Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Aluminum Shear Panels for Seismic Protection of Framed Structures: Review of Recent Experimental Studies

An important experimental campaign on pure aluminum shear panels, to develop new devices for the seismic passive protection of buildings, has been recently carried out at the University of Naples 'Federico II' in cooperation with the University 'G. d'Annunzio' of Chieti/Pescara. In particular, several pure aluminum shear panels, suitably reinforced by ribs in order to delay shear buckling in the plastic deformation field, have been tested under cyclic loads. The choice pure aluminium, which is really innovative in the field of civil engineering, is justified by both the nominal low yield strength and the high ductility of such a material, which have been further improved through a proper heat treatment. Two different testing layouts have been adopted. In the former, six 'full bay' pure aluminum shear panels, having in-plane dimensions 1500x1000 mm and thickness of 5 mm, have been taken in consideration. In the latter, four 5 mm thick stiffened bracing type pure aluminum shear panels (BTPASPs) with a square shape of 500 mm side length have been cyclically tested under diagonal load. In the whole several plate slenderness ratios have been considered, allowing the evaluation of the most influential factors on the cyclic performance of system. In the current paper a review of the most important results of these recent experimental activities is provided and discussed.

58 GEOSCIENCES↗

On-Track Measurement of Road Load Changes in Two Close-Following Vehicles: Methods and Results

As emerging automated vehicle technology is making advances in safety and reliability, engineers are also exploring improvements in energy efficiency with this new paradigm. Powertrain efficiency receives due attention, but also impactful is finding ways to reduce driving losses in coordinated-driving scenarios. Efforts focused on simulation to quantify road load improvements require a sufficient amount of background validation work to support them. This study uses a practical approach to directly quantify road load changes by testing the coordinated driving of two vehicles on a test track at various speeds (64, 88, 113 km/h) and vehicle time gaps (0.3 to 1.3 s). Axle torque sensors were used to directly measure the load required to maintain steady-state speeds while following a lead vehicle at various gap distances. Through trial and error, test methods were developed that appear to provide satisfactory results, considering the challenges of track testing under real-world conditions (wind, weather, temperature changes, etc.). We found that total road load was reduced by about 10-12% at an optimum gap time of 0.25 to 0.4 s. Challenges that were encountered included less repeatability of load measurements at short gap distances and powertrain mode switching (from a hybrid vehicle) that rendered the 88-km/h results less useful. This study will provide the framework for further investigations on coordinated-driving road load using track testing methods.

Duoba, Michael↗

Comparing State-Space Multivariable Controls to Multi-SISO Controls for Load Reduction of Drivetrain-Coupled Modes on Wind Turbines Through Field-Testing

In this paper we present results from an ongoing controller comparison study at the National Renewable Energy Laboratory's (NREL's) National Wind Technology Center (NWTC). The intention of the study is to demonstrate the advantage of using modern multivariable methods for designing control systems for wind turbines versus conventional approaches. We will demonstrate the advantages through field-test results from experimental turbines located at the NWTC. At least two controllers are being developed side-by-side to meet an incrementally increasing number of turbine load-reduction objectives. The first, a multiple single-input, single-output (m-SISO) approach, uses separately developed decoupled and classicially tuned controllers, which is, to the best of our knowledge, common practice in the wind industry. The remaining controllers are developed using state-space multiple-input and multiple-output (MIMO) techniques to explicity account for coupling between loops and to optimize given known frequency structures of the turbine and disturbance. In this first publication from the study, we present the structure of the ongoing controller comparison experiment, the design process for the two controllers compared in this phase, and initial comparison results obtained in field-testing.

17 WIND ENERGY↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Verification Problems for Parameterized Load Curves in DYNA3D

Two verification problems are presented which test a set of newly implemented load curve features in the explicit finite element program DYNA3D. Each test consists of a single element, with the velocity of each node specified via a different load curve type. The first test covers initialization and run-time execution of these new features, while the second test covers redefinition of load curves upon restart. The proposed problems may be easily extended to test additional load curve features.

