Performance Results from a Cold Climate Case Study for Affordable Zero Energy Homes: Preprint

The design of this 1280 square foot, 3-bedroom Denver zero energy home carefully combines envelope efficiency, efficient equipment, appliances and lighting, a photovoltaic system, and passive and active solar thermal features to exceed the net zero energy goal. In January 2006, a data acquisition system was installed in the home to monitor its performance over the course of a year. This paper presents full year of energy performance data on the home.

14 SOLAR ENERGY↗

High Performance Building Facade Solutions - PIER Final Project Report

Building facades directly influence heating and cooling loads and indirectly influence lighting loads when daylighting is considered, and are therefore a major determinant of annual energy use and peak electric demand. Facades also significantly influence occupant comfort and satisfaction, making the design optimization challenge more complex than many other building systems.This work focused on addressing significant near-term opportunities to reduce energy use in California commercial building stock by a) targeting voluntary, design-based opportunities derived from the use of better design guidelines and tools, and b) developing and deploying more efficient glazings, shading systems, daylighting systems, facade systems and integrated controls. This two-year project, supported by the California Energy Commission PIER program and the US Department of Energy, initiated a collaborative effort between The Lawrence Berkeley National Laboratory (LBNL) and major stakeholders in the facades industry to develop, evaluate, and accelerate market deployment of emerging, high-performance, integrated facade solutions. The LBNL Windows Testbed Facility acted as the primary catalyst and mediator on both sides of the building industry supply-user business transaction by a) aiding component suppliers to create and optimize cost effective, integrated systems that work, and b) demonstrating and verifying to the owner, designer, and specifier community that these integrated systems reliably deliver required energy performance. An industry consortium was initiated amongst approximately seventy disparate stakeholders, who unlike the HVAC or lighting industry, has no single representative, multi-disciplinary body or organized means of communicating and collaborating. The consortium provided guidance on the project and more importantly, began to mutually work out and agree on the goals, criteria, and pathways needed to attain the ambitious net zero energy goals defined by California and the US.A collaborative test, monitoring, and reporting protocol was also formulated via the Windows Testbed Facility in collaboration with industry partners, transitioning industry to focus on the importance of expecting measured performance to consistently achieve design performance expectations. The facility enables accurate quantification of energy use, peak demand, and occupant comfort impacts of synergistic facade-lighting-HVAC systems on an apples-to-apples comparative basis and its data can be used to verify results from simulations. Emerging interior and exterior shading technologies were investigated as potential near-term, low-cost solutions with potential broad applicability in both new and retrofit construction. Commercially-available and prototype technologies were developed, tested, and evaluated. Full-scale, monitored field tests were conducted over solstice-to-solstice periods to thoroughly evaluate the technologies, uncover potential risks associated with an unknown, and quantify performance benefits. Exterior shading systems were found to yield net zero energy levels of performance in a sunny climate and significant reductions in summer peak demand. Automated interior shading systems were found to yield significant daylighting and comfort-related benefits.In support of an integrated design process, a PC-based commercial fenestration (COMFEN) software package, based on EnergyPlus, was developed that enables architects and engineers to quickly assess and compare the performance of innovative facade technologies in the early sketch or schematic design phase. This tool is publicly available for free and will continue to improve in terms of features and accuracy. Other work was conducted to develop simulation tools to model the performance of any arbitrary complex fenestration system such as common Venetian blinds, fabric roller shades as well as more exotic innovative facade systems such as optical louver systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CO 2 Capture Going BIG

“Currently, the world is way off track in meeting the Paris Agreement climate goals. It cannot get back on track without CCS”. This statement, issued by the Global CCS Institute in its recent report on The Global Status of CCS (Carbon Capture and Storage), underlines the importance of developing new methods and technologies to reduce the amount of greenhouse gases in the atmosphere. Since the beginning of the industrial revolution, the atmospheric CO 2 concentration has increased from 280 to 410 parts per million (ppm), which is a 46% increase. Most of the added CO 2 can be attributed to fossil fuel emissions from energy production (i.e., burning coal, natural gas, and oil) and other industries (e.g., cement, steel). The CO 2 level will likely continue to rise in the coming decades, as the world population and the energy consumption continue to increase and rely on fossil fuels. While the Earth’s ecosystems have mechanisms for reducing the amounts of CO 2 present in the atmosphere, absorbing roughly half of our annual emissions, the other half, consisting of about 18 gigatonnes of carbon dioxide per year, will have to be addressed through CCS technologies. At the same time, the global average temperature has already risen about 1 °C over the course of the 20th century, and will likely exceed the 1.5 °C increase limit in a few decades. Undeniably, as the Earth is out of energy balance with the current atmospheric composition, there is more warming in the pipeline even if the global emissions were to be cut to zero today. A recent report from the U.S. National Academy of Sciences concluded that limiting the increase in the global temperature to less than 2 °C by the end of this century becomes exceedingly challenging without large-scale deployment of Negative Emissions Technologies (NETs). NETs, such as Direct Air Capture (DAC), remove CO 2 out of the atmosphere, in effect reducing past emissions. They also can address dispersed emissions from transportation and buildings, which currently account to about 50% of global annual emissions.

