealing treatment to fabricate a nanotopographic TiO 2 coating is a promising way to improve the osteogenic properties of zirconia implants.

Li, Nan (ORCID:0000000255156737)↗

SAXS analysis of the intrinsic tenase complex bound to a lipid nanodisc highlights intermolecular contacts between factors VIIIa/IXa

Abstract The intrinsic tenase (Xase) complex, formed by factors (f) VIIIa and fIXa, forms on activated platelet surfaces and catalyzes the activation of factor X to Xa, stimulating thrombin production in the blood coagulation cascade. The structural organization of the membrane-bound Xase complex remains largely unknown, hindering our understanding of the structural underpinnings that guide Xase complex assembly. Here, we aimed to characterize the Xase complex bound to a lipid nanodisc with biolayer interferometry (BLI), Michaelis–Menten kinetics, and small-angle X-ray scattering (SAXS). Using immobilized lipid nanodiscs, we measured binding rates and nanomolar affinities for fVIIIa, fIXa, and the Xase complex. Enzyme kinetic measurements demonstrated the assembly of an active enzyme complex in the presence of lipid nanodiscs. An ab initio molecular envelope of the nanodisc-bound Xase complex allowed us to computationally model fVIIIa and fIXa docked onto a flexible lipid membrane and identify protein–protein interactions. Our results highlight multiple points of contact between fVIIIa and fIXa, including a novel interaction with fIXa at the fVIIIa A1–A3 domain interface. Lastly, we identified hemophilia A/B-related mutations with varying severities at the fVIIIa/fIXa interface that may regulate Xase complex assembly. Together, our results support the use of SAXS as an emergent tool to investigate the membrane-bound Xase complex and illustrate how mutations at the fVIIIa/fIXa dimer interface may disrupt or stabilize the activated enzyme complex.

Hematology↗

Proposal for a quantum random number generator using coherent light and a non-classical observable

The prototype quantum random number (random bit) generator (QRNG) consists of one photon at a time falling on a 50:50 beam splitter followed by random detection in one or the other output beams due to the irreducible probabilistic nature of quantum mechanics. Due to the difficulties in producing single photons on demand, in practice, pulses of weak coherent (laser) light are used. In this paper, we take a different approach, one that uses moderate coherent light. It is shown that a QRNG can be implemented by performing photon-number parity measurements. For moderate coherent light, the probabilities of obtaining even or odd parity in photon counts are 0.5 each. Photon counting with single-photon resolution can be performed through use of a cascade of beam splitters and single-photon detectors, as was done recently in a photon-number parity-based interferometry experiment involving coherent light. We highlight the point that unlike most quantum-based random number generators, our proposal does not require the use of classical de-biasing algorithms or post-processing of the generated bit sequence.

Gerry, Christopher C.↗

Multiplexable high-temperature stable and low-loss intrinsic Fabry-Perot in-fiber sensors through nanograting engineering

This paper presents a method of using femtosecond laser inscribed nanograting as low-loss– and high-temperature–stable in-fiber reflectors. By introducing a pair of nanograting inside the core of a single-mode optical fiber, an intrinsic Fabry-Perot interferometer can be created for high-temperature sensing applications. The morphology of the nanograting inscribed in fiber cores was engineered by tuning the fabrication conditions to achieve a high fringe visibility of 0.49 and low insertion loss of 0.002 dB per sensor. Using a white light interferometry demodulation algorithm, we demonstrate the temperature sensitivity, cross-talk, and spatial multiplexability of sensor arrays. Both the sensor performance and stability were studied from room temperature to 1000°C with cyclic heating and cooling. Our results demonstrate a femtosecond direct laser writing technique capable of producing highly multiplexable in-fiber intrinsic Fabry-Perot interferometer sensor devices with high fringe contrast, high sensitivity, and low-loss for application in harsh environmental conditions.

