Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resolve the Clear-Sky Continuous Diurnal Cycle of High-Resolution ECOSTRESS Evapotranspiration and Land Surface Temperature

Although numerous evapotranspiration (ET) estimates have been developed from remote sensing measurements, a diurnally resolved product with high spatial resolution (<100 m) is still lacking, which is critically needed for agricultural and ecological monitoring. The ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) provides, for the first time, ET at 70 m resolution with diurnal samplings, enabling a step toward filling this data gap. This study developed the first framework to resolve the full diurnal cycle of ET and Land Surface Temperature (LST) from sporadic ECOSTRESS measurements. We first constructed 70 m diurnal LST utilizing a diurnal temperature cycle (DTC) model that fused ECOSTRESS and Geostationary Operational Environmental Satellite (GOES) LST. Next, we derived 70 m diurnal ET from the diurnally resolved LST, along with ancillary meteorological and reflectance data sets, using the Priestley-Taylor Jet Propulsion Laboratory (PT-JPL) algorithm. This framework was tested in two regions: A relatively homogeneous semiarid grassland landscape (centered at the US-Seg Ameriflux site) and a heterogeneous humid cropland landscape (centered at US-ARM). Our diurnally resolved LST and ET successfully reproduced the spatial patterns in the native ECOSTRESS measurements during overpasses for both landscapes (LST: r > 0.97, RMSE ~2°C; ET: r > 0.99, and RMSE = 1–7 W m -2 ). The constructed time series also well captured the temporal variability of the in situ measurements (especially under clear-sky conditions) at both US-Seg and US-ARM, albeit performance varying with availability and quality of ECOSTRESS samples. This study sets the stage for testing and applying our framework to broader climates, biomes, and landscapes toward eventually generating diurnally resolved 70 m global operational LST/ET products to enhance ecological/agricultural applications.

54 ENVIRONMENTAL SCIENCES↗

Technical Note: Rapid prototyping of 3D grid arrays for image guided therapy quality assurance

Three dimensional grid phantoms offer a number of advantages for measuring imaging related spatial inaccuracies for image guided surgery and radiotherapy. The authors examined the use of rapid prototyping technology for directly fabricating 3D grid phantoms from CAD drawings. We tested three different fabrication process materials, photopolymer jet with acrylic resin (PJ/AR), selective laser sintering with polyamide (SLS/P), and fused deposition modeling with acrylonitrile butadiene styrene (FDM/ABS). The test objects consisted of rectangular arrays of control points formed by the intersections of posts and struts (2 mm rectangular cross section) and spaced 8 mm apart in the x, y, and z directions. The PJ/AR phantom expanded after immersion in water which resulted in permanent warping of the structure. The surface of the FDM/ABS grid exhibited a regular pattern of depressions and ridges from the extrusion process. SLS/P showed the best combination of build accuracy, surface finish, and stability. Based on these findings, a grid phantom for assessing machine-dependent and frame-induced MR spatial distortions was fabricated to be used for quality assurance in stereotactic neurosurgical and radiotherapy procedures. The spatial uniformity of the SLS/P grid control point array was determined by CT imaging (0.6x0.6x0.625 mm{sup 3} resolution) and found suitable for the application, with over 97.5% of the control points located within 0.3 mm of the position specified in CAD drawing and none of the points off by more than 0.4 mm. Rapid prototyping is a flexible and cost effective alternative for development of customized grid phantoms for medical physics quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of multiresolution wavelet feature pyramids for automatic registration of multisensor imagery

The problem of image registration, or the alignment of two or more images representing the same scene or object, has to be addressed in various disciplines that employ digital imaging. In the area of remote sensing, just like in medical imaging or computer vision, it is necessary to design robust, fast, and widely applicable algorithms that would allow automatic registration of images generated by various imaging platforms at the same or different times and that would provide subpixel accuracy. One of the main issues that needs to be addressed when developing a registration algorithm is what type of information should be extracted from the images being registered, to be used in the search for the geometric transformation that best aligns them. The main objective of this paper is to evaluate several wavelet pyramids that may be used both for invariant feature extraction and for representing images at multiple spatial resolutions to accelerate registration. We find that the bandpass wavelets obtained from the steerable pyramid due to Simoncelli performs best in terms of accuracy and consistency, while the low-pass wavelets obtained from the same pyramid give the best results in terms of the radius of convergence. Based on these findings, we propose a modification of a gradient-based registration algorithm that has recently been developed for medical data. We test the modified algorithm on several sets of real and synthetic satellite imagery.

