Search NASA⌕ Search

SEARCH · Search NASA

Results for “passivation layer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A comparison between active and passive sensing of soil moisture from vegetated terrains

A comparison between active and passive sensing of soil moisture over vegetated areas is studied via scattering models. In active sensing three contributing terms to radar backscattering can be identified: (1) the ground surface scatter term; (2) the volume scatter term representing scattering from the vegetation layer; and (3) the surface volume scatter term accounting for scattering from both surface and volume. In emission three sources of contribution can also be identified: (1) surface emission; (2) upward volume emission from the vegetation layer; and (3) downward volume emission scattered upward by the ground surface. As ground moisture increases, terms (1) and (3) increase due to increase in permittivity in the active case. However, in passive sensing, term (1) decreases but term (3) increases for the same reason. This self conpensating effect produces a loss in sensitivity to change in ground moisture. Furthermore, emission from vegetation may be larger than that from the ground. Hence, the presence of vegetation layer causes a much greater loss of sensitivity to passive than active sensing of soil moisture.

Fung, A. K.↗

A comparison between active and passive sensing of soil moisture from vegetated terrains

A comparison between active and passive sensing of soil moisture over vegetated areas is studied via scattering models. In active sensing three contributing terms to radar backscattering can be identified: (1) the ground surface scatter term; (2) the volume scatter term representing scattering from the vegetation layer; and (3) the surface volume scatter term accounting for scattering from both surface and volume. In emission three sources of contribution can also be identified: (1) surface emission; (2) upward volume emission from the vegetation layer; and (3) downward volume emission scattered upward by the ground surface. As ground moisture increases, terms (1) and (3) increase due to increase in permittivity in the active case. However, in passive sensing, term (1) decreases but term (3) increases for the same reason. This self compensating effect produces a loss in sensitivity to change in ground moisture. Furthermore, emission from vegetation may be larger than that from the ground. Hence, the presence of vegetation layer causes a much greater loss of sensitivity to passive than active sensing of soil moisture.

Fung, A. K.↗

N/P GaAs concentrator solar cells with an improved grid and bushbar contact design

The major requirements for a solar cell used in space applications are high efficiency at AMO irradiance and resistance to high energy radiation. Gallium arsenide, with a band gap of 1.43 eV, is one of the most efficient sunlight to electricity converters (25%) when the the simple diode model is used to calculate efficiencies at AMO irradiance, GaAs solar cells are more radiation resistant than silicon solar cells and the N/P GaAs device has been reported to be more radiation resistant than similar P/N solar cells. This higher resistance is probably due to the fact that only 37% of the current is generated in the top N layer of the N/P cell compared to 69% in the top layer of a P/N solar cell. This top layer of the cell is most affected by radiation. It has also been theoretically calculated that the optimized N/P device will prove to have a higher efficiency than a similar P/N device. The use of a GaP window layer on a GaAs solar cell will avoid many of the inherent problems normally associated with a GaAlAs window while still proving good passivation of the GaAs surface. An optimized circular grid design for solar cell concentrators has been shown which incorporates a multi-layer metallization scheme. This multi-layer design allows for a greater current carrying capacity for a unit area of shading, which results in a better output efficiency.

Desalvo, G. C.↗

Investigation of Contact Properties and Device Performance for Bifacial Double-Side Textured Silicon Solar Cells With Polysilicon Based Passivating Contacts

We investigate the impact of the surface morphology on the contact properties of phosphorus doped poly-Si layers. If the poly-Si layer on a textured surface remains intact after high-temperature metallization using a fire-through (FT) silver (Ag) paste, the J0,metal is not expected to increase significantly while the specific contact resistivity can improve with a textured surface. The contact properties of the FT Ag contacts to n+ poly-Si deposited on both textured and planar surfaces are investigated by measuring and evaluating ρc and J0,metal. The reasons for differences in contact resistance and recombination are further investigated with SEM imaging. Solar cells with n-type polysilicon based passivating contacts on the rear side are fabricated and characterized. The scientific approach used, and the insights presented in this work, help to understand the mechanisms and behavior of screen-printed and fired-through contacts to polysilicon layers deposited onto textured silicon surfaces.

