Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample identifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Evaluating various composite sampling modes for detecting pathogenic SARS-CoV-2 virus in raw sewage

Inadequate sampling approaches to wastewater analyses can introduce biases, leading to inaccurate results such as false negatives and significant over- or underestimation of average daily viral concentrations, due to the sporadic nature of viral input. To address this challenge, we conducted a field trial within the University of Tennessee residence halls, employing different composite sampling modes that encompassed different time intervals (1 h, 2 h, 4 h, 6 h, and 24 h) across various time windows (morning, afternoon, evening, and late-night). Our primary objective was to identify the optimal approach for generating representative composite samples of SARS-CoV-2 from raw wastewater. Utilizing reverse transcription-quantitative polymerase chain reaction, we quantified the levels of SARS-CoV-2 RNA and pepper mild mottle virus (PMMoV) RNA in raw sewage. Our findings consistently demonstrated that PMMoV RNA, an indicator virus of human fecal contamination in water environment, exhibited higher abundance and lower variability compared to pathogenic SARS-CoV-2 RNA. Significantly, both SARS-CoV-2 and PMMoV RNA exhibited greater variability in 1 h individual composite samples throughout the entire sampling period, contrasting with the stability observed in other time-based composite samples. Through a comprehensive analysis of various composite sampling modes using the Quade Nonparametric ANCOVA test with date, PMMoV concentration and site as covariates, we concluded that employing a composite sampler during a focused 6 h morning window for pathogenic SARS-CoV-2 RNA is a pragmatic and cost-effective strategy for achieving representative composite samples within a single day in wastewater-based epidemiology applications. This method has the potential to significantly enhance the accuracy and reliability of data collected at the community level, thereby contributing to more informed public health decision-making during a pandemic.

sampling timing↗

MolDiscovery: learning mass spectrometry fragmentation of small molecules

Identification of small molecules is a critical task in various areas of life science. Recent advances in mass spectrometry have enabled the collection of tandem mass spectra of small molecules from hundreds of thousands of environments. To identify which molecules are present in a sample, one can search mass spectra collected from the sample against millions of molecular structures in small molecule databases. The existing approaches are based on chemistry domain knowledge, and they fail to explain many of the peaks in mass spectra of small molecules. Here, we present molDiscovery, a mass spectral database search method that improves both efficiency and accuracy of small molecule identification by learning a probabilistic model to match small molecules with their mass spectra. A search of over 8 million spectra from the Global Natural Product Social molecular networking infrastructure shows that molDiscovery correctly identify six times more unique small molecules than previous methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SCA Tools - SCRM Value Add or Lossy Noise Machines

Software supply chain risk management (SCRM) depends upon accurate information regarding the software components that comprise any given software system. The collection of components included in a software package can be organized within a software bill of materials, or SBOM. SBOMs are ideally generated when the software components are put together, such as at compile time, but for many reasons that has not and is not always possible. For example, legacy or proprietary software packages often do not have SBOMs available to downstream consumers of that software. It’s not just end users that are affected, manufacturers themselves also must deal with this problem. To answer these questions, the market has seen the rise of several commercial software composition analysis (SCA) tools. These tools aim to peer into completed software systems, automatically identifying hidden software dependencies and looking up known vulnerabilities associated with those dependencies to enable end-users to enhance their cyber supply chain risk management processes. These tools are potentially a huge boon to end users of legacy and proprietary software – and a potential bane, depending on how accurate they are. This research asks that question – how accurate are currently available binary SCA tools – and provides answers to several other questions: What does it mean to be “accurate”? What limitations do the tools have in identifying common edge cases that take place in modern software development? Can they help you avoid a devastating supply chain attack, or is it all just noise? After researching SCA tools on the market, we identified three vendors that fit our use case and would provide analysis on compiled binaries. Using these tools, we submitted firmware for critical infrastructure devices for analysis and SBOM generation. The SBOM outputs were then cross referenced with SBOMs generated through manual analysis for comparison. In addition to the firmware samples, we also submitted edge case samples based off a popular open-source library that were specifically crafted to evaluate each tools’ ability to accurately identify components. These samples were customized to be consistent with modifications we have seen in modern software development as well as a couple that are representative of supply chain attacks.

