At least 379 records · Page 21

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient Engine core design and performance report

The Energy Efficient Engine (E3) is a NASA program to develop fuel saving technology for future large transport aircraft engines. Testing of the General Electric E3 core showed that the core component performance and core system performance necessary to meet the program goals can be achieved. The E3 core design and test results are described.

Stearns, E. Marshall↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Energy Efficient Engine: Control system component performance report

An Energy Efficient Engine (E3) program was established to develop technology for improving the energy efficiency of future commercial transport aircraft engines. As part of this program, General Electric designed and tested a new engine. The design, fabrication, bench and engine testing of the Full Authority Digital Electronic Control (FADEC) system used for controlling the E3 Demonstrator Engine is described. The system design was based on many of the proven concepts and component designs used on the General Electric family of engines. One significant difference is the use of the FADEC in place of hydromechanical computation currently used.

Beitler, R. S.↗

Multi-hydrophilic functional network enables porous membranes excellent anti-fouling performance for highly efficient water remediation

Membrane technology is believed as a cost-effective approach for solving the water issues, where as it suffers from serious membrane fouling. Surface grafting and surface coating have been proved to be effective in abating the membrane fouling; however, these processes always need additional procedures and compromise the initial permeance of the membranes. Herein, we developed a kind of highly permeable polyacrylonitrile (PAN) membranes with excellent anti-fouling performance through one-step phase inversion of the PAN casting solution containing water-soluble active additives. During the process, the water-soluble active additives could segregate towards the membrane surface and pore walls; thereby finely tailoring the pore structures of the PAN-based membranes. Moreover, the active additives could react with each other to form crosslinked networks containing multi-hydrophilic functional groups including CH2-O-CH2, -OH or-Si-OH. Consequently, the PAN-based membranes exhibited surprising superhydrophilicity with water contact angle below 10. even after soaking in water for one week and the anti-fouling permeance of the membranes increased significantly with permeance recovery rate above 93%. Interestingly, the modified membranes also demonstrated both high permeances and high separation efficiency, thereby showing strong promise in water environmental remediation including wastewater treatment and oil/water emulsion separation.

Anti-fouling↗

Modeling the performance and faradaic efficiency of solid oxide electrolysis cells using doped barium zirconate perovskite electrolytes

Y-doped BaZrO 3 (BaZr 1 x Y x O 3 δ , or “BZY”), a proton-conducting ceramic featuring high bulk conductivity and good chemical stability, is a promising electrolyte material for solid oxide electrolysis cells. Further doping with Ce and/or Yb (creating materials “BCZY” and “BCZYYb”) can improve conductivity and sintering properties, but at significant penalty to cells’ faradaic efficiency (FE). Studies have proposed that reduction of lattice Ce can occur in the hydrogen electrode, which consumes some hydrogen produced by the hydrogen evolution reaction, leading to decreased FE. Despite studies suggesting this phenomenon, the mechanism is largely unknown. In this work, we developed a multiphysics model to study the transport of multiple defect species and the performance of BZY, BCZY, and BCZYYb, capturing the tradeoff between enhanced performance at the cost of FE for BCZY and BCZYYb electrolytes compared to BZY. We also found that increasing the water content of the anode gas supply lowers the current output of the cell but results in better FE. The model, which uses several parameters previously unavailable in the literature, was validated to experiments varying temperature, steam water content, and electrolyte material, as well as two performance metrics (performance curves and FE). Results verify and explain observed trends, informing future work on Ce-doped BZY electrolytes.

08 HYDROGEN↗

A patterned phase-changing vanadium dioxide film stacking with VO 2 nanoparticle matrix for high performance energy-efficient smart window applications

A vanadium dioxide (VO 2 ) based solid-to-solid phased changing material has been attracting great interest in smart window applications. However, achieving high solar modulation and high transparency simultaneously in visible light is the major challenge for the practical application of this smart material. To resolve this issue, in this paper, a smart film composed of a VO 2 nanoparticle matrix and a patterned VO 2 film is presented. Furthermore, numerical modeling and electromagnetic simulation are carried out to characterize the performance in terms of solar modulation and luminous transmittance, and a parametric study is carried out to optimize the proposed smart window film. Compared with the VO 2 nanoparticle matrix, the proposed structure can obtain 23% solar modulation and 57% luminous transmittance but with a much thinner thickness, which will significantly reduce the cost and fabrication complexity and extend the environment stability.

42 ENGINEERING↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Enhanced hindrance from phenyl outer side chains on nonfullerene acceptor enables unprecedented simultaneous enhancement in organic solar cell performances with 16.7% efficiency

Inner side-chain engineering on Y6 has been a proven successful in improving short-circuit current density (JSC) through fine-tuning aggregated structures of acceptors. However, it fails in tuning the lowest unoccupied molecular orbital level (LUMO) and open-circuit voltage (V OC ). In this paper, we turn to focus on engineering the outer side chains on the flanking thienothiophene units with 4-hexylphenyl (PhC6) and 6-phenylhexyl (C6Ph) chains. Use of PhC6 enhances the steric effect between the attached phenyl and the ending group, which in combination with the additional conjugation effect provided by the linking phenyl leads to upshifted energy levels and increased V OC as a result. Again, substitution with the bulkier PhC6 unprecedentedly improves film-morphology with reduced paracrystalline disorder and long period and increased root-mean-square composition variations as well, leading to increased electron and hole mobilities and suppressed monomolecular recombination with J SC and fill-factor (FF) simultaneously enhanced. The PM6:BTP-PhC6-based devices yield a higher efficiency value of 16.7% than the PM6:BTP-C6Ph-based one (15.5%). Furthermore, this study shows a conceptual advance in materials design towards reducing the conflict between V OC and J SC in binary blended organic solar cells, which can be achieved by introducing bulkier chains to twist the backbone and simultaneously enhance the packing order.

