Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple views”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Single-Camera Panoramic-Imaging Systems

Panoramic detection systems (PDSs) are developmental video monitoring and image-data processing systems that, as their name indicates, acquire panoramic views. More specifically, a PDS acquires images from an approximately cylindrical field of view that surrounds an observation platform. The main subsystems and components of a basic PDS are a charge-coupled- device (CCD) video camera and lens, transfer optics, a panoramic imaging optic, a mounting cylinder, and an image-data-processing computer. The panoramic imaging optic is what makes it possible for the single video camera to image the complete cylindrical field of view; in order to image the same scene without the benefit of the panoramic imaging optic, it would be necessary to use multiple conventional video cameras, which have relatively narrow fields of view.

Lindner, Jeffrey L.↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable Comparative Visualization of Ensembles of Call Graphs

Optimizing the performance of large-scale parallel codes is critical for efficient utilization of computing resources. Code developers often explore various execution parameters, such as hardware configurations, system software choices, and application parameters, and are interested in detecting and understanding bottlenecks in different executions. They often collect hierarchical performance profiles represented as call graphs, which combine performance metrics with their execution contexts. The crucial task of exploring multiple call graphs together is tedious and challenging because of the many structural differences in the execution contexts and significant variability in the collected performance metrics (e.g., execution runtime). In this paper, we present Ensemble CallFlow to support the exploration of ensembles of call graphs using new types of visualizations, analysis, graph operations, and features. We introduce ensemble-Sankey , a new visual design that combines the strengths of resource-flow (Sankey) and box-plot visualization techniques. Whereas the resource-flow visualization can easily and intuitively describe the graphical nature of the call graph, the box plots overlaid on the nodes of Sankey convey the performance variability within the ensemble. Our interactive visual interface provides linked views to help explore ensembles of call graphs, e.g., by facilitating the analysis of structural differences, and identifying similar or distinct call graphs. Finally, we demonstrate the effectiveness and usefulness of our design through case studies on large-scale parallel codes.

97 MATHEMATICS AND COMPUTING↗

Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system that allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.

97 MATHEMATICS AND COMPUTING↗

Modeling an Interwoven Collimator for A 3D Endocavity Gamma Camera

Positron emission tomography (PET) and single-photon emission-computed tomography (SPECT) are important nuclear-medical imaging tools in diagnosing cancers and creating effective treatment plans. Here, commercially imaging systems are operated externally and can create 3D images of the whole body or of specific organs by rotating the gamma-ray detectors, and then employing software to reconstruct the 3D images from the multiple 2D projections at different angles of view.

36 MATERIALS SCIENCE↗

Precise linear sun sensor

An evaluation of the precise linear sun sensor relating to future mission applications was performed. The test procedures, data, and results of the dual-axis, solid-state system are included. Brief descriptions of the sensing head and of the system's operational characteristics are presented. A unique feature of the system is that multiple sensor heads with various fields of view may be used with the same electronics.

Johnston, D. D.↗

A hot wire radiant energy source for mapping the field of view of a radiometer

The design and performance of a calibration device that allows the measurement of a radiometer's field of view are described. The heart of the device is a heated 0.0254-mm (0.001-inch) diameter filament that provides a variable, isothermal line source of radiant energy against a cold background. By moving this discrete line source across the field of view of a radiometer, the radiometer's spatial response can be completely mapped. The use of a platinum filament provides a durable radiation source whose temperature is stable and repeatable to 10 K over the range of 600 to 1200 K. By varying the energy emitted by the filament, the field of view of radiometers with different sensitivities (or multiple channel radiometers) can be totally mapped.

Edwards, S. F.↗

A history of Mars atmospheric opacity in the southern hemisphere during the Viking extended mission

A history of developing opacity in the Mars southern hemisphere during the Viking extended mission has been compiled using orbiter images obtained at high altitude. Observations of changing contrasts under similar viewing conditions have been modeled by multiple-scattering intensity transfer equations that have produced a temporal description of changes in optical depth and particle-scattering properties within a network of control points. The results are presented in the form of Mercator and perspective plots for various dates.