97 MATHEMATICS AND COMPUTING↗

DESI z ≳ 5 Quasar Survey. I. A First Sample of 400 New Quasars at z ~ 4.7–6.6

We report the first results of a high-redshift (z ≳ 5) quasar survey using the Dark Energy Spectroscopic Instrument (DESI). As a DESI secondary target program, this survey is designed to carry out a systematic search and investigation of quasars at 4.8 < z < 6.8. The target selection is based on the DESI Legacy Imaging Surveys (the Legacy Surveys) DR9 photometry, combined with the Pan-STARRS1 data and J-band photometry from public surveys. A first quasar sample has been constructed from the DESI Survey Validation 3 (SV3) and first-year observations until 2022 May. This sample includes more than 400 new quasars at redshift 4.7 ≤ z < 6.6, down to 21.5 magnitude (AB) in the z band, discovered from 35% of the entire target sample. Remarkably, there are 220 new quasars identified at z ≥ 5, more than one-third of existing quasars previously published at this redshift. The observations so far result in an average success rate of 23% at z > 4.7. The current spectral data set has already allowed analysis of interesting individual objects (e.g., quasars with damped Lyα absorbers and broad absorption line features), and statistical analysis will follow the survey's completion. A set of science projects will be carried out leveraging this program, including quasar luminosity function, quasar clustering, intergalactic medium, quasar spectral properties, intervening absorbers, and properties of early supermassive black holes. Additionally, a sample of 38 new quasars at z ~ 3.8–5.7 discovered from a pilot survey in the DESI SV1 is also published in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerating Nature: Induced Atomic Order in Equiatomic FeNi

Abstract The production of locally atomically ordered FeNi (known by its meteoric mineral name, tetrataenite) is confirmed in bulk samples by simultaneous conversion X‐ray and backscattered γ‐ray 57 Fe Mössbauer spectroscopy. Up to 22 volume percent of the tetragonal tetrataenite phase is quantified in samples thermally treated under simultaneous magnetic‐ and stress‐field conditions for a period of 6 weeks, with the remainder identified as the cubic FeNi alloy. In contrast, all precursor samples consist only of the cubic FeNi alloy. Data from the processed alloys are validated using Mössbauer parameters derived from natural meteoritic tetrataenite. The meteoritic tetrataenite exhibits a substantially higher degree of atomic order than do the processed samples, consistent with their low uniaxial magnetocrystalline anisotropy energy of ≈1 kJ·m −3 . These results suggest that targeted refinements to the processing conditions of FeNi will foster greater atomic order and increased magnetocrystalline anisotropy, leading to an enhanced magnetic energy product. These outcomes also suggest that deductions concerning paleomagnetic conditions of the solar system, as derived from meteoritic data, may warrant re‐examination and re‐evaluation. Additionally, this work strengthens the argument that tetrataenite may indeed become a member of the advanced permanent magnet portfolio, helping to meet rapidly escalating green energy imperatives.

36 MATERIALS SCIENCE↗

Host-specific and tissue-dependent orchestration of microbiome community structure in traditional rice paddy ecosystems

Abstract Background and aim Rice and duckweed are two monocotyledonous plants that naturally coexist in paddy fields. While the presence of duckweed in paddy fields significantly improves rice productivity, the interplay between soil microbes and the two plant hosts in this agroecosystem remains unexplored. Methods We compared the bacterial community structure between duckweed, rice and soil from multiple rice paddies. We also isolated bacteria from these communities and characterized their modes of bacterial colonization and plant growth-promotion using model plants. Results Our data indicate that host-specific and tissue-dependent factors reproducibly orchestrate the bacterial community structure associated with their plant hosts. This is corroborated by results from culture-dependent approaches in which the dominant genus Pantoea isolated from rice aerial tissues can strongly attach and colonize gnotobiotic duckweed in spite of the low representation of this bacterial genus in the natural duckweed microbiome. Our study identified a core of 254 bacterial taxa that are consistently found in all rice and duckweed tissue samples from rice paddy fields. Furthermore, characterizing auxin-producing bacteria isolates from both plant species identified potential plant growth-promoting bacteria that may improve growth for both duckweed and rice in paddy fields. Conclusions Results from this work provide evidence for the importance of the host tissue and species context in determining plant colonization by microbes in the paddy field system. The resources generated in this study could facilitate the agronomic deployment of microbes for more sustainable rice production.

