Search NASA⌕ Search

SEARCH · Search NASA

Results for “multi- spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Vertical Distribution of Aersols and Water Vapor Using CRISM Limb Observations

Near-infrared spectra taken in a limb-viewing geometry by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) on-board the Mars Reconnaissance Orbiter (MRO) provide a useful tool for probing atmospheric structure. Specifically, the observed radiance as a function of wavelength and height above the limb allows the vertical distribution of both dust and ice aerosols to be retrieved. These data serve as an important supplement to the aerosol profiling provided by the MRO/MCS instrument allowing independent validation and giving additional information on particle physical and scattering properties through multi-wavelength studies. A total of at least ten CRISM limb observations have been taken so far covering a full Martian year. Each set of limb observations nominally contains about four dozen scans across the limb giving pole-to-pole coverage for two orbits at roughly 100 and 290 W longitude over the Tharsis and Syrtis/Hellas regions, respectively. At each longitude, limb scans are spaced roughly 10 degrees apart in latitude, with a vertical spatial resolution on the limb of roughly 800 m. Radiative transfer modeling is used to model the observations. We compute synthetic CRISM limb spectra using a discrete-ordinates radiative transfer code that accounts for multiple scattering from aerosols and accounts for spherical geometry of the limb observations by integrating the source functions along curved paths in that coordinate system. Retrieved are 14-point vertical profiles for dust and water ice aerosols with resolution of 0.4 scale heights between one and six scale heights above the surface. After the aerosol retrieval is completed, the abundances of C02 (or surface pressure) and H20 gas are retrieved by matching the depth of absorption bands at 2000 nm for carbon dioxide and at 2600 run for water vapor. In addition to the column abundance of water vapor, limited information on its vertical structure can also be retrieved depending on the signal available from aerosol scattering.

Smith, Michael D.↗

Quantification of complex protective surface oxide layer formed during plasma jet exposure of multicomponent ultra-high temperature carbides

Multicomponent ultra-high temperature ceramics (MC-UHTCs) has garnered attention due to their improved thermo-mechanical and oxidation properties. MC-UHTC was progressively formed by adding a UHTC component at each step, producing binary, ternary and quaternary UHTC systems, processed by spark plasma sintering (SPS). Here, we investigate the role of multi-elements and thermochemical stability of the surface oxide layer formed during plasma arc jet exposure (T > 2500 °C) of MC-UHTCs using core-level X-ray photoelectron spectroscopy (XPS) correlated with the structural investigation. The results indicate that adding a UHTC component improves oxidation resistance due to the assemblage of refractory phases forming complex mixed oxides via preferential oxidation. XPS spectra of Ta4f, Nb3d, Ti1p, and Hf4f showed that the nature of the chemical bonds switched from metal carbides to metal oxides (metal oxy-carbides) in the binary system with retained metal carbides in ternary and quaternary UHTCs. The absence of a metal carbide peak in the high-resolution C1s scan of the binary system also supports this finding. The principal complex mixed oxide phases emanate in the exiguous oxidation of MC-UHTCs are quantified using Rietveld analysis. Overall, this study suggests that MC-UHTC is a promising material for possible application in thermal protection systems (TPS).

36 MATERIALS SCIENCE↗

Revealing Nanoscale Chemical Heterogeneities in Polycrystalline Mo-BiVO 4 Thin Films

The activity of polycrystalline thin film photoelectrodes is impacted by local variations of the material properties due to the exposure of different crystal facets and the presence of grain/domain boundaries. Here a multi-modal approach is applied to correlate nanoscale heterogeneities in chemical composition and electronic structure with nanoscale morphology in polycrystalline Mo-BiVO 4 . By using scanning transmission X-ray microscopy, the characteristic structure of polycrystalline film is used to disentangle the different X-ray absorption spectra corresponding to grain centers and grain boundaries. Comparing both spectra reveals phase segregation of V 2 O 5 at grain boundaries of Mo-BiVO 4 thin films, which is further supported by X-ray photoelectron spectroscopy and many-body density functional theory calculations. Theoretical calculations also enable to predict the X-ray absorption spectral fingerprint of polarons in Mo-BiVO 4 . After photo-electrochemical operation, the degraded Mo-BiVO 4 films show similar grain center and grain boundary spectra indicating V 2 O 5 dissolution in the course of the reaction. Overall, these findings provide valuable insights into the degradation mechanism and the impact of material heterogeneities on the material performance and stability of polycrystalline photoelectrodes.

