Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Outlook for active plasma spectroscopy with entangled two-photon absorption

Entangled two-photon absorption (ETPA) exhibits a quantum-enhanced two-photon absorption cross-section and a linear scaling with incident power that exceeds classical two-photon absorption (TPA) at low photon flux. Here, we assess the feasibility and applications of ETPA for active plasma spectroscopy. The ETPA-absorbed power for an Ar + species in a helicon plasma scenario is calculated to be as high as 0.6 nW cm −1 along the incident beam path for nondegenerate-entangled photon pairs that are near-resonant with an intermediate level. The ETPA absorption power exceeds classical TPA and Bremsstrahlung emission, a necessary condition for a feasible fluorescence measurement. Applications of ETPA plasma spectroscopy may include trace impurity detection, ground-state excitation, and continuous-wave pumping for high-bandwidth turbulence measurements. Possible benefits of plasma measurements are less harm to optical components with lower incident flux and reduced stray light that can contaminate optical diagnostics.

active plasma spectroscopy↗

Integrating fiber optic sensors into metallic components for sensing in harsh environments

The integration of fiber optic sensors into high-temperature materials is critical for real-time monitoring and autonomous operation of engineering systems. This study demonstrated a spark plasma sintering (SPS)-assisted embedding process for integrating sapphire fiber optic sensors into stainless steel components during part fabrication. Optical fibers were encapsulated in stainless steel 316L powders which were sintered at different fabrication conditions using SPS to investigate the effects of sintering parameters on the embedment. Measurements of optical transmittance, combined with microstructural analysis (X-ray computed tomography and scanning electron microscopy) and mechanical testing (tensile and microhardness), were conducted to examine the fiber functionality, fiber–matrix bonding quality, and properties of the sintered materials. Here, the results show that under suitable fabrication conditions, intact optical fibers can be encapsulated in highly-densified (>98 % relative density) stainless steel components. These conditions also led to a good bond at the fiber–matrix interface with micron-sized material interdiffusion across the interface. The sintering parameters were observed to affect fiber optical attenuation, where high temperature, pressure, and hold time during SPS enhanced fiber–matrix bonding and adversely affected optical transmission. Tensile testing confirmed the superior tensile strength and ductility of the matrix fabricated by SPS. Furthermore, the materials exhibited limited strength reduction (~70 MPa) upon the integration of fibers. This study demonstrates the effectiveness of SPS for fiber-material integration for high-temperature applications.

36 MATERIALS SCIENCE↗

Dynamics and energy coupling of gas puff Z-pinches on a fast linear transformer driver

Gas puff Z-pinch experiments with annular Ar and Ne gas shells have been conducted on the Compact Experimental System for Z-pinch and Ablation Research (CESZAR) linear transformer driver (LTD) with 500 kA current and 160 ns rise time. Here, we present results from the first systematic gas puff Z-pinch experiments using a fast (≤ 200 ns) LTD as a driver, in which we show that 7% of the stored energy in the capacitors is coupled to plasma kinetic energy as estimated via self-emission and laser schlieren images. 0D and 1D simulations—which do not allow instability growth and thus reach greater maximum average velocities—using initial conditions inferred from experimental implosion trajectories predict coupling in excess of 10% of the stored energy. Additionally, the Ar and Ne implosions were comparably massed and thus achieved similar maximum kinetic energies, though the Ne pinches were more stable and the x-ray pulses were longer and produced higher yield: 2–5 ns and 0.21–0.52 J (0.15–0.37 J/cm) of Ar K-shell and 12–25 ns and 2.2–3.9 J (1.6–2.6 J/cm) of Ne K-shell, respectively. The difference in stability is most likely attributed to variations in initial conditions such as density distribution and gas breakdown initiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density evolution after shock release from laser-driven polystyrene (CH) targets in inertial confinement fusion

