Search NASA⌕ Search

SEARCH · Search NASA

Results for “power generation dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

An Improved Genetic Algorithm approach to the Unit Commitment/Economic Dispatch problem

The deployment of new technologies, the importance of accurately modeling the dynamics of the generating units and the introduction of new policies are making the solution of the Unit Commitment/Economic Dispatch problem more and more complicated.In the present scenario, traditionally followed scheduling criteria might not lead to the optimal fleet configuration any more. In addition, most of the widely used techniques have limited capabilities at modeling the nonlinear dynamics of committed power plants. When realistic power systems comprising of several tens of generating units are modeled, the resulting optimization problem turns to be computationally intensive for the current computing capabilities. In this paper, an improved version of a GA-based optimization algorithm is presented. A detailed methodology aimed at obtaining a more efficient version of the GA, and a more detailed and accurate description of the flexible operation flexibility of the power plants is described.

genetic algorithm↗

Integrated Canada-U.S. Power Sector Modeling with the Regional Energy Deployment System (ReEDS)

The electric power system in North America is linked between the United States and Canada. Canada has historically been a net exporter of electricity to the United States. The extent to which this remains true will depend on the future evolution of power markets, technology deployment, and policies. To evaluate these and related questions, we modify the Regional Energy Deployment System (ReEDS) model to include an explicit representation of the grid-connected power system in Canada to the continental United States. ReEDS is unique among long-term capacity expansion models for its high spatial resolution and statistical treatment of the impact of variable renewable generation on capacity planning and dispatch. These unique traits are extended to new Canadian regions. We present example scenario results using the fully integrated Canada-U.S. version of ReEDS to demonstrate model capabilities. The newly developed, integrated Canada-U.S. ReEDS model can be used to analyze the dynamics of electricity transfers and other grid services between the two countries under different scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Coordinated Power and Energy Management Using Cluster of Microgrids to Improve Grid Availability and Resiliency

A coordinated power and energy management concept for a cluster of microgrids is presented in this paper. Distributed generation and storage resources at the low voltage end of the power distribution grid can be operated together as microgrids. These microgrids can operate in grid-connected mode and in islanded mode, thereby serving the loads within them during loss-of-service from the transmission network. In the proposed coordinated microgrid management scheme, multiple microgrids, operated as a cluster, can be connected using tie reclosers or through auxiliary distribution lines as a retrofit operation, which are activated during transmission system failure, and power generated or energy stored are shared between microgrids with different power demands. The operation can be achieved with no modified power inverter controls, and minimal changes to the supervisory / dispatch control and communications systems. In this paper, the cluster of microgrids presented include solar photovoltaic (PV) plants, battery energy storage systems (BESS) and loads. A demonstration cluster with two microgrids is operated using a real-time hardware-in-loop platform to show power and energy management during transmission system failure.

Essakiappan, Somasundaram↗

Supercapacitor to Provide Ancillary Services With Control Coordination

This paper proposes a dynamic frequency support scheme of a supercapacitor energy storage system (SCESS) in coordination with run-of-the-river-based pumped storage hydropower (PSH) to enhance the short-term frequency stability in a power system that has a high penetration of renewable energy. To achieve this, the proposed coordinated frequency controller (CFC) enables the SCESS and PSH plant to provide the frequency response. The CFC scheme employs a dynamic droop characteristic in parallel with an integral controller and a distribution function. The dynamic droop characteristic determines the power production for frequency regulation employing a variable gain, which varies with the total capacity of the frequency control units and magnitude of the system frequency error with time; the gain increases with the frequency error, and thereby, arresting the frequency nadir at a higher level than in the conventional droop characteristic. In addition, the distribution function dispatches the power from the dynamic droop and integral controller to the control units in proportion to their headrooms; furthermore, the distribution function considers a sudden loss of generation from an SCESS by its operational constraint during the frequency support. Thus, the proposed dynamic frequency support scheme can enhance the short-term frequency stability for a frequency event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Short-Term Solar Forecasting Platform Using a Physics-Based Smart Persistence Model and Data Imputation Method

Electrical energy plays vital role in our socio-economic activity and therefore ensuring the reliability of the electric grid, from the generation, transmission and distribution level is critical. In order to maintain the power system parameter viz., frequency, voltage, etc., optimally, balancing of generation and consumption is very much essential. However, solar energy is infirm power by nature this is due to cloud cover / other local phenomena. Hence, Photovoltaic (PV) power generation brings a significant challenge to the grid operator due to the variability of the solar energy. The complexity of this challenge in terms of planning and dispatch ability of PV resources, aggravates with the high penetration of solar energy into the electric grid. In this setting, reliable solar radiation forecasting models based on accurate and quality input data become essential. In order to develop a suitable model for predicting solar radiation, quality historical / real time measurement is also needed. Under this study NIWE and NREL jointly developed / tested short-term solar forecasting frameworks using a smart persistence and physics-based smart persistence models for intra-hour forecasting of solar radiation (PSPI) and benchmarked 9 different data imputation techniques in 15 Solar Radiation Resource Assessment (SRRA) stations, located at different parts of India. During any measurement campaign, due to various technical reasons, we may miss few observations. However, the missing observation often reduce the performance of any forecasting model. Therefore, suitable data imputation method would assist us to obtain continuous observation of solar radiation. A station-by-station and method-by-method analysis was carried out to understand the performance of each model. Based on our analysis, among all the data imputation methods, the Kalman data imputation method is better for Indian Weather condition. In addition, Kalman StructTS, Linear, Stine and Arima methods yield slightly inferior accuracy compared to Kalman, but outperform the other methods. The extended solar radiation data are used by solar forecasting models to provide the prediction of solar radiation at 15 SRRA stations. As far as short term forecasting model is concerned, the PSPI model outperforms the Smart Persistence model. However, the forecast error is increases with the forecasting horizon.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

