Search NASA⌕ Search

SEARCH · Search NASA

Results for “simultaneous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Ozone concentration in the cabin of a Gates Learjet measured simultaneously with atmospheric ozone concentrations

A Gates Learjet Model 23 was instrumented with monitors to measure simultaneously the atmospheric and the cabin concentrations of ozone at altitudes up to 13 kilometers. Six data flights were made in February 1978. Results indicated that only a small amount of the atmospheric ozone is destroyed in the cabin pressurization system. Ozone concentrations measured in the cabin near the conditioned-air outlets were only slightly lower than the atmospheric ozone concentration. For the two cabin configurations tested, the ozone retention in the cabin was 63 and 41 percent of the atmospheric ozone concentration. Maximum cabin ozone concentration measured during these flights was 410 parts per billion by volume.

Briehl, D.↗

Simultaneous determination of rotational and translational temperatures of OH/2 Pi/ in a gas discharge

A simultaneous determination of the rotational and translational temperatures of OH(2 Pi) in a water-vapor discharge is reported. These temperatures were determined by measuring the strength and line shape of the absorption lines in the 2 Pi (v = 0) - 2 Sigma(+) (v = 0) transitions of OH using a CW tunable laser. It was found that the rotational distribution was thermalized, but the corresponding rotational temperature was much lower than the translational temperature. Possible implications of these results are discussed.

Wang, C. C.↗

Prospects for detection of gravitational radiation by simultaneous Doppler tracking of several spacecraft

This paper reports a calculation of the effect of gravitational radiation on the observed Doppler shift of a sinusoidal electromagnetic signal transmitted to, and coherently transponded from, distant spacecraft. It is found that the effect of plane gravitational waves on such observations is not intuitively immediate, and in fact depends sensitively on the spacecraft direction, which suggests the possibility of detecting such plane waves by simultaneous Doppler tracking of several spacecraft. The need for broad band gravitational wave observations, the required stabilities of time keeping standards, and astrophysical sources expected in the Very Low Frequency band are briefly discussed.

Estabrook, F. B.↗

Geomagnetic pulsations observed simultaneously on three geostationary satellites

Simultaneous observations of magnetic pulsations have been made by three geostationary satellites carrying similar magnetometers and acting as an azimuthal array. Autospectral and cross-spectral analysis yields coherence and phase differences between the pulsations at the satellite positions. The majority of the data fit the Kelvin-Helmholtz generation mechanism. The azimuthal wave number changes sign near noon and corresponds to propagation away from noon. Usually, the wave number is less than 10 deg per degree of longitude. Later in the afternoon, however, strong pulsations are observed with low coherence, implying large wave numbers. This suggests an instability driven by a gradient in the intensity of energetic protons, which may be expected at this local time. The data also suggest that some of the observed phase difference between the azimuthal components is due to small separations in magnetic shell, whereas this is not the case for the radial components. This implies a localized field-line resonance.

Hughes, W. J.↗

Simultaneous observations of equatorial ionospheric scintillation on four frequencies

The variation with frequency of ionospheric scintillations, simultaneously observed at 40, 140, 360, and 860 MHz at equatorial latitudes, was studied. The ATS 6 geostationary satellite was equipped with radio beacons at 40, 140, and 360 MHz, and also with a television downlink at 860 MHz. The signals were recorded at Ootacamund, India (dip 4 deg N) and were most common between 2000 and 2300 LT. It was found that the spectral index of an expression used by Aarons et al (1967) was not constant but decreased with increasing magnitude of scintillations. For weak scintillations the spectral index (referred to as the exponent) was found to be close to 1.0. The analysis of the records involved scaling at 15-sec intervals and the calculation of the average scintillation index.