Padhamnath, Pradeep (ORCID:0000000202510624)↗

Assessment of Resistance of Bacillus Horneckiae Endospores to UV Radiation and Function of Their Extraneous Layer in Resistance

Spore-forming microbes are highly resistant to various physical and chemical conditions, which include ionizing and UV radiation, desiccation and oxidative stress, and the harsh environment of outer space or planetary surfaces. The spore's resistance might be due to their metabolically dormant state, and/or by the presence of a series of protective structures that encase the interior-most compartment, the core, which houses the spore chromosome. These spores have multiple layers surrounding the cell that are not found in vegetative cells, and some species have an outer layer of proteins and glycoproteins termed the "exosporium" or a fibrous "extraneous layer" (EL). Bacillus horneckiae is an EL-producing novel sporeformer isolated from a Phoenix spacecraft assembly clean room, and it has previously demonstrated resistance to UV radiation up to 1000 J/m(sup 2). The EL appears to bind B. horneckiae spores into large aggregations, or biofilms, and may confer some UV resistance to the spores. Multiple culturing and purification schemes were tried to achieve high purity spores because vegetative cells would skew UV resistance results. An ethanol-based purification scheme produced high purity spores. Selective removal of the EL from spores was attempted with two schemes: a chemical extraction method and physical extraction (sonication). Results from survival rates in the presence and absence of the external layer will provide a new understanding of the role of biofilms and passive resistance that may favor survival of biological systems in aggressive extra-terrestrial environments. The chemical extraction method decreased viable counts of spores and lead to an inconclusive change UV resistance relative to non-extracted spores. The physical extraction method lead to non-aggregated spores and did not alter viability; however, it produced UV resistance profiles similar to non-extracted spores. In addition to the EL-removal study, samples of B. horneckiae spores dried on aluminum coupons and exposed to increasing UV (200-400 nm range) levels (0 to 8.0 x 105 kJ/m(sup 2)) were tested for viability, which indicated that the maximum UV exposure level that still resulted in viable spores was 5.0 x 10? kJ/m(sup 2).

resistance↗

A Sample of What We Have Learned from A-Train Cloud Measurements

The A-train active sensors CloudSat and CALIPSO provide detailed information about cloud vertical structure. Coarse vertical information can also be obtained from a combination of passive sensors (e.g. cloud liquid water content from AMSR-E, cloud ice properties from MLS and HIRDLS, cloud-top pressure from MODIS and AIRS, and UVNISINear IR absorption and scattering from OMI, MODIS, and POLDER). In addition, the wide swaths of instruments such as MODIS, AIRS, OMI, POLDER, and AMSR-E can be exploited to create estimates of the three-dimensional cloud extent. We will show how data fusion from A-train sensors can be used, e.g., to detect and map the presence of multiple layer/phase clouds. Ultimately, combined cloud information from Atrain instruments will allow for estimates of heating and radiative flux at the surface as well as UV/VIS/Near IR trace-gas absorption at the overpass time on a near-global daily basis. CloudSat has also dramatically improved our interpretation of visible and UV passive measurements in complex cloudy situations such as deep convection and multiple cloud layers. This has led to new approaches for unique and accurate constituent retrievals from A-train instruments. For example, ozone mixing ratios inside tropical deep convective clouds have recently been estimated using the Aura Ozone Monitoring Instrument (OMI). Field campaign data from TC4 provide additional information about the spatial variability and origin of trace-gases inside convective clouds. We will highlight some of the new applications of remote sensing in cloudy conditions that have been enabled by the synergy between the A-train active and passive sensors.

Joiner, Joanna↗

Assessing the Impact of Soil Layer Depth Specification on the Observability of Modeled Soil Moisture and Brightness Temperature

The utility of hydrologic land surface models (LSMs) can be enhanced by using information from observational platforms, but mismatches between the two are common.This study assesses the degree to which model agreement with observations (observability) is affected by two mechanisms in particular: 1) physical incongruities between the support volumes being characterized and 2) inadequateor inconsistent parameterizations of physical processes. The Noah and Noah-MP LSMs by default characterize surface soil moisture (SSM) in the top 10 cm of the soil column. This depth may be reasonable when comparing against soil moisture from in situ probes centered at 5 cm,but it is notably different from the 5 cm (or less) sensing depth of NASA’s Soil Moisture Active Passive (SMAP) satellite mission. These depth inconsistencies are examined by using thinner model layers in the Noah and Noah-MP LSMs and comparing resultant simulations to in situ and SMAP soil moisture. In addition, a forward radiative transfer model to simulate microwave brightness temperatures (Tbs) is used to facilitate direct comparisons of LSM-based and SMAP-based L-band Tb retrievals. Observability is quantified using Kolmogorov-Smirnov distance values, calculated from empirical cumulative distribution functions of SSM and Tb time series. Experiment results depend on the particular subspace being analyzed (SSM or Tb). This study concludes that therole of increasedsoil layer discretizationon LSM observability is secondary to the influence of component parameterizations, the effects of which dominate systematic differences with observations

