REopt Lite Tutorial: Entering Site Data
This tutorial gives an overview of the financial modeling analysis inputs in the REopt Lite™ web tool.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This tutorial gives an overview of the financial modeling analysis inputs in the REopt Lite™ web tool.
To characterize tidal current and turbulence at a top tidal energy site off the East Foreland in Cook Inlet, Alaska, United States, three moorings were deployed for two months between July and August 2021, and a transect survey was conducted over the course of two tidal cycles at the end of the deployment period. Measurements of velocity and turbulence were then analyzed to better understand the site's hydrodynamics and power potential. Analysis reveals that swift, north-flowing flood currents peak at 4~m/s, while south-flowing ebb currents reach just over 3~m/s. Turbulence intensity ranges from 23\% at the seafloor to 8\% near the surface, and the presence of the foreland creates more intense turbulence near-shore during ebb tide than flood. Power availability at the site could be as high as 720~MW, or 13~kW/m$^2$, though the energy available to a marine energy device will be smaller than this estimate because of water-to-wire efficiency and wake losses. The results from this measurement campaign will inform the validation of a high-resolution tidal hydrodynamic model, as well as early tidal energy projects that are beginning to move beyond the prototyping and demonstration stages to full-scale deployments.
This user’s manual describes version 1.0 of the SHASTA-HELP (Subsurface Hydrogen Assessment, Storage, and Technology Acceleration (SHASTA) - Hydrogen Estimator for Logistical Planning (HELP)) tool and provides instructions for use. The purpose of the SHASTA-HELP tool is to integrate the suite of tools developed by the SHASTA research team in a web-based framework for ease of access and more advanced, integrated analysis. This tool contains functionality for estimating the storage potential of pure and blended natural gas-hydrogen mixtures in various subsurface formations and is intended to be used for pre-characterization or site screening purposes. Detailed storage analysis should be conducted by full reservoir simulation models.
There is an urgent need for adaptative engineering towards more resilient coastal communities, and Coastal Structure Integrated Wave Energy Converters (CSI-WECs) are a promising solution. CSI-WECs are wave energy converters (WECs) that are built into coastal protection structures, such as breakwaters. These devices provide the dual benefits of coastal protection and local energy production, and unlike other WECs, maximizing energy production is not always the main objective. CSI-WECs are located near the shore, where the wave resource is lower, thus site selection for these devices differs from the typical offshore WECs. Other attributes of a site that may be more important than wave power include existing coastal structures, port proximity, electric transmission line proximity, and location of disadvantaged communities. Geospatial information systems (GIS) interfaces can be used to easily visualize geospatial data that represents these difference kinds of criteria important for the determination of optimal marine energy sites. Multi-Criteria Decision Analysis (MCDA) is a geospatial analysis method that allows for the evaluation of multiple, usually overlapping, criteria. This project applies GIS-based MCDA methods to two distinct case studies in Puerto Rico and California for CSI-WEC site selection. The two study sites contrast in terms of wave resource, coastal hazards, and local energy needs. This research demonstrates the utility of applying an MCDA framework within GIS to facilitate efficient site selection for devices with unique characteristics in different use cases.
In this work, we present a site-specific three-dimensional analysis of porosity evolution in neutron-irradiated U–10Zr metallic fuel using high-resolution synchrotron X-ray tomography. Focused ion beam cubic lift-outs from four radial positions—fuel center, middle, edge, and fuel-cladding interaction (FCCI) zones—were imaged, reconstructed, and segmented to quantify pore volume, density, morphology, and pore connectivity. Porosity increased modestly from 5.5% at the center to 10.5% at the edge, yet pore number density increased by over two orders of magnitude in the fuel portion near the FCCI interface (from 4.8 x 10 4 to 6.0 x 10 6 pores/mm 3 ). Morphological classification revealed a progression from small spherical pores at the center to equiaxed and tortuous networks at the periphery, with enhanced orientation along the radial direction. Connectivity and permeability analysis reveal that the FCCI region maintains dense, highly interconnected pores despite a moderate volume fraction, enabling rapid fission gas transport and lanthanide migration. Effective thermal conductivity models incorporating sodium logging confirm that these site-specific pore features critically influenced heat transport during reactor irradiation. These findings demonstrate that pore topology—not just porosity fraction—controls thermal performance and thermal pathways in U–10Zr fuels, impacting fuel thermal performance in a reactor.
