Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Effect of Pressure on Trace Element Activity Coefficients in Metal-Silicate Systems

The partitioning of trace elements between metal and silicate melts serves as the foundation for understanding the differentiation of a planetary body into a metallic core and silicate mantle. Element activity influences metal-silicate partitioning behavior. Activity coefficients are directly dependent on composition and temperature, and can be indirectly dependent on oxygen fugacity and pressure. Distinguishing the effect of pressure from other variables on the activity coefficients and partitioning is important for understanding the chemical evolution of different planetary bodies during differentiation. In this study, we investigated the influence of pressure on the activity coefficients of Cu, Mo, Pd, Pt, As, Sb, and Bi in Fe-Si metallic liquids. All of these elements exhibit moderate to high activity coefficients in Fe-Si liquids at low pressure, which significantly controls their metal-silicate partitioning behavior. Identifying whether this strong dependence persists at higher pressures is critical to modeling and understanding the chemical consequences of core formation. New experiments at 10 GPa were used to derive activity coefficients for these metals which can be compared to activity coefficients determined at 1 GPa. Experiments were conducted at 10 GPa and 2373K using a 10/5 assembly in the 880-ton multi-anvil press at NASA Johnson Space Center. The standard 10/5 COMPRES assembly was slightly modified to accommodate a sample capsule machined from single-crystal MgO that minimizes melt percolation out of the sample volume during the experiment. Experiment starting materials were comprised of 70 wt.% Knippa basalt and 30 wt.% metal. The metal mixture (~85 wt.% Fe) was created by adding the elements of interest (Cu, Mo, Pd, Pt, As, Sb, Bi) to Fe metal powder. Varied amounts of Si metal (0-10 wt.% Si) were added to the metal-silicate mixtures to generate a systematic series of starting materials. For each element, an epsilon interaction parameter in Fe-Si liquid was derived from the results of our 0-10 wt.% Si metal series. To investigate whether pressure influences the trace element activity coefficients in the 1-10 GPa pressure range, we compared our results at 10 GPa to those at 1-4 GPa [1-3]. Our results can also be directly compared to interaction parameters for Au, P, V, Mn, Ga, Zn, Cd, Sn, W, Pb, and Nb previously determined at 10 GPa and 2373K following the same methods [4]. Combined, this suite of interaction parameters will directly inform metal-silicate partitioning between 1 and 10 GPa, and assess whether these values can be extrapolated to modeling differentiation processes at pressures >10 GPa.

Kelsey Prissel↗

Effect of Pressure and Oxidation State on Pnictogen Metal-Silicate Partitioning

The partitioning of trace elements between metal and silicate melts serves as the foundation for understanding the differentiation of a planetary body into a metallic core and silicate mantle. Element activity influences metal-silicate partitioning behavior. Activity coefficients are directly dependent on composition and temperature, and can be indirectly dependent on oxygen fugacity and pressure. Distinguishing the effect of pressure from other variables on the activity coefficients and partitioning is important for understanding the chemical evolution of different planetary bodies during differentiation. In this study, we investigated the influence of pressure on the activity coefficients of Cu, Mo, Pd, Pt, As, Sb, and Bi in Fe-Si metallic liquids. All of these elements exhibit moderate to high activity coefficients in Fe-Si liquids at low pressure, which significantly controls their metal-silicate partitioning behavior. Identifying whether this strong dependence persists at higher pressures is critical to modeling and understanding the chemical consequences of core formation. New experiments at 10 GPa were used to derive activity coefficients for these metals which can be compared to activity coefficients determined at 1 GPa. Experiments were conducted at 10 GPa and 2373K using a 10/5 assembly in the 880-ton multi anvil press at NASA Johnson Space Center. The standard 10/5 COMPRES assembly was slightly modified to accommodate a sample capsule machined from single-crystal MgO that minimizes melt percolation out of the sample volume during the experiment. Experiment starting materials were comprised of 70 wt.% Knippa basalt and 30 wt.% metal. The metal mixture (~85 wt.% Fe) was created by adding the elements of interest (Cu, Mo, Pd, Pt, As, Sb, Bi) to Fe metal powder. Varied amounts of Si metal (0-10 wt.% Si) were added to the metal-silicate mixtures to generate a systematic series of starting materials. For each element, an epsilon interaction parameter in Fe-Si liquid was derived from the results of our 0-10 wt.% Si metal series. To investigate whether pressure influences the trace element activity coefficients in the 1-10 GPa pressure range, we compared our results at 10 GPa to those at 1-4 GPa [1-3]. Our results can also be directly compared to interaction parameters for Au, P, V, Mn, Ga, Zn, Cd, Sn, W, Pb, and Nb previously determined at 10 GPa and 2373K following the same methods [4]. Combined, this suite of interaction parameters will directly inform metal- silicate partitioning between 1 and 10 GPa, and assess whether these values can be extrapolated to modeling differentiation processes at pressures >10 GPa. [1] Righter et al. (2018) GCA 232, 101-123 [2] Righter et al. (2019) MaPS 54, 1379-1394 [3] Steenstra et al. (2020) Icarus, 335, 113391 [4] Righter et al. (2020) Geochem. Persp. Let. 15, 44-49