Rastogi, R. G.↗

First comparison of simultaneous IRIS, BUV, and ground-based measurements of total ozone

In the present paper, the zonally-averaged global distribution of total ozone obtained simultaneously from different measurements are compared with respect to differences in the measured latitudinal and seasonal variations of total ozone. Emphasis is placed on systematic discrepancies that appear to be related to differences in the sensing methodologies or instruments. While the zonal averages of the IRIS and BUV satellite techniques agree quite well at low latitudes, the results are consistently higher for IRIS than for BUV above mid-latitudes in both the Northern and Southern Hemispheres. The BUV and ground-based ultraviolet averages agree better with each other than with infrared IRIS measurements.

Prior, E. J.↗

Spectrophotometric variability in the Be star Gamma Cassiopeiae - Simultaneous ultraviolet and H-alpha observations

Simultaneous scans of the ultraviolet Si IV and Mg II resonance doublets in the spectrum of Gamma Cas with the Copernicus satellite during 64 continuous hours of observation, and H-alpha scans from a ground station, are described. No evidence is found for a rotation period of Gamma Cas, but narrow emission components in both ultraviolet doublets are reported along with a sudden emission increase on January 29.1, 1977 UT which appeared to be present in both H-alpha and the ultraviolet lines.

Slettebak, A.↗

Simultaneous stack-gas scrubbing and waste water treatment

Simultaneous treatment of wastewater and S02-laden stack gas make both treatments more efficient and economical. According to results of preliminary tests, solution generated by stack gas scrubbing cycle reduces bacterial content of wastewater. Both processess benefit by sharing concentrations of iron.

Poradek, J. C.↗

Simultaneous treatment of SO2 containing stack gases and waste water

A process for simultaneously removing sulfur dioxide from stack gases and the like and purifying waste water such as derived from domestic sewage is described. A portion of the gas stream and a portion of the waste water, the latter containing dissolved iron and having an acidic pH, are contacted in a closed loop gas-liquid scrubbing zone to effect absorption of the sulfur dioxide into the waste water. A second portion of the gas stream and a second portion of the waste water are controlled in an open loop gas-liquid scrubbing zone. The second portion of the waste water contains a lesser amount of iron than the first portion of the waste water. Contacting in the openloop scrubbing zone is sufficient to acidify the waste water which is then treated to remove solids originally present.

Poradek, J. C.↗

Evaluation of a Wake Vortex Upset Model Based on Simultaneous Measurements of Wake Velocities and Probe-Aircraft Accelerations

Simultaneous measurements were made of the upset responses experienced and the wake velocities encountered by an instrumented Learjet probe aircraft behind a Boeing 747 vortex-generating aircraft. The vortex-induced angular accelerations experienced could be predicted within 30% by a mathematical upset response model when the characteristics of the wake were well represented by the vortex model. The vortex model used in the present study adequately represented the wake flow field when the vortices dissipated symmetrically and only one vortex pair existed in the wake.

Short, B. J.↗

Interactions of simultaneous perturbations of stratospheric photochemistry

The combined effects of two specific ozone perturbation mechanisms are examined. The need to look back to predictions of the near past as well as the future as a means of testing model results is emphasized. The two perturbations examined are that due to chlorofluoromethane (CFM) release and that due to the air pollutants CO and nitrogen oxide. A steady-state model is used to investigate the characteristics of the stratospheric-tropospheric photochemical system for differing levels of CO and nitrogen oxide fluxes at the ground and for simultaneously changing the stratospheric from CFM release. Two basic scenarios chosen to illustrate the competing effects of the two types of perturbation use the time-dependence for chlorine radical buildup calculated for constant continued release of CFM's.

Butler, D. M.↗

Simultaneous visible and ultraviolet spectroscopy of stellar wind variability in Zeta Puppis

Spectra of He II 4686 A and H-alpha in Zeta Pup were obtained simultaneously with Copernicus ultraviolet scans of several P Cygni profiles in this O4 If supergiant with strong mass loss. The visible-wavelength data show significant variations in the profiles of both lines, consisting of doubling of the emission over times of less than a day. Recent theoretical calculations show that the observed profile variations in 4686 A can be produced by significant fluctuations in the wind density. The Copernicus data show less variability, although in one scan of the 1400-A Si IV doublet there appears to be a significant enhancement of the emission which may be correlated with one of the doublings observed in 4686 A and H-alpha, as though a density enhancement formed at low levels and then moved outward in the wind.