36 MATERIALS SCIENCE↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Thermal decoupling of deuterium and tritium during the ICF shock-convergence phase

We report that a series of thin glass-shell shock-driven DT gas-filled capsule implosions was conducted at the OMEGA laser facility. These experiments generate conditions relevant to the central plasma during the shock-convergence phase of ablatively driven inertial confinement fusion (ICF) implosions. The spectral temperatures inferred from the DTn and DDn spectra are most consistent with a two-ion-temperature plasma, where the initial apparent temperature ratio, $\frac{T_T}{T_P}$, is 1.5. This is an experimental confirmation of the long-standing conjecture that plasma shocks couple energy directly proportional to the species mass in multi-ion plasmas. The apparent temperature ratio trend with equilibration time matches expected thermal equilibration described by hydrodynamic theory. This indicates that deuterium and tritium ions have different energy distributions for the time period surrounding shock convergence in ignition-relevant ICF implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Spectral Analysis of Singular Values as a Test Metric for IMMAT Trials

One of many challenges in the implementation of multiple exciter testing is establishing a reasonable set of test metrics to measure the quality of testing. This is especially true in the application of Impedance Matched Multi-Axis Testing; in that it is possible to have very large spectral density matrices that serve as reference criteria. While there exist plotting schemes to view a spectral density matrix, it is often necessary to break the overlay of reference and test results into subsections of the matrices to get sufficient resolution to interpret the data. In addition, as one attempts to control multiple locations on a structure, implementation of classical single degree-of freedom test tolerances across all channels and associated cross spectra is simply not feasible. Hence it is challenging to evaluate overall test quality. The use of spectral views of the dominant singular values from the singular value decomposition of the spectral density matrices and metrics based upon them is proposed for establishing a set of compact metrics for evaluating test quality. A laboratory experiment will be included to demonstrate this proposed technique.

Impedance Matched Multi-Axis Testing↗

Development of CDZNTE Detectors for Low-Energy Gamma-Ray Astronomy

Under this grant the UC Berkeley PI, K. Hurley, joined a Goddard-led effort to develop large area, multi-pixel Cadmium-Zinc-Telluride (CdZnTe, or CZT) detectors for gamma-ray astronomy. His task was to advise the project of new developments in the area of cosmic gamma-ray bursts, in order to focus the detector development effort on the construction of an instrument which could be deployed on a spacecraft to localize and measure the energy spectra of bursts with good angular and energy resolution, respectively. UC Berkeley had no hardware role in this proposal. The result of this effort was the production, at Goddard, of five CZT prototype modules. A proposal was written for SWIFT, a MIDEX mission to study cosmic gamma-ray bursts. One experiment aboard SWIFT is the Burst Arcminute Telescope (BAT), which consists of a 5200 sq cm hard X-ray detector and a coded mask. The detector comprises 256 CZT modules, each containing 128 4 x 4 x 2 mm CZT detectors. Each detector is read out using an ASIC. The angular resolution achieved with this mask/array combination is 22 arcminutes, and a strong gamma-ray burst can be localized to an accuracy of 4 arcminutes in under 10 seconds. The energy resolution is typically 5 keV FWHM at 60 keV, and the energy range is 10 - 150 keV. The BAT views 2 steradians, and its sensitivity is such that the instrument can detect 350 gamma-ray burst/year, localizing 320 of them to better than 4 arcminute accuracy. The BAT concept therefore met the science goals for gamma-ray bursts. The UCB effort in the SWIFT proposal included the scientific objectives for gamma-ray bursts, and the assembly of a team of optical and radio observers who would use the BAT data to perform rapid multi-wavelength searches for the counterparts to bursts. This proposal was submitted to NASA and peer-reviewed. In January 1999 it was one of five such proposals selected for a Phase A study. This study was completed in June, and SWIFT was formally presented to NASA in September. It appeared that a final selection of two MIDEX missions for flight was imminent. However, the final selection was deferred at the last minute due to the uncertainty in NASA's OSS budget.