Kelsey Prissel↗

Assessment of measurement error due to sampling perspective in the space-based Doppler lidar wind profiler

A Multipair Algorithm (MPA) has been developed to minimize the contribution of the sampling error in the simulated Doppler lidar wind profiler measurements (due to angular and spatial separation between shots in a shot pair) to the total measurement uncertainty. Idealized wind fields are used as input to the profiling model, and radial wind estimates are passed through the MPA to yield a wind measurement for 300 x 300 sq km areas. The derived divergence fields illustrate the gradient patterns that are particular to the Doppler lidar sampling strategy and perspective.

Houston, S. H.↗

Binomial Test Method for Determining Probability of Detection Capability for Fracture Critical Applications

The capability of an inspection system is established by applications of various methodologies to determine the probability of detection (POD). One accepted metric of an adequate inspection system is that for a minimum flaw size and all greater flaw sizes, there is 0.90 probability of detection with 95% confidence (90/95 POD). Directed design of experiments for probability of detection (DOEPOD) has been developed to provide an efficient and accurate methodology that yields estimates of POD and confidence bounds for both Hit-Miss or signal amplitude testing, where signal amplitudes are reduced to Hit-Miss by using a signal threshold Directed DOEPOD uses a nonparametric approach for the analysis or inspection data that does require any assumptions about the particular functional form of a POD function. The DOEPOD procedure identifies, for a given sample set whether or not the minimum requirement of 0.90 probability of detection with 95% confidence is demonstrated for a minimum flaw size and for all greater flaw sizes (90/95 POD). The DOEPOD procedures are sequentially executed in order to minimize the number of samples needed to demonstrate that there is a 90/95 POD lower confidence bound at a given flaw size and that the POD is monotonic for flaw sizes exceeding that 90/95 POD flaw size. The conservativeness of the DOEPOD methodology results is discussed. Validated guidelines for binomial estimation of POD for fracture critical inspection are established.

Generazio, Edward R.↗

Toward high-resolution NMR spectroscopy of microscopic liquid samples

A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Lithium Ion Battery Materials with Valence Electron Energy-Loss Spectroscopy

Abstract Cutting-edge research on materials for lithium ion batteries regularly focuses on nanoscale and atomic-scale phenomena. Electron energy-loss spectroscopy (EELS) is one of the most powerful ways of characterizing composition and aspects of the electronic structure of battery materials, particularly lithium and the transition metal mixed oxides found in the electrodes. However, the characteristic EELS signal from battery materials is challenging to analyze when there is strong overlap of spectral features, poor signal-to-background ratios, or thicker and uneven sample areas. A potential alternative or complementary approach comes from utilizing the valence EELS features (<20 eV loss) of battery materials. For example, the valence EELS features in LiCoO 2 maintain higher jump ratios than the Li–K edge, most notably when spectra are collected with minimal acquisition times or from thick sample regions. EELS maps of these valence features give comparable results to the Li–K edge EELS maps of LiCoO 2 . With some spectral processing, the valence EELS maps more accurately highlight the morphology and distribution of LiCoO 2 than the Li–K edge maps, especially in thicker sample regions. This approach is beneficial for cases where sample thickness or beam sensitivity limit EELS analysis, and could be used to minimize electron dosage and sample damage or contamination.

energy storage (including batteries and capacitors↗

WHONDRS River Corridor Surface Water Metabolites and Geochemistry from Global Sites