Evaluation Studies↗

Evaluating EUV mask pattern imaging with two EUV microscopes

Aerial image measurement plays a key role in the development of patterned reticles for each generation of lithography. Studying the field transmitted (reflected) from EUV masks provides detailed information about potential disruptions caused by mask defects, and the performance of defect repair strategies, without the complications of photoresist imaging. Furthermore, by measuring the continuously varying intensity distribution instead of a thresholded, binary resist image, aerial image measurement can be used as feedback to improve mask and lithography system modeling methods. Interest in EUV, at-wavelength, aerial image measurement lead to the creation of several research tools worldwide. These tools are used in advanced mask development work, and in the evaluation of the need for commercial at-wavelength inspection tools. They describe performance measurements of two such tools, inspecting the same EUV mask in a series of benchmarking tests that includes brightfield and darkfield patterns. One tool is the SEMATECH Berkeley Actinic Inspection Tool (AIT) operating on a bending magnet beamline at Lawrence Berkeley National Laboratory's Advanced Light Source. The AIT features an EUV Fresnel zoneplate microscope that emulates the numerical aperture of a 0.25-NA stepper, and projects the aerial image directly onto a CCD camera, with 700x magnification. The second tool is an EUV microscope (EUVM) operating at the NewSUBARU synchrotron in Hyogo, Japan. The NewSUBARU tool projects the aerial image using a reflective, 30x Schwarzschild objective lens, followed by a 10-200x x-ray zooming tube. The illumination conditions and the imaging etendue are different for the two tools. The benchmarking measurements were used to determine many imaging and performance properties of the tools, including resolution, modulation transfer function (MTF), aberration magnitude, aberration field-dependence (including focal-plane tilt), illumination uniformity, line-edge roughness, and flare. These measurements reveal the current state of the art in at-wavelength inspection performance, and will be a useful reference as performance improves over time.

36 MATERIALS SCIENCE↗

Regional Climate Simulation with a Variable Resolution Stretch Grid GCM: The 1998 Summer Drought

The variable resolution stretched grid(SG) GCM based on the Goddard Earth Observing System (GEOS) GCM, has been developed and tested in a regional climate simulation mode. The GEOS SG-GCM is used for simulation of the 1988 summer drought over the U.S. Midwest. Within the stretched grid, the region of interest with a uniform about 60 km resolution is a rectangle over the U.S. Outside the region, the grid intervals increase or stretch with a constant stretching factor (as a geometric progression). The results of two-month simulation for the anomalous climate event of the U.S. drought of 1988, are validated against data analysis fields and diagnostics. The event has been chosen by the Project to Inter-compare Regional Climate Simulations(PIRCS). The efficient regional down-scaling as well as the positive impact of fine regional resolution, are obtained. More specifically, the precipitation, 500 hPa, and low-level jet patterns and characteristics are well represented in the simulation. The SG-concept appeared to be a promising candidate for regional and subregional climate studies and applications.

Fox-Rabinovitz, Michael↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗

A Mode Detection Method Using the Azimuthal Directivity of a Turbofan Model

The azimuthal, far field directivity of a scale fan model was measured in high resolution. The model is a 12 inch diameter rotor with 16 blades followed by 40 stator vanes. The tests were conducted at the nominal 100% speed corresponding to a tip speed of 905 ft/sec. Measurement of the radiated sound field, forward of the fan, was made in an anechoic chamber with an inflow control device and a baffle separating the aft and forward radiated interaction noise. The acoustic field was surveyed with a circular hoop array of 16 microphones which was moved to 14 axial stations. At each axial station the hoop was rotated in half-degree increments to take 736 points in the azimuthal angle. In addition to sound pressure level, the phase angle relative to a reference microphone was measured at each point. The sound pressure level is shown to vary in patterns by 10-15 dB especially for the fundamental tone but also for the first and second harmonic. A far field mode detection method has been developed and used with the data which determines the modes generated by the fan and which then interact to form the azimuthal directivity.