42 ENGINEERING↗

Execution of Targeted Experiments to Inform BISON for ATF Materials: An Advanced Approach to Tube Burst Testing

This report describes a new, advanced experimental approach for testing tube specimens loaded by internal pressure. The approach allows conventional tube burst testing to be performed and employs digital image recording and analysis for conducting noncontact optic strain measurements. Section 1 provides a brief introduction and motivation for the project. Section 2 describes the selected approach and provides technical details regarding the modified experimental tube burst system: a commercial infrared furnace redesigned to support this work by adding two 50-mm- diameter optic ports to make the specimen visible during the burst tests, and a digital camera used to record specimen images, lens, and optic filters. Section 3 briefly analyzes a typical burst test and the digital image correlation dataset, recorded during the experiment, and discusses the experiment outcome including local strains along the tube specimen. Additionally, section 3 focuses on the issues influencing the in situ strain measurement accuracy and final results and suggests changes in the experimental scheme to improve data quality and reliability. The conclusion summarizes the work performed to date and discusses possible future activity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical testing of hydrided fuel cladding

During light water reactor operations, hydrogen is generated from the oxidation of zirconium alloy materials. This hydrogen can be absorbed into the cladding and form zirconium hydrides. At high temperatures and hoop stresses, these normally circumferential oriented hydrides in high burnup used nuclear fuel (HB-UNF) may reorient in the radial direction and affect the mechanical properties of the cladding. Understanding these changes in mechanical properties will aid in analyzing how UNF will perform during storage and transportation. Systems, presented in the article, have been designed to introduce hydrides into cladding specimens, to reorient cladding hydrides, and to test and measure the mechanical properties of these specimens. The hydriding systems consist of a tube furnace capable of pre-hydriding cladding specimens and reorienting cladding hydrides and surface conditioning equipment. Mechanical testing (i.e., tensile, compression, and burst testing) will be performed on both pre-hydrided cladding and cladding with reoriented hydrides, and the results will be compared with those of as-manufactured cladding. Tensile and compression testing will be performed using a 5 kilo-pound load frame; burst testing will be performed on a purpose-built test system. Strain is measured with a digital image correlation (DIC) system. DIC is a real time optical measurement technique that utilizes high-definition imagery to measure object deformation. It is planned that tensile, compression, and burst testing of cladding with reoriented hydrides will begin this year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interaction of Water with Carbon Fiber Reinforced Polymer Laminates under Dynamic Loading Conditions

With the aim of simulating the real conditions during the navigation, in this framework, impact tests were performed by loading CFRP laminates immersed in the water from the front side. The specimens, made by vinyl ester matrix because of the lower moisture absorption compared to the other epoxy systems, are in the presence of the water to accurately simulate the incidental impact on the hull of the vessel, immersed or partially immersed, during the navigation. It can be caused by the ice in the Arctic Ocean, by a projectile due to a terroristic attack or by debris from an explosion. The results are compared with the ones obtained by loading the laminates in pure traditional impact tests in the air. The influence of the clamping device has been tested too. The exciting results obtained on carbon fiber laminates in the air (pure traditional impact tests), water-backed (with water on the back side) and waterfront (water only on the front side) conditions at room temperature are here reported and compared. They highlighted the critical role played by the complex fluid–structure interaction.

36 MATERIALS SCIENCE↗

High Power Testing of A Fused Quartz-based Dielectric-Loaded Accelerating Structure

We report on the most recent results from a series of high power tests being carried out on rf-driven dielectric loaded accelerating (DLA) structures. The purpose of these tests is to determine the viability of the DLA as a traveling-wave accelerator and is a collaborative effort between Argonne National Laboratory (ANL), Naval Research Laboratory (NRL), and Stanford Linear Accelerator Center (SLAC). In this paper, we report on the recent high power tests of a fused quartz-based DLA structure that was carried out at incident powers of up to 12 MW at NRL and 37 MW at SLAC. We also report on test results of a TiN coated quartz structure, that exhibits good multipactor suppression.