This dataset supports a broader study examining the character of organic matter that may be delivered to subsurface sediments via hydrologic exchange. To implement the global survey, free stream sampling kits were provided to interested volunteers throughout the world. Samples were collected with minimal constraints in terms of location, but following strict protocols, and shipped for metabolomic analysis via Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). In addition, basic geochemistry analyses (e.g., dissolved organic matter concentration) were conducted, standardized photos of each field system were taken, and extensive metadata were captured. Sampling began in 2018 and is ongoing as of 2025. This dataset is comprised of one folders of field photos, one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data, and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) international generic sample number (IGSN) mapping file; (6) field protocol; and (7) a subfolder with sample data. The sample data subfolder contains (1) surface water dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) methods codes; (3) surface water FTICR methods; and (4) a subfolder of 12 Tesla (12T) FTICR-MS data. This folder contains three subfolders, one containing the.xml files, one containing the CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, or .png. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About.

Biogeochemistry↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymatic saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.

09 BIOMASS FUELS↗

Development of Ion Mobility Spectrometry for Exobiology Flight Experiments

Ion Mobility Spectrometry (IMS) can provide gas chromatography with sample identification independent of sample retention time, with minimal interface. Initial commercial methods of IMS however, did not possess sufficient analytical capabilities and presented operational parameters which were unsuitable for exobiology missions. Subsequent development of IMS technology, with the focus on exobiology analytical requirements and mission imposed operational limitations, has produced an IMS interfaced with a GC capable of fulfilling the analytical requirements of several exobiology missions. Future exobiology missions will require further development of the IMS, particularly in the areas of overall instrument miniaturization and complex sample identification. The evolution of the exobiology focused IMS will be presented up to the current prototype design, which is a component of several proposed exobiology instruments. Areas of future development will also be discussed.

Kojiro, Daniel R.↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Manifold Sampling for Optimization of Nonconvex Functions That Are Piecewise Linear Compositions of Smooth Components

Here, we develop a manifold sampling algorithm for the minimization of a nonsmooth composite function $f \triangleq \psi + h \circ F$ when $\psi$ is smooth with known derivatives, $h$ is a known, nonsmooth, piecewise linear function, and $F$ is smooth but expensive to evaluate. The trust-region algorithm classifies points in the domain of $h$ as belonging to different manifolds and uses this knowledge when computing search directions. Since $h$ is known, classifying objective manifolds using only the values of $F$ is simple. We prove that all cluster points of the sequence of the manifold sampling algorithm iterates are Clarke stationary; this holds although points evaluated by the algorithm are not assumed to be differentiable and when only approximate derivatives of $F$ are available. Numerical results show that manifold sampling using zeroth-order information about $F$ is competitive with algorithms that employ exact subgradient values from $\partial f$.

97 MATHEMATICS AND COMPUTING↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

AERACEPT (AErosol Rapid Analysis Combined Entry Probe/sonde Technology) for the Nephele Venus Cloud Mission Concept

Nephele is a small atmospheric probe mission concept to determine whether the Venus clouds contain organic matter. Nephele complements larger missions that seek to conduct Venus atmospheric analyses, such as DAVINCI, Venera-D, and the Morning Star missions, by directly sampling and analyzing cloud and haze particles. AERACEPT is an aerosol sampling technology designed to minimize the mass, volume, and complexity required for in situ planetary atmosphere characterization. A single aeroshell functions as a combined entry vehicle, descent probe, and instrumented sonde, combining recent advances in thermal protection materials with heritage technology from planetary and airborne science. The velocity of descent drives aerosol through inlets embedded in the aeroshell’s thermal protection material; inertial separation isolates the particles from the gas stream; and the particle capture surface doubles as the analysis substrate. This method can work without heat shield separation, descent control, or active sample handling; these advantages trade against a smaller sample volume, higher risk of sample heating, and shorter time for analysis and data return. AERACEPT further benefits from modeling of the internal and external flow to understand the particle capture efficiency and bias for size and concentration distributions. AERACEPT is well suited for a Venus mission such as Nephele, where a passive descent trajectory is both subsonic over the altitudes of interest and provides sufficient velocity and pressure differential for the particle sizes of interest. A thermal and flow toolchain developed in-house (Traj→ DPLR→ PATO→ openFOAM) was used to model an 80-cm aeroshell with science operations 63–39 km. These models indicate that AERACEPT will provide ~24 µL accumulated sample of particles ≥ 0.2 µm, substantially above the 2 µL threshold requirement. The worst-case particle heating will be ~14 K above ambient, for the smallest particles at the lowest altitude; most particles will experience ≤ 1 K rise, at which almost all analytes of interest will be unaffected. Plasma jet testing of a small-scale aeroshell-material inlet was recently conducted to validate the thermal model parameters; wind tunnel testing to validate the flow model parameters is underway.