Thomas, R. H.↗

SWIRP (Submm-Wave and Long Wave InfraRed Polarimeter); Development and Characterization of a Sub-Mm Polarimeter for Ice Cloud Investigations

A major source of uncertainty in climate models is the presence, shape and distribution of ice particles in the uppermost layers of the clouds. The effects of this component are poorly constrained, turning ice particles into an almost-free variable in many climate models.NASA-GSFC is developing a new instrument aimed at measuring the size and shape of ice particles. The instrument consists of two sub-mm polarimeters (at 220 and 670 GHz) coupled with a long-wave infrared polarimeter at 10 micron. Each polarimeter has identical V-pol and H-pol channels; the axes of polarization are defined geometrically by the orientation of the waveguide elements, and the purity has been measured in the lab. The instrument is configured as a conical scanner, suitable for deployment as a payload on a small satellite or on a high-altitude sub-orbital platform. From a 400 km orbit, the instrument has a 3dB spatial resolution of 20 (10) km at 220 (670) GHz and a swath of 600 km over 180 degrees of view.The BAPTA (Bearing And Power Transfer Assembly) carries heritage from the SSMIS design, now in its 22nd year of on-orbit operation, but with a much reduced SWaP (Size Weight and Power) footprint, suitable for a small satellite.The main components of the instrument have been fabricated and are undergoing final testing prior to their integration as a single unit. The sub-mm channels have dedicated secondary reflectors which illuminate a shared primary reflector. The receiving units are placed behind the focal point of the optical arrangement, so that all beams equally illuminate the primary reflector and are almost co-located on the ground (within a single 220 GHz footprint). Primary and secondary beam patterns have been measured and verified to match the as-designed expectations. A Zytex (TM) window is deployed to protect the secondary reflectors and the feed horns from debris and other contaminants, and to reduce the heat load from the active (hot) IR calibration unit. The insertion loss of Zytex has been measured and is accounted in the calibration equation of the sub-mm channels.The radiometric performance of the sub-mm receivers has been characterized in the lab and under operational conditions of temperature and pressure.This paper discusses the design constraints on the sub-mm components, details of the scientific goals and their flowdown, and describes the characterization of the polarimeters. Options to optimize the layout and distribution of the masses within the assembly, with the goal of making the instrument even more compact and fully-compatible with cubesat-class satellites will be presented.

De Amici, G.↗

Rapid Prototyping Integrated With Nondestructive Evaluation and Finite Element Analysis

Most reverse engineering approaches involve imaging or digitizing an object then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. Rapid prototyping (RP) refers to the practical ability to build high-quality physical prototypes directly from computer aided design (CAD) files. Using rapid prototyping, full-scale models or patterns can be built using a variety of materials in a fraction of the time required by more traditional prototyping techniques (refs. 1 and 2). Many software packages have been developed and are being designed to tackle the reverse engineering and rapid prototyping issues just mentioned. For example, image processing and three-dimensional reconstruction visualization software such as Velocity2 (ref. 3) are being used to carry out the construction process of three-dimensional volume models and the subsequent generation of a stereolithography file that is suitable for CAD applications. Producing three-dimensional models of objects from computed tomography (CT) scans is becoming a valuable nondestructive evaluation methodology (ref. 4). Real components can be rendered and subjected to temperature and stress tests using structural engineering software codes. For this to be achieved, accurate high-resolution images have to be obtained via CT scans and then processed, converted into a traditional file format, and translated into finite element models. Prototyping a three-dimensional volume of a composite structure by reading in a series of two-dimensional images generated via CT and by using and integrating commercial software (e.g. Velocity2, MSC/PATRAN (ref. 5), and Hypermesh (ref. 6)) is being applied successfully at the NASA Glenn Research Center. The building process from structural modeling to the analysis level is outlined in reference 7. Subsequently, a stress analysis of a composite cooling panel under combined thermomechanical loading conditions was performed to validate this process.

