Search NASA⌕ Search

SEARCH · Search NASA

Results for “load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A VSM-Based DER Dispatch MINLP for Volt-VAR Control in Unbalanced Power Distribution Systems

This paper presents an optimal dispatch algorithm to coordinate customer-owned controllable loads and smart solar inverters with utility-owned voltage regulators and capacitors to meet voltage control objectives. The optimization problem is formulated as a mixed-integer nonlinear programming (MINLP) problem. A voltage sensitivity matrix (VSM) is used to linearize the effect of control actions on the voltage at customer nodes when solving the MINLP. The VSM is recalculated at each time step to improve the computational accuracy. Both discrete switching actions of the capacitor and VRs and the continuous adjustment of real and reactive power from load and smart inverters are considered in the MINLP volt-var problem formulation. The objective function minimizes the cost of all control actions and the magnitude of voltage fluctuations from the previous time period. Constraints ensure that the voltage at each node is maintained within ANSI limits and the feeder power factor is controlled within the desired range. The algorithm is tested using an actual 3-phase unbalanced distribution feeder model. Simulation results demonstrate that the proposed algorithm is computationally feasible on real circuits and improves voltage control while minimizing operational costs.

McEntee, Catie↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project. ACT/Control/Guidance System study, volume 1

The active control technology (ACT) control/guidance system task of the integrated application of active controls (IAAC) technology project within the NASA energy efficient transport program was documented. The air traffic environment of navigation and air traffic control systems and procedures were extrapolated. An approach to listing flight functions which will be performed by systems and crew of an ACT configured airplane of the 1990s, and a determination of function criticalities to safety of flight, are the basis of candidate integrated ACT/Control/Guidance System architecture. The system mechanizes five active control functions: pitch augmented stability, angle of attack limiting, lateral/directional augmented stability, gust load alleviation, and maneuver load control. The scope and requirements of a program for simulating the integrated ACT avionics and flight deck system, with pilot in the loop, are defined, system and crew interface elements are simulated, and mechanization is recommended. Relationships between system design and crew roles and procedures are evaluated.

Source record↗

High temperature fatigue behavior of tungsten copper composites

The present study investigates the high-temperature fatigue behavior of a 9-v/o tungsten fiber-reinforced copper matrix composite. Load-controlled isothermal fatigue at 260 and 560 C and thermomechanical fatigue (TMF) experiments, both in-phase and out-of-phase between 260 and 560 C, were performed. The stress-strain response under all conditions displayed considerable inelasticity. Strain ratchetting was observed during all the fatigue experiments. For the isothermal fatigue and in-phase TMF tests, the ratchetting was always in a tensile direction, continuing until failure. The ratchetting during the out-of-phase TMF test shifted from a tensile to a compressive direction. For all cases, the fatigue lives were found to be controlled by the damage of the copper matrix. On a stress basis, TMF loading substantially reduced lives relative to isothermal cycling.

Verrilli, M. J.↗

Loads and Structural Dynamics Requirements for Spaceflight Hardware

The NASA Exploration Systems Development Mission Directorate requires Crewed Space Systems (CSS) to meet the intent of a set of Engineering Technical Authority (TA) documents called out in HEOMD-003, Crewed Deep Space Systems Human Rating Certification Requirements and Standards for NASA Missions. For the Loads and Dynamics technical discipline, the document invoked by the HEOMD-003 is JSC 65829, Loads and Structural Dynamics Requirements for Spaceflight Hardware. JSC 65829 was originally developed for the NASA Commercial Crew Program as an implementation of NASA STD-5002, Load Analyses of Spacecraft and Payloads, for that Program. Since that time, tailored alternatives to JSC 65829 have been produced for the Gateway, Human Landing System, and Extravehicular Activity and Human Surface Mobility Programs. Experience with those Programs has shown that the reduced set of less-prescriptive requirements in those tailored documents offers an advantage over the set of requirements in JSC 65829 Rev A and is a better fit for the paradigm of NASA procurement of commercially developed systems for crewed spaceflight. Revision B of JSC 65829 has been constructed to align with those tailored documents. The reduction in the number and specificity of requirements is balanced by a new requirement for hardware developers to create and provide a Loads Control Plan which describes how the approaches used to generate design-to loads and dynamic environments and substantiate dynamic model validity satisfy the requirements herein. The Plan will establish an agreement between the hardware developer and the TA for the loads and dynamics discipline and offer an opportunity for reengagement if the Plan changes during development.

