CURRENT STATUS OF INSTRUMENTATION FOR A FLUORIDE SALT HEAT TRANSPORT DEMONSTRATION LOOP

A small forced convection liquid fluoride salt loop is under construction at Oak Ridge National Laboratory (ORNL) to examine the heat transfer behavior of FLiNaK in a heated pebble bed. Loop operation serves several purposes: (1) reestablishing the infrastructure necessary for fluoride salt loop testing, (2) demonstrating a wireless heating technique for simulating pebble type fuel, (3) demonstration of the integration of silicon carbide (SiC) and metallic components into a liquid salt loop, and (4) demonstration of the functionality of distinctive instrumentation required for liquid fluoride salts. Loop operation requires measurement of a broad set of process variables including temperature, flow, pressure, and level. Coolant chemistry measurements (as a corrosion indicator) and component health monitoring are also important for longer-term operation. Two dominating factors in sensor and instrument selection are the high operating temperature of the salt and its chemical environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orion Optical Navigation Progress Toward Exploration Mission 1

Optical navigation of human spacecraft was proposed on Gemini and implemented successfully on Apollo as a means of autonomously operating the vehicle in the event of lost communication with controllers on Earth. The Orion emergency return system utilizing optical navigation has matured in design over the last several years, and is currently undergoing the final implementation and test phase in preparation for Exploration Mission 1 (EM-1) in 2019. The software development is past its Critical Design Review, and is progressing through test and certification for human rating. The filter architecture uses a square-root-free UDU covariance factorization. Linear Covariance Analysis (LinCov) was used to analyze the measurement models and the measurement error models on a representative EM-1 trajectory. The Orion EM-1 flight camera was calibrated at the Johnson Space Center (JSC) electro-optics lab. To permanently stake the focal length of the camera a 500 mm focal length refractive collimator was used. Two Engineering Design Unit (EDU) cameras and an EDU star tracker were used for a live-sky test in Denver. In-space imagery with high-fidelity truth metadata is rare so these live-sky tests provide one of the closest real-world analogs to operational use. A hardware-in-the-loop test rig was developed in the Johnson Space Center Electro-Optics Lab to exercise the OpNav system prior to integrated testing on the Orion vehicle. The software is verified with synthetic images. Several hundred off-nominal images are also used to analyze robustness and fault detection in the software. These include effects such as stray light, excess radiation damage, and specular reflections, and are used to help verify the tuning parameters chosen for the algorithms such as earth atmosphere bias, minimum pixel intensity, and star detection thresholds.

Holt, Greg N.↗

Cadmium Depletion Impacts on Hardening Neutron6 Spectrum for Advanced Fuel Testing in ATR

For transmuting long-lived isotopes contained in spent nuclear fuel into shorter-lived fission products effectively is in a fast neutron spectrum reactor. In the absence of a fast spectrum test reactor in the United States of America (USA), initial irradiation testing of candidate fuels can be performed in a thermal test reactor that has been modified to produce a test region with a hardened neutron spectrum. A test region is achieved with a Cadmium (Cd) filter which can harden the neutron spectrum to a spectrum similar (although still somewhat softer) to that of the liquid metal fast breeder reactor (LMFBR). A fuel test loop with a Cd-filter has been installed within the East Flux Trap (EFT) of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). A detailed comparison analyses between the cadmium (Cd) filter hardened neutron spectrum in the ATR and the LMFBR fast neutron spectrum have been performed using MCWO. MCWO is a set of scripting tools that are used to couple the Monte Carlo transport code MCNP with the isotope depletion and buildup code ORIGEN-2.2. The MCWO-calculated results indicate that the Cd-filter can effectively flatten the Rim-Effect and reduce the linear heat rate (LHGR) to meet the advanced fuel testing project requirements at the beginning of irradiation (BOI). However, the filtering characteristics of Cd as a strong absorber quickly depletes over time, and the Cd-filter must be replaced for every two typical operating cycles within the EFT of the ATR. The designed Cd-filter can effectively depress the LHGR in experimental fuels and harden the neutron spectrum enough to adequately flatten the Rim Effect in the test region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydraulic Permeability of Resorcinol-Formaldehyde Ion-Exchange Resin - Effects of Oxygen Uptake and Radiation

