Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Vertically oriented metamaterial broadband linear polariser

Control and manipulation of polarization is an important topic for imaging and light matter interactions. In the infrared regime, the large wavelengths make wire grid polarizers a viable option, as it is possible to create periodic arrays of metallic wires at that scale. The recent advent of metamaterials has spurred an increase in non-traditional polarizer motifs centred around more complicated repeat units, which potentially provide more functionality. In this paper we explore the use of two-dimensional (2D) arrays of single and back-to-back vertically oriented cross dipoles arranged in a cubic in-plane silicon matrix. Here, we show that both single and back-to-back versions have higher rejection ratios and larger bandwidths than either wire grid polarizers or 2D arrays of linear dipoles.

36 MATERIALS SCIENCE↗

Sensor array and apparatus for simultaneous observation of tissue electrophysiology, contractility, and growth

A sensor array for simultaneously measuring electrophysiological responses and contractility responses of a tissue includes: a substrate; a multi-electrode array (MEA) disposed in or on the substrate; and a plurality of interdigitized electrodes (IDEs) disposed in or on the substrate. The MEA and the IDEs are interpenetrating within a plane substantially parallel to an upper surface of the substrate. Systems for measuring such responses using the sensor array may also include contacts and/or connectors for interfacing with external control devices, electrodes, and cell culture components such as a chamber and lid. Fabrication techniques for making such systems include: forming a sensor array comprising an interpenetrating arrangement of IDEs and electrodes of a MEA in or on a substrate surface; forming a plurality of contacts for interfacing the system with one or more external devices in or on the substrate surface; and forming leads between the plurality of contacts and the sensor array.

Qian, Fang↗

Self-consistent solution of the Frank–Bilby equation for interfaces containing disconnections

The quantized Frank–Bilby equation can be used to identify interfacial line defect array configurations which relax the misorientation and/or misfit of a coherent crystalline interface. These line defect arrays may be comprised of dislocations and/or disconnections, which are interfacial steps with dislocation character. When an interface contains disconnections, solution of the quantized Frank–Bilby equation is complicated by the fact that the habit plane orientation is not known in advance because it depends on the unknown spacing of the disconnection array. We present a root-finding-based method for addressing this issue, enabling a self-consistent solution for arbitrary defect content. Our method has been implemented in an open-source code which enumerates all possible solutions given a list of candidate line defects. Two cases are presented employing the code: a misoriented FCC twin boundary and an FCC/BCC phase boundary with the Nishiyama-Wasserman orientation relationship. Both cases exhibit more than 10,000 solutions to the Frank–Bilby equation, with several hundred solutions categorized as ‘‘low energy’’ and thus plausible configurations for the actual interface. The resulting set of solutions can be utilized to predict and understand the properties of a given interface.

42 ENGINEERING↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗

Negative real parts of the equivalent permittivity, permeability, and refractive index of sculptured-nanorod arrays of silver

Thin films comprising parallel nanorods were deposited by directing silver vapor obliquely toward a plane substrate. The direction of the vapor flux was varied in two different ways to sculpture the nanorods in different shapes. The reflection and transmission coefficients of the thin films were measured at three wavelengths in the visible regime for normal-illumination conditions for two linear-polarization states, using walk-off interferometry and polarization interferometry. The authors found that sculpturing significantly affects the signs of the real parts of the equivalent permittivity, permeability, and refractive index of the silver thin films for the two polarization states at different wavelengths. Thus, vapor deposition combined with sculpturing can be useful for large-scale production of materials having different equivalent constitutive parameters with negative real parts.

