Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The millimeter wave super-Schottky diode detector

The 31 and 92 GHz measurements of the superconductor-Schottky diode extended to millimeter wavelengths by a redesign of the semiconductor interface are reported. Diodes were fabricated by pulse electroplating Pb on 2 x 10 to the 19th/cu cm p-Ga-As etched with HCl; a thin Au overplate is deposited to protect the Pb film from degradation and to improve its lifetime. The noise performance was almost ideal at 31 and 92 GHz; it was concluded that this diode is a quantum-limited-detector at 31 GHz, with excessive parasitic losses at 92 GHz.

Silver, A. H.↗

Diurnal variations of mesospheric ozone using millimeter-wave measurements

In March 1979, millimeter-wave observations of the ozone emission line at 101737 MHz were made to measure the diurnal variations in mesospheric ozone. Changes in mesospheric ozone were measured diurnally for a 10-day period. The ozone column above approximately 76 km rapidly decreased after sunrise to half value within 1 hour and was then followed by a slower (approximately 8 hours) decrease to an absolute minimum at 1600 hours. At sunset, the ozone column above approximately 76 km increased rapidly to its maximum value within 2 hours. In the 48-68 km altitude range, the ozone changes were gradual with a minimum near local noon (1200 hours).

Wilson, W. J.↗

Millimeter and submillimeter spectra of HCO/+/ and DCO/+/

The J = 0-1 transitions of six different isotopic forms of the HCO(+) molecular ion, which were investigated by Woods et al. (1975), are considered. The extension of this work into the shorter millimeter and submillimeter region is reported here, as is the measurement of these spectra through J = 4-5 for HCO(+) and J = 5-6 for DCO(+). It is noted that these measurements can be used to determine accurate rotational constants and rest frequencies for these astrophysically important species. Tables listing the observed rotational constants and spectral constants of HCO(+) and DCO(+) are included.

Sastry, K. V. L. N.↗

Millimeter wave radiometry as a means of determining cometary surface and subsurface temperature

Thermal emission spectra for a variety of cometary nucleus models were evaluated by a radiative transfer technique adapted from modeling of terrestrial ice and snow fields. It appears that millimeter wave sensing from an interplanetary spacecraft is the most effective available means for distinguishing between alternate models of the nucleus and for evaluating the thermal state of the layer which is below the instantaneous surface where modern theories of the nucleus indicate that sublimation of the cometary volatiles actually occurs.

Hobbs, R. W.↗

A search for millimeter-wave emission from HCN and other molecules in Comet Bradfield /1979l/

Limits on column densities and production rates are derived in light of negative results from a search for HCN, CS, and CH3OH millimeter-wave emissions, along with two unidentified lines observed in Comet Kohoutek (1973 XII), from Comet Bradfield (1979l) after perihelion passage. In the case of HCN, the production rate is found to be lower than that reported for Comet Kohoutek even upon scaling of measurements relative to the observed OH emission from each comet.

Ekelund, L.↗

Laboratory millimeter and submillimeter spectrum of CCH

The laboratory millimeter and submillimeter spectrum of the interstellar radical CCH has been observed and measured in the 174-350 GHz region. The fitted spectral constants are in excellent agreement with those determined from radioastronomical measurement.

Sastry, K. V. L. N.↗

Harmonic analysis approach to the 'TunneLadder' - A modified Karp circuit for millimeter-wave TWTA's

A field approach to the summed harmonic analysis of the TunneLadder structure, or modified forward-wave Karp circuit, is developed by combining TM(01) and TE(11) modes. Results suggest the suitability of this structure as a high-impedance, about 1-% bandwidth circuit, millimeter-wave forward-wave-type amplifier that is voltage tunable over about a 5-% frequency range and has excellent power handling ability. Theory gives good agreement with experimental results obtained by Karp in omega-beta dispersion and predicts qualitatively the appearances of the antisymmetric mode discussed and of the so called Hightron mode that was discussed earlier in White, Enderby and Birdsall (1964), and Enderby (1964), in addition to the desired symmetric mode.

Kosmahl, H. G.↗

The energetic molecular outflow near AFGL 961 - Millimeter-wave and infrared observations

Sensitive millimeter-wave C-12O line observations and near-infrared hydrogen recombination line observations of AFGL 961 are reported and analyzed. The observations show that the high-velocity flow has a maximum extent of at least six arcmin or 1.9 pc at the distance of AFGL 961. The flow is anisotropic and the emission profiles are asymmetric in velocity. The mass of the gas involved in the flow is determined to be approximately 19 solar masses, and the kinetic energy of this gas is estimated to be about 8 x 10 to the 46th ergs. These observations are interpreted as evidence that an energetic bipolar outflow of molecular gas is occurring near AFGL 961. Comparison of infrared recombination line data, radio continuum, and CO observations shows that a strong, ionized, stellar wind would not be a sufficient force to drive the outflow. The effects of the outflow on the surrounding molecular cloud was also investigated.