Kenneth Schultz↗

Data-Driven Load Modeling and Forecasting of Residential Appliances

The expansion of residential demand side management programs and increased deployment of controllable loads require accurate appliance-level load modeling and forecasting. This paper proposes a conditional hidden semi-Markov model to describe the probabilistic nature of residential appliance demand. Model parameters are estimated directly from power consumption data using scalable statistical learning methods. We also propose an algorithm for short-term load forecasting as a key application for appliance-level load models. Case studies performed using granular sub-metered power measurements from various types of appliances demonstrate the effectiveness of the proposed load model for short-term prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Investigation of Nominally-Orthogonal Pneumatic Active Flow Control for High-Lift Systems

We explore the feasibility of using nominally-orthogonal jets as active aerodynamic load control for multi-element high-lift systems, and whether the nominally-orthogonal jets can offer a variety of performance improvements. These nominally-orthogonal jets inject momentum normal to the airfoil surface near the flap trailing edge, where they create a vortex that entrains flow from the opposing side and change the airfoil circulation. Lift-enhancement opportunities of trailing edge nominally-orthogonal jets have previously been studied by Malavard et al. and Blaylock et al. on single-element airfoils; however, their effect on drag was not thoroughly investigated. In this study, we investigate two- dimensional nominally-orthogonal jet effects on both lift and drag on a two-element airfoil, NLR7301. We utilize Chimera Grid Tools to generate structured curvilinear overset grids, and the Reynolds-averaged Navier-Stokes solver OVERFLOW-2 to solve for the flow field around the airfoil. We perform various computational sensitivity studies on the baseline airfoil without a jet to validate computational results against benchmark experimental data. Using a Chimera overset grid topology, we demonstrate a similar lift-enhancement effect between a nominally-orthogonal jet and a nominally-orthogonal physical tab employed at the same location on the studied airfoil. After we introduce the nominally-orthogonal jet concept, we investigate nominally-orthogonal jets with various momentum coefficient settings, C(sub µ) = 0.00 − 0.04 and present a lift-enhancement relationship ∆C(sub l) ≃ 3.59 (C(sub µ)) for this airfoil. We discuss that utilizing a nominally-orthogonal jet with C(sub µ) = 0.01 can shift the linear region of the lift curve by a ∆C(sub l) = 0.36 for the pressure side jet and by a ∆C(sub l) = −0.27 for the suction side jet. Employing a nominally-orthogonal jet is also shown effective in altering the drag. To study the impact, we carry out a drag decomposition study in the form of drag polars. We show for a given C(sub l) = 2.50, a nominally-orthogonal jet with C(sub µ) = 0.01 on the pressure and suction side of the airfoil results in 113 drag count decrements and 41 drag count increments, respectively, compared to the baseline airfoil with no jet. These results show that large and controllable changes in aerodynamic performance can be achieved by relatively small active flow control inputs using the nominally-orthogonal jets presented in this study.

Nominally-Orthogonal↗

Modeling and Control of Cascaded Bridgeless Multilevel Rectifier Under Unbalanced Load Conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality.The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to achieve unity power factor using fully controlled hbridge cells. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. A novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization and power factor correction under unbalanced load conditions. Simulation and experimental results validate the models and control method.

Cascaded Bridgeless Rectifier, Power factor analys↗

Characterizing Electric Grid System Benefits of MPC-Based Residential Load Shaping: Preprint

Routinely encouraging and discouraging residential electric load throughout the day will be increasingly critical in efficiently managing the smart grid to reliably deliver clean, low-cost electricity. Yet, manipulating the duty cycles of thermostatically controlled loads such as heating, air conditioning, and hot water heaters can have the effect of destabilizing or stabilizing the grid. This work explores the potential for price-responsive control of residential air conditioning to shape electric demand at the distribution feeder level to minimize electricity production costs. Physical models of the interplay between building thermal and electric loads are used to Simulate time-series temperature and load behavior. Instantaneous load-adding and load-shedding opportunities are quantified in more than 100,000 individual homes on 204 distribution feeders with results presented for 35 cities across the United States. In the context of distributed model predictive control, simulation of feeder-level response to a residential day-ahead 5-minute pricing vector to 2,146 homes highlights an aggregate impact of flexible loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

Supporting cost-effective watershed management strategies for Chesapeake Bay using a modeling and optimization framework

Extensive efforts to adaptively manage nutrient pollution rely on Chesapeake Bay Program’s (Phase 6) Watershed Model, called Chesapeake Assessment Scenario Tool (CAST), which helps decision-makers plan and track implementation of Best Management Practices (BMPs). We describe mathematical characteristics of CAST and develop a constrained nonlinear BMP-subset model, software, and visualization framework. This represents the first publicly available optimization framework for exploring least-cost strategies of pollutant load control for the United States’ largest estuary. The optimization identifies implementation options for a BMP subset modeled with load reduction effectiveness factors, and the web interface facilitates interactive exploration of >30,000 solutions organized by objective, nutrient control level, and for ~200 counties. We assess framework performance and demonstrate modeled cost improvements when comparing optimization-suggested proposals with proposals inspired by jurisdiction plans. Stakeholder feedback highlights the framework’s current utility for investigating cost-effective tradeoffs and its usefulness as a foundation for future analysis of restoration strategies.

