Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

Flexible Vanadium Dioxide Photodetectors for Visible to Longwave Infrared Detection at Room Temperature

Abstract Flexible optoelectronics is a rapidly growing field, with a wide range of potential applications. From wearable sensors to bendable solar cells, curved displays, and curved focal plane arrays, the possibilities are endless. The criticality of flexible photodetectors for many of these applications is acknowledged, however, devices that are demonstrated thus far are limited in their spectral range. In this study, flexible photodetectors are demonstrated using a VO x nanoparticle ink, with an extremely broad operating wavelength range of 0.4 to 20 µm. This ink is synthesized using a simple and scalable wet‐chemical process. These photodetectors operate at room temperature and exhibit minimal variance in performance even when bent at angles of up to 100 ° at a bend radius of 6.4 mm. In addition, rigorous strain testing of 100 bend and release cycles revealed a photoresponse with a standard deviation of only 0.55%. This combination of mechanical flexibility, wide spectral response, and ease of fabrication makes these devices highly desirable for a wide range of applications, including low‐cost wearable sensors and hyperspectral imaging systems.

36 MATERIALS SCIENCE↗

Multispectral Quantitative Phase Imaging Using a Diffractive Optical Network

As a label‐free imaging technique, quantitative phase imaging (QPI) provides optical path length information of transparent specimens for various applications in biology, materials science, and engineering. Multispectral QPI measures quantitative phase information across multiple spectral bands, permitting the examination of wavelength‐specific phase and dispersion characteristics of samples. Herein, the design of a diffractive processor is presented that can all‐optically perform multispectral quantitative phase imaging of transparent phase‐only objects within a snapshot. The design utilizes spatially engineered diffractive layers, optimized through deep learning, to encode the phase profile of the input object at a predetermined set of wavelengths into spatial intensity variations at the output plane, allowing multispectral QPI using a monochrome focal plane array. Through numerical simulations, diffractive multispectral processors are demonstrated to simultaneously perform quantitative phase imaging at 9 and 16 target spectral bands in the visible spectrum. The generalization of these diffractive processor designs is validated through numerical tests on unseen objects, including thin Pap smear images. Due to its all‐optical processing capability using passive dielectric diffractive materials, this diffractive multispectral QPI processor offers a compact and power‐efficient solution for high‐throughput quantitative phase microscopy and spectroscopy.

36 MATERIALS SCIENCE↗

Book Review: Reiner Salzer and Heinz W. Siesler (Eds.): Infrared and Raman spectroscopic imaging, 2nd ed.

This second edition of "Infrared and Raman Spectroscopic Imaging" propels practitioners in that wide-ranging field, as well as other readers, to the current state of the art in a well-produced and full-color, completely revised and updated, volume. This new edition chronicles the expanded application of vibrational spectroscopic imaging from yesterday's time-consuming point-by-point buildup of a hyperspectral image cube, through the improvements afforded by the addition of focal plane arrays and line scan imaging, to methods applicable beyond the diffraction limit, instructs the reader on the improved instrumentation and image and data analysis methods, and expounds on their application to fundamental biomedical knowledge, food and agricultural surveys, materials science, process and quality control, and many others.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design and Performance of the Antenna-Coupled Lumped-Element Kinetic Inductance Detector

Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments (e.g. CMB-S4) will require a substantial increase in the number of detectors compared to current instruments. Arrays of kinetic inductance detectors (KIDs) provide a possible path to realising such large-format arrays owing to their intrinsic multiplexing advantage and relative cryogenic simplicity. In this paper, we report on the design of a variant of the traditional KID design: the antenna-coupled lumped-element KID. A polarisation-sensitive twin-slot antenna placed behind an optimised hemispherical lens couples power onto a thin-film superconducting microstrip line. The power is then guided into the inductive section of an aluminium KID, where it is absorbed and modifies both the resonant frequency and quality factor of the KID. We present the various aspects of the design and preliminary results from the first set of seven-element prototype arrays and compare to the expected modelled performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A relative radiometric correction method for airborne SWIR hyperspectral image using the side-slither technique

