Search NASA⌕ Search

SEARCH · Search NASA

Results for “map validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data

Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients with pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Entropy excess in strongly correlated Fermi systems near a quantum critical point

A system of interacting, identical fermions described by standard Landau Fermi-liquid (FL) theory can experience a rearrangement of its Fermi surface if the correlations grow sufficiently strong, as occurs at a quantum critical point where the effective mass diverges. As yet, this phenomenon defies full understanding, but salient aspects of the non-Fermi-liquid (NFL) behavior observed beyond the quantum critical point are still accessible within the general framework of the Landau quasiparticle picture. Self-consistent solutions of the coupled Landau equations for the quasiparticle momentum distribution n(p) and quasiparticle energy spectrum {epsilon}(p) are shown to exist in two distinct classes, depending on coupling strength and on whether the quasiparticle interaction is regular or singular at zero momentum transfer. One class of solutions maintains the idempotency condition n{sup 2}(p)=n(p) of standard FL theory at zero temperature T while adding pockets to the Fermi surface. The other solutions are characterized by a swelling of the Fermi surface and a flattening of the spectrum {epsilon}(p) over a range of momenta in which the quasiparticle occupancies lie between 0 and 1 even at T=0. The latter, non-idempotent solution is revealed by analysis of a Poincare mapping associated with the fundamental Landau equation connecting n(p) and {epsilon}(p) and validated by solution of a variational condition that yields the symmetry-preserving ground state. Significantly, this extraordinary solution carries the burden of a large temperature-dependent excess entropy down to very low temperatures, threatening violation of the Nernst Theorem. It is argued that certain low-temperature phase transitions, notably those involving Cooper-pair formation, offer effective mechanisms for shedding the entropy excess. Available measurements in heavy-fermion compounds provide concrete support for such a scenario. - Highlights: Black-Right-Pointing-Pointer Extension of Landau quasiparticle theory to strongly correlated Fermi systems. Black-Right-Pointing-Pointer Analysis of associated topological phase transitions at a quantum critical point. Black-Right-Pointing-Pointer Fermi surface rearrangement featuring hole pockets or emergence of flat bands. Black-Right-Pointing-Pointer Shedding of flat-band excess entropy via pairing transition at very low temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modulation of thermal conductivity of iron-doped ß-Ga2O3 by helium-ion irradiation

This study examines the impact of helium-ion irradiation on the thermal conductivity of ß-Ga2O3. A laser-based spatial domain thermoreflectance technique is used to investigate thermal conductivity map for both un-irradiated and irradiated ß-Ga2O3, which are then validated against simulation results derived from density functional theory-based phonon transport simulations. Since helium bubble evolution was ob- served at the nanoscale using transmission electron microscopy, the simulation study was carried out on eight distinct helium-induced sites in ß-Ga2O3. Our findings indicate a reduction in thermal conductivity for the irradiated samples. Experimental results show a significant reduction in thermal conductivity in irradiated samples, with de- creases of approximately 25% along the [100] direction and 40% along [001] directions. Phonon transport simulations closely replicate these findings, particularly when helium occupying interstitial sites, predicting reductions of ˜53% along [100] and ˜50% along [001] directions. This work underscores the role of irradiation-induced microstructural changes in the heat transport properties of ß-Ga2O3 which is crucial for its application in sensor devices in extreme environments.

36 - MATERIALS SCIENCE↗

Distributed temperature sensing inside a 19-rod bundle

The temperature field within a model of a sodium-cooled fast reactor fuel rod bundle was measured using Ø155 μm fiber optic distributed temperature sensors (DTS). The bundle consists of 19 electrically-heated rods Ø6.3 mm and 865 mm long. Working fluids were argon and air at atmospheric pressure and Reynolds numbers up to 300. A 20 m-long DTS was threaded through Ø1 mm capillaries wound around rods as wire-wraps. The sensor generated 173 measurements along each rod at 5 mm resolution for a total of 3300 data locations. A second DTS, 58 m long, was suspended between rods to provide 9300 fluid temperature measurements at 20 mm resolution. Such data density makes it possible to construct 3D maps of the temperature field that are beyond the reach of traditional sensors such as thermocouples. This is illustrated through a series of steady-state and transient tests. As a result, the work demonstrates the feasibility of mapping temperature within the close confines of a rod bundle at resolutions suitable for validation of computational fluid dynamics codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

LogPath: Log data based energy consumption analysis enabling electric vehicle path optimization

Vehicle navigation and path optimization require a more meticulous approach when it deals with EVs (electric vehicles) and SDVs (software-defined vehicles), due to lengthy charging times and the lack of charging infrastructure. Long-distance freight EV trucking needs path guidance with accurate energy consumption estimates to prevent charging-related failures. We developed a novel energy consumption estimation approach that only uses battery log data to extract major vehicle parameters to increase EV navigation accuracy without additional sensors. This is enabled by extracting multiple drive modes from the log data for analysis. The system provides 1) routes, 2) charge locations, 3) charging times, and 4) optimal vehicle speeds that guarantee the shortest travel time. Here we successfully validated the system using log data collected from an EV and Tesla's Supercharging map in the US and compared it with the commercially available navigation system, Tesla's trip planner, whose capabilities solely include charging time and routing.