An ion-exchange process, using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the U.S. Department of Energy's (DOE) Hanford site in Washington State. The RF resin is also being evaluated for use in the proposed Small Column Ion Exchange (SCIX) system, which is an alternative treatment option at DOE's Savannah River Site (SRS)in South Carolina. Testing at ORNL will determine the impact of radiation exposure and oxygen uptake by the RF resin on the hydraulic permeability of the resin. Samples of the resin will be removed periodically to measure physical properties (bead size and compressibility) and cesium capacity. The proposed full-scale treatment system at Hanford, the Waste Treatment Plant (WTP), will use an ion-exchange column containing nominally 680 gal of resin, which will treat 30 gpm of waste solution. The ion-exchange column is designed for a typical pressure drop of 6 psig, with a maximum of 9.7 psig. The lab-scale column is 3-in. clear PVC pipe and is prototypic of the proposed Hanford column. The fluid velocity in the lab-scale test will be much higher than for the full-scale column, in order to generate the maximum pressure drop expected in that column (9.7 psig). The frictional drag from this high velocity will produce similar forces on the resin in the lab-scale column as would be expected at the bottom of the full-scale column. The chemical changes in the resin caused by radiation exposure and oxygen uptake are expected to cause physical changes in the resin that could reduce the bed porosity and reduce the hydraulic permeability of the resin bed. These changes will be monitored by measuring the pressure drop through the lab-scale column and by measuring the physical properties of samples of the resin. The test loop with the lab-scale column is currently being fabricated, and operation will start by late May. Testing will be completed by the end of August.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Facility to Alleviate Salt Technology Risks (FASTR): Preliminary Design Report with Failure Modes and Effects Analysis

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) Concentrated Solar Power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of 725°C operation, flow rates of 3–7 kg/s, includes heated and cooled sections, and swappable components to enable testing of future vendor-supplied hardware. The salt preparation system supplies large batches (e.g., 200 kg) of clean salt for use in the FASTR forced convection loop. This report summarizes the planned design and capabilities of FASTR. In addition, a failure modes and effects analysis of the system is reported.

42 ENGINEERING↗

Flow Sensor Test Article (F-STAr) - Assembly and Water Testing Report

The Flow Sensor Test Article (F-STAr) is a new test article under development for the Mechanisms Engineering Test Loop (METL) facility at Argonne National Laboratory. F-STAr’s purpose is to provide sodium submersible, high flowrate testing capabilities for the development of sensors, components, fluid studies and more. This report will provide a status update on the assembly and initial qualification testing of F-STAr. All components have been manufactured and received. Some modifications to these components were made to support minor changes in the test article design. Additionally, the power distribution, and data acquisition and control enclosures were designed, completed, and tested along with the control system software. Furthermore, initial qualification testing was completed in water. Finally, the F-STAr submersible Electromagnetic Flowmeter (EMFM) was completed and calibrated in flowing sodium.

42 ENGINEERING↗

FOSWEC v2: System identification and control testing at Hinsdale Wave Research Laboratory

This report summarizes the design and execution of a wave tank test of the floating oscillating surge wave energy converter (FOSWEC) in the O.H. Hinsdale Wave Research Laboratory Directional Wave Basin at Oregon State University. This device, which uses two "flaps" that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The FOSWEC was originally considered to be a 1:33 scale device, however, for the current tests, no fixed relative scale is used (i.e., the WEC is considered to be scaled for the basin’s wave environment in which it operates). The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and experimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable. The data collected during testing is compressed into FOSWEC.zip. Please refer to Appendix C (pages 61-63) of the test report for descriptions of each test ID corresponding to the compressed files.

16 TIDAL AND WAVE POWER↗

An Integrated Energy Systems Prototype Human-System Interface for a Steam Extraction Loop System to Support Joint Electricity-Hydrogen Flexible Operations

Due to increasing economic competition from renewables and combined-cycle natural gas plants, nuclear power plants are looking toward flexible operations to enhance their cost competitiveness. The Integrated Energy Systems project under the Light Water Reactor Sustainability program of the U.S. Department of Energy focuses on joint electricity-hydrogen flexible operations. Joint electricity-hydrogen flexible operations entail the nuclear power plant diverting thermal energy via main steam to a hydrogen production plant located nearby. The steam serves to enhance the efficiency of the hydrogen production. Furthermore, high temperature electrolysis requires a large amount of electricity, which the plant can also provide. The plant provides steam and electricity to the hydrogen plant throughout the day, but during peak demand hours the nuclear power plant returns to solely providing electricity to meet the high demand. Through this flexible concept of operations, the plant can optimize the thermal energy it produces without having to maneuver the power of the plant. This report documents the human factors process to design and develop a prototype human-system interface for the steam extraction loop that serves as the conduit between the nuclear power plant and the adjacent hydrogen plant. The design process followed the human factors guidelines set by NUREG-0711, Human Factors Engineering Program Review Model (O’Hara, Higgins, & Fleger, 2012), and expanded upon by the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE; Boring, Ulrich, Joe, & Lew, 2015; Boring, Lew, & Ulrich, 2016). The design process entailed operator interviews to determine the concept of operations for the steam extraction loop, a review and adaptation of digital interface design concepts developed by the team in prior projects, an iterative design process, and reviews conducted by both operators and human factors experts. Several versions of the prototype human-system interface were developed. Operators were interviewed to determine what design features they found useful and would like to see in the interface. The design underwent a review by human factors experts against NUREG-0700, Human Interface Design Review Guidelines (U.S. Nuclear Regulatory Commission, 2019), to ensure compliance with the latest human factors standards for digital interfaces in nuclear applications. The design was then prototyped as a functional windows-based application integrated with the Generic Pressurized Water Reactor simulator modified to include the steam extraction loop. The simulation is supported by the Human Systems Simulation Laboratory at Idaho National Laboratory, which supports operator-in-the-loop testing. This is an ongoing project and the next phase of the project entails performing an operator-in-the-loop usability study to evaluate the interface and examine the proposed concept of operations to extraction steam from the nuclear power plant for delivery to the coupled hydrogen production plant.