Abdul-Aziz, Ali↗

Transmission Geometry Laser Ablation into a Non-Contact Liquid Vortex Capture Probe for Mass Spectrometry Imaging

RATIONALE: Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. Methods: A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) setup to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. Results: The estimated capture efficiency of laser ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (~ 2.8 mm2) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution of not only particulates, but also gaseous products of the laser ablation. The use of DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 m was demonstrated for stamped ink on DIRECTOR slides based on the ability to distinguish features present both in the optical and in the chemical image. This imaging resolution was 20 times better than the previous best reported results with laser ablation/liquid sample capture mass spectrometry imaging. Using thin sections of brain tissue the chemical image of a selected lipid was obtained with an estimated imaging resolution of about 50 um. Conclusions: A vertically aligned, transmission geometry laser ablation liquid vortex capture probe, electrospray ionization mass spectrometry system provides an effective means for spatially resolved spot sampling and imaging with mass spectrometry.

DIRECTOR slides↗

Microseismic at HFTS2: A Story of Three Stimulated Wells

A microseismic data set was acquired at Hydraulic Fracturing Test Site 2 (HFTS2) in the Delaware Basin (Texas, USA) by the HFTS2 consortium as a part of data-collection program designed to help maximize the efficiency of hydraulic fracturing, understand the impacts of nearby depleted zones, and increase the production of hydrocarbons. Advanced methods of microseismic monitoring applied at HFTS2 include 1) native synchronization of five monitor arrays, 2) real-time location of microseismic events, 3) joint event hypocenter/ velocity-model inversion that locates microseismic events simultaneously with constructing azimuthally anisotropic velocity models, 4) high-resolution reservoir imaging, utilizing microseismic events as downhole sources. HFTS2 microseismic data set illustrated the influence of geologic complexity, variations in treatment designs, and the presence of parent wells on the efficiency of hydraulic fracturing. Three Wolfcamp wells, Boxwood 1H, 2H, and 4H, were stimulated sequentially, exhibiting very different patterns of microseismicity. When the Boxwood 1H well is stimulated, its toe stages quickly reacted to the presence of depleted Bitterroot section to the east of the Boxwood pad, extending microseismic events over 3,000 ft to the east. This behavior changes dramatically after the treatment passes the Bitterroot section at the toe, and the heel stages in 1H showed tight microseismic grouping around the stimulated well, indicative of treatment of virgin reservoir rock. The Boxwood 2H demonstrates this same pattern of behavior between the toe and heel stages of the well, suggesting that the depleted Bitterroot section remains easier to refracture than adjacent non-depleted rock. Microseismic activity associated with Boxwood 4H treatment is distinctly different from those in Boxwood wells 1H and 2H. The events generated during stimulation of 4H are hardly influenced by the depleted Bitterroot section and fill the space between the previously stimulated 1H and 2H wells. Altogether, microseismic patterns suggest that treatment fluids tend to find the weakest passages through geologic formations, and the relative well positions and treatment sequence have a significant impact on fracture geometry, as indicated by microseismic event locations.

