Parametric study of single expansion ramp nozzles at subsonic/transonic speeds

The Langley Research Center has conducted a parametric investigation to determine the aeropropulsive characteristics of single expansion ramp nozzles (SERN). The SERN is a nonaxisymmetric, variable-area, internal/external expansion exhaust nozzle. Internal nozzle parameters that were varied included upper ramp length, ramp chordal angle, lower flap length, flap angle and the axial and vertical locations of nozzle throat. Convergent-divergent and convergent nozzles were included in this investigation which was conducted in the Langley 16-Foot Transonic Tunnel at Mach numbers from 0.6 to 1.2 and at nozzle pressure ratios up to 12.0.

Capone, F. J.↗

Techniques utilized in the simulated altitude testing of a 2D-CD vectoring and reversing nozzle

Simulated altitude testing of a two-dimensional, convergent-divergent, thrust vectoring and reversing exhaust nozzle was accomplished. An important objective of this test was to develop test hardware and techniques to properly operate a vectoring and reversing nozzle within the confines of an altitude test facility. This report presents detailed information on the major test support systems utilized, the operational performance of the systems and the problems encountered, and test equipment improvements recommended for future tests. The most challenging support systems included the multi-axis thrust measurement system, vectored and reverse exhaust gas collection systems, and infrared temperature measurement systems used to evaluate and monitor the nozzle. The feasibility of testing a vectoring and reversing nozzle of this type in an altitude chamber was successfully demonstrated. Supporting systems performed as required. During reverser operation, engine exhaust gases were successfully captured and turned downstream. However, a small amount of exhaust gas spilled out the collector ducts' inlet openings when the reverser was opened more than 60 percent. The spillage did not affect engine or nozzle performance. The three infrared systems which viewed the nozzle through the exhaust collection system worked remarkably well considering the harsh environment.

Block, H. Bruce↗

Boundary layer development as a function of chamber pressure in the NASA Lewis 1030:1 area ratio rocket nozzle

Through the use of theoretical predictions of fluid properties and experimental heat transfer and thrust measurements, the zones of laminar, transitional, and turbulent boundary layer flow were defined for the NASA Lewis 1030:1 area ratio rocket nozzle. Tests were performed on the nozzle at chamber pressures from 350 to 100 psia. For these conditions, the throat diameter Reynolds numbers varied from 300,000 to 1 million. The propellants used were gaseous hydrogen and gaseous oxygen. Thrust measurements and nozzle outer wall temperature measurements were taken during the 3-sec test runs. Comparison of experimental heat transfer and thrust data with the corresponding predictions from the Two-Dimensional Kinetics (TDK) nozzle analysis program indicated laminar flow in the nozzle at a throat diameter Reynolds number of 320,000 or chamber pressure of 360 psia. Comparison of experimental and predicted heat transfer data indicated transitional flow up to and including a chamber pressure of 1000 psia. Predicted values of the axisymmetric acceleration parameter within the convergent and divergent nozzle were consistent with the above results. Based upon an extrapolation of the heat transfer data and predicted distributions of the axisymmetric acceleration parameter, transitional flow was predicted up to a throat diameter Reynolds number of 220,000 or 2600-psia chamber pressure. Above 2600-psia chamber pressure, fully developed turbulent flow was predicted.

Smith, Tamara A.↗

Navier-Stokes predictions of multifunction nozzle flows

A two-dimensional, Navier-Stokes code developed by Imlay based on the implicit, finite-volume method of MacCormack has been applied to the prediction of the flow fields and performance of several nonaxisymmetric, convergent-divergent nozzles with and without thrust vectoring. Comparisons of predictions with experiment show that the Navier-Stokes code can accurately predict both the flow fields and performance for nonaxisymmetric nozzles where the flow is predominantly two-dimensional and at nozzle pressure ratios at or above the design values. Discrepancies between predictions and experiment are noted at lower nozzle pressure ratios where separation typically occurs in portions of the nozzle. The overall trends versus parameters such as nozzle pressure ratio, flap angle, and vector angle were generally predicted correctly.