Gehrels, N.↗

Analysis of remote sensing data collected for detection and mapping of oil spills: Reduction and analysis of multi-sensor airborne data of the NASA Wallops oil spill exercise of November 1978

Airborne, remotely sensed data of the NASA Wallops controlled oil spill were corrected, reduced and analysed. Sensor performance comparisons were made by registering data sets from different sensors, which were near-coincident in time and location. Multispectral scanner images were, in turn, overlayed with profiles of correlation between airborne and laboratory-acquired fluorosensor spectra of oil; oil-thickness contours derived (by NASA) from a scanning fluorosensor and also from a two-channel scanning microwave radiometer; and synthetic aperture radar X-HH images. Microwave scatterometer data were correlated with dual-channel (UV and TIR) line scanner images of the oil slick.

Source record↗

Use of Spectral Analysis of Singular Values as a Test Metric for Impedance Matched Multi-Axis Test Trials

One of many challenges in the implementation of multiple exciter testing is establishing a reasonable set of test metrics to measure the quality of testing. This is especially true in the application of Impedance Matched Multi-Axis Testing; in that it is possible to have very large spectral density matrices that serve as reference criteria. While there exist plotting schemes to view a spectral density matrix, it is often necessary to break the overlay of reference and test results into subsections of the matrices to get sufficient resolution to interpret the data. In addition, as one attempts to control multiple locations on a structure, implementation of classical single degree-of freedom test tolerances across all channels and associated cross spectra is simply not feasible. Hence it is challenging to evaluate overall test quality. The use of spectral views of the dominant singular values from the singular value decomposition of the spectral density matrices and metrics based upon them is proposed for establishing a set of compact metrics for evaluating test quality. A laboratory experiment will be included to demonstrate this proposed technique.

Vibration Testing↗

VERITAS : A density-functional theory-based multiband kinetic model for understanding x-ray spectroscopy of dense plasmas

X-ray spectroscopy has long been a powerful diagnostic tool for hot, dilute plasmas, providing insights into plasma conditions by measuring line shifts and broadenings of atomic transitions. The technique critically depends on the accuracy of atomic physics models used to interpret spectroscopic measurements for inferring plasma properties such as free-electron density and temperature. Over the past decades, the atomic and plasma physics communities have developed robust atomic physics models to account for various processes in hot, dilute classical plasmas. While these models have been successful in that regime, their applicability becomes uncertain when interpreting x-ray spectroscopy experiments of above-solid-density plasmas. Given that finite-temperature density-functional theory (DFT) offers a more accurate description of dense plasma environments, we present the development of a DFT-based multi-band kinetic model, VERITAS, designed to improve the interpretation of x-ray spectroscopic measurements in high-density plasmas produced by laser-driven spherical implosions. This work details the VERITAS model and its application to both time-integrated and time-resolved x-ray spectra from implosion experiments on OMEGA. The advantages and limitations of the VERITAS model will also be discussed, along with potential directions for advancing x-ray spectroscopy of dense and superdense plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross-Correlation Analysis of UV Profile Variations and Nonradial Pulsations in Be Stars

This study is an investigation of the role of photospheric nonradial pulsations in the mass loss processes of Be stars. Some 18 Be stars were the focus of intensive, multi-wavelength campaigns between 1985 and 1996 with the NASA/ESA International Ultraviolet Explorer Satellite (IUE) . The campaigns were designed to monitor variations in the UV flux and stellar wind lines with near simultaneous, high signal-to-noise, optical spectroscopy of photospheric lines. The high quality, ground-based spectra were required to record the subtle, blue-to-red moving bump patterns in spectral line profiles that result from nonradial pulsations. We found that the same fine variations in the UV photospheric lines can be extracted from noisy IUE spectra by cross-correlating each target spectrum with a narrow-lined standard spectrum. Time series analyses of the cross-correlation functions then reveal the periodic signals, amplitudes, phases, and modal identifications of the pulsations. Our goals are to compare such results from UV and optical time series in order to model the stellar photospheric temperature and velocity fluctuations, and to search for correlated UV wind line variations to determine whether there is a connection between pulsation and mass loss.

