Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototypes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

First Search for Dark Photon Dark Matter with a madmax Prototype

We report the first result from a dark photon dark matter search in the mass range from 78.62 to 83.95 μ eV / c 2 with a dielectric haloscope prototype for (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to detectable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an antenna and successively digitized using a low-noise receiver. No significant signal attributable to dark photons has been observed above the expected background. Assuming unpolarized dark photon dark matter with a local density of ρ χ = 0.3 G eV cm 3 we exclude a dark photon to photon mixing parameter χ > 2.7 × 10 − 12 over the full mass range and χ > 1.1 × 10 − 13 at a mass of 80.57 μ eV / c 2 with a 95% confidence level. This is the first physics result from a prototype and exceeds previous constraints on χ in this mass range by up to almost three orders of magnitude. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributing Power Grid State Estimation on HPC Clusters A System Architecture Prototype

The future power grid is expected to further expand with highly distributed energy sources and smart loads. The increased size and complexity lead to increased burden on existing computational resources in energy control centers. Thus the need to perform real-time assessment on such systems entails efficient means to distribute centralized functions such as state estimation in the power system. In this paper, we present our early prototype of a system architecture that connects distributed state estimators individually running parallel programs to solve non-linear estimation procedure. The prototype consists of a middleware and data processing toolkits that allows data exchange in the distributed state estimation. We build a test case based on the IEEE 118 bus system and partition the state estimation of the whole system model to available HPC clusters. The measurement from the testbed demonstrates the low overhead of our solution.

Distributed architecture↗

Longitudinal Gradient Dipole Magnet Prototype for APS at ANL

We planned an upgrade of the Advanced Photon Source at Argonne National Laboratory (ANL). The main goal of the upgrade is to improve the storage ring performance based on more advanced optics. One of the key magnet system elements is bending dipole magnets having a field strength change along the electron beam path. Moreover, a prototype of one such longitudinal gradient dipole magnet has been designed, built, and measured in a collaborative effort of ANL and Fermilab. Our paper discusses various magnetic design options, the selected magnet design, and the fabrication technology. The prototype magnet has been measured by rotational coils, a stretched wire, and a Hall probe. Measurement results are discussed and compared with simulations.

43 PARTICLE ACCELERATORS↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Mu2e transport solenoid prototype design and manufacturing

The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils to the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.

43 PARTICLE ACCELERATORS↗

Localization of quenches and mechanical disturbances in the Mu2e transport solenoid prototype using acoustic emission technique

Acoustic emission (AE) detection is a noninvasive technique allowing the localization of the mechanical events and quenches in superconducting magnets. Application of the AE technique is especially advantageous in situations where magnet integrity can be jeopardized by the use of voltage taps or inductive pickup coils. As the prototype module of the transport solenoid (TS) for the Mu2e experiment at Fermilab represents such a special case, we have developed a dedicated six-channel AE detection system and accompanying software aimed at localizing mechanical events during the coil cold testing. The AE sensors based on transversely polarized piezoceramic washers combined with cryogenic preamplifiers were mounted at the outer surface of the solenoid aluminum shell, with a 60° angular step around the circumference. Acoustic signals were simultaneously acquired at a rate of 500 kS/s, prefiltered and sorted based on their arrival time. Next, based on the arrival timing, angular and axial coordinates of the AE sources within the magnet structure were calculated. Furthermore, we present AE measurement results obtained during cooldown, spot heater firing, and spontaneous quenching of the Mu2e TS module prototype and discuss their relevance for mechanical stability assessment and quench localization.

43 PARTICLE ACCELERATORS↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Results From a Prototype Combination TPC Cherenkov Detector With GEM Readout

A combined time projection chamber-Cherenkov (TPCC) prototype detector has been developed as part of the detector research and development program for a future electron-ion collider (E!C). The prototype was tested at the Fermilab test beam facility (FTBF) to provide a proof of the principle to demonstrate the ability to measure particle tracks and provide particle identification (P!D) information within a common detector volume. The time projection chamber (TPC) portion consists of a 10 × 10 × 10 cm 3 field cage, which delivers charge from tracks to a quadruple gas electron multiplier (GEM) with zigzag-shaped charge collection anodes. The Cherenkov portion consists of a photosensitive quadruple GEM detector with a Cs! photocathode. As tracks pass through the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the Cs! photocathode. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF 4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, including the position resolution as well as the particle id capabilities of the detector, are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CDP1—A Data Concentrator Prototype for the Deep Underground Neutrino Experiment

The design, power analysis and tests of a first COLDATA Prototype (CDP1) design in 65nm process for the Long Baseline Neutrino Facility (LBNF) and the Deep Underground Neutrino Experiment (DUNE) are presented here. CDP1 is a prototype ASIC, for the COLDATA chip, a data concentrator operated in liquid argon. Furthermore, CDP1 is a test vehicle to qualify most of the analog and digital blocks such as LVDS transmitters and receivers, a 1.28 Gbps serializer, a phase locked loop, I 2 C for slow control, fast command receiver and calibration logic at cryogenic temperature. Finally, the test measurements of these blocks are carried out at room temperature (300K) and at cryogenic temperature (77K). The test measurements presented in this article are in good agreement with the simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Data Acquisition and Slow Control Systems for the Mu2e Experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10 000 over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable with direct searches at either present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system exploits otsdaq as its online Data Acquisition System (DAQ) solution. Furthermore, developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability and provides a multi-user, web-based, interface accessible through a web browser. The read out controllers (ROCs) stream out zero-suppressed data continuously from the detector subsystems to the data transfer controllers (DTCs). The data stream is then read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events which are combined with the data flux coming from a cosmic-ray veto (CRV) system. The detector control system (DCS) has been developed using the experimental physics and industrial control system (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS has been integrated into otsdaq. A prototype of the TDAQ system and the DCS has been built at Fermilab's Feynman Computing Center. In this article, we report on the progress of the integration of this prototype in the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat Testing of a Prototypical SiC Foam-Based Flow Channel Insert