Stripe noise still remains in airborne short-wave infrared (SWIR) hyperspectral (HS) images after laboratory calibration due to the stray light of HS imager, nonlinear response of infrared focal plane array, and the distinct difference of equivalent color temperature between the integrating sphere and the sun. It is difficult to get a sun-like radiation source, and we apply the side-slither technique for relative radiometric correction of HS images. The calibration data corresponding to different irradiance were obtained by the side-slither technique of imager. Then, the two-point multi-section method is used for relative radiometric correction of HS images. This paper presents the principle, the experimental results, and the analysis of the proposed method. To validate the effectiveness of this method, it was compared with other methods and evaluated by quantitative quality indices. The results reveal that this method has a good performance in relative radiometric correction of HS image and is superior to the laboratory calibration based on integrating sphere. Consequently, the proposed method can successfully eliminate the adverse effect caused by the difference of equivalent color temperature between radiation sources, and also can improve the accuracy of HS applications such as absolute radiation correction and target recognition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Function reconsideration of indium bump in InSb IRFPAs

Indium bumps are generally accepted to possess functions of electrical connection, mechanical support and heat transfer in flip-chip devices. After comparing the distribution of stress components along different paths in InSb infrared focal plane arrays (IRFPAs), we ascertain that local enhancement effects of the stress components are remarkable in regions where the indium bumps are. More specifically, the local enhanced tensile stress in InSb chip connected with the indium bumps can lead to the local fracture of the InSb chip, and the locally enhanced shear and peeling stresses may give rise to the local interfacial delamination between the InSb chip and the indium bumps. These inferences are confirmed by the observed local failure characteristics, such as the distribution of the local delamination, the distribution of the crack widths, and the distribution of the cracks. In addition, the simulated Z-component strain distribution in InSb IRFPAs is also consistent with the backside surface profile of the InAs/GaSb IRFPAs fabricated in America with the identical structure, that is, the InSb chip glued with the indium bumps is concave downward, and the InSb chip glued with the underfill is convex upward. Judging from all these confirmed simulation results, we are confident that the indium bumps play a pivotal role in inducing the local failure of InSb IRFPAs. So the role of the indium bumps in causing the local failure of InSb IRFPAs needs to be supplemented and emphasized to comprehensively evaluate the structural reliability of InSb IRFPAs.

42 ENGINEERING↗

Methanol Partial Oxidation on MoO 3 /SiO 2 Catalysts: Application of Vibrational Spectroscopic Imaging Techniques in a High Throughput Operando Reactor

A novel prototype high throughput operando (OHT) reactor designed and built for catalyst screening and characterization is presented in this article. For the first time, this OHT reactor integrates Fourier Transformation infrared (FT-IR) imaging technique and Raman spectroscopy in operando conditions. Using a focal plane array (HgCdTe FPA, 128x128 pixels, and 1,675 Hz frame rate) detector for the FT-IR imaging system, we are able to simultaneously follow the catalyst activity and selectivity of all parallel reaction channels. Each set of image data has 16, 384 IR spectra with a spectral range of 900-4000 cm-1 in an 8 cm-1 resolution. It only takes 2-20 second, depending on signal to noise ratio, to collect a full image of all reaction channels. Results on reactant conversion and product selectivity are obtained from FT-IR spectral analysis. Six home-designed Raman probes, one for each reaction channel, are used for simultaneous collection of Raman spectra of all catalysts and possible reaction intermediates on the catalyst surface under real reaction environment. As a model system, methanol partial oxidation reaction on silica supported molybdenum oxide (MoO 3 /SiO 2 ) catalysts under different reaction conditions has been studied to show the performance of the OHT reactor.

10 SYNTHETIC FUELS↗

Innovative FT-IR Imaging of Protein Film Secondary Structure Before and After Heat Treatment

Changes in the secondary structure of globular protein occur during thermal processing. An infrared reflecting mirrored optical substrate that is unaffected by heat allows recording infrared spectra of protein films in a reflection absorption mode on the stage of an FT-IR microspectrometer. Hydrated films of myoglobin protein cast from solution on the mirrored substrate are interrogated before and after thermal denaturation to allow a direct comparison. Focal plane array imaging of 280 protein films allowed selection of the same area in the image from which to extract spectra. After treatment, 110 of 140 spectra from multiple films showed a dramatic shift from the {alpha}-helix form (1650 {+-} 5 cm{sup -1}) to aggregated forms on either side of the original band. Seventy maxima were near 1625 cm{sup -1}, and 40 shifted in the direction of 1670 cm{sup -1}. The method developed was applied to films cast from two other commercial animal and plant protein sources.