Gies, Douglas R.↗

Tropospheric Emissions: Monitoring of Pollution (TEMPO)

TEMPO (Tropospheric Emissions: Monitoring of Pollution) was selected in 2012 by NASA as the first Earth Venture Instrument, for launch between 2018 and 2021. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO observes from Mexico City, Cuba, and the Bahamas to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution (approximately 2.1 kilometers N/S by 4.4 kilometers E/W at 36.5 degrees N, 100 degrees W). TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry, as well as contributing to carbon cycle knowledge. Measurements are made hourly from geostationary (GEO) orbit, to capture the high variability present in the diurnal cycle of emissions and chemistry that are unobservable from current low-Earth orbit (LEO) satellites that measure once per day. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a commercial GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), formaldehyde (H2CO), glyoxal (C2H2O2), bromine monoxide (BrO), IO (iodine monoxide),water vapor, aerosols, cloud parameters, ultraviolet radiation, and foliage properties. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides these near-real-time air quality products that will be made publicly available. TEMPO will launch at a prime time to be the North American component of the global geostationary constellation of pollution monitoring together with the European Sentinel-4 (S4) and Korean Geostationary Environment Monitoring Spectrometer (GEMS) instruments.

tropospheric measurement suite↗

Wavelet flow for extragalactic foreground simulations

Extragalactic foregrounds in cosmic microwave background (CMB) observations are both a source of cosmological and astrophysical information and a nuisance to the CMB. Effective field-level modeling that captures their non-Gaussian statistical distributions is increasingly important for optimal information extraction, particularly given the low-noise observations from current and upcoming experiments. Here, we explore the use of Wavelet Flow (WF) models to tackle the novel task of modeling the field-level probability distributions of multi-component CMB secondaries and foregrounds. Specifically, we jointly train correlated CMB lensing convergence (κ) and cosmic infrared background (CIB) maps with a WF model and obtain a network that statistically recovers the input to high accuracy — the trained network generates samples of κ and CIB fields whose average power spectra are within a few percent of the inputs across all scales, and whose Minkowski functionals are similarly accurate compared to the inputs. Leveraging the multiscale architecture of these models, we fine-tune both the model parameters and the priors at each scale independently, optimizing performance across different resolutions. These results demonstrate that WF models can accurately simulate correlated components of CMB secondaries, supporting improved analysis of cosmological data. Our code and trained models can be found on this GitHub repo.

cosmological simulations↗

X-Band Scanning ARM Precipitation Radar, CF/Radial Formatted, Quality Controlled

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

xsaprcfrqc↗

Relationships between pigment composition variation and reflectance for plant species from a coastal savannah in California

Advances in imaging spectroscopy have indicated that remotely sensed reflectance measurements of the plant canopy may be used to identify and qualify some classes of canopy biochemicals; however, the manner in which differences in biochemical compositions translate into differences is not well understood. Most frequently, multiple linear regression routines have been used to correlate narrow band reflectance values with measured biochemical concentrations. Although some success has been achieved with such methods for given data sets, the bands selected by multiple regression are not consistent between data sets, nor is it always clear what physical or biological basis underlies the correlation. To examine the relationship between biochemical concentration and leaf reflectance signal we chose to focus on the visible spectrum where the primary biochemical absorbances are due to photosynthetic pigments. Pigments provide a range of absorbance features, occur over a range of concentrations in natural samples, and are ecophysiologically important. Concentrations of chlorophyll, for example, have been strongly correlated to foliar nitrogen levels within a species and to photosynthetic capacity across many species. In addition pigments effectively absorb most of the photosynthetically active radiation between 400-700 nm, a spectral region for which silicon detectors have good signal/noise characteristics. Our strategy has been to sample a variety of naturally occurring species to measure leaf reflectance and pigment compositions. We hope to extend our understanding of pigment reflectance effects to interpret small overlapping absorbances of other biochemicals in the infrared region. For this reason, selected samples were also tested to determine total nitrogen, crude protein, cellulose, and lignin levels. Leaf reflectance spectra measured with AVIRIS bandwidths and wavelengths were compared between species and within species and for differences between seasons, for changes in the the shape of the spectra. We attempt to statistically correlate these shape changes with differences in pigment compositions. In parallel with our comparisons of pigment composition and leaf reflectance, we have modified the PROSPECT leaf reflectance model to test the contributions of pigments or pigment group concentrations. PROSPECT considers a leaf as a multi-layer dielectric plane with an uneven surface. Jacquemoud adapted the basic analysis of Allen for surface effects, a leaf thickness factor, and the absorption of water and chlorophyll (actually all pigments) and the plant matrix. Our modifications to PROSPECT in the forward direction include breaking out the pigment concentration parameter into separate components for chlorophyll a and b and a number of xanthophylls and carotenes, and introducing a shift and convolution function to model the spread and shift from their in vitro measurements to their in vivo state. Further, we have considered how the matrix elements (i.e., all biochemicals and structural effects not modeled explicity) vary with species.

