Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Infrared Pulse-laser Long-path Absorption Measurement of Carbon Dioxide Using a Raman-shifted Dye Laser

A pulsed laser source is effective in infrared laser long-path absorption measurements when the optical path length is very long or the reflection from a hard target is utilized, because higher signal-to-noise ratio is obtained in the detection of weak return signals. We have investigated the performance of a pulse-laser long-path absorption system using a hydrogen Raman shifter and a tunable dye laser pumped by a Nd:YAG laser, which generates second Stokes radiation in the 2-micron region.

Minato, Atsushi↗

Tunable diode laser measurements of HO2NO2 absorption coefficients near 12.5 microns

A tunable diode laser spectrometer has been used to measure absorption coefficients of peroxynitric acid (HO2NO2) near the 803/cm Q branch. HO2NO2 concentrations in a low-pressure flowing gas mixture were determined from chemical titration procedures and UV absorption spectroscopy. The diode laser measured absorption coefficients, at a spectral resolution of better than 0.001/cm, are about 10 percent larger than previous Fourier transform infrared measurements made at a spectral resolution of 0.06/cm.

May, R. D.↗

Accurate quantum yields by laser gain vs absorption spectroscopy - Investigation of Br/Br(asterisk) channels in photofragmentation of Br2 and IBr

Various techniques have been used to study photodissociation dynamics of the halogens and interhalogens. The quantum yields obtained by these techniques differ widely. The present investigation is concerned with a qualitatively new approach for obtaining highly accurate quantum yields for electronically excited states. This approach makes it possible to obtain an accuracy of 1 percent to 3 percent. It is shown that measurement of the initial transient gain/absorption vs the final absorption in a single time-resolved signal is a very accurate technique in the study of absolute branching fractions in photodissociation. The new technique is found to be insensitive to pulse and probe laser characteristics, molecular absorption cross sections, and absolute precursor density.

Haugen, H. K.↗

Absolute 1* quantum yields for the ICN A state by diode laser gain versus absorption spectroscopy

Absolute I* quantum yields were measured as a function of wavelength for room temperature photodissociation of the ICN A state continuum. The temperature yields are obtained by the technique of time-resolved diode laser gain-versus-absorption spectroscopy. Quantum yields are evaluated at seven wavelengths from 248 to 284 nm. The yield at 266 nm is 66.0 +/- 2% and it falls off to 53.4 +/- 2% and 44.0 +/- 4% at 284 and 248 respectively. The latter values are significantly higher than those obtained by previous workers using infrared fluorescence. Estimates of I* quantum yields obtained from analysis of CN photofragment rotational distributions, as discussed by other workers, are in good agreement with the I* yields. The results are considered in conjunction with recent theoretical and experimental work on the CN rotational distributions and with previous I* yield results.

Hess, Wayne P.↗

Early- and late-time dynamics of laser-produced plasmas by combining emission and absorption spectroscopy

Optical emission spectroscopy and laser absorption spectroscopy are two highly complementary techniques for diagnosing plasmas, specifically in the determination of important parameters such as temperature and density. In this work, we characterized a laser-produced plasma by combining emission and tunable absorption spectroscopy. Plasmas are produced by focusing pulses from a frequency quadrupled Nd:YAG laser onto a glass target containing a minor concentration of aluminum in an ambient atmosphere of ~100 Torr N 2 . Here, emission spectroscopy is used to investigate the line behavior of Al and Ca, electron density, and excitation temperature at times = 5 μs, while absorption spectroscopy is used to investigate the line behavior of Al and Ca, species density, and kinetic temperature at times = 5-100 μs. A comparison is made between the excitation temperature measured from emission using the Boltzmann plot method and the kinetic temperature measured from absorption; the implications of this comparison on local thermodynamic equilibrium and line-of-sight averaging are discussed. By combining the two methods of optical emission and laser absorption spectroscopy, a comprehensive characterization of the plasma over the entire lifetime of its evolution is possible, leading to a greater understanding of the plasma behavior including particle condensation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CBET-induced nonuniformity in direct-drive implosions on OMEGA [Slides]