01 COAL, LIGNITE, AND PEAT↗

Hot Springs and Geysers: Exploring Historical and Modern Impacts of Geothermal Energy Production on Associated Natural Surface Systems and Standardizing Management Practices

Surface thermal features, most notably hot springs and geysers are increasingly being recognized for their importance to ecosystems, indigenous cultures, and in some cases agriculture, recreation, and tourism. Geothermal project development poses a potential risk to these natural features but current regulatory requirements for assessing and managing these risks during exploration, permitting and monitoring are somewhat inconsistent and unpredictable across different geothermal fields. This has resulted in uncertainty and increases in exploration risk for geothermal energy developers that have led to costly project delays, cancellations, or hesitation to commit. Varying regulatory requirements may also influence public perception, fostering confusion, distrust and ultimately opposition to geothermal projects, further contributing to project delays or cancellations. At a time when there is an increasing urgency for reliable baseload clean energy, geothermal is a net-zero, renewable solution that additionally provides access to more equitable and environmentally just clean power. Continued integration of geothermal energy into the national energy roadmap can be facilitated through consistent and predictable permitting, providing regulators the framework they need, developers a clear path forward, and transparency that the public deserves. This project, currently in its beginning phases, seeks to address this important issue by providing a technical basis from which to build a preliminary protocol for assessing and managing potential impacts from new or existing geothermal energy projects to surface thermal features and their associated ecosystems. Development of this preliminary protocol will be informed by (1) a literature review of well-documented case studies in the western U.S. and New Zealand to understand the range of conditions that exemplify geothermal-surface thermal systems; (2) development of generic illustrative conceptual-numerical models to quantify, understand, and predict the first-order controls (e.g., pressure and permeability) on surface flows; and (3) additional independent and scientifically rigorous evaluations of geothermal-surface thermal system case studies from the Basin and Range Province that incorporate publicly available data as well as data provided by industry through data-sharing agreements. Learning from the successes of the process used to develop the Induced Seismicity Management Protocol (ISMP), we ultimately aim to use these initial efforts as a springboard for establishing a surface thermal feature management working group that will work collaboratively to finalize the protocol as well as co-create recommended best practices for implementation. We envision that the working group will primarily be composed of representatives from regulatory entities, government agencies, Tribes, academia, national laboratories, and industry, and will include early and regular engagement with community organizations and environmental groups. This will help ensure broad acceptance and implementation of the protocol, which will facilitate a more consistent, predictable, and standardized regulatory process, and help to ensure that geothermal energy continues to provide a reliable source of clean energy, and a pathway to achieving greater energy equity in the U.S.

Best Practices↗

A Green Prison: Santa Rita Jail Creeps Towards Zero Net Energy (ZNE)

A large project is underway at Alameda County's twenty-year old 45 ha 4,000-inmate Santa Rita Jail, about 70 km east of San Francisco. Often described as a green prison, it has a considerable installed base of distributed energy resources including a seven-year old 1.2 MW PV array, a four-year old 1 MW fuel cell with heat recovery, and efficiency investments. A current US$14 M expansion will add approximately 2 MW of NaS batteries, and undetermined wind capacity and a concentrating solar thermal system. This ongoing effort by a progressive local government with considerable Federal and State support provides some excellent lessons for the struggle to lower building carbon footprint. The Distributed Energy Resources Customer Adoption Model (DER-CAM) finds true optimal combinations of equipment and operating schedules for microgrids that minimize energy bills and/or carbon emissions without 2 of 12 significant searching or rules-of-thumb prioritization, such as"efficiency first then on-site generation." The results often recommend complex systems, and sensitivities show how policy changes will affect choices. This paper reports an analysis of the historic performance of the PV system and fuel cell, describes the complex optimization applied to the battery scheduling, and shows how results will affect the jail's operational costs, energy consumption, and carbon footprint. DER-CAM is used to assess the existing and proposed DER equipment in its ability to reduce tariff charges.