EV (Electric vehicles) navigation↗

Gibbs Energy Minimization Model for Solvent Extraction with Application to Rare-Earths Recovery

The emergence of technologies in which rare-earth elements provide critical functionality has increased the demand for these materials, with important implications for supply security. Recycling provides an option for mitigating supply risk and for creating economic value from the resale of recovered materials. While solvent extraction is a proven technology for rare-earth recovery and separation, its application often requires extensive trial-and-error experimentation to estimate parameter values and determine experimental design configurations. We describe a modeling strategy based on Gibbs energy minimization that incorporates parameter estimation for required thermodynamic properties as well as process design for solvent extraction and illustrate its applicability to rare earths separation. Visualization analysis during parameter estimation revealed a linear relationship between the standard enthalpies of the extractant and respective organo-metal complexes, analogous to the additivity principle for predicting molar volumes of organic compounds. Establishing this relationship reduced the size of the parameter estimation problem and yielded good agreement between model predictions and reported equilibrium extraction data, validating the property estimates for the organic phase species. Design exploration and optimization results map the space of feasible solvent extraction column configurations and identify the set of optimal design parameter values that meet recovery and purity targets.

Critical materials↗

Data-driven predictions of the time remaining until critical global warming thresholds are reached

Leveraging artificial neural networks (ANNs) trained on climate model output, we use the spatial pattern of historical temperature observations to predict the time until critical global warming thresholds are reached. Although no observations are used during the training, validation, or testing, the ANNs accurately predict the timing of historical global warming from maps of historical annual temperature. The central estimate for the 1.5 °C global warming threshold is between 2033 and 2035, including a ±1σ range of 2028 to 2039 in the Intermediate (SSP2-4.5) climate forcing scenario, consistent with previous assessments. However, our data-driven approach also suggests a substantial probability of exceeding the 2 °C threshold even in the Low (SSP1-2.6) climate forcing scenario. While there are limitations to our approach, our results suggest a higher likelihood of reaching 2 °C in the Low scenario than indicated in some previous assessments—though the possibility that 2 °C could be avoided is not ruled out. Explainable AI methods reveal that the ANNs focus on particular geographic regions to predict the time until the global threshold is reached. Our framework provides a unique, data-driven approach for quantifying the signal of climate change in historical observations and for constraining the uncertainty in climate model projections. Given the substantial existing evidence of accelerating risks to natural and human systems at 1.5 °C and 2 °C, our results provide further evidence for high-impact climate change over the next three decades.

54 ENVIRONMENTAL SCIENCES↗

USING HINODE/EXTREME-ULTRAVIOLET IMAGING SPECTROMETER TO CONFIRM A SEISMOLOGICALLY INFERRED CORONAL TEMPERATURE

The Extreme-Ultraviolet Imaging Spectrometer on board the HINODE satellite is used to examine the loop system described in Marsh et al. by applying spectroscopic diagnostic methods. A simple isothermal mapping algorithm is applied to determine where the assumption of isothermal plasma may be valid, and the emission measure locii technique is used to determine the temperature profile along the base of the loop system. It is found that, along the base, the loop has a uniform temperature profile with a mean temperature of 0.89 +- 0.09 MK which is in agreement with the temperature determined seismologically in Marsh et al., using observations interpreted as the slow magnetoacoustic mode. The results further strengthen the slow mode interpretation, propagation at a uniform sound speed, and the analysis method applied in Marsh et al. It is found that it is not possible to discriminate between the slow mode phase speed and the sound speed within the precision of the present observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovering the 3D Structure and Dynamics of the Sun-Interstellar Medium System on a Global Scale Los Alamos LDRD Report

We discover the 3D plasma structure of the Sun-interstellar medium interaction region, called the heliosheath. This is enabled by (1) the completion of a full solar cycle of observations of hydrogen energetic neutral atoms (ENAs) emanating from this region and detected by the Los Alamos-led IBEX-Hi ENA imager on NASA’s Interstellar Boundary Explorer (IBEX) mission, and (2) the development of tools to fully exploit all data from the IBEX-Hi imager, leading to a significant increase in the effective instrument sensitivity. This effort prepares us for optimizing the design and data exploitation of the IMAP-Hi imager, the Los Alamos-led next generation imager that will fly on the Interstellar Mapping and Acceleration Probe (IMAP) mission, currently under production. This project realized its goals as evidenced by two main outcomes: (1) The publication of the first-ever empirical 3D map of the interstellar boundary, and (2) the development and release of a new validated ENA data set that has tripled the amount of data available for scientific analysis of the outer heliosphere.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of Exploding Wire Tests Using Alegra-NG