54 ENVIRONMENTAL SCIENCES↗

Integrated Solutions for Optimized Performance (ISOP) Final Technical Report

The goal of this project was to demonstrate technical feasibility of an integrated approach for deep energy retrofits by packaging innovative technologies with smart communicating controls that represent the next generation of energy efficiency. The integrated solutions for optimized performance (ISOP) package integrates (i) advanced lighting and plug load controls; (ii) intelligent daylight harvesting through automated self-powered shades and window films; (iii) advanced HVAC controls sequences (ASHRAE Guideline (GDL) 36); and (iv) fault detection and diagnosis (FDD) and continuous commissioning (CCx) using advanced analytics. These technologies address energy use across multiple building end uses that represent more than 60% of the energy consumption in all commercial buildings. The project was structured to be implemented over three budget periods: Budget Period 1 scope included site selection, project design, site-specific customization of technology packages, procurement of technologies, initiation of installation of technologies, the development of a measurement and verification plan and collection of pre-retrofit data collection. The first year go/no-go decision was based on securing host sites representing 250,000 sq. ft. of occupied operational spaces, savings analysis, technology procurement and initiation of installation. Budget Period 2 planned to complete technology installations and initiate data collection of post-retrofit performance data. The second year go/no-go was to be the completion of technology installations and commissioning, metering and data collecting to support the requirements laid out in site specific M&V plans. Budget Period 3 planned to collect and analyze post-retrofit performance data and provide data and reporting to support energy efficiency rebate programs. After the team completed activities planned for Budget Period 1, the team reached a Go/No-Go Decision Point. At that point, TRC recommended that DOE discontinue the project without prejudice due to challenges with securing demonstration sites to meet the full 250,000 sf of occupied operational spaces and DOE concurred. In Budget Period 1, the TRC team developed criteria to recruit and evaluate potential demonstration host sites. TRC worked with Princeton University, the project demonstration partner, to identify buildings on their campus as potential candidates for the demonstration. Following the selection of demonstration sites, the TRC team customized energy technology packages according to the needs and characteristics of each site. TRC defined technology specifications, identified vendors, and conducted analysis to estimate energy and cost savings potential. The project team then developed schedules for technology procurement processes and scheduled for installation at all selected demonstration sites. The project team worked with Princeton University and DOE to develop an approach to verify energy savings achieved through measurement and verification (M&V) 2.0 methods. Princeton University initiated open bids to procure the necessary materials and installation contractors. Bid results came back higher than estimates due to a couple of factors – lack of familiarity of the bidders with the proposed technologies and lack of local trained installers to execute the installation of these new measures. Due to the higher bids, projects no longer met the internal cost-effectiveness criteria used by Princeton to proceed with procurement of the full suite of technologies as proposed in ISOP. Princeton had already procured parts of the ISOP package as part of a campus-wide initiative for FDD and lighting retrofits, but with the higher costs for other ISOP components, Princeton could no longer commit to the full ISOP package on the selected sites. Based on this, the team reached the Go/No-Go decision point, where they decided not to proceed with the project. Princeton is separately installing portions of the ISOP package where they individually meet Princeton’s payback criteria but on a different schedule than would have been needed for the DOE ISOP project. The team has learned several lessons from project progress in the first budget period. The team will utilize these lessons in future projects, as should any team which proceeds with a project around the ISOP technology. The first lesson is that more information about the proposed sites is required earlier in the process (perhaps even at the proposal stage) in order to have a successful demonstration. Technical details not evident earlier in the process (such as the TLED limitations for ALCS) can derail project execution. The second lesson is that pricing of emerging technologies is highly variable due to lack of familiarity of local installers and distributor with the proposed technologies as well as alternate bids using products they were more familiar with, but that cost more than the ones proposed by TRC. Finally, the last major lesson is that the host site’s internal project criteria is of critical importance. Based on these higher installed costs and lack of an informed installer base for the products proposed for this project, the project does not meet Princeton’s simple payback goals of five years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage-controlled attenuator with low phase shift

Five megahertz RF (radiofrequency) signal attenuator utilizing RF quadrature hybrid, and optically viable-resistance load controlled by lamp circuit exhibits little phase shift. Circuit is designed to help distribute standard RF signal of controlled amplitude, and phase throughout complex of facilities could be useful in application to precision test equipment and communication electronics.

Lutes, G. F., Jr.↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