Search NASA⌕ Search

SEARCH · Search NASA

Results for “likelihood estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Planck 2018 results - VIII. Gravitational lensing

We present measurements of the cosmic microwave background (CMB) lensing potential using the final Planck 2018 temperature and polarization data. Using polarization maps filtered to account for the noise anisotropy, we increase the significance of the detection of lensing in the polarization maps from 5σ to 9σ. Combined with temperature, lensing is detected at 40σ. We present an extensive set of tests of the robustness of the lensing-potential power spectrum, and construct a minimum-variance estimator likelihood over lensing multipoles 8 ≤ L ≤ 400 (extending the range to lower L compared to 2015), which we use to constrain cosmological parameters. We find good consistency between lensing constraints and the results from the Planck CMB power spectra within the ΛCDM model. Combined with baryon density and other weak priors, the lensing analysis alone constrains σ 8 Ωm 0.25 = 0.589 ± 0.020 (1σ errors). Also combining with baryon acoustic oscillation data, we find tight individual parameter constraints, σ8 = 0.811 ± 0.019, H0 = 67.9-1.3+1.2 km s -1 Mpc -1 , and Ω m = 0.303 -0.018 +0.016 . Combining with Planck CMB power spectrum data, we measure σ 8 to better than 1% precision, finding σ 8 = 0.811 ± 0.006. CMB lensing reconstruction data are complementary to galaxy lensing data at lower redshift, having a different degeneracy direction in σ 8 - Ω m space; we find consistency with the lensing results from the Dark Energy Survey, and give combined lensing-only parameter constraints that are tighter than joint results using galaxy clustering. Using the Planck cosmic infrared background (CIB) maps as an additional tracer of high-redshift matter, we make a combined Planck-only estimate of the lensing potential over 60% of the sky with considerably more small-scale signal. We additionally demonstrate delensing of the Planck power spectra using the joint and individual lensing potential estimates, detecting a maximum removal of 40% of the lensing-induced power in all spectra. The improvement in the sharpening of the acoustic peaks by including both CIB and the quadratic lensing reconstruction is detected at high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

First Spectropolarimetric Measurement of a Brown Dwarf Magnetic Field in Molecular Bands

We present the first measurements of the surface magnetic field of a late-M dwarf, LSR J1835+3259, with the help of the full-Stokes spectropolarimetry in the bands of diatomic molecules. Our measurements at different rotational phases of a dwarf yielded one 5 σ and two 3 σ magnetic field detections. The observational data have been obtained with the LRISp polarimeter at the Keck observatory on 2012 August 22 and 23. These data have been compared against synthetic full-Stokes spectra in the bands of the molecules CrH, FeH, and TiO, which have been calculated for a range of the stellar parameters and magnetic field strengths. Making use of χ {sup 2}-minimization and maximum likelihood estimation, we determine the net magnetic field strength B (and not flux Bf ) of LSR J1835+3259 to ∼5 kG with the help of the Paschen–Back effect in the CrH lines. Our measurements at different rotational phases suggest that the dwarf’s surface might be covered with strong small-scale magnetic fields. In addition, recent findings of the dwarf’s hydrogen emission and the Stokes V signal from the lower chromosphere indicate that its surface magnetic field might be changing rapidly giving rise to flare activity, similar to young dMe dwarfs. We substantiate the substellar origin of LSR J1835+3259 by making use of our own data as well as the photometric data from the all-sky surveys 2MASS and WISE .

79 ASTRONOMY AND ASTROPHYSICS↗

Orbits for 18 Visual Binaries and Two Double-line Spectroscopic Binaries Observed with HRCAM on the CTIO SOAR 4 m Telescope, Using a New Bayesian Orbit Code Based on Markov Chain Monte Carlo

We present orbital elements and mass sums for 18 visual binary stars of spectral types B to K (five of which are new orbits) with periods ranging from 20 to more than 500 yr. For two double-line spectroscopic binaries with no previous orbits, the individual component masses, using combined astrometric and radial velocity data, have a formal uncertainty of ∼0.1 M{sub ⊙}. Adopting published photometry and trigonometric parallaxes, plus our own measurements, we place these objects on an H-R diagram and discuss their evolutionary status. These objects are part of a survey to characterize the binary population of stars in the Southern Hemisphere using the SOAR 4 m telescope+HRCAM at CTIO. Orbital elements are computed using a newly developed Markov chain Monte Carlo (MCMC) algorithm that delivers maximum-likelihood estimates of the parameters, as well as posterior probability density functions that allow us to evaluate the uncertainty of our derived parameters in a robust way. For spectroscopic binaries, using our approach, it is possible to derive a self-consistent parallax for the system from the combined astrometric and radial velocity data (“orbital parallax”), which compares well with the trigonometric parallaxes. We also present a mathematical formalism that allows a dimensionality reduction of the feature space from seven to three search parameters (or from 10 to seven dimensions—including parallax—in the case of spectroscopic binaries with astrometric data), which makes it possible to explore a smaller number of parameters in each case, improving the computational efficiency of our MCMC code.