36 MATERIALS SCIENCE↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Engineering Symmetry-Breaking Nanocrescent Arrays for Nanolasing

This paper describes a symmetry-breaking plasmonic lattice structure that can support narrow resonances as optical feedback for nanolasing. A scalable technique is developed to fabricate nanocrescent arrays with low-structural symmetry unit cells to achieve in-plane quadrupolar lattice plasmon modes. These lattice plasmons with extremely narrow linewidths preserve nonzero net dipole moments under normal excitation. Ultrafast band-edge lasing can be switched on and off by changing the polarization of the incident pump light. In conclusion, the quadrupolar lattice plasmon lasing process is simulated with a semi-quantum model and the sharp tips on the nanocrescents accelerate the lasing buildup process and enhance stimulated emission.

36 MATERIALS SCIENCE↗

The Simons Observatory: Design, Optimization, and Performance of Low-Frequency Detectors

The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment located in the Atacama Desert in Chile that will make precise temperature and polarization measurements over six spectral bands ranging from 27 to 285 GHz. Three small aperture telescopes (SATs) and one large aperture telescope (LAT) will house ~60,000 detectors and cover angular scales between one arcminute and tens of degrees. We present the performance of the dichroic, low-frequency (LF) lenslet-coupled sinuous antenna transition-edge sensor (TES) bolometer arrays with bands centered at 27 and 39 GHz. The LF focal plane will primarily characterize Galactic synchrotron emission as a critical part of foreground subtraction from CMB data. We will discuss the design, optimization, and current testing status of these pixels.

79 ASTRONOMY AND ASTROPHYSICS↗

3D RECONNECTION AND FLOW DYNAMICS IN THE SSX EXPERIMENT

Several new experimental results are reported from plasma merging studies at the Swarthmore Spheromak Experiment (SSX) with relevance to collisionless three-dimensional magnetic reconnection in laboratory and space plasmas. First, recent high-resolution velocity measurements of impurity ions using ion Doppler spectroscopy (IDS) show bi-directional outflow jets at 40 km/s (nearly the Alfven speed). The SSX IDS instrument measures with 1 mus or better time resolution the width and Doppler shift of the C{sub III} impurity (H plasma) 229.7 nm line to determine the temperature and line-averaged flow velocity during spheromak merging events. High flow speeds are corroborated using an in situ Mach probe. Second, ion heating to nearly 10{sup 6} K is observed after reconnection events in a low-density kinetic regime. Transient electron heating is inferred from bursts on a 4-channel soft x-ray array as well as vacuum ultraviolet spectroscopy. Third, the out-of-plane magnetic field and the in-plane Lorentz force in a reconnection volume both show a quadrupolar structure at the ion inertial scale (c/omega{sub pi}). Time resolved vector magnetic field measurements on a 3D lattice B(r, t)) enables this measurement. Earlier work at SSX has shown that formation of three-dimensional structure at the ion inertial scale is temporally and spatially correlated with the observation of superthermal, super-Alfvenic ions accelerated along the X-line normal to the local 2D plane of reconnection. Each of these measurements will be related to and compared with similar observations in a solar or space context. Keywords: spheromak, flow, heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variability of structural and electronic properties of bulk and monolayer Si 2 Te 3

Silicon telluride has diverse properties for potential applications in Si-based devices ranging from fully integrated thermoelectrics to optoelectronics to chemical sensors. This material has a unique layered structure: it has a hexagonal closed-packed Te sublattice, with Si dimers occupying octahedral intercalation sites. Here, we report a theoretical study of this material in both bulk and monolayer form, unveiling an array of diverse properties arising from reorientations of the silicon dimers between planes of Te atoms. The band gap varies up to 30% depending on dimer orientations. The variation of dimer orientations gives rise to thermal contraction, arising from more dimers aligning out of the plane as the material is heated. Here, strain also affects the dimer orientations and provides a degree of control of the materials properties, making Si 2 Te 3 a promising candidate for nanoscale mechanical, optical, and memristive devices.