SMAP↗

Determining the Shallow Surface Velocity at the Apollo 17 Landing Site

Many studies have been performed to determine the shallow surface velocity model at the Apollo 17 landing site. The Lunar Seismic Profiling Experiment (LSPE) had both an active component with eight explosive packages (EPs) and a passive experiment collecting data at various time intervals. Using the eight EPs, the initial shallow surface velocity model was determined to be 250 m/s in the first layer of depth 248 m, 1200 m/s with a depth of 927 m in the second layer, and 4000 m/s down to a depth of 2 km in the third layer. Have performed variations on this study to produce new velocity models shown. Recent studies have also been reanalyzing the passive LSPE data and have found three different thermal moonquake event types occurring at different times within the lunar day. The current goal of the project is to collocate the thermal moonquakes to physical surface features to determine the breakdown of lunar rocks. However, to locate shallow surface events, an accurate velocity model is needed. Presented a thermal moonquake location algorithm using first order approximation, including surface events only. To improve these approximations, a shallow surface velocity is needed.

Phillips, D.↗

An L-Band Brightness Temperature Disaggregation Method Using S-Band Radiometer Data for the Water Cycle Observation Mission (WCOM)

The Water Cycle Observation Mission (WCOM) will build upon previous L and C band passive microwave soil moisture satellite missions. WCOM will consist of a passive microwave synthetic aperture radiometer operating at L, S, and C bands. The WCOM requirements for passive soil moisture are to estimate soil moisture in the top 5 cm of soil layer with an error less than 0.04 cu m/cu m, at 15 km resolution and with a 3-day revisit. A new set of algorithms for these multi-frequency platforms will need to be developed for estimating the data products at the desired resolution. To accomplish this, a brightness temperature (TB) downscaling methodology is developed that uses passive S-band TB (30 km) to downscale L-band TB (50 km) and to estimate soil moisture at a 30 km resolution, based on the linear relationships between the passive signals of L-band and S-band. To test this downscaling method, analysis was performed using PALS data from the Soil Moisture Experiments in 2002 (SMEX02). For this study, 4 km L-band observations were downscaled to 800 m. The root mean square errors (RMSE) between the downscaled TBL at 800m with the observed TBL at 800m are 2.63 K and 1.60 K for H and V polarizations respectively. The results also showed that it was possible to use these disaggregated TB to estimate soil moisture to meet the mission requirement of 0.04 cu m/cu m. These results showed that we can obtain higher resolution soil moisture from L band passive TB with a high accuracy (<0.04 cu m/cu m) by using S-band information.

Disaggregation↗

Remote measurement of ice thickness on the shuttle external tank surface

A passive technique is proposed for remote measurement of thickness of the ice layer formed on the external tank surface of the Shuttle during the T-2 hours period before launch. It is based on the comparison of the ratios of the intensities of three preselected near-IR wavelength bands scattered from the (test spot) and a neighboring (reference spot) on the tank surface. The Shuttle is uniformly illuminated by a battery of strategically located solar simulator lamps and banks of incadescent lamps during prelaunch period. Thus, there should be adequate radiation in the three selected bands incident on the external tank surface during the test period. It is planned to conduct a feasibility study of the proposed technique before recommending it to the KSC/SSC teams for adoption.

Singh, Jag J.↗

The JPL Phase B interferometer testbed

Future NASA missions with large optical systems will require alignment stability at the nanometer level. However, design studies indicate that vibration resulting from on-board disturbances can cause jitter at levels three to four orders of magnitude greater than this. Feasibility studies have shown that a combination of three distinct control layers will be required for these missions, including disturbance isolation, active and passive structural vibration suppression, and active optical pathlength compensation. The CSI technology challenge is to develop these design and control approaches that can reduce vibrations in the optical train by a factor of 1000 to 10,000. The focus of the paper is on describing the Phase B Testbed structure and facility, as the experimental results are included in other papers presented at this same conference.