79 ASTRONOMY AND ASTROPHYSICS↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A survey of luminous high-redshift quasars with SDSS and Wise. II. The bright end of the quasar luminosity function at z ∼ 5

This is the second paper in a series on a new luminous z ∼ 5 quasar survey using optical and near-infrared colors. Here we present a new determination of the bright end of the quasar luminosity function (QLF) at z ∼ 5. Combining our 45 new quasars with previously known quasars that satisfy our selections, we construct the largest uniform luminous z ∼ 5 quasar sample to date, with 99 quasars in the range of 4.7 ≤ z < 5.4 and −29 < M {sub 1450} ≤ −26.8, within the Sloan Digital Sky Survey (SDSS) footprint. We use a modified 1/V {sub a} method including flux limit correction to derive a binned QLF, and we model the parametric QLF using maximum likelihood estimation. With the faint-end slope of the QLF fixed as α = −2.03 from previous deeper samples, the best fit of our QLF gives a flatter bright end slope β = −3.58 ± 0.24 and a fainter break magnitude M{sub 1450}{sup ∗} = −26.98 ± 0.23 than previous studies at similar redshift. Combined with previous work at lower and higher redshifts, our result is consistent with a luminosity evolution and density evolution model. Using the best-fit QLF, the contribution of quasars to the ionizing background at z ∼ 5 is found to be 18%–45% with a clumping factor C of 2–5. Our sample suggests an evolution of radio loud fraction with optical luminosity but no obvious evolution with redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

The spatial structure of young stellar clusters. I. Subclusters

The clusters of young stars in massive star-forming regions show a wide range of sizes, morphologies, and numbers of stars. Their highly subclustered structures are revealed by the MYStIX project's sample of 31,754 young stars in nearby sites of star formation (regions at distances <3.6 kpc that contain at least one O-type star.) In 17 of the regions surveyed by MYStIX, we identify subclusters of young stars using finite mixture models—collections of isothermal ellipsoids that model individual subclusters. Maximum likelihood estimation is used to estimate the model parameters, and the Akaike Information Criterion is used to determine the number of subclusters. This procedure often successfully finds famous subclusters, such as the BN/KL complex behind the Orion Nebula Cluster and the KW-object complex in M 17. A catalog of 142 subclusters is presented, with 1-20 subclusters per region. The subcluster core radius distribution for this sample is peaked at 0.17 pc with a standard deviation of 0.43 dex, and subcluster core radius is negatively correlated with gas/dust absorption of the stars—a possible age effect. Based on the morphological arrangements of subclusters, we identify four classes of spatial structure: long chains of subclusters, clumpy structures, isolated clusters with a core-halo structure, and isolated clusters well fit by a single isothermal ellipsoid.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic generation of hourly rainstorm events in Johor

Engineers and researchers in water-related studies are often faced with the problem of having insufficient and long rainfall record. Practical and effective methods must be developed to generate unavailable data from limited available data. Therefore, this paper presents a Monte-Carlo based stochastic hourly rainfall generation model to complement the unavailable data. The Monte Carlo simulation used in this study is based on the best fit of storm characteristics. Hence, by using the Maximum Likelihood Estimation (MLE) and Anderson Darling goodness-of-fit test, lognormal appeared to be the best rainfall distribution. Therefore, the Monte Carlo simulation based on lognormal distribution was used in the study. The proposed model was verified by comparing the statistical moments of rainstorm characteristics from the combination of the observed rainstorm events under 10 years and simulated rainstorm events under 30 years of rainfall records with those under the entire 40 years of observed rainfall data based on the hourly rainfall data at the station J1 in Johor over the period of 1972–2011. The absolute percentage error of the duration-depth, duration-inter-event time and depth-inter-event time will be used as the accuracy test. The results showed the first four product-moments of the observed rainstorm characteristics were close with the simulated rainstorm characteristics. The proposed model can be used as a basis to derive rainfall intensity-duration frequency in Johor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Orbits and Masses of Binaries from Speckle Interferometry at SOAR