36 MATERIALS SCIENCE↗

Strip Velocity Measurements for Gated X-Ray Imagers Using Short Pulse Lasers

Strip velocity measurements of gated X-ray imagers are presented using an ultra-short pulse laser. Obtaining time-resolved X-ray images of inertial confinement fusion shots presents a difficult challenge. One diagnostic developed to address this challenge is the gated X-ray imagers. The gated X-ray detectors (GXDs) developed by Lawrence Livermore National Laboratory and Los Alamos National Laboratory use a microchannel plate (MCP) coated with a gold strip line, which serves as a photocathode. GXDs are used with an array of pinholes, which image onto various parts of the GXD image plane. As the pulse sweeps over the strip lines, it creates a time history of the event with consecutive images. In order to accurately interpret the timing of the images obtained using the GXDs, it is necessary to measure the propagation of the pulse over the strip line. The strip velocity was measured using a short pulse laser with a pulse duration of approximately 1-2 ps. The 200nm light from the laser is used to illuminate the GXD MCP. The laser pulse is split and a retroreflective mirror is used to delay one of the legs. By adjusting the distance to the mirror, one leg is temporally delayed compared to the reference leg. The retroreflective setup is calibrated using a streak camera with a 1 ns full sweep. Resolution of 0.5 mm is accomplished to achieve a temporal resolution of ~5 ps on the GXD strip line.

detectors, x-ray, short pulse lasers↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

Spreading devices into a 2-D module layout

An apparatus, method, and system, the apparatus including a receiving member dimensioned to receive an array of microelectronic devices; and a linkage member coupled to the receiving member, the linkage member configured to move the receiving member in at least two dimensions so as to modify a spacing between the electronic devices within the array of microelectronic devices received by the receiving member. The method including coupling an array of microelectronic devices to an expansion assembly; and expanding the expansion assembly so as to expand the array of microelectronic devices in at least two directions within a single plane. The system including a support member; an expansion assembly coupled to the support member, the expansion assembly having a plurality of receiving members configured to move in at least two dimensions within a single plane; and a plurality of microelectronic devices coupled to each of the plurality of receiving members.

36 MATERIALS SCIENCE↗

Plasmonic Surface Lattice Resonances: Theory and Computation

In overview, plasmonic surface lattice resonances (Plasmonic SLRs) are mixed light-matter states emergent in a system of periodically arranged metallic nanoparticles (NPs) under the constraint that the array spacing is approximately equal to an integer multiple of the wavelength of optical frequency light divided by the index of refraction of the surrounding medium. The properties of SLRs derive from two separate physical effects; the electromagnetic (plasmonic) response of metal NPs, and the electromagnetic states (photonic cavity modes) associated with the array of NPs. Metal NPs, especially free electron metals such as silver, gold, aluminum and alkali metals, support optical-frequency electron density oscillations known as localized surface plasmons (LSPs). The high density of conduction-band electrons for these metals gives rise to plasmon excitations that strongly couple to light even for particles that are several orders of magnitude smaller than the wavelength of the excitation source. In this sense, LSPs have the remarkable ability to squeeze far-field light into intensely-localized near-electric-fields that can enhance the intensity of light by factors of ~ 10 3 or more. Moreover, due to advances in the synthesis and fabrication of NPs, the intrinsic dependence of LSPs on NP geometry, composition, and size can readily be exploited to design NPs with a wide range of optical properties. One drawback in using LSPs to enhance optical, electronic, or chemical processes is the losses introduced into the system by via dephasing and Ohmic damping - an effect which must either be tolerated or mitigated. Plasmonic SLRs enable the mitigation of loss effects through the coupling of LSPs to diffractive states that arise from arrays satisfying Bragg scattering conditions, also known as Rayleigh anomalies (RAs). Bragg modes are well known for arrays of dielectric NPs, where they funnel and trap incoming light into the plane of the lattice, defining a photonic cavity. The low losses and narrow linewidths associated with dielectric NPs produce Bragg modes that oscillate for ~ 10 3 - 10 4 cycles before decaying. These modes are of great interest to the meta-materials community but have relatively weak electric fields associated with dielectric NPs, and therefore are not used for applications where local field enhancements are needed. Plasmonic lattices, i.e., photonic crystals composed of metallic NPs, combine the characteristics from both LSPs and diffractive states, enabling both enhanced local fields and narrow linewidth excitations, in many respects providing the best advantages of both materials. Thus, by controlling the periodicity and global symmetry of the lattice, in addition to the material composition and shape of the constituent NPs, SLRs can be designed to simultaneously survive for up to 10 3 cycles while maintaining the electric field enhancements near the NP surface that have made the use of LSPs ubiquitous in nanoscience. Modern fabrication methods allow for cm 2 -scale patches of two-dimensional (2D) arrays that are composed of approximately one trillion NPs, making them effectively infinite at the nanoscale. Because of these advances, it is now possible to experimentally realize SLRs with properties that approach those predicted by idealized theoretical models. In this Account, we introduce the fundamental theory of both SLRs and SLR-mediated lasing, where the latter is one of the most important applications of plasmonic SLRs that has emerged to date. The focus of this article is on theoretical concepts for describing plasmonic SLRs and computational methods used for their study, but throughout we emphasize physical insights provided by the theory that aid in making applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dose-to-water conversion for the backscatter-shielded EPID: A frame-based method to correct for EPID energy response to MLC transmitted radiation