Three dimensional polarization-dependent CBET plus beam balance and pointing are required to model nonuniformity in direct-drive implosions on OMEGA. Uniform laser energy absorption is essential for successful laser-direct-drive inertial confinement fusion but a growing body of evidence suggests OMEGA implosions are more asymmetric than predictions. By measuring the intensity and polarization of light scattered from individual beams, we have identified OMEGA’s polarization smoothing via distributed polarization rotators (DPR’s) as one previously unrealized source of nonuniformity. Polarization-dependent CBET along with beam energy balance, and beam pointing require three-dimensional modeling. Laser absorption mode 1 predictions from a fully three-dimensional CBET model correlate well with the observed direction of the core flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal evolution of emission and absorption signatures in a laser-produced plasma

Here we report spatiotemporal evolution of emission and absorption signatures of Al species in a nanosecond (ns) laser-produced plasma (LPP). The plasmas were generated from an Inconel target, which contained ~0:4 wt. % Al, using 1064 nm, ≈6 ns full width half maximum pulses from an Nd:YAG laser at an Ar cover gas pressure of ≈34 Torr. The temporal distributions of the Al I (394.4 nm) transition were collected from various spatial points within the plasma employing time-of-flight (TOF) emission and laser absorption spectroscopy, and they provide kinetics of the excited state and ground state population of the selected transition. The emission and absorption signatures showed multiple peaks in their temporal profiles, although they appeared at different spatial locations and times after the plasma onset. The absorption temporal profiles showed an early time signature representing shock wave propagation into the ambient gas. We also used emission and absorption spectral features for measuring various physical properties of the plasma. The absorption spectral profiles are utilized for measuring linewidths, column density, and kinetic temperature, while emission spectra were used to measure excitation temperature. A comparison between excitation and kinetic temperature was made at various spatial points in the plasma. Our results highlight that the TOF measurements provide a resourceful tool for showing the spatiotemporal LPP dynamics with higher spatial and temporal resolution than is possible with spectral measurements but are difficult to interpret without additional information on excitation temperatures and linewidths. The combination of absorption and emission TOF and spectral measurements thus provides a more complete picture of LPP spatiotemporal dynamics than is possible using any one technique alone.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Measurement of tropospheric OH by laser long-path absorption spectroscopy

OH-radicals are measured by laser long-path absorption spectroscopy. A tunable Nd:YAG/dye laser system provides broadbanded light at 308 nm. The beam is expanded to 0.3 m and pointed to an array of retroreflectors placed at a distance of 2800 m. The returning beam is separated from the outgoing beam and focused into a spectrometer of 0.3 pm resolution. A 1024 element diode array is used as a detector. The signal is digitized by a 14 bit analog to digital converter. The ultimate aim is a detection limit of 10(exp 5) molecules cm(exp -3) of OH. However the measurements in 1991 allowed only the recognition of OH absorptions corresponding to 3 x 10(exp 6) OH cm(exp -3) with a signal to noise ratio of two. Improvements of the instrument are under way. The advantages of the DOAS method are: the accuracy of detection is guaranteed because loss of OH radicals within the device is avoided, the rate of OH production by the device is negligible, and absorptions of other trace gases could be corrected for; and the calibration procedure for the device is fast and easy. The disadvantages of the system are: time resolution is about minutes because about ten spectra had to be added to keep the noise level down, the OH concentration is averaged along the whole light path, weight (500 kg) and size (4x4 m) of the device; and approximately 10 l/min of coolant and supply of 8 kW electrical power are necessary.

Kraft, Michael↗

High laser fluence ITO coatings utilizing a Fabry-Perot thin film filter to reduce effective absorption

Laser-induced damage threshold of transparent conductors, such as Indium Tin Oxide (ITO), is limited by their high optical absorption due to free carriers. However, the effective absorption of a transparent conductor thin film can be reduced by an order of magnitude, without changing the electrical characteristics of the film, when placed in a low electric field section of a multilayer coating. A Fabry-Perot thin film interference filter has both high transmittance and low electric field positions, so it is an ideal thin film structure for this application. Although Fabry-Perot interference filters are not known as particularly high laser-induced damage resistant coatings due to their resonant characteristics, a laser-induced damage threshold (LIDT) improvement of up to 8× was observed with this technique compared to single layer ITO coatings fabricated using either radio frequency magnetron sputtering or electron-beam deposition. Additionally, an approximately 4× LIDT improvement for a Fabry-Perot interference filter has been observed by the addition of ITO into the multilayer structure.