We present results from Speckle inteferometric observations of 15 visual binaries and one double-line spectroscopic binary, carried out with the HRCam Speckle camera of the SOAR 4.1 m telescope. These systems were observed as a part of an on-going survey to characterize the binary population in the solar vicinity, out to a distance of 250 pc. We obtained orbital elements and mass sums for our sample of visual binaries. The orbits were computed using a Markov Chain Monte Carlo algorithm that delivers maximum likelihood estimates of the parameters, as well as posterior probability density functions that allow us to evaluate their uncertainty. Their periods cover a range from 5 yr to more than 500 yr; and their spectral types go from early A to mid M, implying total system masses from slightly more than 4M{sub ⊙} down to 0.2M {sub ⊙}. They are located at distances between approximately 12 and 200 pc, mostly at low Galactic latitude. For the double-line spectroscopic binary YSC8, we present the first combined astrometric/radial-velocity orbit resulting from a self-consistent fit, leading to individual component masses of 0.897 ± 0.027 M {sub ⊙} and 0.857 ± 0.026 M {sub ⊙}; and an orbital parallax of 26.61 ± 0.29 mas, which compares very well with the Gaia DR2 trigonometric parallax (26.55 ± 0.27 mas). In combination with published photometry and trigonometric parallaxes, we place our objects on an H-R diagram and discuss their evolutionary status. We also present a thorough analysis of the precision and consistency of the photometry available for them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the largest angular scale CMB B-mode polarization with galactic foregrounds on a cut sky

We consider the effectiveness of foreground cleaning in the recovery of Cosmic Microwave Background (CMB) polarization sourced by gravitational waves for tensor-to-scalar ratios in the range 0<r<0.1. Using the planned survey area, frequency bands, and sensitivity of the Cosmology Large Angular Scale Surveyor (CLASS), we simulate maps of Stokes Q and U parameters at 40, 90, 150, and 220 GHz, including realistic models of the CMB, diffuse Galactic thermal dust and synchrotron foregrounds, and Gaussian white noise. We use linear combinations (LCs) of the simulated multifrequency data to obtain maximum likelihood estimates of r, the relative scalar amplitude s, and LC coefficients. We find that for 10,000 simulations of a CLASS-like experiment using only measurements of the reionization peak (ℓ⩽23), there is a 95% C.L. upper limit of r<0.017 in the case of no primordial gravitational waves. For simulations with r=0.01, we recover at 68% C.L. r=0.012{sub −0.006}{sup +0.011}. The reionization peak corresponds to a fraction of the multipole moments probed by CLASS, and simulations including 30⩽ℓ⩽100 further improve our upper limits to r<0.008 at 95% C.L. (r=0.010{sub −0.004}{sup +0.004} for primordial gravitational waves with r = 0.01). In addition to decreasing the current upper bound on r by an order of magnitude, these foreground-cleaned low multipole data will achieve a cosmic variance limited measurement of the E-mode polarization’s reionization peak.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-F-CAMPUS-J-05: Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy

Purpose: The purpose of this study is to verify the acquisition of the three dimensional single photon emission computed tomography (SPECT) image using prompt gamma ray originated from proton boron fusion therapy (PBFT). Methods: The real-time imaging system during the PBFT was simulated to acquire the tomographic image of the prompt gamma ray from treated tumor by the proton boron reaction, using Monte Carlo simulation (MCNPX). We acquired percentage depth dose (PDD) of the proton beam in the water phantom including the boron uptake region (BUR), the energy spectra of the prompt gamma ray and tomographic image which can show treated tumor regions. The prompt gamma ray image was reconstructed using maximum likelihood estimation maximization (MLEM) reconstruction algorithm with 64 projections. In addition, in order to evaluate the reconstructed image, the image profiles between BURs were extracted from the image. Results: In the PDD results, the Bragg-peak was amplified definitely when the proton’s maximum dose level was located at the BUR. This amplification is based on the generation of alpha particles. In addition, the prompt gamma ray peak of 719 keV was observed from the energy spectrum. Through the previous process, the tomographic image of prompt gamma ray from the BUR was reconstructed. The line profile was extracted from image including BURs, and it shows high signal-to-noise ratio. Conclusion: We confirmed that the real-time prompt gamma ray image during the PBFT was successfully deducted, and results of quantitative image analysis show good agreement with the original pattern of the BUR. This study first verified the imaging capability of the PBFT-SPECT system. In conclusion, the PBFT-SPECT system can realize the treated tumor monitoring during the PBFT.