Agriculture↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration and Uncertainty Estimation Using the Ensemble Kalman Filter with a Large Subsurface Flow and Transport Model - 20321

At routinely monitored groundwater contamination sites, periodically measured environmental conditions such as groundwater levels and contaminant concentrations are used to inform and confirm a conceptual site model (CSM) and guide the development and calibration of a numerical groundwater flow and transport model. The calibration of groundwater flow and transport models after each measurement (sampling) event can illuminate deficiencies in a CSM, identify areas where additional monitoring is warranted, and predict the behavior of the system to guide decision making. However, manual and automated (e.g. PEST) model calibration tools can be time-consuming and computationally expensive to implement after each sampling event. Perhaps as a result, such calibration tools generally utilize all available monitoring data simultaneously rather than sequentially assimilating monitoring data one sampling event at a time as the results from sampling become available. A more real-time data assimilation approach may reduce parameter uncertainty, quantify the value of additional monitoring data, and produce a usable model more quickly and with less effort. To mitigate the potential time-consuming aspects of manual and widely applied automated calibration techniques, a data assimilation algorithm called the ensemble Kalman filter (EnKF) was evaluated as a relatively efficient method of model calibration and uncertainty assessment via the sequential integration of monitoring data into a model. The EnKF was able to successfully and efficiently assimilate monitoring and modeling data to calibrate a complex flow and transport model at a real-world site with significant subsurface heterogeneity, uncertainty, and 12 years of monitoring data (over 4,000 individual measurements of groundwater levels and over 2,500 measurements of contaminant concentrations). Starting with an uncalibrated model data from annual sampling events were sequentially assimilated, and the resultant predication errors and estimated parameter uncertainties were tracked. After all monitoring data were assimilated, both flow and transport residuals at the end of the EnKF process were comparable to those produced via a concurrent PEST calibration effort but required fewer model simulations. Both uncertainty and prediction errors decreased over time. In a real-time application, the adequacy of the model could be assessed after each sampling event. The benefits of such a real-time approach to utilizing monitoring data include reduced costs (in the form of model updates or site characterization efforts), early flagging of possible errors in the CSM, and a reduced risk of overfitting and corresponding increased confidence in model predictions. This tool may be particularly useful compared to other calibration techniques (e.g. manual, PEST) when model runtimes are long, calibration parameters are many, or parameter uncertainty is large. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatially Resolved Top-Down Proteomics of Tissue Sections Based on a Microfluidic Nanodroplet Sample Preparation Platform

Conventional proteomics measures the averaged signal from mixed cell populations or bulk tissues, leading to the dilution of significant changes in subpopulations of cells that might serve as important biomarkers. Recent developments in bottom-up proteomics have enabled spatial mapping of cellular heterogeneity in tissue microenvironments. However, bottom-up proteomics cannot precisely infer the abundance changes of intact proteins, which are presented as proteoforms. Herein, we described a spatially resolved top-down proteomics (TDP) platform for proteoform identification and quantification directly on thin tissue sections. The spatial TDP platform consisted of a nanoPOTS (nanodroplet Processing in One pot for Trace Samples)-based sample preparation system and an LCM (laser capture microdissection)-based cell isolation system. We improved the nanoPOTS sample preparation by adding benzonase in the extraction buffer to enhance the coverage of nucleus proteins. Using ~200 cultured cells as model samples, the improved approach increased proteoform identifications from 493 to 700; newly identified proteoforms primarily corresponded to nuclear proteins. To demonstrate the spatial TDP platform in tissue samples, we analyzed LCM-isolated tissue voxels from rat brain cortex and hypothalamus regions. We quantified 426 proteoforms by combining identifications from TopPIC and TDPortal with the quantitation from ProMex. Several proteoforms corresponding to the same gene exhibited mixed abundance profiles between two tissue regions, suggesting potential PTM-specific spatial distributions. The spatial TDP workflow has prospects for biomarker discovery at proteoform level from small tissue sections.

59 BASIC BIOLOGICAL SCIENCES↗

Low-mass Group Environments Have No Substantial Impact on the Circumgalactic Medium Metallicity

We explore how environment affects the metallicity of the circumgalactic medium (CGM) using 13 low-mass galaxy groups (two to five galaxies) at &lang;z{sub abs}&rang;=0.25 identified near background quasars. Using quasar spectra from the Hubble Space Telescope/COS and from Keck/HIRES or the Very Large Telescope/UVES, we measure column densities of or determine limits on CGM absorption lines. We use a Markov Chain Monte Carlo approach with Cloudy to estimate metallicities of cool (T ~ 10{sup 4} K) CGM gas within groups and compare them to CGM metallicities of 47 isolated galaxies. Both group and isolated CGM metallicities span a wide range (-2 < [Si/H] < 0), where the mean group (-0.54 ± 0.22) and isolated (-0.77 ± 0.14) CGM metallicities are similar. Group and isolated environments have similar distributions of H I column densities as a function of impact parameter. However, contrary to isolated galaxies, we do not find an anticorrelation between H I column density and the nearest group galaxy impact parameter. We additionally divided the groups by member luminosity ratios (i.e., galaxy–galaxy and galaxy–dwarf groups). While there was no significant difference in their mean metallicities, a modest increase in sample size should allow one to statistically identify a higher CGM metallicity in galaxy–dwarf groups compared to galaxy–galaxy groups. We conclude that either environmental effects have not played an important role in the metallicity of the CGM at this stage and expect that this may only occur when galaxies are strongly interacting or merging or that some isolated galaxies have higher CGM metallicities due to past interactions. Thus, environment does not seem to be the cause of the CGM metallicity bimodality.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO 2 induced changes in Mount Simon sandstone: Understanding links to post CO 2 injection monitoring, seismicity, and reservoir integrity