47 OTHER INSTRUMENTATION↗

Methane overtone absorption by intracavity laser spectroscopy

Interpretation of planetary methane (CH4) visible-near IR spectra, used to develop models of planetary atmospheres, has been hampered by a lack of suitable laboratory spectroscopic data. The particular CH4 spectral bands are due to intrinsically weak, high overtone-combination transitions too complex for classical spectroscopic analysis. The traditional multipass cell approach to measuring spectra of weakly absorbing species is insufficiently sensitive to yield reliable results for some of the weakest CH4 absorption features and is difficult to apply at the temperatures of the planetary environments. A time modulated form of intracavity laser spectroscopy (ILS), has been shown to provide effective absorption pathlengths of 100 to 200 km with sample cells less than 1 m long. The optical physics governing this technique and the experimental parameters important for obtaining reliable, quantitative results are now well understood. Quantitative data for CH4 absorption obtained by ILS have been reported recently. Illustrative ILS data for CH4 absorption in the 619.7 nm and 681.9 nm bands are presented. New ILS facilities at UM-St. Louis will be used to measure CH4 absorption in the 700 to 1000 nm region under conditions appropriate to the planetary atmospheres.

Obrien, James J.↗

Absorption of CO2-laser radiation in a hypocycloidal-pinch plasma

Absorption of a 50-J pulsed CO2 laser beam in the plasma produced in a hypocycloidal-pinch apparatus was studied. The apparatus consists of three disk electrodes with a 5-cm hole on the axis. The current sheets are snow-plowed toward the center of the hole to produce a plasma with a density greater than 10 to the 18th/cu cm and a temperature near 1 keV which emits soft X rays for 5 microsec. IR detectors measured the laser radiation incident onto, transmitted through, and scattered from the plasma as functions of time. For a period up to 70 microsec from the onset of X-ray emission, neither transmitted nor scattered laser radiation was observed above the detector threshold of 0.3% of the incident flux. This indicates effective absorption of the laser beam (greater than 99%) and that the particle confinement time extends far beyond the energy confinement time of 5 microsec. Thus, the plasma in this apparatus appears much more amenable to laser heating than that in a theta pinch.

Lee, J. H.↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗

Laser modulation of optical absorption in ZnSe

The possibility of producing and detecting laser induced modulation of absorption (LIMA) in ZnSe crystals using a moderate laser intensity of about 6 mw output was investigated. The modulation is smaller than that previously obtained with higher laser photon flux, but is not too difficult to detect. Modulation of the order of a few parts in 10 to the 5th power, up to one part in 10 to the 4th power appears typical at the present. LIMA pulse shapes were recorded with varying system resolutions at a half dozen wavelengths in the visible, from 4800 A to 6000 A. Detailed data were taken, particularly at 5000 A, for a range of time intervals following laser pulse turn-on. Quantitative study of the excitation and decay kinetics of these is underway, though analysis is not complete. Major features are discussed with attention centered upon the detailed measurements made most recently at 5000 A.

Major, R. W.↗

Rate constant for the reaction NH2 + NO from 216 to 480 K

The absolute rate constant was measured by the technique of flash photolysis-laser induced fluorescence (FP-LIF). NH2 radicals were produced by the flash photolysis of ammonia and the fluorescent NH2 photons were measured by multiscaling techniques. At each temperature, the results were independent of variations in total pressure, and flash intensity. The results are compared with previous determinations using the techniques of mass spectrometry, absorption spectroscopy, laser absorption spectroscopy, and laser induced fluorescence. The implications of the results are discussed with regard to combustion, post combustion, and atmospheric chemistry. The results are also discussed theoretically.

Stief, L. J.↗

Automatic Locking of Laser Frequency to an Absorption Peak

An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that constantly adjusts the frequency in an effort to drive the error to zero. When the laser frequency deviates from the midpeak value but remains within the locking range, the magnitude and sign of the error signal indicate the amount of detuning and the control circuitry adjusts the frequency by what it estimates to be the negative of this amount in an effort to bring the error to zero.

Koch, Grady J.↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