99 GENERAL AND MISCELLANEOUS↗

Design, fabrication, and testing of a SMA hybrid composite jet engine chevron

Control of jet noise continues to be an important research topic. Exhaust nozzle chevrons have been shown to reduce jet noise, but parametric effects are not well understood. Additionally, thrust loss due to chevrons at cruise suggests significant benefit from deployable chevrons. The focus of this study is development of an active chevron concept for the primary purpose of parametric studies for jet noise reduction in the laboratory and technology development to leverage for full scale systems. The active chevron concept employed in this work consists of a laminated composite structure with embedded shape memory alloy (SMA) actuators, termed a SMA hybrid composite (SMAHC). The actuators are embedded on one side of the middle surface such that thermal excitation generates a moment and deflects the structure. A brief description of the chevron design is given followed by details of the fabrication approach. Results from bench top tests are presented and correlated with numerical predictions from a model for such structures that was recently implemented in MSC.Nastran and ABAQUS. Excellent performance and agreement with predictions is demonstrated. Results from tests in a representative flow environment are also presented. Excellent performance is again achieved for both open- and closed-loop tests, the latter demonstrating control to a specified immersion into the flow. The actuation authority and immersion performance is shown to be relatively insensitive to nozzle pressure ratio (NPR). Very repeatable immersion control with modest power requirements is demonstrated.

Turner, Travis L.↗

Toluene stability Space Station Rankine power system

A dynamic test loop is designed to evaluate the thermal stability of an organic Rankine cycle working fluid, toluene, for potential application to the Space Station power conversion unit. Samples of the noncondensible gases and the liquid toluene were taken periodically during the 3410 hour test at 750 F peak temperature. The results obtained from the toluene stability loop verify that toluene degradation will not lead to a loss of performance over the 30-year Space Station mission life requirement. The identity of the degradation products and the low rates of formation were as expected from toluene capsule test data.

Havens, V. N.↗

Test results on re-use of reclaimed shower water: Summary

A microgravity whole body shower (WBS) and waste water recovery systems (WWRS) were evaluated in three separate closed loop tests. Following a protocol similar to that anticipated for the U.S. Space Station, test subjects showered in a prototype whole body shower. The WWRS processes evaluated during the test series were phase change and reverse osmosis (RO). A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem phase change process was used for the initial test with chemical pretreatment of the shower water waste input. The second and third tests concentrated on RO technologies. The second test evaluated a dynamic RO membrane consisting of zirconium oxide polyacrylic acid (ZOPA) membranes deposited on the interior diameter of 316L porous stainless steel tubes while the final test employed a thin semipermeable RO membrane deposited on the interior surface of polysulfone hollow fibers. All reclaimed water was post-treated for purity using ion exchange and granular activated carbon beds immediately followed by microbial control treatment using both heat and iodine. The test hardware, controls exercised for whole body showering, types of soaps evaluated, shower subject response to reclaimed water showering, and shower water collection and chemical pretreatment (if required) for microbial control are described. The WWRS recovered water performance and the effectiveness of the reclaimed water post-treatment techniques used for maintaining water purity and microorganism control are compared. Results on chemical and microbial impurity content of the water samples obtained from various locations in the shower water reuse system are summarized.

Verostko, C. E.↗

Facility to Alleviate Salt Technology Risks (FASTR): Commissioning Update

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) concentrated solar power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of operating at 725°C with flow rates of 3–7 kg/s, and it includes heated and cooled sections and swappable components to facilitate testing future vendor-supplied hardware. The salt preparation system supplies large batches of clean salt for use in the FASTR forced circulation loop. This report summarizes the shakedown and initial operation of the FASTR forced circulation loop through December 2022.