58 GEOSCIENCES↗

Numerical analysis of three complex three-dimensional shock wave / turbulent boundary layer interaction flows

A set of Reynolds-averaged Navier-Stokes (RANS) computations with turbulence closure provided by the Spalart-Allmaras (SA) model have been carried out for prediction of shock-induced three-dimensional (3D) turbulent separated flows. The experimental data for different aerodynamic test configurations have been used for assessing credibility of the numerical method employed. Particularly, shock wave / turbulent boundary layer interactions (SWTBLI) in the vicinity of an asymmetric sharp double-fin (DF) with different (7° and 11°) deflection angles mounted on a flat plate and two conically sharp cylindrical bodies at varying interbody distances and nose cone angles 60° and 40° mounted over a flat plate at freestream Mach number 4, as well as a transonic fan stage operating in the near-stall regime are considered. The gas dynamic structure and topology of 3D separated flows, surface flow patterns, and pressure distributions as well as body aerodynamic force prediction are analyzed. A transonic fan stage operating in the near-stall regime and a possibility of applying flow control is investigated. High Performance Computing was employed to make high resolution computations of these flows possible, and advanced 3D visualization techniques were employed in order to improve understanding of the separating flow phenomena.

42 ENGINEERING↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

North Pacific Mesoscale Coupled Air-Ocean Simulations Compared with Observations

Executive summary The main objective of the study was to investigate atmospheric and ocean interaction processes in the western Pacific and, in particular, effects of significant ocean heat loss in the Kuroshio and Kuroshio Extension regions on the lower and upper atmosphere. It is yet to be determined how significant are these processes are on climate scales. The understanding of these processes led us also to development of the methodology of coupling the Weather and Research Forecasting model with the Parallel Ocean Program model for western Pacific regional weather and climate simulations. We tested NCAR-developed research software Coupler 7 for coupling of the WRF and POP models and assessed its usability for regional-scale applications. We completed test simulations using the Coupler 7 framework, but implemented a standard WRF model code with options for both one- and two-way mode coupling. This type of coupling will allow us to seamlessly incorporate new WRF updates and versions in the future. We also performed a long-term WRF simulation (15 years) covering the entire North Pacific as well as high-resolution simulations of a case study which included extreme ocean heat losses in the Kuroshio and Kuroshio Extension regions. Since the extreme ocean heat loss occurs during winter cold air outbreaks (CAO), we simulated and analyzed a case study of a severe CAO event in January 2000 in detail. We found that the ocean heat loss induced by CAOs is amplified by additional advection from mesocyclones forming on the southern part of the Japan Sea. Large scale synoptic patterns with anomalously strong anticyclone over Siberia and Mongolia, deep Aleutian Low, and the Pacific subtropical ridge are a crucial setup for the CAO. It was found that the onset of the CAO is related to the breaking of atmospheric Rossby waves and vertical transport of vorticity that facilitates meridional advection. The study also indicates that intrinsic parameterization of the surface fluxes within the WRF model needs more evaluation and analysis.