The evolution of the plasma density in the rarefaction wave formed after a laser-driven shock is released from a CH foil was measured using optical interferometry. Here, it was found that the plasma density profile is very sensitive to the conditions at the back surface of the foil before the shock release. Dedicated experiments demonstrated that radiation preheat by coronal x-rays caused early expansion of the back surface and faster expansion of the rarefaction wave. Radiation-hydrodynamics simulations with accurate modeling of radiation preheat from the plasma corona are in good agreement with the experimental results. The early expansion of material interfaces due to coronal x-ray preheat must be evaluated in designing and interpreting laser-driven inertial confinement fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak

The optics system of the Electron Cyclotron Emission Imaging (ECEI) diagnostics on the DIII-D tokamak has been developed and installed for high-resolution temperature fluctuations measurement in the previous decade. The System-on-Chip approach upgrade was finished in June 2019 with high integrated receiver array with 20 individual modules. In this paper, we design new optics with high-level integration. In the new optics system, there will be two mirrors from plasma to receiver array, including one replaceable curved mirror out of the vacuum and one fixed curved mirror in the vessel. There are two options with 1:1 and 1:2 magnifications for high poloidal resolution and larger poloidal window modes. Overall, the new optics system has multiple improvements, including lighter weight, smaller size, more flexible installation and alignment. The synthetic ECEI module is used to evaluate the new optics system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Space-Time Structured Plasma Waves

Electrostatic waves play a critical role in nearly every branch of plasma physics from fusion to advanced accelerators, to astro, solar, and ionospheric physics. The properties of planar electrostatic waves are fully determined by the plasma conditions, such as density, temperature, ionization state, or details of the distribution functions. Furthermore we demonstrate that electrostatic wave packets structured with space-time correlations can have properties that are independent of the plasma conditions. For instance, an appropriately structured electrostatic wave packet can travel at any group velocity, even backward with respect to its phase fronts, while maintaining a localized energy density. These linear, propagation-invariant wave packets can be constructed with or without orbital angular momentum by superposing natural modes of the plasma and can be ponderomotively excited by space-time structured laser pulses like the flying focus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of interface materials on side permeation in indirect encapsulation of organic electronics

This work demonstrates the impact of the contact interface between barrier films and adhesives on the side permeation of moisture into packaged devices. When barrier films are brought into contact with the adhesive layer during indirect encapsulation, permeation along defects at this interface can occur due to the imperfect nature of contact, resulting in the formation of pores. The connected network of pores can act as capillaries and be an alternative pathway for water permeation as opposed to the bulk of the adhesive or edge seal materials used for barrier attachment to the package. The rate of water permeation through the capillaries is governed by surface energies of the materials at the interfaces. Experimental results demonstrate that the rate of water permeation is significantly lowered by using materials with higher contact angles at the interface.

36 MATERIALS SCIENCE↗

Optical spectroscopic tools for standoff uranium detection

Rapid and standoff analysis of uranium is important for many applications. We present the recent advances in standoff detection of uranium using emission and laser-induced fluorescence spectroscopy in conjunction with ultrafast laser filament ablation-based solid sampling.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Broadband sum-frequency generation of spectrally incoherent pulses

We study and demonstrate the nonlinear frequency conversion of broadband optical pulses from 1053 nm to 351 nm using sum-frequency generation with a narrowband pulse at 526.5 nm. The combination of angular dispersion and noncollinearity cancels out the wave-vector mismatch and its frequency derivative, yielding an order-of-magnitude increase in spectral acceptance compared to conventional tripling. This scheme can support the nonlinear frequency conversion of broadband spectrally incoherent nanosecond pulses generated by high-energy lasers and optical parametric amplifiers to mitigate laser−plasma instabilities occurring during interaction with a target. The experimental results obtained with KDP crystals are in excellent agreement with modeling, demonstrating the generation of spectrally incoherent pulses with a bandwidth larger than 10 THz at 351 nm.

47 OTHER INSTRUMENTATION↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