14 SOLAR ENERGY↗

Applied Controls for sCO 2 Brayton Cycles

Sandia has a history of testing supercritical CO 2 Brayton Cycles to explore operation fundamentals and provide validation data for computer models. These systems have always had data acquisition and controls features. The Development Platform (DP) has been a flagship system for loop testing and operation but has been limited to manual control of many systems. Manual operation has increased operating complexity and reduced stability and repeatability. This work documents automated control development by linearizing otherwise non-linear valves, addition of closed-loop proportional-integral control software that has been tuned to the Sandia DP. It also describes testing of control methods that have improved test quality and reliability as shown in actual test data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facility to Alleviate Salt Technology Risks (FASTR): Design Report

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) Concentrated Solar Power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of 725°C operation and flow rates of 3–7 kg/s, and it includes heated and cooled sections and swappable components to enable testing of future vendor-supplied hardware. The salt preparation system supplies large batches (e.g., 200 kg) of clean salt for use in the FASTR forced convection loop. This report summarizes the design and capabilities of FASTR in its as-built form as of December 2022.

14 SOLAR ENERGY↗

Development of Flow Boiling and Condensation Experiment on the International Space Station- Normal and Low Gravity Flow Boiling Experiment Development and Test Results

Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and Critical Heat Flux (CHF) phenomena.

microgravity↗

Simulation of natural circulation cartridge loop experiments and application to molten salt reactors

This work uses the TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics (TH) code to model natural circulation cartridge loop experiments previously conducted at Oak Ridge National Laboratory (ORNL) using water and compares the simulated and experimental results. TRACE is also used to characterize natural circulation in the cartridge loop vehicle using FLiNaK as the working fluid. The experimental vehicle is a buoyancy-aided, annular cartridge loop, referred to as a thermosyphon, and is designed to aid in qualifying liquid–fueled and/or liquid–cooled irradiation experiments for the Versatile Test Reactor (VTR), which is currently being designed in the United States. Out-of-pile water experiments have been conducted using the cartridge and the Thermosyphon Test Loop facility at ORNL, and future experiments are anticipated that would use other molten salt surrogates as the working fluid, followed by eventual insertion of a similar cartridge into VTR. Additionally, this work aims to determine how well TRACE can replicate the natural convection conditions that were observed experimentally; this serves as an initial step for validating the modeling tool for design and safety calculations to support future irradiation experiments in VTR. Initial predictions of potential experiments were made using FLiNaK as the natural circulation fluid to demonstrate the relevance of the cartridge design to molten salt reactors (MSRs). Results from this study indicate that TRACE can accurately capture natural convection phenomena in the thermosyphon and that several design changes to the current cartridge vehicle are necessary to achieve hydraulic conditions similar to those expected in MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fuel Motion Monitoring System at TREAT – FY2017 Instrumentation Summary

This document is a report summarizing FY2017 efforts related to the Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System, "hodoscope," refurbishment campaign. TREAT is an air-cooled, graphite-moderated, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling situations in a nuclear reactor. Fuel meltdowns, metal-water reactions, thermal interaction between overheated fuel and coolant, and the transient behavior of ceramic fuel for high-temperature systems can be studied. A key instrument that monitors fuel motion as these events take place is the fast neutron hodoscope. The hodoscope is designed to allow for pre-, during-, and post- transient imaging of fuel within a test loop in the center of the reactor core. The preferred technique for imaging is detection of fast neutrons produced by fission in the test fuel, travelling unmoderated through an empty row of core fuel assemblies and then through a multi-slot collimator to a 360-detector array. Due to the age of the instrument, a refurbishment of the hodoscope’s fast neutron detection capability is necessary to support real-time, fuel-position experimental data collection. One particular challenge in this regard is related to the refurbishment of the fast-neutron-sensing detector elements in the detector array. This report summarizes major activities and accomplishments related to the FMMS refurbishment in FY2017. Of particular note was work related to identifying options for new proton recoil scintillator wafer and initial examination of the TREAT proton recoil proportional counter detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Spacelab IPS Star Simulator

The cost of doing business in space is very high. If errors occur while in orbit the costs grow and desired scientific data may be corrupted or even lost. The Spacelab Instrument Pointing System (IPS) Star Simulator is a unique test bed that allows star trackers to interface with simulated stars in a laboratory before going into orbit. This hardware-in-the-loop testing of equipment on earth increases the probability of success while in space. The IPS Star Simulator provides three fields of view 2.55 x 2.55 deg each for input into star trackers. The fields of view are produced on three separate monitors. Each monitor has 4096 x 4096 addressable points and can display 50 stars (pixels) maximum at a given time. The pixel refresh rate is 1000 Hz. The spectral output is approximately 550 nm. The available relative visual magnitude range is two to eight visual magnitudes. The star size is less than 100 arcsec. The minimum star movement is less than 5 arcsec and the relative position accuracy is approximately 40 arcsec. The purpose of this paper is to describe the IPS Star Simulator design and to provide an operational scenario so others may gain from the approach and possible use of the system.