Wilmoth, Richard G.↗

A static investigation of a simultaneous pitch and yaw thrust vectoring 2-D C-D nozzle

An investigation has been conducted in the static test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance and flow-turning capability of a two-dimensional convergent-divergent nozzle. Thrust vectoring in the pitch plane was provided by rotation of the divergent flaps. The exhaust stream was turned in the yaw direction by deflection of yaw flaps hinged at the end of the nozzle sidewalls. The yaw flap hinge location was varied along the divergent region of the nozzle at four locations including the exit plane and the throat plane. The three hinge locations upstream of the nozzle exit plane required the downstream corners of both upper and lower divergent flaps to be cut off to eliminate interference when the yaw flaps were deflected. Three different lengths of yaw flaps were tested at several angles of deflection. The nozzle simulated a dry power setting with an expansion ratio typical of subsonic cruise and was tested at nozzle pressure ratios from 2.0 to 7.0.

Taylor, John G.↗

Boundary layer development as a function of chamber pressure in the NASA Lewis 1030:1 area ratio rocket nozzle

Through the use of theoretical predictions of fluid properties and experimental heat transfer and thrust measurements, the zones of laminar, transitional, and turbulent boundary layer flow were defined for the NASA Lewis 1039:1 area ratio rocket nozzle. Tests were performed on the nozzle at chamber pressures from 350 to 100 psia. For these conditions, the throat diameter Reynolds numbers varied from 300,000 to 1 million. The propellants used were gaseous hydrogen and gaseous oxygen. Thrust measurements and nozzle outer wall temperature measurements were taken during the 3-sec test runs. Comparison of experimental heat transfer and thrust data with the corresponding predictions from the Two-Dimensional Kinetics (TDK) nozzle analysis program indicated laminar flow in the nozzle at a throat diameter Reynolds number of 320,000 or chamber pressure of 360 psia. Comparison of experimental and predicted heat transfer data indicated transitional flow up to and including a chamber pressure of 1000 psia. Predicted values of the axisymmetric acceleration parameter within the convergent and divergent nozzle were consistent with the above results. Based upon an extrapolation of the heat transfer data and predicted distributions of the axisymmetric acceleration parameter, transitional flow was predicted up to a throat diameter Reynolds number of 220,000 or 2600-psia chamber pressure. Above 2600-psia chamber pressure, fully developed turbulent flow was predicted.

Smith, Tamara A.↗

Experimental results for a two-dimensional supersonic inlet used as a thrust deflecting nozzle

Nearly all supersonic V/STOL aircraft concepts are dependent on the thrust deflecting capability of a nozzle. In one unique concept, referred to as the reverse flow dual fan, not only is there a thrust deflecting nozzle for the fan and core engine exit flow, but because of the way the propulsion system operates during vertical takeoff and landing, the supersonic inlet is also used as a thrust deflecting nozzle. This paper presents results of an experimental study to evaluate the performance of a supersonic inlet used as a thrust deflecting nozzle for this reverse flow dual fan concept. Results are presented in terms of nozzle thrust coefficient and thrust vector angle for a number of inlet/nozzle configurations. Flow visualization and nozzle exit flow survey results are also shown.

Johns, Albert L.↗

The effect of test-cell pressure on resistojet nozzle flow

Previous experimental work has shown that measured resistojet thrust decreases from that obtained at hard vacuum conditions as the test-cell pressure rises above 0.001 torr. Thrust losses have been observed for both cold and heated flow conditions, and the most significant losses have been experienced using thrusters with low Reynolds number flow and high area ratio nozzles. In order to further investigate nozzle flow characteristics, a pressure probe having four degrees of freedom has been used to obtain stagnation pressure surveys across the nozzle exit planes of four resistojets. The surveys show a change in the ratio of the supersonic core to the viscous boundary layer flow areas as the test-cell pressure increases. The surveys are also used for detecting whether an oblique shock is present in an overexpanded nozzle flow. Thruster temperature measurements and nozzle exit plane pressure surveys indicate that thrust losses are the combined result of convection heat losses and nozzle flow momentum effects.