59 BASIC BIOLOGICAL SCIENCES↗

Origami silicon optoelectronics for hemispherical electronic eye systems

Digital image sensors in hemispherical geometries offer unique imaging advantages over their planar counterparts, such as wide field of view and low aberrations. Deforming miniature semiconductor-based sensors with high-spatial resolution into such format is challenging. Here we introduce a simple origami approach for fabricating single-crystalline silicon-based focal plane arrays and artificial compound eyes that have hemisphere-like structures. Convex isogonal polyhedral concepts allow certain combinations of polygons to fold into spherical formats. Using each polygon block as a sensor pixel, the silicon-based devices are shaped into maps of truncated icosahedron and fabricated on flexible sheets and further folded either into a concave or convex hemisphere. These two electronic eye prototypes represent simple and low-cost methods as well as flexible optimization parameters in terms of pixel density and design. Results demonstrated in this work combined with miniature size and simplicity of the design establish practical technology for integration with conventional electronic devices.

42 ENGINEERING↗

Cross-Scale Molecular Analysis of Chemical Heterogeneity in Shale Rocks

The organic and mineralogical heterogeneity in shale at micrometer and nanometer spatial scales contributes to the quality of gas reserves, gas flow mechanisms and gas production. Here, we demonstrate two molecular imaging approaches based on infrared spectroscopy to obtain mineral and kerogen information at these mesoscale spatial resolutions in large-sized shale rock samples. The first method is a modified microscopic attenuated total reflectance measurement that utilizes a large germanium hemisphere combined with a focal plane array detector to rapidly capture chemical images of shale rock surfaces spanning hundreds of micrometers with micrometer spatial resolution. The second method, synchrotron infrared nano-spectroscopy, utilizes a metallic atomic force microscope tip to obtain chemical images of micrometer dimensions but with nanometer spatial resolution. This chemically "deconvoluted" imaging at the nano-pore scale is then used to build a machine learning model to generate a molecular distribution map across scales with a spatial span of 1000 times, which enables high-throughput geochemical characterization in greater details across the nano-pore and micro-grain scales and allows us to identify co-localization of mineral phases with chemically distinct organics and even with gas phase sorbents. Finally, this characterization is fundamental to understand mineral and organic compositions affecting the behavior of shales.

04 OIL SHALES AND TAR SANDS↗

Assessment of the chemical changes induced in human melanoma cells by boric acid treatment using infrared imaging

Boron is found in everyday foods and drinking water in trace quantities. Boron exists as boric acid (BA) within plants and animals, where low levels have been linked to cancer incidence. However, this correlation is not well characterized. In this study, we examined the chemical and morphological effects of BA on human skin melanoma cells (SK-MEL28) using Fourier Transform InfraRed Imaging (FTIRI) with a Focal Plane Array (FPA) detector. Cells were grown under concentrations of BA ranging from 0 to 50 mM. Cell viability was determined after 1, 2, 3, 5, 7 and 10 days using trypan blue staining. With FTIRI, images of approximately twenty cells per time point per condition were collected. Principal components analysis (PCA) was used to evaluate changes in cell composition, with particular focus on the lipid, protein, and nucleic acid spectral components. Results from trypan blue staining revealed decreased cell viability as BA concentration increased. FTIRI data indicated that the protein and lipid contents (as indicated by the lipid/protein ratio) did not undergo substantial changes due to BA treatment. In contrast, the nucleic acid/protein ratio significantly decreased with BA treatment. PCA results showed an increase in {beta}-sheet protein at higher concentrations of BA (12.5, 25, and 50 mM). Together, these results suggest that high concentrations of BA have an anti-proliferative effect and show signs consistent with apoptosis.

59 BASIC BIOLOGICAL SCIENCES↗

High Throughput Operando Studies using Fourier Transform Infrared Imaging and Raman Spectroscopy

A prototype operando high throughput (OHT) reactor designed and built for catalyst screening and characterization combines Fourier transform infrared (FT-IR) imaging and Raman spectroscopy in operando conditions. Using a focal plane array (FPA) detector (HgCdTe FPA, 128×128 pixels, and 1,610 Hz frame rate) for the FT-IR imaging system, the catalyst activity and selectivity of all parallel reaction channels can be simultaneously followed. Each image dataset possesses16,384 IR spectra with a spectral range of 800 to 4000 cm-1 with an 8 cm-1 resolution. Depending on the signal-to-noise ratio, 2 to 20 seconds are needed to generate a full image of all reaction channels from a dataset. Results on reactant conversion and product selectivity are obtained from FT-IR spectral analysis. Six novel Raman probes, one for each reaction channel, were specially designed and house built at Pacific Northwest National Laboratory (PNNL), to simultaneously collect Raman spectra of the catalysts and possible reaction intermediates on the catalyst surface under operando conditions. As a model system, methanol partial oxidation reaction on silica-supported molybdenum oxide (MoO3/SiO2) catalysts has been studied under different reaction conditions to demonstrate the performance of the OHT reactor.