India 2030 Wind and Solar Integration Study (Interim Report)

India has established several targets for renewable energy capacity growth in the coming years, most notably the target of deploying 175 gigawatts (GW) of generation capacity from wind, solar, biomass, and small hydropower by 2022, and furthering that vision with India's Nationally Determined Contribution target of 40% renewable electricity capacity (including hydro) by 2030 (GOI 2015). Given the rapid and significant changes to India's power system to help meet these targets, the objective of this interim report is to understand the operational challenges for India's power grid in 2030. The primary contribution of this report is to establish a 2030 unit commitment and dispatch model of India's grid, with hourly temporal resolution, high spatial resolution of renewable energy resources, interstate transmission constraints, and unit-level generator characteristics. Annual simulations of 2030 operations demonstrate that a 22% annual penetration of wind and solar is manageable by India's grid. Most days in the year do not show signs of stress, and 99.97% of energy is served with the plans as presented. Average coal plant load factors are 70% for the year, up from relatively low plant load factors in recent years (Patel 2018). However, the results highlight specific challenges the grid may face during a small number of high-demand periods, resulting in unserved energy. The drivers behind the unserved energy suggest that this could be avoided with better coordination in scheduling. This report is part of a broader set of analyses under the Energy Transitions Commission (ETC), which includes collaborations with The Energy and Resources Institute (TERI), Climate Policy Initiative (CPI), and a broad stakeholder community.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic Adaptive Droop Control in Frequency Regulation of Power Systems With Intermittent Generators

Modern power systems (MPSs), including microgrids (MGs), are increasingly incorporating multiple renewable energy sources (RESs) such as wind and solar power, as well as battery storage and controllable loads. While environmentally beneficial, these sources pose challenges for control and management due to their intermittent and stochastic nature, especially in maintaining frequency stability with multiple interconnected generators of varying capacities. Traditional droop control methods are effective in systems with generators that are dispatchable and have fixed generation capacities, but they fall short when applied to systems with RESs, where generation capacities are dynamic and affected by unpredictable environmental conditions. To address these challenges, this paper introduces a novel stochastic adaptive droop control (SADC) method for load frequency control (LFC). The proposed method adapts droop coefficients in real time, based on the measured stochastic data of power generation capacities, enabling more effective frequency regulation in systems with variable and intermittent power generation. Unlike traditional adaptive control methods, which assume constant or slowly-varying system parameters, this approach accounts for stochastic processes by modeling them as Markov chains, enabling robust performance under highly dynamic and unpredictable conditions. The key contributions of this work include the development of real-time droop coefficient adaptation algorithms, derivation of their stability and convergence properties, and the demonstration of the advantages of the method through simulations. Case studies highlight the improved performance of frequency regulation, particularly in addressing the impact of stochastic weather conditions and the benefits of reducing dependence on battery reserves in dealing with intermittency of RESs. Finally, this paper provides a comprehensive analysis of the theoretical foundations of the method, as well as practical implementation insights for future power systems with high penetration of RESs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Availability of and Supply Curves for Low-Cost, Dispatch-Constrained Electricity

Among other changes, variable renewable energy (VRE) - primarily wind and solar photovoltaics - is achieving a growing share of total generation. High VRE penetrations may result in an increased level of curtailment and thus suppress the value of additional VRE. This VRE, that either would not be built due to price suppression or would be curtailed, can be considered a resource that we define as low-cost, dispatch-constrained electricity (LDE). LDE could be used for various applications which value low-cost electricity and can operate at reduced capacity factors. Examples include electrolytic hydrogen production and carbon capture. This report provides initial estimates of the quantity and availability of the potential LDE resource in the U.S. under scenarios with high VRE penetrations. It also provides supply curves that can be used in subsequent analysis of the opportunity to use the LDE. We modeled several scenarios using capacity expansion and production cost models for LDE prices ranging from $\$ $0/MWh to $\$ $30/MWh. These LDE prices, coupled with low renewable energy cost assumptions, resulted in VRE penetrations ranging from 48-66% in 2050. The resulting LDE supplies range from 100 - 300 TWh/yr at a price of $\$ $0/MWh to 3,500 - 4,200 TWh/yr at $\$ $30/MWh. Increasing LDE prices increases wind and photovoltaics deployment; however, other generation technology capacities do not decrease equivalently in our models. Thus, additional generation is available but the capacity of traditional dispatchable generation is only reduced slightly. The available LDE is concentrated in the central and southwest U.S. regions because of their high wind and solar resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Advances in Production Cost Modeling for India Renewable Energy Grid Integration Study

The Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid study uses advanced weather and power system modeling to explore the operational impacts of meeting India's 2022 renewable energy targets and identify actions that may be favorable for integrating high levels of renewable energy into the Indian grid. The study relies primarily on a production cost model that simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. This fact sheet provides a detailed look at each of these models, including their common assumptions and the insights provided by each.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Comparison of Methods for Evaluating Dispatch of Long-Duration Energy Storage in Power Systems Models

Long-duration energy storage (LDES) could play a pivotal role in the transformation of electricity grids with high shares of variable renewable energy (VRE) such as solar and wind. However, the weather-dependent nature of VRE introduces challenges for grid balancing and stability, which LDES - along with short-duration energy storage (SDES) - can help address. However, modeling LDES in production cost models (PCMs) is particularly challenging due to the need for high temporal resolution over extended optimization windows while preserving chronology, which ensures the alignment of energy storage operations with VRE generation over multi-day periods. This report compares traditional dispatch methods with advanced LDES dispatch strategies, such as the extended horizon approach, across different PCM platforms and examines tradeoffs and scalability. The comparison reveals that the traditional 1-day optimization horizon within the PCM leads to inefficient utilization of LDES. In contrast, extending the optimization horizon as much as possible significantly reduces curtailment and improves storage dispatch, especially in renewable-dense systems. There is also promise in using state-of-charge or end volume targets set by an external model, however this requires an additional modeling set and generally increases computational burden. This paper presents a comparison of these various methods in a number of power systems, showing algorithms initially in small test systems and scaling up to large, country-wide simulations. Overall, the research presents the trade-offs of various computational methods and illustrates how LDES may play an essential role in power systems of the future.

14 SOLAR ENERGY↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging concentrating solar power plant dispatchability: A review of the impacts of global market structures and policy

Concentrating solar power (CSP) integrated with thermal energy storage delivers flexible and dispatchable power, which is an increasingly valuable quality as electricity systems integrate growing penetrations of variable renewable energy. Valuing and compensating CSP's dispatchability and flexibility requires electricity market structures and policies that appropriately remunerate generation during high-value portions of the day. In this paper, we review previous analyses of CSP economics and deployment, and we find that continued CSP growth will require valuation mechanisms that appropriately compensate for CSP's flexibility during both plant design and plant operation. We then review market structures that drive CSP operations and dispatch in jurisdictions where CSP is being developed, with perspectives from Spain, Chile, Australia, Morocco, South Africa, the United States, China, and the United Arab Emirates (Dubai). Despite broad agreement that CSP's dispatchability provides value to electricity grids, countries' policies for remunerating and leveraging such dispatchability varies widely. As deployment of CSP and variable renewable energy grows, it will be increasingly important to redesign current integration policies to signal the delivery of CSP's grid services more appropriately.

14 SOLAR ENERGY↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

Tri-Level Linear Programming Model for Automatic Load Shedding Using Spectral Clustering

Traditional load shedding schemes can be inadequate in grids with high renewable penetration, leading to unstable events and unnecessary grid islanding. Although for both manual and automatic operating modes load shedding areas have been predefined by grid operators, they have remained fixed, and may be sub-optimal due to dynamic operating conditions. In this work, a distributed tri-level linear programming model for automatic load shedding to avoid system islanding is presented. Preventing islanding is preferred because it reduces the need for additional load shedding besides the disconnection of transmission lines between islands. This is crucial as maintaining the local generation-demand balance is necessary to preserve frequency stability. Furthermore, uneven distribution of generation resources among islands can lead to increased load shedding, causing economic and reliability challenges. This issue is further compounded in modern power systems heavily dependent on non-dispatchable resources like wind and solar. The upper-level model uses complex power flow measurements to determine the system areas to shed load depending on actual operating conditions using a spectral clustering approach. The mid-level model estimates the area system state, while the lower-level model determines the locations and load values to be shed. The solution is practical and promising for real-world applications.

Baquedano-Aguilar, Mario D.↗

NREL's Resource Planning Model

The Resource Planning Model (RPM) is a capacity expansion model designed for a regional power system, such as a utility service territory, state, or balancing authority. Designed from the ground up to include nodal detail, hourly chronological dispatch, and high spatial resolution for renewable resources, recent work has focused on inclusion of storage and other flexible technologies of interest for future power systems with more variable generation (e.g., wind and solar). This slide deck gives an overview of RPM modeling methods, provides example outputs, and briefly summarizes completed analysis projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); soft open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