As part of the U.S. ITER test blanket module development effort, several flow channel insert (FCI) concepts using a variety of porous SiC and SiC/SiC composites are being developed. Using porous SiC, prototypes of FCI segments as large as 0.12 m x 0.75 m x 0.015 m were fabricated and heat tested with a maximum {Delta}T of {approx}150 C across the FCI walls. In this paper, we report on two heat tests of the FCI prototypes. The first test used radiative heating of the inside of the FCI along with convective cooling of the outside of the FCI, which resulted in a temperature drop of about {approx}147 C across the FCI wall. The second test involved partial submersion of the FCI structure in liquid PbLi, resulting in an inner wall surface temperature of about 600 C and an outer wall temperature of about 450 C ({Delta}T {approx} 150 C). Detailed thermomechanical analyses of the tests were conducted, and results of the simulations are discussed in the context of actual FCI operating conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

Thermomechanical Stress and Creep-Fatigue Analysis of a High-Temperature Prototype Receiver for Heating Particles

This work presents a three-dimensional (3D) thermomechanical model of a prototype-scale enclosed light trapping solar receiver for heating particles. Results of the thermoelastic model are used to estimate receiver lifetime under maximum flux conditions. A computational fluid dynamics (CFD) model is first developed to predict the temperature fields in a multi-panel assembly under steady operating conditions. Solar flux distributions on the receiver are obtained from the software package SolTrace and applied to the 3D thermal model. The subsequent particle heating is captured through a simplified 1D energy balance. Panel reradiation is considered through a surface-to-surface radiation model and natural convection loss to the surrounding air is captured in a representative fluid domain surrounding the receiver. The resulting temperature fields from the CFD analysis are used as inputs for a thermoelastic mechanical model with representative boundary conditions. With the resultant temperature and stress fields, a creep-fatigue damage and lifetime analysis is performed using the linear damage accumulation (LDA) theory. The Manson-Coffin formula and Larson Miller correlation are used to calculate the fatigue and creep, respectively. A maximum damage (corresponding to a 30-year service life) is defined for design assessment. The model was first developed and verified in detail by comparing with published results in the literature (temperature and stress profiles and distributions, and creep/fatigue damage fractions) for tubular solar receivers with supercritical carbon dioxide as the working fluid. It was then implemented to model a planar-cavity receiver with various design parameters. Specifically, three different design geometries are considered, and the results show that a maximum temperature of approximately 1200 K could be reached for each design with the given incident solar flux, with the main difference being the distribution of these temperatures. Preliminary resulting stresses for the small-scale prototype without design optimization vary from 20 MPa to 250 MPa for each design, with the maximum stresses occurring on the front face and concave geometry on the side of the panel. In future work, the developed methodology shown here will be applied to analyze a full-scale (50-150 MWth) receiver.

concentrated solar power↗

Solid State Streak Camera Prototype Electronic Performance Testing and Characterization

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolved diagnostics for studying events that occur in the nanosecond to microsecond time scales. Although streak cameras are among the most common detectors used within the high energy density physics community, they require frequent calibration and typically lack reproducibility in the fine detail. A solid state device with similar temporal performance characteristics could provide several advantages to current streak camera systems by utilizing discrete spatial resolution set by the sensor diodes. National Security Technologies (NSTec) has built a multi-channel solid state streak camera (SSSC) prototype, in collaboration with Sandia National Laboratories, as part of an ongoing project to develop the technology to a level competitive with analog streak cameras. The device concept and results from electronic testing of our first prototypes will be discussed in this manuscript. These measurements will be used as a base for future SSSC development projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype design and experimental tests of a zoom mirror system for the APS upgrade

Mirror-based zoom optics systems can offer variable focal spot sizes over a wide range, which is essential for coherent nanoprobe beamlines, such as the proposed Atomic beamline in the Advanced Photon Source (APS) upgrade project. The success of the zoom mirror system in the nano-focusing regime requires the development of high-precision deformable mirrors, in-situ surface profilers and wavefront sensors, and advanced feedback control system. A prototype 1-D zoom mirror system consists of two vertical focusing mirrors was designed, assembled, and tested at the APS 1-BM beamline. The system consists of a bender-based mirror with a capacitive-sensorarray-based real-time mirror profiler, a bimorph adaptive mirror, and a grating interferometer for the wavefront monitoring. In this work, we present the design and test results of the prototype system demonstrating its zoom focusing capability.

adaptive optics↗

Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications

A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of the optical fibers relative to the CCD. Profile and depth dose characterization measurements are presented and show that the prototype provides excellent dose measurement reproducibility ({+-}0.8%) in-field and good accuracy ({+-}1.6% maximum deviation) relative to the dose measured with an IC10 ionization chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