Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Design of Phosphor Thermometry System for Transient High Heat Flux Surface Thermometry

Abstract: A transformative calibration methodology is presented for predicting transient surface temperatures in a thermally conducting medium from in-depth, time-varying temperature measurements. The surface temperature is resolved using two experimental runs and a newly devised first-kind Volterra integral equation. The first experimental run involves calibration with known surface temperature while the second run involves resolving the surface temperature of interest through the ill-posed integral equation. This paper presents the concept genesis and numerically demonstrates the concept for feasibility, robustness, stability and accuracy. From this demonstration, we propose to implement surface placed thermographic phosphors in the calibration stage of the inverse method for estimating the required surface temperature. As a preliminary study, we consider transient, constant property, onedimensional heat conduction in a semi-infinite medium. It is mathematically demonstrated that a Volterra integral equation of the first kind is developed for estimating the surface temperature using a calibrated system (host material and sensor). Sensor characterization, explicit sensor positioning and thermophysical properties are implicitly contained in the new calibration integral equation. The calibration integral equation displays only four terms; namely, the measured front surface temperature and corresponding measured in-depth temperature response associated with the calibration run; and, the unknown surface temperature and its measured in-depth temperature response associated with the second run. Preliminary numerical results indicate the merit of the concept. This paper suggests using thermographic phosphors for estimating the surface temperature in the calibration portion of the process owing to their rapid thermal response, good surface thermal contact characteristics and lack of capacitance for assuring minimal delay. Though the present paper describes the theoretical basis for resolving such problems, it is intended for near-term application using the UTK s high-heat flux laser facility which is presently under development

Fluorescence thermometry↗

Detection of VX Simulants Using Piezoresistive Microcantilever Sensors

Piezoresistive microcantilever sensors may be used in a variety of sensing applications, including chemical analytes and some types of biological species. These sensors employ a tiny piezoresistive microcantilever functionalized with a “sensing material” that acts as a probe for the desired analyte. In this study, the microcantilever was partially embedded into the sensing material, producing a sensor element that is highly rigid and resistant to shock, making it suitable for portable or handheld operation. The sensing material matrix used was Hypol, a hydrogel capable of preserving the bio-functionality of molecules embedded into it. This matrix was combined with acetylcholinesterase to form the finished sensing material. Results of exposing these sensors to a VX simulant, malathion, are presented for both vapor and liquid environments.

Piezoresistive microcantilever, VX simulants, dete↗

Optical fiber sensors for the non-destructive evaluation of materials

The operation of the modal domain vibration sensor was demonstrated in several simple vibrational systems. Two apparent advantages are the sensors bandwidth and sensitivity. An inherent drawback of standard vibration detection devices is their rapid cost increase with high frequency bandwidth. This sensor showed consistent response in the freqency range of 1.5 to 400 Hz. By imparting very small but measurable excitations in the structures, the sensors ability to respond to very low order vibration induced strain was established. Dynamic ranges on the order of 18 to 22 dB for the CF beam and string systems respectively were observed. The sensor itself represents a very simple system: a coherent source, a single fiber and a low bandwidth detector. The inherent advantages of ruggedness and immunity to external radiation can also be added. Finally, the sensor minimally impairs structural motion through loading, an advantage in monitoring small vibrations or lightweight structures. Some drawbacks of the sensor are also noted.

Source record↗

Analytical modeling and sensor monitoring for optimal processing of polymeric composite material systems

Process simulation models and cure monitoring sensors are discussed for use in optimal processing of fiber-reinforced composites. Analytical models relate the specified temperature and pressure cure cycle to the thermal, chemical, and physical processes occurring in the composite during consolidation and cure. Frequency-dependent electromagnetic sensing (FDEMS) is described as an in situ sensor for monitoring the composite curing process and for verification of process simulation models. A model for resin transfer molding of textile composites is used to illustrate the predictive capabilities of a process simulation model. The model is used to calculate the resin infiltration time, fiber volume fraction, resin viscosity, and resin degree of cure. Results of the model are compared with in situ FDEMS measurements.

Loos, Alfred C.↗

Update on Ultrasonic Thermometry Development at Idaho National Laboratory

The Idaho National Laboratory (INL) has initiated an effort to evaluate the viability of using ultrasonic thermometry technology as an improved sensor for detecting temperature during irradiation testing of advanced fuels proposed within the Fuel Cycle Research and Development (FCR&D) program sponsored by the U.S. Department of Energy (US DOE). Ultrasonic thermometers (UTs) work on the principle that the speed at which sound travels through a material (acoustic velocity) is dependent on the temperature of the material. UTs have several advantages over other types of temperature sensors . UTs can be made very small, as the sensor consists only of a small diameter rod which may or may not require a sheath. Measurements may be made up to very high temperature (near the melting point of the sensor material) and, as no electrical insulation is required, shunting effects observed in traditional high temperature thermocouple applications are avoided. Most attractive, however, is the ability to introduce multiple acoustic discontinuities into the sensor, as this enables temperature profiling with a single sensor. The current paper presents initial results from FCR&D UT development efforts. These developments include improved methods for fabricating magnetostrictive transducers and joining them to waveguides, characterization of candidate sensor materials appropriate for use in FCR&D fuels irradiations (both ceramic fuels in inert gas and sodium bonded metallic fuels), enhanced signal processing techniques, and tests to determine potential accuracy and resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid piezoelectric microresonator