Penko, Paul F.↗

Cold Flow Determination of the Internal Flow Environment Around the Submerged TVC Nozzle for the Space Shuttle SRM

A series of subscale cold flow tests was performed to quantify the gas flow characteristics at the aft end of the Space Shuttle Solid Rocket Motor. This information was used to support the analyses of the redesigned nozzle/case joint. A portion of the thermal loads at the joint are due to the circumferential velocities and pressure gradients caused primarily by the gimbaling of the submerged nose TVC nozzle. When the nozzle centerline is vectored with respect to the motor centerline, asymmetries are set up in the flow field under the submerged nozzle and immediately adjacent to the nozzle/case joint. Specific program objectives included: determination of the effects of nozzle gimbal angle and propellant geometry on the circumferential flow field; measurement of the static pressure and gas velocities in the vicinity of the nozzle/case joint; use of scaling laws to apply the subscale cold flow data to the full scale SRM; and generation of data for use in validation of 3-D computational fluid dynamic, CFD, models of the SRM flow field. These tests were conducted in the NASA Marshall Space Flight Center Airflow Facility with a 7.5 percent scale model of the aft segment of the SRM. Static and dynamic pressures were measured in the model to quantify the flow field. Oil flow data was also acquired to obtain qualitative visual descriptions of the flow field. Nozzle gimbal angles of 0, 3.5, and 7 deg were used with propellant grain configurations corresponding to motor burn times of 0, 9, 19, and 114 seconds. This experimental program was successful in generating velocity and pressure gradient data for the flow field around the submerged nose nozzle of the Space Shuttle SRM at various burn times and gimbal angles. The nature of the flow field adjacent to the nozzle/case joint was determined with oil droplet streaks, and the velocity and pressure gradients were quantified with pitot probes and wall static pressure measurements. The data was applied to the full scale SRM thru a scaling analysis and the results compared well with the 3-D computational fluid dynamics computer model.

Whitesides, R. H.↗

Advanced Mach 3.5 Axisymmetric Quiet Nozzle

To advance boundary-layer stability and transition research and to ultimately provide reliable predictions of transition for supersonic flight vehicles, a wind tunnel is required with very low stream disturbance levels comparable to free flight conditions. Experimental and theoretical research to develop a low-disturbance supersonic wind tunnel has achieved a breakthrough. A new concept for nozzle design is presented which promises a large increase in the length of the quiet test core. The Advanced Mach 3.5 Axisymmetric Quiet Nozzle is the first prototype built to prove the new design concept. Experimental results from this new nozzle on the extent of laminar wall boundary layers are compared with data from other nozzles and with theoretical predictions based on linear stability theory. The Reynolds numbers based on the measured length of the quiet test core for this new nozzle are in excellent agreement with the theoretical predictions. The effect of surface finish on the nozzle performance is also discussed.

Chen, Fang-Jenq↗

Experimental evaluation of expendable supersonic nozzle concepts

Exhaust nozzles for expendable supersonic turbojet engine missile propulsion systems are required to be simple, short and compact, in addition to having good broad-range thrust-minus-drag performance. A series of convergent-divergent nozzle scale model configurations were designed and wind tunnel tested for a wide range of free stream Mach numbers and nozzle pressure ratios. The models included fixed geometry and simple variable exit area concepts. The experimental and analytical results show that the fixed geometry configurations tested have inferior off-design thrust-minus-drag performance in the transonic Mach range. A simple variable exit area configuration called the Axi-Quad nozzle, combining features of both axisymmetric and two-dimensional convergent-divergent nozzles, performed well over a broad range of operating conditions. Analytical predictions of the flow pattern as well as overall performance of the nozzles, using a fully viscous, compressible CFD code, compared very well with the test data.

Baker, V.↗

Static internal performance of an axisymmetric nozzle with multiaxis thrust-vectoring capability

An investigation was conducted in the static test facility of the Langley 16 Foot Transonic Tunnel in order to determine the internal performance characteristics of a multiaxis thrust vectoring axisymmetric nozzle. Thrust vectoring for this nozzle was achieved by deflection of only the divergent section of this nozzle. The effects of nozzle power setting and divergent flap length were studied at nozzle deflection angles of 0 to 30 at nozzle pressure ratios up to 8.0.