Thorpe, T. E.↗

Advanced solidstate array spectroradiometer - Sensor and calibration improvements

The advanced solid-state array spectroradiometer (ASAS), an airborne imaging spectrometer with 30 spectral channels extending from 450-880 nm, is described. Modifications to the sensor mounting technique changed the ASAS from a fixed nadir viewing instrument to a sensor capable of multiple direction observations of surface bidirectional reflectance distribution functions. The system was flown on the NASA Ames C130 aircraft to obtain surface bidirectional reflectance measurements of vegetation; it demonstrated excellent reliability and radiometric stability.

Huegel, Frederick G.↗

A circular combustor configuration with multiple injection ports for mixing enhancement

A circular combustor design by Ghorashi (1988) which resembles a continuously-stirred tank reactor with multiple injection ports is presented with a view to the enhanced control of mixing, NO(x) reduction, and combustion efficiency maximization. Attention is given to the prototype apparatus for this type of circular combustor, which takes the form of a transparent cold-flow reactor for flow visualization studies under 'chemically frozen' conditions.

Ghorashi, B.↗

Airborne CO2 coherent lidar measurements of cloud backscatter and opacity over the ocean surface

The use of an airborne CO2 lidar to obtain cloud backscatter and extinction data at a thermal infrared wavelength is described. The extinction in this spectral region is proportional to the cloud liquid water content. The use of coherent detection results in high sensitivity and narrow field of view, the latter property greatly reducing multiple-scattering effects. Backscatter measurements in absolute units are obtained through a hard target calibration methodology. For clouds of low to moderate optical thickness at the lidar wavelength, both geometric thickness and optical thickness can be measured. The sea surface reflectance signal is used to obtain estimates of the cloud optical thickness. The utility of this technique results from studies that indicate that the spatial scale of variability of the sea surface reflectance is generally large compared with that of cloud optical thickness. Selected results are presented from data taken during flights over the Pacific Ocean.

Menzies, Robert T.↗

On the Use of Subcarriers in Future Space Missions

In this paper, the use of residual carier techniques with no subcarrier (PCM/PM) will be advocated. It will be shown that the use of the PCM/PM technique under appropriate conditions will reap many advantages without sacrificing performance. Foremost amoung these advantages is the lower bandwidth, which can be extremely useful when antenna arraying is employed or when tracking multiple spacecraft signals within the field of view of a single antenna.

recidual carrier techniques tracking signals↗

Obtaining the Grobner Initialization for the Ground Flash Fraction Retrieval Algorithm

At optical wavelengths and from the vantage point of space, the multiple scattering cloud medium obscures one's view and prevents one from easily determining what flashes strike the ground. However, recent investigations have made some progress examining the (easier, but still difficult) problem of estimating the ground flash fraction in a set of N flashes observed from space In the study by Koshak, a Bayesian inversion method was introduced for retrieving the fraction of ground flashes in a set of flashes observed from a (low earth orbiting or geostationary) satellite lightning imager. The method employed a constrained mixed exponential distribution model to describe the lightning optical measurements. To obtain the optimum model parameters, a scalar function of three variables (one of which is the ground flash fraction) was minimized by a numerical method. This method has formed the basis of a Ground Flash Fraction Retrieval Algorithm (GoFFRA) that is being tested as part of GOES-R GLM risk reduction.

Solakiewicz, R.↗

Synthetic Tracking on a Small Telescope

Synthetic tracking uses high speed (up to 10 Hz) low noise (<2e-) large format sensors ~16 Mpix along with a multi-vector shift/add algorithm that coadds multiple image frames to increase the signal to noise ratio (SNR) needed to detect (if present) multiple moving objects in the field of view (FOV). We published the application of synthetic tracking to look for asteroids in 2014 (Shao 2014), but recently have applied it more as well to Earth orbiting objects. We have begun testing the data processing graphical processing unit (GPU) array with a small telescope, a 28 cm Celestron RASA telescope and a low cost low noise 16 Mpix CMOS camera at a dark site in California. This system is now operational with a 2 sqdeg FOV and a limiting magnitude between ~16-17.5 stellar magnitudes (mag) depending on a number of observational parameters for short integration times. The instrument can be used to search for NEOs, where we use much longer integration times to get sensitivity ~ 20.5 mag (at new moon). Synthetic tracking provides significant improvements in both sensitivity and astrometric accuracy.