The purpose of this study is to quantify geochemical reactions of CO 2 and brine with subsurface samples taken from the Mt. Simon sandstone and identify any potential alterations of the geomechanical rock properties that could lead to changes observable in seismic monitoring or result in changes of micro seismicity such as those observed at the Illinois Basin-Decatur Project (IBDP) site. Two Mt. Simon sandstone samples from 6919.3 feet (2109.0 m) and 6926.1 feet (2111.1 m) depth were exposed to supercritical CO 2 (scCO 2 ) dissolved in brine at in-situ reservoir conditions for one month. Geochemical, spectral, scanning electron microscopy, and petrophysical methods were used to analyze the samples before and after the one-month exposure. Significant changes were observed. Multiple geomechanical properties were chosen to form the framework against which to interrogate the petrophysical data: Young’s modulus (E), Poisson’s ratio (ν), lambda·rho (λρ), and mu·rho (μρ). In this study we conclude that framework composition, porosity, heterogeneities, effective pressure, and reactive geochemistry are first order controls on trends in the E-μ and λρ-μρ cross plot spaces. Changes in porosity, permeability, dynamic moduli, and brittleness with exposure to these fluids were observed. No change in ultrasonic P-wave attenuation (Q P ) was observed. Geochemical alteration causes a distinct shift in λρ-μρ in both samples as well as changes in E, ν, and P and S wave seismic velocity values. Furthermore, these observations could provide insight into subsurface monitoring using seismic methods including amplitude variation with offset (AVO) classification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasars Acting as Strong Lenses Found in DESI DR1

Quasars acting as strong gravitational lenses offer a rare opportunity to probe the redshift evolution of scaling relations between supermassive black holes and their host galaxies, particularly the M$_{BH}$–M$_{host}$ relation. Using these powerful probes, the mass of the host galaxy can be precisely inferred from the Einstein radius θ$_{E}$. Using 812,118 quasars from DESI DR1 (0.03 ≤ z ≤ 1.8), we searched for quasars lensing higher-redshift galaxies by identifying background emission-line features in their spectra. To detect these rare systems, we trained a convolutional neural network (CNN) on mock lenses constructed from real DESI spectra of quasars and emission-line galaxies (ELGs), achieving a high classification performance (AUC = 0.99). We also trained a regression network to estimate the redshift of the background ELG. Applying this pipeline, we identified seven high-quality (Grade A) lens candidates, each exhibiting a strong [O II] doublet at a higher redshift than the foreground quasar; four candidates additionally show Hβ, [O III] λ4959, and [O III] λ5007 emission. These results significantly expand the sample of quasar lens candidates beyond the 12 identified and 3 confirmed in previous work and demonstrate the potential for scalable, data-driven discovery of quasars as strong lenses in upcoming spectroscopic surveys.

McArthur, Everett [Stanford U., Phys. Dept.; KIPAC↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polynomial chaos expansions on principal geodesic Grassmannian submanifolds for surrogate modeling and uncertainty quantification

In this work we introduce a manifold learning-based surrogate modeling framework for uncertainty quantification in high-dimensional stochastic systems. Our first goal is to perform data mining on the available simulation data to identify a set of low-dimensional (latent) descriptors that efficiently parameterize the response of the high-dimensional computational model. To this end, we employ Principal Geodesic Analysis on the Grassmann manifold of the response to identify a set of disjoint principal geodesic submanifolds, of possibly different dimension, that captures the variation in the data. Since operations on the Grassmann require the data to be concentrated, we propose an adaptive algorithm based on Riemannian K-means and the minimization of the sample Fréchet variance on the Grassmann manifold to identify “local” principal geodesic submanifolds that represent different system behavior across the parameter space. Polynomial chaos expansion is then used to construct a mapping between the random input parameters and the projection of the response on these local principal geodesic submanifolds. Here, the method is demonstrated on four test cases, a toy-example that involves points on a hypersphere, a Lotka-Volterra dynamical system, a continuous-flow stirred-tank chemical reactor system, and a two-dimensional Rayleigh-Bénard convection problem.