60 APPLIED LIFE SCIENCES↗

Systematic analysis on spectral statistics of odd-A nuclei

Level statistics for given spin and parity below 10 MeV within A≤71, 71≤A≤151, and 151≤A≤221 mass regions are systematically analyzed. We have taken 5316 level spacings from 266 odd-A nuclei in the light mass region, 6897 level spacings from 478 ones in the medium mass region, and 2768 level spacings from 143 ones in the heavy mass region for the statistics. In the analysis, the chaoticity parameter in the Berry–Robnik distribution is determined based on the method of maximum likelihood estimation. The results show a mass number A-dependence in the level statistics. The larger the mass number, the relatively stronger in chaoticity. In addition, with the level statistics in using data sequences classified according to the order of magnitude of half-lives, it is shown that the level energies to be more chaotic for longer lived light and heavy mass odd-A nuclei, and intermediate between regular and chaotic in medium mass odd-A nuclei. The level statistical analysis in concerning E2 transition strengths of E2 or mixed E2+M1 transitions in odd-A nuclei is also made, which shows chaos in level energies likely occurring in those with weaker E2 transition strengths. Therefore, it can be concluded that odd-A nuclei are, more often than not, chaotic. Chaos is likely emergent in level energies of stable light mass nuclei with weaker E2 transition strengths, while it is definitely emergent in level energies of heavy mass nuclei, and even stronger in comparatively stable ones and those with weaker E2 transition strengths.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-stage model of radon-induced malignant lung tumors in rats: effects of cell killing

A two-stage stochastic model of carcinogenesis is used to analyze lung tumor incidence in 3750 rats exposed to varying regimens of radon carried on a constant-concentration uranium ore dust aerosol. New to this analysis is the parameterization of the model such that cell killing by the alpha particles could be included. The model contains parameters characterizing the rate of the first mutation, the net proliferation rate of initiated cells, the ratio of the rates of cell loss (cell killing plus differentiation) and cell division, and the lag time between the appearance of the first malignant cell and the tumor. Data analysis was by standard maximum likelihood estimation techniques. Results indicate that the rate of the first mutation is dependent on radon and consistent with in vitro rates measured experimentally, and that the rate of the second mutation is not dependent on radon. An initial sharp rise in the net proliferation rate of initiated cell was found with increasing exposure rate (denoted model I), which leads to an unrealistically high cell-killing coefficient. A second model (model II) was studied, in which the initial rise was attributed to promotion via a step function, implying that it is due not to radon but to the uranium ore dust. This model resulted in values for the cell-killing coefficient consistent with those found for in vitro cells. An "inverse dose-rate" effect is seen, i.e. an increase in the lifetime probability of tumor with a decrease in exposure rate. This is attributed in large part to promotion of intermediate lesions. Since model II is preferable on biological grounds (it yields a plausible cell-killing coefficient), such as uranium ore dust. This analysis presents evidence that a two-stage model describes the data adequately and generates hypotheses regarding the mechanism of radon-induced carcinogenesis.

NASA Program Radiation Health↗

UVUDF: UV Luminosity Functions at the Cosmic High Noon

We present the rest-1500 Å UV luminosity functions (LF) for star-forming galaxies during the cosmic high noon—the peak of cosmic star formation rate at 1.5<z<3. We use deep NUV imaging data obtained as part of the Hubble Ultra-Violet Ultra Deep Field (UVUDF) program, along with existing deep optical and NIR coverage on the HUDF. We select F225W, F275W, and F336W dropout samples using the Lyman break technique, along with samples in the corresponding redshift ranges selected using photometric redshifts, and measure the rest-frame UV LF at z∼1.7,2.2,3.0, respectively, using the modified maximum likelihood estimator. We perform simulations to quantify the survey and sample incompleteness for the UVUDF samples to correct the effective volume calculations for the LF. We select galaxies down to M{sub UV}=−15.9,−16.3,−16.8 and fit a faint-end slope of α=−1.20{sub −0.13}{sup +0.10},−1.32{sub −0.14}{sup +0.10},−1.39{sub −0.12}{sup +0.08} at 1.4<z<1.9, 1.8<z<2.6, and 2.4<z<3.6, respectively. We compare the star formation properties of z∼2 galaxies from these UV observations with results from Hα and UV+IR observations. We find a lack of high-SFR sources in the UV LF compared to the Hα and UV+IR, likely due to dusty SFGs not being properly accounted for by the generic IRX--β relation used to correct for dust. We compute a volume-averaged UV-to-Hα ratio by abundance matching the rest-frame UV LF and Hα LF. We find an increasing UV-to-Hα ratio toward low-mass galaxies (M{sub ⋆}≲5×10{sup 9} M{sub ⊙}). We conclude that this could be due to a larger contribution from starbursting galaxies compared to the high-mass end.