Eldred, Daniel B.↗

Numerical Modeling of Flow Control in a Boundary-Layer-Ingesting Offset Inlet Diffuser at Transonic Mach Numbers

This paper will investigate the validation of the NASA developed, Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, for a boundary-layer-ingesting (BLI) offset (S-shaped) inlet in transonic flow with passive and active flow control devices as well as a baseline case. Numerical simulations are compared to wind tunnel results of a BLI inlet experiment conducted at the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel. Comparisons of inlet flow distortion, pressure recovery, and inlet wall pressures are performed. The numerical simulations are compared to the BLI inlet data at a free-stream Mach number of 0.85 and a Reynolds number of approximately 2 million based on the fanface diameter. The numerical simulations with and without tunnel walls are performed, quantifying tunnel wall effects on the BLI inlet flow. A comparison is made between the numerical simulations and the BLI inlet experiment for the baseline and VG vane cases at various inlet mass flow rates. A comparison is also made to a BLI inlet jet configuration for varying actuator mass flow rates at a fixed inlet mass flow rate. Overall, the numerical simulations were able to predict the baseline circumferential flow distortion, DPCP avg, very well within the designed operating range of the BLI inlet. A comparison of the average total pressure recovery showed that the simulations were able to predict the trends but had a negative 0.01 offset when compared to the experimental levels. Numerical simulations of the baseline inlet flow also showed good agreement with the experimental inlet centerline surface pressures. The vane case showed that the CFD predicted the correct trends in the circumferential distortion levels for varying inlet mass flow but had a distortion level that was nearly twice as large as the experiment. Comparison to circumferential distortion measurements for a 15 deg clocked 40 probe rake indicated that the circumferential distortion levels are very sensitive to the symmetry of the flow and that a misalignment of the vanes in the experiment could have resulted in this difference. The numerical simulations of the BLI inlet with jets showed good agreement with the circumferential inlet distortion levels for a range of jet actuator mass flow ratios at a fixed inlet mass flow rate. The CFD simulations for the jet case also predicted an average total pressure recovery offset that was 0.01 lower than the experiment as was seen in the baseline. Comparisons of the flow features for the jet cases revealed that the CFD predicted a much larger vortex at the engine fan-face when compare to the experiment.

Allan, Brian G.↗

Numerical Modeling of Flow Control in a Boundary-Layer-Ingesting Offset Inlet Diffuser at Transonic Mach Numbers

This paper will investigate the validation of a NASA developed, Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, for a boundary-layer-ingesting (BLI) offset (S-shaped) inlet in transonic flow with passive and active flow control devices as well as the baseline case. Numerical simulations are compared to wind tunnel results of a BLI inlet conducted at the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel. Comparisons of inlet flow distortion, pressure recovery, and inlet wall pressures are performed. The numerical simulations are compared to the BLI inlet data at a freestream Mach number of 0.85 and a Reynolds number of approximately 2 million based on the length of the fan-face diameter. The numerical simulations with and without wind tunnel walls are performed, quantifying effects of the tunnel walls on the BLI inlet flow measurements. The wind tunnel test evaluated several different combinations of jet locations and mass flow rates as well as a vortex generator (VG) vane case. The numerical simulations will be performed on a single jet configuration for varying actuator mass flow rates at a fix inlet mass flow condition. Validation of the numerical simulations for the VG vane case will also be performed for varying inlet mass flow rates. Overall, the numerical simulations were able to predict the baseline circumferential flow distortion, DPCPavg, very well for comparisons made within the designed operating range of the BLI inlet. However the CFD simulations did predict a total pressure recovery that was 0.01 lower than the experiment. Numerical simulations of the baseline inlet flow also showed good agreement with the experimental inlet centerline surface pressures. The vane case showed that the CFD predicted the correct trends in the circumferential distortion for varying inlet mass flow but had a distortion level that was nearly twice as large as the experiment. Comparison to circumferential distortion measurements for a 15 deg clocked 40 probe rake indicated that the circumferential distortion levels are very sensitive to the symmetry of the flow and that a miss alignment of the vanes in the experiment could have resulted in this difference. The numerical simulations of the BLI inlet with jets showed good agreement with the circumferential inlet distortion levels for a range of jet actuator mass flow ratios at a fixed inlet mass flow rate. The CFD simulations for the jet case also predicted an average total pressure recovery that was 0.01 lower than the experiment as was seen in the baseline. Comparison of the flow features the jet case revealed that the CFD predicted a much larger vortex at the engine fan-face when compare to the experiment.

Allan Brian G.↗

Optimization, Design, and Demonstration of 1 kW Stirling Controller Using Capacitor-based Power Factor Correction

Free-piston Stirling convertors provide efficient, reliable thermal to electric power conversion, provided they are paired with a reliable controller. This paper outlines work underway on design concepts for kilowatt-class controllers. Using passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is maximized through incorporating wide-bandgap gallium nitride (GaN) switches, and passive PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling controllers.