Exploding wire tests are used to characterize materials undergoing high voltage loading and to validate computational models in a simple configuration. In this report, the materials emphasized are gold, aluminum, copper and nickel wires. Model validation is presented using the nominal model (no uncertainty) in the form of heat maps (per material) that show model bias across scalar quantities and initial voltage. Mesh convergence and uncertainty quantification is also presented.

36 MATERIALS SCIENCE↗

Evidence-based Graph Adversary Mapping (EGRAM) [Poster]

Cybersecurity companies such as CrowdStrike, Dragos, Microsoft and Unit 42 categorize Advanced Persistent Threats (APTs) using their own naming schemes. As a result, these APTs are mapped to different malware sources and campaigns, all from differing sources, leading to inconsistent mapping. Inconsistent mapping causes confusion and adds further obscurity around these groups, making it difficult to track and mitigate APT cyberattacks. The Evidence-based Graph Adversary Mapping (EGRAM) tool remediates the mapping challenge by collecting, updating and converting adversary data and their sources into a valid, codified STIX v2.1 bundle which is then stored in a Neo4j graph database. It utilizes graph traversal methods and centrality analysis to generate actionable information as a Structured Threat Intelligence Graph (STIG), based on user queries. EGRAM exists as Python code and a Jupyter Notebook that acts as a searchable, evidence-based, source of intelligence for APT groups’ artifacts and cyber campaigns.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Shotgun Immunoproteomic Approach for the Discovery of Linear B-Cell Epitopes in Biothreat Agents Francisella tularensis and Burkholderia pseudomallei

Peptide-based subunit vaccines are coming to the forefront of current vaccine approaches, with safety and cost-effective production among their top advantages. Peptide vaccine formulations consist of multiple synthetic linear epitopes that together trigger desired immune responses that can result in robust immune memory. The advantages of linear compared to conformational epitopes are their simple structure, ease of synthesis, and ability to stimulate immune responses by means that do not require complex 3D conformation. Prediction of linear epitopes through use of computational tools is fast and cost-effective, but typically of low accuracy, necessitating extensive experimentation to verify results. On the other hand, identification of linear epitopes through experimental screening has been an inefficient process that requires thorough characterization of previously identified full-length protein antigens, or laborious techniques involving genetic manipulation of organisms. In this study, we apply a newly developed generalizable screening method that enables efficient identification of B-cell epitopes in the proteomes of pathogenic bacteria. As a test case, we used this method to identify epitopes in the proteome of Francisella tularensis (Ft), a Select Agent with a well-characterized immunoproteome. Our screen identified many peptides that map to known antigens, including verified and predicted outer membrane proteins and extracellular proteins, validating the utility of this approach. We then used the method to identify seroreactive peptides in the less characterized immunoproteome of Select Agent Burkholderia pseudomallei (Bp). This screen revealed known Bp antigens as well as proteins that have not been previously identified as antigens. Although B-cell epitope prediction tools Bepipred 2.0 and iBCE-EL classified many of our seroreactive peptides as epitopes, they did not score them significantly higher than the non-reactive tryptic peptides in our study, nor did they assign higher scores to seroreactive peptides from known Ft or Bp antigens, highlighting the need for experimental data instead of relying on computational epitope predictions alone. The present workflow is easily adaptable to detecting peptide targets relevant to the immune systems of other mammalian species, including humans (depending upon the availability of convalescent sera from patients), and could aid in accelerating the discovery of B-cell epitopes and development of vaccines to counter emerging biological threats.

60 APPLIED LIFE SCIENCES↗

Achieving Metabolic Flux Analysis for S. cerevisiae at a Genome-Scale: Challenges, Requirements, and Considerations

Recent advances in 13C-Metabolic flux analysis (13C-MFA) have increased its capability to accurately resolve fluxes using a genome-scale model with narrow confidence intervals without pre-judging the activity or inactivity of alternate metabolic pathways. However, the necessary precautions, computational challenges, and minimum data requirements for successful analysis remain poorly established. This review aims to establish the necessary guidelines for performing 13C-MFA at the genome-scale for a compartmentalized eukaryotic system such as yeast in terms of model and data requirements, while addressing key issues such as statistical analysis and network complexity. We describe the various approaches used to simplify the genome-scale model in the absence of sufficient experimental flux measurements, the availability and generation of reaction atom mapping information, and the experimental flux and metabolite labeling distribution measurements to ensure statistical validity of the obtained flux distribution. Organism-specific challenges such as the impact of compartmentalization of metabolism, variability of biomass composition, and the cell-cycle dependence of metabolism are discussed. Identification of errors arising from incorrect gene annotation and suggested alternate routes using MFA are also highlighted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulating NMIS Imaging and Fission-Mapping Measurements