25 ENERGY STORAGE↗

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High R-value wall assemblies (R-40 and above) are gaining popularity in the market due to programs such as the U.S. Department of Energy Zero Energy Ready Home program, Passive House, Net Zero Energy Home challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used double-wall systems to achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double-wall systems is that there are very few new exterior details. Exterior sheathings, structural bracings, house wraps or building paper, window and door flashings, and siding attachments are usually identical to good details in conventional framed-wall systems. However, although the details in double-wall systems are very similar to those in conventional stick framing, there is sometimes less room for error. Several studies have confirmed colder temperatures of exterior sheathing in high R-value wall assemblies that do not have exterior rigid foam insulation. These colder temperatures can lead to increased chances for condensation from air exfiltration, and they have the potential to result in moisture-related problems (Straube and Smegal 2009, Arena 2014, Ueno 2015). The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and reduce material brought to landfills due to failures and resulting decay. Although this document focuses on double-wall framing techniques, the majority of the information about how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture-related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super-insulated homes. The information is applicable to both new construction and gut-rehabilitation projects in Climate Zones 5 and higher.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices Case Study: John Wesley Miller Companies - Armory Park Del Sol, Tucson, AZ

Case study of John Wesley Miller Companies, who built two net zero energy homes plus 97 other solar homes in Tucson, AZ. Masonry block walls with rigid foam exterior sheathing, rigid foam over the roof deck plus R-38 in the attic, ducts in conditioned space, 4.2 kW and 5.7 kW photovoltaics and solar water heating yielded HERS scores of 0 on the two homes.

Building America↗

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline Validation of Unstructured Grid Reynolds-Averaged Navier-Stokes Toward Flow Control

The value of the use of the Reynolds-averaged Navier-Stokes methodology for active flow control applications is assessed. An experimental flow control database exists for a NACA0015 airfoil modified at the leading edge to implement a fluidic actuator; hence, this configuration is used. Computational results are documented for the baseline wing configuration (no control) with the experimental results and assumes two-dimensional flow. The baseline wing configuration has discontinuities at the leading edge, trailing edge, and aft of midchord on the upper surface. A limited number of active flow control applications have been tested in the laboratory and in flight. These applications include dynamic stall control using a deformable leading edge, separation control for takeoff and landing flight conditions using piezoelectric devices, pulsed vortex generators, zero-net-mass oscillations, and thrust vectoring with zero-net-mass piezoelectric-driven oscillatory actuation. As yet, there is no definitive comparison with experimental data that indicates current computational capabilities can quantitatively predict the large aerodynamic performance gains achieved with active flow control in the laboratory. However, one study using the Reynolds-averaged Navier-Stokes (RANS) methodology has shown good quantitative agreement with experimental results for an isolated zero-net-mass actuator. In addition, some recent studies have used RANS to demonstrate qualitative performance gains compared with the experimental data for separation control on an airfoil. Those quantitative comparisons for both baseline and flow control cases indicated that computational results were in poor quantitative agreement with the experiments. The current research thrust will investigate the potential use of an unstructured grid RANS approach to predict aerodynamic performance for active flow control applications building on the early studies. First the computational results must quantitatively match experiments for the no-control case before proceeding to the time-dependent flow control case. This paper documents the baseline (no-control) case using an unswept airfoil configuration. The next section describes the configurations used for the computations and the experimentals. The computational approach is then described followed by results and concluding remarks.