42 ENGINEERING↗

A Pilot Study of Whole-Blood Transcriptomic Analysis to Identify Genes Associated with Repetitive Low-Level Blast Exposure in Career Breachers

Repetitive low-level blast exposure is one of the major occupational health concerns among US military service members and law enforcement. This study seeks to identify gene expression using microRNA and RNA sequencing in whole-blood samples from experienced breachers and unexposed controls. We performed experimental RNA sequencing using Illumina’s HiSeq 2500 Sequencing System, and microRNA analysis using NanoString Technology nCounter miRNA expression panel in whole-blood total RNA samples from 15 experienced breachers and 14 age-, sex-, and race-matched unexposed controls. We identified 10 significantly dysregulated genes between experienced breachers and unexposed controls, with FDR corrected <0.05: One upregulated gene, LINC00996 (long intergenic non-protein coding RNA 996); and nine downregulated genes, IGLV3-16 (immunoglobulin lambda variable 3-16), CD200 (CD200 molecule), LILRB5 (leukocyte immunoglobulin-like receptor B5), ZNF667-AS1 (ZNF667 antisense RNA 1), LMOD1 (leiomodin 1), CNTNAP2 (contactin-associated protein 2), EVPL (envoplakin), DPF3 (double PHD fingers 3), and IGHV4-34 (immunoglobulin heavy variable 4-34). The dysregulated gene expressions reported here have been associated with chronic inflammation and immune response, suggesting that these pathways may relate to the risk of lasting neurological symptoms following high exposures to blast over a career.

59 BASIC BIOLOGICAL SCIENCES↗

The ASAS-SN bright supernova catalogue – V. 2018–2020

We catalogue the 443 bright supernovae (SNe) discovered by the All-Sky Automated Survey for Supernovae (ASAS-SN) in 2018−2020 along with the 519 SNe recovered by ASAS-SN and 516 additional m peak ≤ 18 mag SNe missed by ASAS-SN. Our statistical analysis focuses primarily on the 984 SNe discovered or recovered in ASAS-SN g-band observations. The complete sample of 2427 ASAS-SN SNe includes earlier V-band samples and unrecovered SNe. For each SN, we identify the host galaxy, its UV to mid-IR photometry, and the SN’s offset from the centre of the host. Updated peak magnitudes, redshifts, spectral classifications, and host galaxy identifications supersede earlier results. With the increase of the limiting magnitude to g ≤ 18 mag, the ASAS-SN sample is nearly complete up to m peak = 16.7 mag and is 90 per cent complete for m peak ≤ 17.0 mag. This is an increase from the V-band sample, where it was roughly complete up to m peak = 16.2 mag and 70 per cent complete for m peak ≤ 17.0 mag.

79 ASTRONOMY AND ASTROPHYSICS↗

A Spectroscopic Study of Mars-analog Materials with Amorphous Sulfate and Chloride Phases: Implications for Detecting Amorphous Materials on the Martian Surface

The Chemistry and Mineralogy X-ray diffraction (XRD) instrument aboard the Curiosity rover consistently identifies amorphous material at Gale Crater, which is compositionally variable, but often includes elevated sulfur and iron, suggesting that amorphous ferric sulfate (AFS) may be present. Understanding how desiccating ferric sulfate brines affect the spectra of Martian material analogs is necessary for interpreting complex/realistic reaction assemblages. Visible and near-infrared reflectance (VNIR), mid-infrared attenuated total reflectance (MIR, FTIR-ATR), and Raman spectra, along with XRD data are presented for basaltic glass, hematite, gypsum, nontronite, and magnesite, each at three grain sizes (<25, 25–63, and 63–180 μm), mixed with ferric sulfate (+/–NaCl), deliquesced, then rapidly desiccated in 11% relative humidity or via vacuum. All desiccated products are partially or completely XRD amorphous; crystalline phases include starting materials and trace precipitates, leaving the bulk of the ferric sulfate in the amorphous fraction. Due to considerable spectral masking, AFS detectability is highly dependent on spectroscopic technique and minerals present. This has strong implications for remote and in situ observations of Martian samples that include an amorphous component. AFS is only identifiable in VNIR spectra for magnesite, nontronite, and gypsum samples; hematite and basaltic glass samples appear similar to pure materials. Sulfate features dominate Raman spectra for nontronite and basaltic glass samples; the analog material dominates Raman spectra of hematite and gypsum samples. MIR data are least affected by masking, but basaltic glass is almost undetectable in MIR spectra of those mixtures. NaCl produces similar FTIR-ATR and Raman features, regardless of analog material.

58 GEOSCIENCES↗