Carson, George T., Jr.↗

A parametric experimental investigation of a scramjet nozzle at Mach 6 with Freon and argon or air used for exhaust simulation

A parametric experimental investigation of a scramjet nozzle was conducted with a gas mixture used to simulate the scramjet engine exhaust flow at a free-stream Reynolds number of approximately 6.5 x 10(exp 6) per foot. External nozzle surface angles of 16, 20, and 24 deg were tested with a fixed-length ramp and for cowl internal surface angles of 6 and 12 deg. Pressure data on the external nozzle surface were obtained for mixtures of Freon and argon gases with a ratio of specific heats of about 1.23, which matches that of a scramjet exhaust. Forces and moments were determined by integration of the pressure data. Two nozzle configurations were also tested with air used to simulate the exhaust flow. On the external nozzle surface, lift and thrust forces for air exhaust simulation were approximately half of those for Freon-argon exhaust simulation and the pitching moment was approximately a third. These differences were primarily due to the difference in the ratios of specific heats between the two exhaust simulation gases. A 20 deg external surface angle produced the greatest thrust for a 6 deg cowl internal surface angle. A flow fence significantly increased lift and thrust forces over those for the nozzle without a flow fence.

Cubbage, James M.↗

Static thrust-vectoring performance of nonaxisymmetric convergent-divergent nozzles with post-exit yaw vanes

A static (wind-off) test was conducted in the Static Test Facility of the 16-ft transonic tunnel to determine the performance and turning effectiveness of post-exit yaw vanes installed on two-dimensional convergent-divergent nozzles. One nozzle design that was previously tested was used as a baseline, simulating dry power and afterburning power nozzles at both 0 and 20 degree pitch vectoring conditions. Vanes were installed on these four nozzle configurations to study the effects of vane deflection angle, longitudinal and lateral location, size, and camber. All vanes were hinged at the nozzle sidewall exit, and in addition, some were also hinged at the vane quarter chord (double-hinged). The vane concepts tested generally produced yaw thrust vectoring angles much less than the geometric vane angles, for (up to 8 percent) resultant thrust losses. When the nozzles were pitch vectored, yawing effectiveness decreased as the vanes were moved downstream. Thrust penalties and yawing effectiveness both decreased rapidly as the vanes were moved outboard (laterally). Vane length and height changes increased yawing effectiveness and thrust ratio losses, while using vane camber, and double-hinged vanes increased resultant yaw angles by 50 to 100 percent.

Foley, Robert J.↗

Scale model test results of several STOVL ventral nozzle concepts

Short take-off and vertical landing (STOVL) ventral nozzle concepts are investigated by means of a static cold flow scale model at a NASA facility. The internal aerodynamic performance characteristics of the cruise, transition, and vertical lift modes are considered for four ventral nozzle types. The nozzle configurations examined include those with: butterfly-type inner doors and vectoring exit vanes; circumferential inner doors and thrust vectoring vanes; a three-port segmented version with circumferential inner doors; and a two-port segmented version with cylindrical nozzle exit shells. During the testing, internal and external pressure is measured, and the thrust and flow coefficients and resultant vector angles are obtained. The inner door used for ventral nozzle flow control is found to affect performance negatively during the initial phase of transition. The best thrust performance is demonstrated by the two-port segmented ventral nozzle due to the elimination of the inner door.

Meyer, B. E.↗

Design of thrust vectoring exhaust nozzles for real-time applications using neural networks

Thrust vectoring continues to be an important issue in military aircraft system designs. A recently developed concept of vectoring aircraft thrust makes use of flexible exhaust nozzles. Subtle modifications in the nozzle wall contours produce a non-uniform flow field containing a complex pattern of shock and expansion waves. The end result, due to the asymmetric velocity and pressure distributions, is vectored thrust. Specification of the nozzle contours required for a desired thrust vector angle (an inverse design problem) has been achieved with genetic algorithms. This approach is computationally intensive and prevents the nozzles from being designed in real-time, which is necessary for an operational aircraft system. An investigation was conducted into using genetic algorithms to train a neural network in an attempt to obtain, in real-time, two-dimensional nozzle contours. Results show that genetic algorithm trained neural networks provide a viable, real-time alternative for designing thrust vectoring nozzles contours. Thrust vector angles up to 20 deg were obtained within an average error of 0.0914 deg. The error surfaces encountered were highly degenerate and thus the robustness of genetic algorithms was well suited for minimizing global errors.

Prasanth, Ravi K.↗

Hydrogen no-vent fill testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