Joslin, Ronald D.↗

Magnetic order and spin liquid behavior in [Mo 3 ] 11+ molecular magnets

Molecular magnets based on [Mo 3 ] 11+ units with one unpaired electron per trimer have attracted recent interest due to the identification of quantum spin liquid candidacy in some family members. Here, we present comprehensive measurements on polycrystalline samples of ZnScMo 3 O 8 , MgScMo 3 O 8 , and Na 3 Sc 2 Mo 5 O 16 with the same Mo 3 O 13 magnetic building blocks. In this work, the crystal structures are characterized with x-ray or neutron powder diffraction and the magnetic ground states are determined by performing ac and dc susceptibility, specific heat, neutron powder diffraction, and muon spin relaxation measurements. Our work indicates that ZnScMo 3 O 8 and MgScMo 3 O 8 have ferromagnetic Curie-Weiss temperatures of 18.5 and 11.9 K, ordered ground states with net moments (low-moment ferromagnetism or canted antiferromagnetism), and zero field ordering temperatures of $T_c$ = 6 K and $T_c$ < 2 K, respectively. On the other hand, Na 3 Sc 2 Mo 5 O 16 hosts a dynamical magnetic ground state with no evidence for magnetic ordering or spin freezing down to 20 mK despite an antiferromagnetic Curie-Weiss temperature of –36.2 K, and therefore is a candidate for quantum spin liquid behavior. By comparing the present results to past work on the same family of materials, we construct a phase diagram which illustrates that the magnetic ground states of these Mo-based molecular magnets are very sensitive to small changes in the nearest-neighbor Mo-Mo distance.

36 MATERIALS SCIENCE↗

The Institute for Advanced Composites Manufacturing and Innovation Circular Economy for Wind Workshop Report

Wind turbine blade waste is anticipated to amount to approximately 2.2 million tons or more by 2050 (more than the equivalent weight of 6 empire state buildings). However, no existing recycling technologies for the composites in wind turbines are currently at cost-parity with landfilling. As such, there is little industrial drive to recycle these materials, so they are currently buried. If it were possible to develop a circular economy for wind blades it could directly reduce material feedstock costs for many composites industries, facilitate the tremendous, anticipated growth of the domestic off-shore wind energy sector, and help the U.S. achieve net-zero manufacturing and energy generation. However, to enable circular economies for wind blades, several questions need to be answered.

17 WIND ENERGY↗

Andreev reflection at the altermagnet-superconductor interface

Altermagnets are a new class of magnetic materials, which exhibit large spin splitting, but due to the combined spin and real space group symmetry protection maintain zero net macroscopic magnetization. Such a characteristic may prove them to be superior in applications in superconducting heterostructures and thus here we investigate the Andreev reflection at the altermagnet/superconductor interface. We compare and contrast altermagnets to other magnetic materials, revealing qualitative differences in the behavior of altermagnetic junction depending on the Fermi surface orientation. We study the resonant states arising in setups with strong tunneling barriers and show that sensitivity to nonmagnetic disorder is also dependent on the orientation. In conclusion, our results provide a building block for altermagnetic superconducting heterostructures such as Josephson π junctions with superior properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plowing Through the Cost Barrier: Zero Energy K-12 Schools for Less: Preprint

There is a perception that zero energy K–12 schools cost more than conventional schools. Zero energy schools provide a number of unique benefits to school districts, students and staff, and communities. Among other things, a zero energy school requires far less energy to operate than a conventional school and uses on-site renewable energy systems to offset that reduced energy load. The money saved on energy can often be used to enhance educational programs. But does the extra value come at a premium? Research findings indicate that not only can zero energy schools be designed and built on conventional school budgets, they can cost less. In an integrated design and construction process, the cost of zero energy measures can be offset by, for example, downsizing heating, ventilating, and air-conditioning systems, reducing both life cycle and first costs. These findings are based on an examination of 88 zero energy or zero energy ready schools across the United States built during the last 15 years. The data collected on these schools include capital costs and the experiences of owners and design teams. The goal was to understand the perceived cost barrier, given that each building was built with a predetermined budget. The results will help future school stakeholders, program administrators, and design teams counter the perceived cost barriers. Successful strategies for achieving zero energy at no initial cost are presented. The lessons learned from existing zero energy schools can help transform the market such that all new schools can be zero energy.