The Nuclear Materials Identification System (NMIS) detects and characterizes fissile and nonfissile materials using time correlations between a time-tagged source and one or more detectors. The first fieldable configuration of dedicated hardware and software was developed in the 1990s. In its original configuration, the measurement system consisted of a time-tagged source and two to four detectors. Measurements with this configuration were easily simulated using a single Monte Carlo run. The present measurement configuration is far more complex than the original. The source is now divided into multiple neutron cones; significantly more detectors are included; and the source, detectors, and object being interrogated can all be moved during the measurement to capture different views of the object. In addition to the hardware changes, the software can now reconstruct high-resolution tomographs of the 14 MeV neutron attenuation coefficients and fission sites inside the object. This work shows how a complex measurement of an object that consists of both fissile and nonfissile parts can be simulated by using multiple input decks and combining the resulting output into the desired format. The results of this simulation were then reconstructed using the imaging and fission-mapping software used with measurements. These reconstructions are consistent with the original model, thus validating the simulation method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Management of Irradiated Control Rods: Cost of an Industrial Approach - 18009

This paper concerns the sorting of irradiated control rods that can be done to limit the volume of Intermediate Level Long-lived Waste. More specifically it assesses the cost of an industrial approach. For this we used numerical simulations, penalizing hypotheses and measurements. The cost is given in term of the increased volume of the control rods placed into deep geological storage. To calculate the radioactive inventories, we have developed a calculation scheme which includes a mapping of the neutron flux, a calculation of the isotopic compositions evolution, and a validation of the results. For the state of the art simulations, all operational fuel loading patterns were considered and coupled with all effective power distributions. The analysis of the calculated results shows that the simulations produce a slight overestimation of the measurements. For envelope simulations, penalizing fuel loading patterns and nominal power distribution conditions were used. Most of the radionuclides needed to declare the radiological inventories are difficult to measure. Therefore, for each radionuclide a scaling factor referred to a key radionuclide, can be calculated. Then during the dismantling operations these calculated scaling factors are multiplied by the measured key radionuclide to determine the radiological inventory. The industrial approach consists of combining envelope simulations with scaling factors. Applied to PWR control rods, the industrial approach overestimates the radiological inventories by a factor of 2. As such, the calculated position of the Intermediate Level Long Lived part limit moves +6 cm. Compared to the 1 meter of the control rod pins classified as Intermediate Level Long Lived, the industrial approach would increase by 6 % the volume of the control rods placed into the deep geological storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inference of the optical depth to reionization τ from Planck CMB maps with convolutional neural networks

The optical depth to reionization, τ, is the least constrained parameter of the cosmological Λ cold dark matter (ΛCDM) model. To date, its most precise value is inferred from large-scale polarized cosmic microwave background (CMB) power spectra from the High Frequency Instrument (HFI) aboard the Planck satellite. These maps are known to contain significant contamination by residual non-Gaussian systematic effects, which are hard to model analytically. Therefore, robust constraints on τ are currently obtained through an empirical cross-spectrum likelihood built from simulations. In this paper, we present a likelihood-free inference of τ from polarized Planck HFI maps which, for the first time, is fully based on neural networks (NNs). NNs have the advantage of not requiring an analytical description of the data and can be trained on state-of-the-art simulations, combining the information from multiple channels. By using Gaussian sky simulations and Planck SRoll2 simulations, including CMB, noise, and residual instrumental systematic effects, we trained, tested, and validated NN models considering different setups. We inferred the value of τ directly from Stokes Q and U maps at ~4° pixel resolution, without computing angular power spectra. On Planck data, we obtained τ NN = 0.0579 ± 0.0082, which is compatible with current EE cross-spectrum results but with a ~30% larger uncertainty, which can be assigned to the inherent nonoptimality of our estimator and to the retraining procedure applied to avoid biases. While this paper does not improve on current cosmological constraints on τ, our analysis represents a first robust application of NN-based inference on real data, and highlights its potential as a promising tool for complementary analysis of near-future CMB experiments, also in view of the ongoing challenge to achieve the first detection of primordial gravitational waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Results: Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system’s ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. Conclusions: The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.

07 ISOTOPE AND RADIATION SOURCES↗