Ustin, Susan L.↗

A practical method for modeling temporally-averaged ocean wave frequency-directional spectra for characterizing wave energy climates

Wave energy resource characterization investigations have been hindered because frequency-directional wave spectra are not broadly available for many coastal regions due to the insufficient spatial coverage of buoy observation networks and spectral wave model hindcast outputs. We address this problem by developing and validating a practical method for approximating temporally-averaged frequency-directional wave spectra averaged over periods of months or years from bulk wave parameters, which are available at a much greater coverage and resolution than frequency-directional wave spectra. While the temporally averaged frequency-directional wave spectrum over these periods cannot be used for analyzing a single sea state, it aggregates multiple sea states, identifies dominant wave energy systems representing wave climate, and resolves their spectral characteristics. Therefore, modelling temporally averaged frequency-directional wave spectra is of great value for planning and designing wave energy projects, e.g., resource characterization, site assessment, and conceptual design of wave energy converters. Temporally-averaged frequency-directional wave spectra and related important wave energy parameters approximated using this method are found to be more accurate than commonly used parametric wave spectrum models. This method can be applied to a wide range of wave climates given its universality and high accuracy. Also, the availability of bulk wave parameters from multi-decade high-resolution wave model hindcasts is increasing.

16 TIDAL AND WAVE POWER↗

Studying of multi-shell gas-puff Z-pinches using x-ray spectroscopy with spatial resolution

Dynamics and parameters of gas-puff Z-pinch plasmas at stagnation were studied using x-ray spectroscopic diagnostics. In experiments on a 1 MA pulsed power generator, multilayer coaxial loads were made using a triple-nozzle gas-puff valve. High-luminosity spectrographs with spherically bent crystals made it possible to record spectra with high spatial resolution along the pinch axis and to record two-dimensional plasma images in separate spectral lines. Using various combinations of gases in the nozzles and adding small amounts of a gas tracer, the final structure and composition of the compressed plasma were determined. Furthermore, plasma parameters were estimated by modeling the spectra using the PrismSPECT program, but with the limitation that the spectra were time-integrated, so that spectra from different gases and at different positions may have been emitted at different times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Water Defect Stabilizes the Bi 3+ Lone-Pair Electronic State Leading to an Unusual Aqueous Hydration Structure

In this work, the aqueous hydration structure of Bi 3+ is probed using a combination of extended X-ray absorption fine structure (EXAFS) spectroscopy and density functional theory (DFT) simulations of ion-water clusters and of condensed-phase solutions. Anomalous features in the EXAFS spectra are found to be associated with a highly asymmetric first-solvent water shell. The aqueous chemistry and structure of the Bi 3+ ion is dramatically controlled by the water stabilization of a lone-pair electronic state involving the mixed 6s and 6p orbitals. This leads to a distinct multi-modal distribution of waters in the first shell that are separated by about 0.2Å. The lone-pair structure is stabilized by a collective response of multiple waters that are localized near the lone-pair anti-bonding site. The findings indicate that the lone-pair stereochemistry of aqueous Bi 3+ plays a major role in the binding of water and ligands in aqueous solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