Turyshev, Slava G.↗

Imaging System to Measure Kinetics of Material Cluster Ejection During Exit-Surface Damage Initiation and Growth in Fused Silica

Laser-induced damage on the surface of optical components typically is manifested by the formation of microscopic craters that can ultimately degrade the optics performance characteristics. It is believed that the damage process is the result of the material exposure to high temperatures and pressures within a volume on the order of several cubic microns located just below the surface. The response of the material following initial localized energy deposition by the laser pulse, including the timeline of events and the individual processes involved during this timeline, is still largely unknown. In this work we introduce a time-resolved microscope system designed to enable a detailed investigation of the sequence of dynamic events involved during surface damage. To best capture individual aspects of the damage timeline, this system is employed in multiple imaging configurations (such as multi-view image acquisition at a single time point and multi-image acquisition at different time points of the same event) and offers sensitivity to phenomena at very early delay times. The capabilities of this system are demonstrated with preliminary results from the study of exit-surface damage in fused silica. The time-resolved images provide information on the material response immediately following laser energy deposition, the processes later involved during crater formation or growth, the material ejecta kinetics, and overall material motion and transformation. Such results offer insight into the mechanisms governing damage initiation and growth in the optical components of ICF class laser systems.

42 ENGINEERING↗

SU-E-T-208: Comparison of MR Image Quality of Various Brachytherapy Applicators for Cervical Cancer

Purpose: To compare the quality of Magnetic Resonance (MR) images of a recently-proposed novel direction-modulated brachytherapy (DMBT) tandem applicator against two conventional clinical applicators, using the current MRI clinical protocol. Methods: Three tandem applicators were compared: (1) tungsten-based DMBT applicator, (2) conventional plastic applicator and (3) conventional stainless steel applicator. Physical dimensions were 5.4, 3.8 and 3.2 for tandems (1), (2) and (3), respectively. Each applicator was placed in the same water-phantom and independently scanned using the same parameters and coil settings on a 1.5 T 450w GE scanner. Images were acquired using T2-weighted turbo-spin-echo (TSE) with 8-channel body coil. Acquisition parameters were TR/TE =7000/108 ms; acquisition matrix = 320 x 256; 30 slices with 4 mm thickness and 0.5 gap; pixel bandwidth = 122 Hz and voxel size = 0.5 x 0.625 mm2 and number of excitations (NEX) = 4. Multiple acquisitions were obtained in para-sagittal and para-axial views (with respect to the tandem axis) for each applicator. Diameters of the tandem were measured at multiple angles and multiple locations and compared to the physical dimensions of the corresponding tandems. Results: Minimal susceptibility artifact was observed with the DMBT and the plastic tandems. The stainless steel tandem produced significantly larger artifact than the first two tandems. The average diameter of the DMBT applicator measured 5.94 ± 0.3 mm. The average diameter of the plastic tandem measured 3.9 ± 0.1 mm. The maximum extent of artifact was 1.5 mm and 0.7 mm for DMBT and plastic tandems, respectively. The susceptibility artifact induced by the stainless steel tandem prevented the measurement of its diameter, and the edges of the tandem could not be identified in any acquisition. Conclusion: This work demonstrated that the plastic and the tungsten-based DMBT tandem applicators are both suitable for MRI-guided brachytherapy of cervical cancer.

60 APPLIED LIFE SCIENCES↗

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

Modified Hitschfeld-Bordan Equations for Attenuation-Corrected Radar Rain Reflectivity: Application to Nonuniform Beamfilling at Off-Nadir Incidence

As shown by Takahashi et al., multiple path attenuation estimates over the field of view of an airborne or spaceborne weather radar are feasible for off-nadir incidence angles. This follows from the fact that the surface reference technique, which provides path attenuation estimates, can be applied to each radar range gate that intersects the surface. This study builds on this result by showing that three of the modified Hitschfeld-Bordan estimates for the attenuation-corrected radar reflectivity factor can be generalized to the case where multiple path attenuation estimates are available, thereby providing a correction to the effects of nonuniform beamfilling. A simple simulation is presented showing some strengths and weaknesses of the approach.

nonuniform beamfilling↗