79 ASTRONOMY AND ASTROPHYSICS↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Learning generative neural networks with physics knowledge

Deep generative neural networks have enabled modeling complex distributions, but incorporating physics knowledge into the neural networks is still challenging and is at the core of current physics-based machine learning research. To this end, we propose a physics generative neural network (PhysGNN), a new class of generative neural networks for learning unknown distributions in a physical system described by partial differential equations (PDE). PhysGNN couples PDE systems with generative neural networks. It is a fully differentiable model that allows back-propagation of gradients through both numerical PDE solvers and generative neural networks, and is trained by minimizing the discrete Wasserstein distance between generated and observed probability distributions of the PDE outputs using the stochastic gradient descent method. Moreover, PhysGNN does not require adversarial training like standard generative neural networks, which offers better stability than adversarial training. We show that PhysGNN can learn complex distributions in stochastic inverse problems, where conventional methods such as maximum likelihood estimation and momentum matching methods may be inapplicable when little knowledge is known about the form of unknown distributions or the physical model is too complex. Furthermore, our method allows physics-based generative neural network training for learning complex distributions in the context of differential equations.

97 MATHEMATICS AND COMPUTING↗

Latent map Gaussian processes for mixed variable metamodeling

Gaussian processes (GPs) are ubiquitously used in sciences and engineering as metamodels. Standard GPs, however, can only handle numerical or quantitative variables. Here we introduce latent map Gaussian processes (LMGPs) that inherit the attractive properties of GPs and are also applicable to mixed data which have both quantitative and qualitative inputs. The core idea behind LMGPs is to learn a continuous, low-dimensional latent space or manifold which encodes all qualitative inputs. To learn this manifold, we first assign a unique prior vector representation to each combination of qualitative inputs. We then use a low-rank linear map to project these priors on a manifold that characterizes the posterior representations. As the posteriors are quantitative, they can be directly used in any standard correlation function such as the Gaussian or Matern. Hence, the optimal map and the corresponding manifold, along with other hyperparameters of the correlation function, can be systematically learned via maximum likelihood estimation. Through a wide range of analytic and real-world examples, we demonstrate the advantages of LMGPs over state-of-the-art methods in terms of accuracy and versatility. In particular, we show that LMGPs can handle variable-length inputs, have an explainable neural network interpretation, and provide insights into how qualitative inputs affect the response or interact with each other. We also employ LMGPs in Bayesian optimization and illustrate that they can discover optimal compound compositions more efficiently than conventional methods that convert compositions to qualitative variables via manual featurization.

42 ENGINEERING↗

Toward the application of the Risk-Based Maintenance approach to a hydrogen-fueled manufacturing plant

Safety, reliability, and maintenance of hydrogen-based equipment, including Risk-Based Maintenance (RBM), have recently gained increasing attention, as hydrogen, while key to decarbonizing hard-to-abate sectors, raises safety concerns. However, two literature gaps limit the development of risk-based strategies for hydrogen technologies. First, existing RBM methodologies do not account for hydrogen-specific components, such as electrolyzers, which differ from conventional equipment. Second, available studies on electrolyzer reliability remain largely qualitative or laboratory-scale. This study addresses these gaps by proposing an adapted RBM methodology tailored to hydrogen-fueled manufacturing facilities. Integrating qualitative tools (e.g., FMEA) with probabilistic models (e.g., Bayesian Networks) enables comprehensive hazardous scenarios identification and likelihood estimation. A conceptual layout of a glass furnace supplied by a 3 MW PEM electrolyzer is considered as a case study to demonstrate the feasibility of the adapted RBM framework in identifying high-risk components and enabling maintenance prioritization, potentially improving plant safety.

08 HYDROGEN↗