AERACEPT↗

Sample Return Container Opening Process Concept for Potential Mars Sample Return

Proposed Mars Sample Return (MSR) missions would require a pristine and secure opening method to ensure sample Contamination Control and backward Planetary Protection. In order to reach the samples, a series of five containers would need to be opened inside of a Mars Returned Sample Handling (MRSH) facility. The process would include opening the Containment Assurance Module (CAM) aboard the Earth Entry Vehicle (EEV), the Secondary Containment Vessel (SCV), Primary Containment Vessel (PCV), and the Orbiting Sample (OS) container, and finally removing and opening the Returned Sample Tube Assemblies (RSTA). Some of these containers can be opened by reversing the mechanical assembly process while others would require destructive means. Several containers are still in a conceptual design phase while others are en route to Mars aboard the M2020 rover. In order to inform the design of the containers that are still in the conceptual stages, a study was performed at each level of the containment assembly. The studies were used to determine the least destructive and most robust methods to disassemble and open the containers while minimizing risk to the samples or the personnel. In addition to the envisioned disassembly and breaching method, contingency plans were made for completing the disassembly if damage to the vehicle and containment system occurred.

Liu, Yang↗

Exponentially-Biased Ground-State Sampling of Quantum Annealing Machines with Transverse-Field Driving Hamiltonians

We study the performance of the D-Wave 2X quantum annealing machine on systems with well-controlled ground-state degeneracy. While obtaining the ground state of a spin-glass benchmark instance represents a difficult task, the gold standard for any optimization algorithm or machine is to sample all solutions that minimize the Hamiltonian with more or less equal probability. Our results show that while naive transverse-field quantum annealing on the D-Wave 2X device can find the ground-state energy of the problems, it is not well suited in identifying all degenerate ground-state configurations associated to a particular instance. Even worse, some states are exponentially suppressed, in agreement with previous studies on toy model problems [New J. Phys. 11, 073021 (2009)]. These results suggest that more complex driving Hamiltonians are needed in future quantum annealing machines to ensure a fair sampling of the ground-state manifold.

Quantum Annealing↗

A microfluidic flow-cell for the study of the ultrafast dynamics of biological systems

The study of biochemical dynamics by ultrafast spectroscopic methods is often restricted by the limited amount of liquid sample available, while the high repetition rate of light sources can induce photodamage. In order to overcome these limitations, we designed a high flux, sub-ml, capillary flow-cell. While the 0.1 mm thin window of the 0.5 mm cross-section capillary ensures an optimal temporal resolution and a steady beam deviation, the cell-pump generates flows up to ~0.35 ml/s that are suitable to pump laser repetition rates up to ~14 kHz, assuming a focal spot-diameter of 100 μm. In addition, a decantation chamber efficiently removes bubbles and allows, via septum, for the addition of chemicals while preserving the closed atmosphere. The minimal useable amount of sample is ~250 μl.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microbial assessment of cabin air quality on commercial airliners

The microbial burdens of 69 cabin air samples collected from commercial airliners were assessed via conventional culture-dependent, and molecular-based microbial enumeration assays. Cabin air samples from each of four separate flights aboard two different carriers were collected via air-impingement. Microbial enumeration techniques targeting DNA, ATP, and endotoxin were employed to estimate total microbial burden. The total viable microbial population ranged from 0 to 3.6 x10 4 cells per 100 liters of air, as assessed by the ATP-assay. When these same samples were plated on R2A minimal medium, anywhere from 2% to 80% of these viable populations were cultivable. Five of the 29 samples examined exhibited higher cultivable counts than ATP derived viable counts, perhaps a consequence of the dormant nature (and thus lower concentration of intracellular ATP) of cells inhabiting these air cabin samples. Ribosomal RNA gene sequence analysis showed these samples to consist of a moderately diverse group of bacteria, including human pathogens. Enumeration of ribosomal genes via quantitative-PCR indicated that population densities ranged from 5 x 10 1 ' to IO 7 cells per 100 liters of air. Each of the aforementioned strategies for assessing overall microbial burden has its strengths and weaknesses; this publication serves as a testament to the power of their use in concert.

microbe↗