36 MATERIALS SCIENCE↗

SU-F-J-37: Commissioning a Six Degree of Freedom Couch

Purpose: The proper operation of a six degree of freedom couch (6DOFC) to position a patient for treatment requires that a number systems on the treatment unit work together correctly. Commissioning a 6DOFC requires not only the commissioning of each separate system but also commissioning the interactions between the systems. Methods: To commission a 6DOFC, we tested the resolvers that readout the linear and angular positions; the orthogonality of the axes of the laser positioning system, the imaging system, the gantry and the couch as well as their relationship to each other. An automated Winston-Lutz test was used verify the coincidence of the origins of the laser system, imaging system and treatment unit. The IsoCal phantom was used to verify the consistency of axes orientations between systems. The operation of the couch and imaging system was verified under simulated load conditions and an end to end test was performed to verify correct operation of the system. Results: The tests on the couch resolvers, orthogonality and coincidence of the axes of each system were successfully completed and showed excellent agreement. The automated Winston-Lutz test showed that the maximum displacement of the center of the radiation field with respect to the isocenter was <0.6 mm (radius) at isocenter. The analysis of the IsoCal phantom showed that the maximum variation of the radiation field with respect to known locations in the phantom was ∼0.9 mm for all the BBs in the phantom. Load tests showed maximum errors of 1 mm. Conclusion: We tested all system associated with the 6DOFC and found the uncertainty due to imaging was <.9mm and the uncertainty due to loading ∼1 mm, resulting in a total error of ∼1.4 mm.

60 APPLIED LIFE SCIENCES↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data. Additional capability is included with Ring Pull Coating Analysis (RPCA, also part of the software). Additional images are taken of samples with an outer coating and are used to correlate failure of the coating with strain values measured with DIC.

Beck, Peter↗

EFFECT OF RADIUS OF LOADING NOSE AND SUPPORTS IN SHORT BEAM TEST FIXTURE ON FRACTURE MODE AND INTERLAMINAR SHEAR STRENGTH OF GFRP AT 77 K

A short beam test is useful to evaluate interlaminar shear strength of glass fiber reinforced plastics, especially for material selection. However, effect of test fixture configuration on interlaminar shear strength has not been clarified. This paper describes dependence of fracture mode and interlaminar shear strength on the fixture radius using the same materials and procedure. In addition, global understanding of the role of the fixture is discussed. When small loading nose and supports are used for the tests, bending fracture or translaminar fracture happens and the interlaminar shear strength would become smaller. By adopting the large radius loading nose and supports (6 mm radius is recommended), it is newly recognized that some stress concentration is able to be reduced, and the interlaminar fracture tends to occur and the other fracture modes will be suppressed. The interlaminar shear strength of 2.5 mm thick GFRP plate of G-10CR is evaluated as 130-150 MPa at 77 K.

36 MATERIALS SCIENCE↗

High power testing of a fused quartz-based dielectric-loaded accelerating structure.

We report on the most recent results from a series of high power tests being carried out on rf-driven dielectric-loaded accelerating (DLA) structures. The purpose of these tests is to determine the viability of the DLA as a traveling-wave accelerator and is a collaborative effort between Argonne National Laboratory (ANL), Naval Research Laboratory (NRL), and Stanford Linear Accelerator Center (SLAC). In this paper, we report on the recent high power tests of a fused quartz-based DLA structure that was carried out at incident powers of up to 12 MW at NRL and 37 MW at SLAC. We also report on test results of a TiN coated quartz structure, that exhibits good multipactor suppression.

43 PARTICLE ACCELERATORS↗

Precursor Evolution and Stress Corrosion Cracking Initiation of Cold-Worked Alloy 690 in Simulated Pressurized Water Reactor Primary Water

Stress corrosion crack initiation of two thermally-treated, cold-worked (CW) alloy 690 (UNS N06690) materials was investigated in 360oC simulated PWR primary water using constant load tensile (CLT) tests and blunt notch compact tension (BNCT) tests equipped with direct current potential drop (DCPD) for in-situ detection of cracking. SCC initiation was not detected by DCPD for either the 21% or 31%CW CLT specimens loaded at their yield stress after ~9,220 hours, however intergranular (IG) precursor damage and isolated surface cracks were observed on the specimens. The two 31%CW BNCT specimens loaded at moderate stress intensity after several cyclic loading ramps showed DCPD-indicated crack initiation after 10,400 hours of exposure at constant stress intensity, which was resulted from significant growth of IG cracks. The 21%CW BNCT specimens only exhibited isolated small IG surface cracks and showed no apparent DCPD change throughout the test. Post-test cross-section examinations revealed many grain boundary (GB) nano-cavities in the bulk of all the CLT and BNCT specimens particularly for the 31%CW materials. Cavities were also found along GBs extending to the surface suggesting an important role in crack nucleation. This paper provides an overview of the evolution of GB cavities and discusses their effects on crack initiation in CW alloy 690.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