30 DIRECT ENERGY CONVERSION↗

Attenuation of Gas Turbulence by a Nearly Stationary Dispersion of Fine Particles

Turbulence attenuation by greater than a factor of two has been observed in many practical gas flows carrying volume fractions as small as 0.01% of dispersed particles. Particles which cause such attenuation usually are smaller than the smallest scales of the turbulence and have time constants 5 to 10 times greater than the time scale of a typical turbulent eddy. That is, strongly attenuating particles usually have Stokes numbers in the range of 5 to 10, indicating that they do not respond to the turbulent fluctuations, but instead just fall through the flow responding only to the mean flow. There are two mechanisms by which free falling particles may attenuate turbulence. First, the unresponsive particles act as a drag on the turbulent eddies, passing energy from the turbulent eddies to the small scale wakes of the particles where it is quickly dissipated by viscosity. The second mechanism is more complicated. Particles falling under gravity convert gravitational potential energy to turbulent velocity fluctuations. If the particles are large, this mechanism increases the overall turbulence level. However, with moderate size particles, the small scale turbulence generated apparently distorts the turbulent eddies leading to more rapid dissipation. Unfortunately, this conclusion is supported only by circumstantial evidence to date. The objectives of the experiment are to use microgravity to separate the two mechanisms. A region of nearly-isotropic decaying turbulence with zero mean flow will be formed in a box in the microgravity environment. Different sets of particles with Stokes numbers in the range of 2 to 20 will be dispersed in the flow. With zero gravity and no mean fluid velocity the particles will have zero mean velocity. With the large Stokes numbers, the fluctuating velocities will also be small. Therefore, the only attenuation mechanism will be the direct action of the particles on the turbulence. Control experiments will also be done in which the particles fall through the measurement volume. Measurements will be acquired using a high resolution image velocimetry (PIV) system being developed specifically for work in particle-laden flows. The measurements will include the decay of the turbulence kinetic energy under various particle loadings. The spatial spectra of the turbulence will also be measured. In a second set of experiments, the interaction of a single eddy with a collection of nearly stationary particles will be examined. The eddy will be a vortex ring emitted by a jet pulse through an orifice. The distortion of the vortex under the influence of the particles will be examined to gain a better understanding of how fine particles can cause such large reductions in turbulence levels. This experiment could not be conducted in terrestrial gravity because the high particle velocities would overwhelm the relatively low speed motion of the vortex ring. This experimental program is just getting underway. The initial challenge is to build a closed facility containing reasonably homogeneous and isotropic turbulence with zero mean velocity. Our approach is to use a set of synthetic jets mounted on the periphery of a transparent plexiglass box to create the turbulence. A synthetic jet is a plenum chamber with an orifice open to the volume of interest. The volume of the chamber fluctuates periodically so alternately a jet is ejected from the volume or flow is drawn back in as a sink. The asymmetry of this situation results in a net transport of momentum and kinetic energy into the volume of interest. The present apparatus includes eight synthetic jets each powered independently by a six inch loudspeaker. The synthetic jets discharge through ejector tubes to increase the scale of the turbulence. Construction of the apparatus is now complete and preliminary flow visualization studies have been conducted. The PIV system is also under development. A compact dual-pulse YAG laser has been acquired as the light source and special software is under development to allow simultaneous measurements of both the particle phase and the fluid phase (marked by fine tracers).

Paris, A. D.↗

Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition (NYSERDA 2018). To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 in New York. The focus of this project is to significantly improve the energy efficiency over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate significant energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Scalable Method for Decarbonizing Modular Building Solutions: Preprint

The decarbonization movement emphasizes the shift in focus from energy efficiency to directly reducing global-warming impact. Blokable, LLC, a vertically integrated modular builder with an all-electric portfolio, worked with NREL on a roadmap to decarbonize its high-performance building product at a relative cost advantage by utilizing the learning curves of mass production. Previous decarbonization literature focused on either i) lifecycle assessments, or ii) efficiency measures. These decarbonization exercises were bespoke to individual building projects and did not consider positive feedback loops of builder experience or process repetition. Vertically integrated, prefab builders possess the unique ability to leverage learning and repetition to decarbonize their design-build-operate process. This collaboration between Blokable and NREL resulted in a decarbonization strategy utilizing the company's scaling and production efficiencies, on-site renewable energy and storage, and the projected evolution of building components over time based on trends and emerging legislation. The method developed here encompasses a growing business model, lifecycle carbon assessment, and projected changes in product and grid emissions over time due to existing trends and emerging legislation. This methodology incorporates learning-curve efficiencies gleaned from scaled manufacturing, as well as open-source tools integration for energy and carbon accounting. The output projects and compares cost and carbon savings per modular unit as production increases to 10,000 dwelling units annually over 15 years. The resulting roadmap illustrates a path to roughly 60% carbon savings and beyond-net-zero-energy performance at no incremental cost by 2030. The methodology can be mapped to other integrated or productized builders for methodical decarbonization.

affordable housing↗