14 SOLAR ENERGY↗

Critical review and future prospects for desiccant coated heat exchangers: Materials, design, and manufacturing

Solid desiccant dehumidification is a promising alternative to vapor compression-based air-dehumidification to reduce energy consumption and improve air quality. Desiccant coated heat exchanger (DCHE), as one type of solid desiccant dehumidification system, can improve system performance and efficiency. The thermal performance and moisture removal capability of the DCHE greatly influence its dehumidification performance.The present work aims to critically analyze the designs, materials, and manufacturing methods of heat exchangers used for solid desiccant coating and look into recent developments in regular heat exchangers, potentially deployed as a substrate for DCHE applications. A comprehensive literature review of publications regarding solid desiccant materials, heat exchangers, manufacturing and coating methods, binder materials, and the performance of heat exchangers has been developed. Alternative heat exchangers are described as better options than fin and tube heat exchangers that have been considered thus far for DCHE applications. Additionally, the heat exchanger's manufacturing process and materials over their thermal and mass exchange performance have been analyzed. Despite the widespread use of fin and tube heat exchangers for solid desiccant coating, recent developments in heat exchanger design, and related fields such as manufacturing methods and materials, open the possibilities for their application in solid desiccant dehumidification systems. Lastly, the authors provide their outlook on possible developments of DCHE technology, aiming to increase systems' energy and dehumidification performance.

36 MATERIALS SCIENCE↗

Deffe: A Data-efficient Framework for Performance Characterization in Domain-Specific Computing

Predicting workload performance is a crucial task for many architecture and system research. In this paper we present De￿e, a framework to estimate the workload performances under varying architectural configurations. The infrastructure component of Deffe is based on scalable and easy-to-use open-source software components. By casting the performance modeling as transfer learning tasks, the modeling component of Deffe can leverage the learned knowledge on one workload, and “transfer” it to a new workload. Extensive experimental results show that the method can achieve superior testing accuracy with an effective reduction of 32-80x in terms of the amount of required training data.

Liu, Frank↗

Analysis of combustion chamber deposit growth on temperature swing thermal barrier coatings in a spark ignition engine

Temperature swing thermal barrier coatings (TBCs) have the potential to improve efficiency and performance through thermal management of the combustion chamber. However, the effects of combustion chamber deposits (CCDs) on the surface of the TBCs are unclear. Therefore, this paper analyzes the impact of CCD formation on a temperature swing TBC. A piston and a heat flux probe coated with a novel material are installed in a single-cylinder research engine at a low-load condition for 62.5 h to promote CCD growth. Every 12.5 h, the performance at a knock limited condition is assessed and thermophysical property measurements on the heat flux probe are performed. Net thermal efficiency increased by 0.4% absolute after 12.5 h relative to the baseline condition, but further CCD growth caused a dithering of efficiency between the 12.5 h and baseline points. The KLSA retarded consistently throughout this period. As a result, external property measurements with the coated heat flux probe showed an improvement in the thermophysical properties of the TBC/CCD layer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and performance of energy efficient propellers for Mach 0.8 cruise

The increased emphasis on fuel conservation in the world has stimulated a series of studies of both conventional and unconventional propulsion systems for commercial aircraft. Preliminary results from these studies indicate that a fuel saving of 14 to 40 percent may be realized by the use of an advanced high-speed turboprop. This turboprop must be capable of high efficiency at Mach 0.8 cruise above 9.144 km altitude if it is to compete with turbofan powered commercial aircraft. Several advanced aerodynamic concepts were investigated in recent wind tunnel tests under NASA sponsorship on two propeller models. These concepts included aerodynamically integrated propeller/nacelles, area ruling, blade sweep, reduced blade thickness and power (disk) loadings several times higher than conventional designs. The aerodynamic design methodology for these models is discussed. In addition, some of the preliminary test results are presented which indicate that propeller net efficiencies near 80 percent were obtained for high disk loading propellers operating at Mach 0.8.

Mikkelson, D. C.↗

Design and performance of energy efficient propellers for Mach 0.8 cruise

It is believed that a fuel saving of 14 to 40 percent may be realized by the use of an advanced high-speed turboprop. This turboprop must be capable of high efficiency at Mach 0.8 cruise above 9.144 km altitude if it is to compete with turbofan powered commercial aircraft. Several advanced aerodynamic concepts were investigated in recent wind tunnel tests under NASA sponsorship on two propeller models. These concepts included aerodynamically integrated propeller/nacelles, area-ruling, blade sweep, reduced blade thickness and power (disk) loadings several times higher than conventional designs. The aerodynamic design methodology for these models is discussed in this paper. In addition, some of the preliminary test results are presented which indicate that propeller net efficiencies near 80 percent were obtained for high disk loading propellers operating at Mach 0.8.

Mikkelson, D. C.↗

Dish Stirling system integration and test progress report

The integration and check-out of a complete Dish Solar Stirling Thermal Power System is described. The preliminary results of the tests conducted thus far are presented. The results are very encouraging and show promise of high performance and efficiency. The outstanding performance and durability of the 4-95 Stirling engine was the highlight of this 6 month integration and test activity. Exposure to severe heat, dust, sand and wind during the summer months and heavy rains, high winds, including sand storms and freezing cold in recent months did affected the engine or the receiver in any noticable manner.

Haglund, R. A.↗