Christopher Barth↗

Electrochemical quantification of phosphonic acid passivated surface sites of NiO x for perovskite solar cells

Nickel oxide (NiO x ) is among the few p-type metal oxide semiconductors considered a strong candidate for hole transport layers in halide perovskite solar cells (PSCs). However, its reactivity with perovskite ions poses significant challenges to achieving high efficiency and long-term stability. Here, we investigate passivation of detrimental reactive surface sites on NiO x by carbazole phosphonic acids. We leverage electrochemical cyclic voltammetry (CV) of NiO x electrodes as a proxy measure for the redox activity that afflicts PSCs. From the CVs, we derive a metric, N (units cm −2 ), that relates to the number of redox active sites on NiO x surfaces. We observe a statistically significant negative correlation between PSC efficiency and N-value that indicates PSCs are more efficient on NiO x with lower electrochemical reactivity. The new mechanistic insight into NiO x passivation demonstrates it requires a reducing agent and Brønsted acid combination, providing a broadly applicable approach for evaluating and enhancing the stability and performance of NiO x -based interfaces in photovoltaics.

14 SOLAR ENERGY↗

High-Altitude Hydration System

Three methods are being developed for keeping water from freezing during high-altitude climbs so that mountaineers can remain hydrated. Three strategies have been developed. At the time of this reporting two needed to be tested in the field and one was conceptual. The first method is Passive Thermal Control Using Aerogels. This involves mounting the fluid reservoir of the climber s canteen to an inner layer of clothing for better heat retention. For the field test, bottles were mounted to the inner fleece layer of clothing, and then aerogel insulation was placed on the outside of the bottle, and circumferentially around the drink straw. When climbers need to drink, they can pull up the insulated straw from underneath the down suit, take a sip, and then put it back into the relative warmth of the suit. For the field test, a data logger assessed the temperatures of the water reservoir, as well as near the tip of the drink straw. The second method is Passive Thermal Control with Copper-Shielded Drink Straw and Aerogels, also mounted to inner layers of clothing for better heat retention. Braided wire emanates from the inside of the fleece jacket layer, and continues up and around the drink straw in order to use body heat to keep the system-critical drink straw warm enough to keep water in the liquid state. For the field test, a data logger will be used to compare this with the above concept. The third, and still conceptual, method is Active Thermal Control with Microcontroller. If the above methods do not work, microcontrollers and tape heaters have been identified that could keep the drink straw warm even under extremely cold conditions. Power requirements are not yet determined because the thermal environment inside the down suit relative to the external environment has not been established. A data logger will be used to track both the external and internal temperatures of the suit on a summit day.

Parazynski, Scott E.↗

James Webb Space Telescope Core 2 Test - Cryogenic Thermal Balance Test of the Observatorys Core Area Thermal Control Hardware

The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.

JWST Thermal Core 2 Test↗

Radiative Heating Rates Computed With Clouds Derived From Satellite‐Based Passive and Active Sensors and their Effects on Generation of Available Potential Energy

Radiative heating rates computed with cloud properties derived from passive and active sensors are investigated. Zonal monthly radiative heating rate anomalies computed using both active and passive sensors show that larger variability in longwave cooling exists near the tropical tropopause and near the top of the boundary layer between ~50°N to ~50°S. Aerosol variability contributes to increases in shortwave heating rate variability. When zonal monthly mean cloud effects on the radiative heating rate computed with both active and passive sensors and those computed with passive sensor only are compared, the latter shows cooling and heating peaks corresponding to cloud top and base height ranges used for separating cloud types. The difference of these two sets of cloud radiative effect on heating rates in the middle to upper troposphere is larger than the radiative heating rate uncertainty estimated based on the difference of two active sensor radiative heating rate profile data products. In addition, radiative heating rate contribution to generation of eddy available potential energy is also investigated. Although radiation contribution to generation of eddy available potential energy averaged over a year and the entire globe is small, radiation increases the eddy available potential energy in the northern hemisphere during summer. Two key elements that longwave radiation contribute to the generation of eddy potential energy are (1) longitudinal temperature gradient in the atmosphere associated with land and ocean surface temperatures contrasts and absorption of longwave radiation emitted by the surface and (2) cooling near the cloud top of stratocumulus clouds.

Kato, Seiji↗