Purpose: To develop a frame-by-frame correction for the energy response of amorphous silicon electronic portal imaging devices (a-Si EPIDs) to radiation that has transmitted through the multileaf collimator (MLC) and to integrate this correction into the backscatter shielded EPID (BSS-EPID) dose-to-water conversion model. Methods: Individual EPID frames were acquired using a Varian frame grabber and iTools acquisition software then processed using in-house software developed inMATLAB. For each EPID image frame, the region below the MLC leaves was identified and all pixels in this region were multiplied by a factor of 1.3 to correct for the under-response of the imager to MLC transmitted radiation. The corrected frames were then summed to form a corrected integrated EPID image. This correction was implemented as an initial step in the BSS-EPID dose-to-water conversion model which was then used to compute dose planes in a water phantom for 35 IMRT fields. The calculated dose planes, with and without the proposed MLC transmission correction, were compared to measurements in solid water using a two-dimensional diode array. Results: It was observed that the integration of the MLC transmission correction into the BSS-EPID dose model improved agreement between modeled and measured dose planes. In particular, the MLC correction produced higher pass rates for almost all Head and Neck fields tested, yielding an average pass rate of 99.8% for 2%/2 mm criteria. A two-sample independentt-test and fisher F-test were used to show that the MLC transmission correction resulted in a statistically significant reduction in the mean and the standard deviation of the gamma values, respectively, to give a more accurate and consistent dose-to-water conversion. Conclusions: The frame-by-frame MLC transmission response correction was shown to improve the accuracy and reduce the variability of the BSS-EPID dose-to-water conversion model. The correction may be applied as a preprocessing step in any pretreatment portal dosimetry calculation and has been shown to be beneficial for highly modulated IMRT fields.

60 APPLIED LIFE SCIENCES↗

Radial Two-Dimensional Ion Crystals in a Linear Paul Trap

We experimentally study two-dimensional (2D) Coulomb crystals in the “radial-2D” phase of a linear Paul trap. This phase is identified by a 2D ion lattice aligned entirely with the radial plane and is created by imposing a large ratio of axial to radial trapping potentials. Using arrays of up to 19 171 Yb + ions, we demonstrate that the structural phase boundaries of such crystals are well described by the pseudopotential approximation, despite the time-dependent ion positions driven by intrinsic micromotion. We further observe that micromotion-induced heating of the radial-2D crystal is confined to the radial plane. Finally, we verify that the transverse motional modes, which are used in most ion-trap quantum simulation schemes, are well-predictable numerically and remain decoupled and cold in this geometry. Our results establish radial-2D ion crystals as a robust experimental platform for realizing a variety of theoretical proposals in quantum simulation and computation.

74 ATOMIC AND MOLECULAR PHYSICS↗