Wang, Mohan (ORCID:0000000166784993)↗

Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry

Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

47 OTHER INSTRUMENTATION↗

Ultrabroadband flying-focus using an axiparabola-echelon pair

Flying-focus pulses promise to revolutionize laser-driven secondary sources by decoupling the trajectory of the peak intensity from the native group velocity of the medium over distances much longer than a Rayleigh range. Previous demonstrations of the flying focus have either produced an uncontrolled trajectory or a trajectory that is engineered using chromatic methods that limit the duration of the peak intensity to picosecond scales. Here we demonstrate a controllable ultrabroadband flying focus using a nearly achromatic axiparabola-echelon pair. Spectral interferometry using an ultrabroadband superluminescent diode was used to measure designed super- and subluminal flying-focus trajectories and the effective temporal pulse duration as inferred from the measured spectral phase. The measurements demonstrate that a nearly transform- and diffraction-limited moving focus can be created over a centimeter-scale—an extended focal region more than 50 Rayleigh ranges in length. This ultrabroadband flying-focus and the novel axiparabola-echelon configuration used to produce it are ideally suited for applications and scalable to >100 TW peak powers.

47 OTHER INSTRUMENTATION↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Reflective binary amplitude grating for soft x-ray shearing and Hartmann wavefront sensing

Here, we demonstrate a reflective wavefront sensor grating suitable for the characterization of high-quality x-ray beamlines and optical systems with high power densities. Operating at glancing incidence angles, the optical element is deeply etched with a two-level pattern of shearing interferometry gratings and Hartmann wavefront sensor grids. Transverse features block unwanted light, enabling binary amplitude in reflection with high pattern contrast. We present surface characterization and soft x-ray reflectometry of a prototype grating array to demonstrate function prior to wavefront measurement applications. A simulation of device performance is shown.

47 OTHER INSTRUMENTATION↗

Pseudo-gray-scale halftone gratings for shearing and Hartmann wavefront sensors

Now in use on x-ray beamlines worldwide, shearing interferometry and Hartmann wavefront sensing provide effective feedback for measuring and optimizing high-quality beams. Conventionally, both approaches spatially modulate the beam properties (amplitude or phase) using two-tone, binary patterns, leading to deleterious diffraction effects that must be mitigated. In shearing, the presence of multiple diffraction orders affects measurement near boundaries. In Hartmann, diffraction limits the measurement point density. We demonstrate that the use of pseudo-gray-scale halftone patterns in the diffracting elements can improve the performance of both techniques.

47 OTHER INSTRUMENTATION↗

Single-shot observation of nonlinear pulse splitting in a Kerr medium

We report single-shot, time-resolved observation of self-steepening and temporal splitting of near-infrared, 50 fs, micro-joule pulses propagating nonlinearly in flint (SF11) glass. A coherent, smooth-profiled, 60-nm-bandwidth probe pulse that propagated obliquely to the main pulse through the Kerr medium recorded a time sequence of longitudinal projections of the main pulse’s induced refractive index profile in the form of a phase-shift “streak,” in which frequency–domain interferometry recovered with ∼10 fs temporal resolution. A three-dimensional simulation based on a unidirectional pulse propagation equation reproduced observed pulse profiles.

Chang, Yen-Yu↗

Rapidly tunable ultrabroadband flying focus using adaptive optics and an axiparabola

A programmable ultrabroadband flying focus was produced using adaptive optics and an axiparabola with a continuous wave superluminescent diode. A deformable mirror and spatial light modulator were used to add a programmable amount of radial group delay, and an axiparabola was used to create an extended focus by imparting spherical aberration. Three different flying focus trajectories were measured using spectral interferometry, two with uniform velocity and one with an accelerating velocity. Here, the temporal response function width of the flying focus optics alone was calculated to be 52 ± 6 fs, and the focal spot size was measured to be (1.2 ± 0.1) × larger than the diffraction-limited spot size through the extended focus.

Markland, H. S. [University of Rochester, NY (Unit↗

Information transfer as a framework for optimized phase imaging

In order to efficiently image a non-absorbing sample (a phase object), dedicated phase contrast optics are required. Typically, these optics are designed with the assumption that the sample is weakly scattering, implying a linear relation between a sample’s phase and its transmission function. In the strongly scattering, nonlinear case, the standard optics are ineffective, and the transfer functions used to characterize them are uninformative. We use the Fisher information (FI) to assess the efficiency of various phase imaging schemes and to calculate an information transfer function (ITF). We show that a generalized version of Zernike phase contrast is efficient given sufficient prior knowledge of the sample. We show that with no prior knowledge, a random sensing measurement yields a significant fraction of the available information. Finally, we introduce a generalized approach to common path interferometry that can be optimized to prioritize sensitivity to particular sample features. Each of these measurements can be performed using Fourier lenses and phase masks.

Koppell, Stewart↗