54 ENVIRONMENTAL SCIENCES↗

Validation Data Acquisition in HTTF during PCC Events

A validation experimental campaign was conducted in an Integral Effect Test (IET) facility of High Temperature Gas Reactors (HTGR), the High-Temperature Test Facility (HTTF) at Oregon State University (OSU). The HTTF simulates Depressurized and Pressurized Conduction Cooldowns (DCC and PCC). This campaign required the development of a new laser spectroscopic diagnostic to measure velocity in the challenging conditions of the HTTF: low speed (~1 m/s) gas flows at HTGR prototypical temperature and 1/10th pressure. This was a collaborative effort between co-PIs at The George Washington University (GW), Oregon State University (OSU), and NASA Langley Research Center. The main accomplishments of this project include the record for dynamic range for velocimetry, highest accuracy obtained with this technique, successful deployment in an IET leading to new validation matrix for CFD. These are detailed below and in manuscript appended to this executive summary. For this project, we introduced a new class of laser spectroscopic diagnostics to Thermal-Hydraulics to measure velocity of gases; furthermore, the diagnostic was demonstrated in-situ in an IET during DCC events. In such scenarios, particles used in mainstream techniques, like Particle Image Velocimetry (PIV) are not appropriate as they settle down too rapidly and also contaminate the experimental facility. Molecular tracers stay mixed within the working gas and can seed the flow in a technique called Molecular Tagging Velocimetry (MTV). In MTV a molecular tracer is photo-dissociated by a first (write) laser into radicals or molecules. The pattern created by the write laser is then interrogated with planar laser-induced fluorescence (PLIF), the read pulse(s), which are recorded with a camera. The pattern is probed and matched at two times (interval or probe time, dt), resulting in a time-of-flight velocimetry technique. This project demonstrated a new application range for MTV in gases. MTV has been extensively used for high-speed gas dynamics: molecules do not suffer from inertia associated with particles in regions of high accelerations (such as shock waves). For high-speed flows, the probe time is on the order of 0.1-10 µs. In time-of-flight techniques, the velocity is reconstructed from the recorded displacement, dx, between time interval dt: U = dx/dt. To first order, the resolution of the pattern matching is typically a (fixed) fraction of a pixel; therefore the resolution of the velocity measurement increases with dx and, for a given flow velocity, dt. For the low-speed flows of interest here, this requires long probe time, and therefore finding tracers that are stable for a long time. After an extensive literature survey we identified 6 tracers that would be suitable. We also worked with Spectra Physics to design a custom laser system that is flexible enough to probe these various tracers. The final instrument is made of 4 lasers that are integrated into a compact and movable cart to facilitate the deployment of the instrument off-site. One unique aspect of the laser system is the tunable dye laser (needed to do PLIF of the radicals). By being pumped by two Nd:YAG lasers, this laser is able to provide two pulses with any probe time (dt) for wavelengths between 200 and 900 nm with a linewidth of 3 pm. Accommodating the dual-pulse capability required customizing the pump lasers and the dye laser, making this system unique. Additionally, a custom UV-intensified CCD camera capable of frame-straddling and exposure time as short as 10 ns was acquired. More than two-third of the instrument cost (~$200k) was covered by a cost sharing from the PI’s startup funds. Of the 6 potential tracers identified, two were tested extensively (H2O and N2O) at high-temperature and elevated pressure at GW prior to conducting the tests at OSU. For both tracers, an Ar-F laser (193 nm, 10 ns, 10 mJ/pulse) photo-dissociates trace amounts (0.1 – 5% molar fraction) of the gases into OH and NO. OH is probed at 281.905 nm and NO at 226.186 nm (4-30mJ, 10 ns pulse). NO is very stable in inert environment and we could reconstruct velocities precisely with probe delay times as long at 40 ms, compared to 2 ms for OH, resulting in increased precision. Therefore, for the tests in the HTTF, N2O was selected as the final tracer and its optimal concentration was determined to be 0.5% molar. In the GW laboratory, we obtained a velocity measurement precision of 4 mm/s at conditions mimicking the HTTF tests. We also demonstrated the benefit of molecular tracers over particles and the flexibility of our instrument by continuously measuring velocity from 1000 to 0.1 m/s in a blow down test. This represents a dynamic range on velocity of 80 dB, which is unprecedented for velocimetry! Once the diagnostic was optimized, two two-week campaigns were conducted in the HTTF. This experimental campaign required numerous practical solutions to successfully and rapidly deploy this very sensitive table-top diagnostic in-situ. This was accomplished thanks to very extensive planning from all parties involved in the project. Due to constraints on availability of the HTTF, only adiabatic DCC tests were conducted. Specifically, the velocity was measured at the exit of the hot leg into the Reactor Cavity Simulation Tank (RCST). We were able to record the gas velocity associated with the air ingress for long times (up to one hour). Depending on the initial conditions (density of the gases in the Reactor Pressure Vessel and the RCST) the lock exchange lasted 30-60 s past the valve openings. Large vortices were identified within the shear layer at the interface of the cross flow. These vortices are an indication of shear-driven instability between the counter streams of different density. After the lock-exchange, a small residual flow was still present and its strength decayed exponentially. It finds its source in a buoyancy difference between the gases in both vessels due to the mixing and diffusion of the gases in the cross-over duct and the RPV lower plenum. We did not expect to capture this part of the transient, which would have been less significant (if not negligible) in the presence of a heated core; the precision of our measurement in the HTTF was 6 mm/s, which exceeded our expectations for such a complex test! Using commercial software (Fluent) we simulated the experiment with Computational Fluid Dynamic (CFD) using Reynolds Averaged Navier-Stokes (RANS) turbulence models. We were not able to accurately reproduce the shear layer instability, mixing, and diffusion captured in our experimental data, even with large 3D meshes (>10 M points). We attributed this to the inadequacy of the RANS models for the flow of interest: our experimental Reynolds number was too low and was outside the applicability range of the RANS models. Instead, we should have employed CFD with less modeling, such as Large Eddy (LES) or even Direct Numerical (DNS) simulations. Unfortunately, we did not have the computational resources to do so. Finally, it should be noted that this experimental technique holds great promises for measuring velocity in thermalhydraulics. MTV has an application domain (highlighted in the narrative) that is complimentary to more established (and simpler) techniques, such as PIV. It has attracted the attention of several thermalhydraulics researchers and sponsors to measure velocity in harsh environments. The spectroscopic nature of this technique also enables to expand it to measure temperature and concentration simultaneously to velocity. In lieu of a narrative, 4 detailed journal publications are appended to this executive summary to describe the various development and accomplishments during this project. They include 2 published manuscripts (Experiments in Fluids and Measurement Science and Technology), and two invited contributions following the NURETH-17 conference (Nuclear Science and Technology). Our current Nuclear Engineering and Design draft is not included at this time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Single photon detection with the multi-anode CLAS12 RICH detector