Wegner, G. A.↗

The simultaneous inference of stratospheric trace gases with overlapping spectral signatures using limb sounding radiometry

An inversion algorithm has been developed to simultaneously infer the concentrations of two gases with overlapping spectral signatures using limb emission measurements. The algorithm is efficient and provides a solution in two or three iterations. It has been applied in a simulation study to the inference of stratospheric NO2-H2O and HNO3-CF2Cl2. Existing satellite instrumentation was the basis for errors used in the calculations. It is estimated that concentrations of all four gases can be determined with errors of about 20 percent. This assumes an estimated 1980 CF2Cl2 level. Also, other error sources due to contaminant gas, aerosol emission, and the temperature profile must be included to obtain a better estimate of experimental accuracies.

Russell, J. M., III↗

The height variation of supergranular velocity fields determined from simultaneous OSO 8 satellite and ground-based observations

Results are reported for simultaneous satellite and ground-based observations of supergranular velocities in the sun, which were made using a UV spectrometer aboard OSO 8 and a diode-array instrument operating at the exit slit of an echelle spectrograph attached to a vacuum tower telescope. Observations of the steady Doppler velocities seen toward the limb in the middle chromosphere and the photosphere are compared; the observed spectral lines of Si II at 1817 A and Fe I at 5576 A are found to differ in height of formation by about 1400 km. The results show that supergranular motions are able to penetrate at least 11 density scale heights into the middle chromosphere, that the patterns of motion correlate well with the cellular structure seen in the photosphere, and that the motion increases from about 800 m/s in the photosphere to at least 3000 m/s in the middle chromosphere. These observations imply that supergranular velocities should be evident in the transition region and that strong horizontal shear layers in supergranulation should produce turbulence and internal gravity waves.

November, L. J.↗

Infrared measurements of stratospheric composition. II - Simultaneous NO and NO2 measurements

A further flight of the balloon-borne pressure-modulated radiometer (PMR) instrument (Chaloner et al., 1978) is described when simultaneous measurements of NO and NO2 concentrations were made through dawn. A detailed description of the retrieval methods used and the precautions taken against interference from signals from the other gases is given. Profiles of NO(x) through dawn are also briefly considered

Drummond, J. R.↗

Simultaneous measurements of ozone outside and inside cabins of two B-747 airliners and a Gates Learjet business jet

Recently, passengers and crew members on long-distance commercial flights have filed complaints after suffering symptoms of ozone sickness. Studies were conducted to determine the frequency and concentration of ozone in commercial jet transports. The airliner problem with ozone prompted NASA to determine the ozone concentrations that might be encountered in the cabin of a small business jet. Simultaneous measurements of atmospheric ozone levels and ozone levels in the cabins of jet aircraft were necessary because of the wide and rapid variability of atmospheric ozone in flight. It was found that the atmospheric ozone concentrations in the case of B-747 airliners vary widely during a flight. A constant difference, or ratio, between ozone concentrations outside and inside the cabin does not exist.

Perkins, P. J.↗

Simultaneous radio and X-ray observations of the X-ray burst source MXB 1636-53

On June 17, 1977, the X-ray burst source MXB 1636-53 was simultaneously monitored for about 4 hr with the Parkes 64-m radio telescope at a frequency of 14.7 GHz and the SAS 3 X-ray satellite (1.3-12 keV). One X-ray burst was observed; an upper limit (2 sigmas) of 200 mJy is reported for any radio burst coincident with the X-ray event. During the X-ray burst the radio/X-ray time-integrated flux ratio was no more than 375 with a 90 percent confidence. An upper limit (2 sigmas) of 22 mJy was determined for any steady 14.7-GHz source coincident with the X-ray position.

Thomas, R. M.↗