10 SYNTHETIC FUELS↗

Super-resolution with the Help of Active Camera

In a digital optical imaging system, image resolution is constrained by several factors, including focus plane array pitch and optics. Super-resolution approaches aim at overcoming some of these limits by incorporating additional information of the object and/or combining several pictures of the same object, taken with sub-pixel displacements between each other. As shown by some authors, the obtainable zoom factor using the second approach has an upper limit, determined by the signal-to-noise ratio of the image taken. Moreover, as discussed later in this paper, lines at some pitch are indistinguishable, further lowering this limit. Here, an approach to overcome this using active camera and employing images of different relative scales is introduced. The choice of these scales is commented. The results from two experiments, using simulated and real set-up are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small high cooling power space cooler

The small High Efficiency pulse tube Cooler (HEC) cooler, that has been produced and flown on a number of space infrared instruments, was originally designed to provide cooling of 10 W @ 95 K. It achieved its goal with >50% margin when limited by the 180 W output ac power of its flight electronics. It has also been produced in 2 stage configurations, typically for simultaneously cooling of focal planes to temperatures as low as 35 K and optics at higher temperatures. The need for even higher cooling power in such a low mass cryocooler is motivated by the advent of large focal plane arrays. With the current availability at NGAS of much larger power cryocooler flight electronics, reliable long term operation in space with much larger cooling powers is now possible with the flight proven 4 kg HEC mechanical cooler. Even though the single stage cooler design can be re-qualified for those larger input powers without design change, we redesigned both the linear and coaxial version passive pulse tube cold heads to re-optimize them for high power cooling at temperatures above 130 K while rejecting heat to 300 K. Small changes to the regenerator packing, the re-optimization of the tuned inertance and no change to the compressor resulted in the increased performance at 150 K. The cooler operating at 290 W input power achieves 35 W@ 150 K corresponding to a specific cooling power at 150 K of 8.25 W/W and a very high specific power of 72.5 W/Kg. At these powers the cooler still maintains large stroke, thermal and current margins. In this paper we will present the measured data and the changes to this flight proven cooler that were made to achieve this increased performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis, testing, and operation of the MAGI thermal control system

The Aerospace Corporation has completed the development of the Mineral and Gas Identifier (MAGI) sensor - an airborne multi-spectral infrared instrument that is designed to discriminate surface composition and to detect gas emissions from the environment. Sensor performance was demonstrated in a series of flights aboard a Twin Otter aircraft in December 2011 as a stepping stone to a future satellite sensor design. To meet sensor performance requirements the thermal control system was designed to operate the HgCdTe focal plane array (FPA) at 50 K with a 1.79 W heat rejection load to a 44.7 K sink and the optical assembly at 100 K with a 7.5 W heat load to a 82.3 K sink. Two commercial off-theshelf (COTS) Sunpower Stirling cryocoolers were used to meet the instrument’s cooling requirements. A thermal model constructed in Thermal Desktop was used to run parametric studies that guided the mechanical design and sized the two cryocoolers. This paper discusses the development, validation, and operation of the MAGI thermal control system. Detailed energy balances and temperature predictions are presented for various test cases to demonstrate the utility and accuracy of the thermal model. Model inputs included measured values of heat lift as a function of input power and cold tip temperature for the two cryocoolers. These measurements were also used to make predictions of the cool-down behavior from ambient conditions. Advanced heater software was developed to meet unique requirements for both sensor cool-down rate and stability at the set point temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave magnetic dynamics in highly conducting magnetic nanostructures

We performed low-noise broadband microstrip ferromagnetic resonance (FMR) measurements of the resonant modes of an array of metallic ferromagnetic nanostripes. In addition to a strong signal of the fundamental mode, we observed up to five weak-amplitude peaks in the field-resolved FMR traces, depending on the frequency. These higher-order absorption peaks have been theoretically identified as due to resonant excitation of odd and even standing spin waves across the direction of confinement in array plane (i.e., across the stripe width). The theory we developed suggests that the odd modes become excited in the spatially uniform microwave field of the FMR setup due to the large conductivity of metals. This promotes excitation of large-amplitude eddy currents in the sample by the incident microwave magnetic field and ultimately results in excitation of these modes. Following this theory, we found that the eddy current contribution is present only for patterned materials and when the microwave magnetic field is incident on one surface of sample surface, as it is in the case of a microstrip FMR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