Recently, the first module of the hybrid-optics large-area CLAS12 RICH at JLab has been put into operation using for the first time the well known Hamamatsu H8500 MAPMT and the new single-photon dedicated H12700, for a total of about 400 MAPMTs and 25000 pixels. The photon detector must efficiently detect single photons in the visible and near-UV light region, provide a fast response for background rejection and pattern recognition, and have a spatial resolution of less than 1 cm over an area of ≈1 m 2 . Each front-end readout unit is composed of three electronic boards with specific tasks directly connected to groups of 2 or 3 sensors. The core of the readout is composed of MAROC3 and FPGA chips. The MAROC3 chip is able to discriminate the 64 signals from one MAPMT and to produce 64 corresponding binary outputs with 100% efficiency starting at a small fraction of the single-photon signal, while the FPGA chip provides 1 ns TDC capability with 8 μs maximum latency and acts as a DAQ controller. The system is created to be almost dead-time free at the foreseen 20 kHz CLAS12 trigger rate. The best working conditions for single-photon detection have been studied at laser stands, test beams, and with the JLab electron beam data. A report of the photon detector preparation, commissioning and operation is here discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence In Situ mRNA Hybridization for Gene Expression Detection in a Wood Decay Fungus

Wood-degrading fungi efficiently decompose wood using a series of steps that are regulated across time and space. RNA sequencing with “bulk” sampling method has indicated processes controlled at the transcription level at different decay stages and locations along hyphal networks. To further understand these regulatory mechanisms, a high-resolution technique for gene expression determination is required. In this work, Fluorescence In Situ Hybridization (FISH) of mRNA was tested and optimized in the ‘brown rot’-type (carbohydrate-selective; lignin-rich residues) model fungus Postia (Rhodonia) placenta to image gene expression at the hyphal scale, <10 micrometers. The mRNA of one housekeeping gene Tef1a and three wood-decaying genes Cel28a, Cel5b and Qrd1 were tested in hyphae grown in liquid nutrients and wood substrate. The 20 bp-long DNA probes were successfully delivered intracellularly to give sufficient hybridization signal for imaging. Ahead of hybridization, permeabilization by lyticase and proteinase K treatments proved to be the critical step to increase probe and mRNA accessibility. Tyramide signal amplification was used after hybridization to enhance signal. This gave qualitative measures of mRNA of the four target genes, which were generally in line with previous expression patterns generated from coarser-scale RNA-seq and qRT-PCR studies. These techniques were not without challenges, and future optimization using multiple probe fragments for each mRNA molecule is proposed.

Brown rot fungi, decomposition, FISH, gene express↗