Lada, C. J.↗

Millimeter wave satellite communication studies. Results of the 1981 propagation modeling effort

Theoretical modeling associated with rain effects on millimeter wave propagation is detailed. Three areas of work are discussed. A simple model for prediction of rain attenuation is developed and evaluated. A method for computing scattering from single rain drops is presented. A complete multiple scattering model is described which permits accurate calculation of the effects on dual polarized signals passing through rain.

Stutzman, W. L.↗

Moisture sounding at millimeter wavelengths /94/183 GHz/ at high altitudes

A moisture sounding radiometer at millimeter wavelengths has been developed for high altitude measurements onboard NASA's WB-57F aircraft. Three channels about the 183.3 GHz water vapor line permit measurement of the atmospheric water vapor profile. A single window channel at 94 GHz provides correction for clouds over the ocean and for surface emissivity variations over land. The instrument is an imaging radiometer operating under microprocessor control throughout each data flight. The system is contained within two packages integrated into the WB-57F pallet. A ground support system was used to perform a quick-look analysis of the data collected immediately following each flight.

Gagliano, J. A.↗

Submillimeter, millimeter, and microwave spectral line catalogue

This report describes a computer accessible catalogue of submillimeter, millimeter, and microwave spectral lines in the frequency range between 0 and 10000 GHz (i.e., wavelengths longer than 30 micrometers). The catalogue can be used as a planning guide or as an aid in the identification and analysis of observed spectral lines. The information listed for each spectral line includes the frequency and its estimated error, the intensity, lower state energy, and quantum number assignment. The catalogue has been constructed using theoretical least squares fits of published spectral lines to accepted molecular models. The associated predictions and their estimated errors are based upon the resultant fitted parameters and their covariances. Future versions of this catalogue will add more atoms and molecules and update the present listings (151 species) as new data appear. The catalogue is available from the authors as a magnetic tape recorded in card images and as a set of microfiche records.

Poynter, R. L.↗

Considerations for millimeter wave printed antennas

Calculated data are presented on the performance of printed antenna elements on substrates which may be electrically thick, as would be the case for printed antennas at millimeter wave frequencies. Printed dipoles and microstrip patch antennas on polytetrafluoroethylene (PTFE), quartz, and gallium arsenide substrates are considered. Data are given for resonant length, resonant resistance, bandwidth, loss due to surface waves, loss due to dielectric heating, and mutual coupling. Also presented is an optimization procedure for maximizing or minimizing power launched into surface waves from a multielement printed antenna array. The data are calculated by a moment method solution.

Pozar, D. M.↗

The laboratory millimeter and submillimeter spectrum of HCO

The rotational absorption frequencies of 68 new lines from the HCO radical in its ground electronic state have been measured in the millimeter and submillimeter spectral region. The large zero-field data set acquired has allowed the complex spectrum of this light asymmetric rotor with unpaired electronic spin and magnetic hyperfine interactions to be completely analyzed to within experimental accuracy for the first time. The wide range of states observed provides a highly accurate map of the rotational frequencies of the formyl radical, which should enable the abundance and excitation of interstellar HCO to be examined in detail.

Blake, G. A.↗

Two-beam interferometer for optical constants measurements at near-millimeter wavelengths

A simple and versatile instrument for the measurement of optical constants in the near millimeter spectral region is described. Studies of quasi-optical components used in this instrument for effective beam transmission and control are reported. These studies include transmission characteristics of dielectric waveguides and performance of a variable coupler based on frustrated total internal reflection. Operation of this instrument as a two-beam interferometer for determining the index of refraction or as a device to measure transmission for determining the absorption coefficient are described. Values measured with this instrument at 245 GHz, using an optically pumped molecular laser as the source, are reported for several low-loss materials. Appropriate corrections and error estimates are discussed. The potential for improvement and increased accuracies are discussed.

Jones, C. R.↗

Automatic millimeter wave mixer noise figure measurements

Systems for making automatic noise figure measurements of millimeter wave mixers have been developed using both analog and digital techniques. The effect of IF mismatch on the measured noise figures is also determined with these methods (Forsythe, 1982). The measurement systems are versatile enough to be used to measure the noise figure of receivers anywhere from 30 to 300 GHz.

Forsythe, R. E.↗

Laboratory millimeter and submillimeter spectra of HNO and DNO

The identification of interstellar molecular species via the detection of one spectral line has recently become subject to close scrutiny. The radical HNO falls into the class of interstellar molecules identified in this manner. To corroborate this identification, observation of additional spectral lines is necessary. In this paper, laboratory millimeter and submillimeter wave spectra of both HNO and DNO are reported in the frequency region 150-500 GHz. Based on these spectral line measurements, models for HNO and DNO have been constructed to yield accurate frequencies for all rotational transitions of these species below 500 GHz involving J values smaller than 10. The spectral lines can be utilized by radio astronomers to confirm the identification of interstellar HNO and to search for interstellar DNO.

Sastry, K. V. L. N.↗