A hybrid ferroelectric/non-ferroelectric piezoelectric microresonator is disclosed. The hybrid microresonator uses a ferroelectric layer as the actuator as ferroelectric materials typically have higher actuation coefficients than non-ferroelectric piezoelectric materials. The hybrid microresonator uses a non-ferroelectric piezoelectric layer as the sensor layer as non-ferroelectric piezoelectric materials typically have higher sensing coefficients than ferroelectric materials. This hybrid microresonator design allows the independent optimization of actuator and sensor materials. This hybrid microresonator design may be used for bulk acoustic wave contour mode resonators, bulk acoustic wave solidly mounted resonators, free-standing bulk acoustic resonators, and piezoelectric transformers.

Griffin, Benjamin↗

Fiber Optic Sensor Components and Systems for Smart Materials and Structures

The general objective of the funded research effort has been the development of discrete and distributed fiber sensors and fiber optic centered opto-electronic networks for the intelligent monitoring of phenomena in various aerospace structures related to NASA Marshall specific applications. In particular, we have proposed and have been developing technologies that we believe to be readily transferrable and which involve new fabrication techniques. The associated sensors developed can be incorporated into the matrix or on the surfaces of structures for the purpose of sensing stress, strain, temperature-both low and high, pressure field variations, phase changes, and the presence of various chemical constituents.

Lyons, R.↗

Lightning Protection and Detection System

A lightning protection and detection system includes a non-conductive substrate material of an apparatus; a sensor formed of a conductive material and deposited on the non-conductive substrate material of the apparatus. The sensor includes a conductive trace formed in a continuous spiral winding starting at a first end at a center region of the sensor and ending at a second end at an outer corner region of the sensor, the first and second ends being open and unconnected. An electrical measurement system is in communication with the sensor and receives a resonant response from the sensor, to perform detection, in real-time, of lightning strike occurrences and damage therefrom to the sensor and the non-conductive substrate material.

Dudley, Kenneth L.↗

Technical Readiness and Gaps Analysis of Commercial Optical Materials and Measurement Systems for Advanced Small Modular Reactors

This report intends to support Department of Energy’s Office of Nuclear Energy (DOE-NE) Nuclear Energy Research and Development Roadmap and industry stakeholders by evaluating optical-based instrumentation and control (I&C) concepts for advanced small modular reactor (AdvSMR) applications. These advanced designs will require innovative thinking in terms of engineering approaches, materials integration, and I&C concepts to realize their eventual viability and deployability. The primary goals of this report include: 1. Establish preliminary I&C needs, performance requirements, and possible gaps for AdvSMR designs based on best available published design data. 2. Document commercial off-the-shelf (COTS) optical sensors, components, and materials in terms of their technical readiness to support essential AdvSMR in-vessel I&C systems. 3. Identify technology gaps by comparing the in-vessel monitoring requirements and environmental constraints to COTS optical sensor and materials performance specifications. 4. Outline a future research, development, and demonstration (RD&D) program plan that addresses these gaps and develops optical-based I&C systems that enhance the viability of future AdvSMR designs. The development of clean, affordable, safe, and proliferation-resistant nuclear power is a key goal that is documented in the Nuclear Energy Research and Development Roadmap. This roadmap outlines RD&D activities intended to overcome technical, economic, and other barriers, which currently limit advances in nuclear energy. These activities will ensure that nuclear energy remains a viable component to this nation’s energy security.

advanced small modular reactors↗

Non-Intrusive Sensor for In-Situ Measurement of Recession Rate of Ablative and Eroding Materials

A non-intrusive sensor for in-situ measurement of recession rate of heat shield ablatives. An ultrasonic wave source is carried in the housing. A microphone is also carried in the housing, for collecting the reflected ultrasonic waves from an interface surface of the ablative material. A time phasing control circuit is also included for time-phasing the ultrasonic wave source so that the waves reflected from the interface surface of the ablative material focus on the microphone, to maximize the acoustic pressure detected by the microphone and to mitigate acoustic velocity variation effects through the material through a de-coupling process that involves a software algorithm. A software circuit for computing the location off of which the ultrasonic waves scattered to focus back at the microphone is also included, so that the recession rate of the heat shield ablative may be monitored in real-time through the scan-focus approach.

Papadopoulos, George↗