This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).
The purpose of this addendum is to amend and update the S300 Roadway Improvements – 817 Complex [project] Soil Sampling and Analysis Plan (SAP) dated May 2023. Field activities to implement the SAP were completed in May 2023 except for SB-17. SB-17 is therefore included in this addendum. In addition, this addendum amends the SAP by covering an expanded scope of work and project limits. The project limits have been expanded to include areas around Building 818. Sampling at the expanded project area is addressed in this addendum by two additional borings for geotechnical and environmental analyses. The project area consists of the access gate and existing access roads for the Process Area complex. Excavation depths are anticipated to be no deeper than 5 feet from current grade. None of the proposed disturbance areas are within known areas of contamination or mapped controlled excavation area (LLNL 2008). Therefore, this addendum proposes a sampling spacing in the vicinity of Building 818 of about 172 feet (Tier 2) in accordance with the Soil Screening and Management Plan (LLNL 2022). The information contained in this addendum supersedes the May 2023 SAP. However, this addendum only addresses elements of the May 2023 SAP that were modified. Elements of the May 2023 SAP that have not been modified are relevant and will remain in effect.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
ABSTRACT Global transcription factors (TFs) control metabolic processes in bacteria to efficiently utilize available carbon. The orderCaldicellulosiruptoraleshas drawn interest due to the ability of its members to degrade components of lignocellulosic biomass. Regulatory reconstruction ofAnaerocellum (f. Caldicellulosiruptor) besciiidentified two major global transcription factors for xylan utilization, XynR and XylR, and the corresponding putative transcription factor binding sites. Recombinant versions of XynR (LacI family) and XylR (ROK family) were subjected to fluorescence polarization (FP) and biolayer interferometry (BLI) analysis to confirm the predicted binding sites. Four XynR sites and two XylR sites were validated, accounting for 20 of 26 genes regulated by XynR and six of seven genes regulated by XylR. Bioinformatic analysis of the individual genes controlled by the two regulators showed an inter-dependent scheme for xylan conversion; the transport of xylooligosaccharides (XOS) is dependent on XylR, while enzymes responsible for hydrolysis are controlled by both regulators. For xylose catabolism by the xylose isomerase-xylulose kinase pathway, regulation is also split, with XylR controlling xylose isomerase and XynR controlling xylokinase. The XynR/XylR regulator pair withinA. besciiis conserved in all sequenced species ofCaldicellulosiruptorales, suggesting similarities in regulating linear xylan conversion. In other xylanolytic thermophiles, XylR homologs control xylan degradation, compared to just 6 out of 26 genes forA. bescii. These results show that two separate regulatory schemes (dual repression) are coordinated byA. besciito effectively regulate the hemicellulose inventory and xylan catabolism. IMPORTANCE To take full advantage of extreme thermophiles as platform metabolic engineering microorganisms, the tools for genetic manipulation must be further developed, and strategies that exploit a better understanding of metabolic regulation need to be discerned.Anaerocellum bescii, the most studied of the extremely thermophilic fermentative anaerobic bacteria that can utilize microcrystalline cellulose, can degrade microcrystalline cellulose and hemicellulose and has been metabolically engineered to convert the resulting sugars to products such as ethanol and acetone. For xylan, in particular, two major global transcription factors (TFs), XynR and XylR, play a role in sugar metabolism, although their predicted regulatory interdependence from bioinformatics analysis has not been elucidated experimentally. Here, fluorescence polarization (FP) and biolayer interferometry (BLI) were used to explore this issue to support metabolic engineering efforts aimed at improving carbohydrate processing to industrial chemicals.
The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.
To achieve national decarbonization goals, U.S. annual deployment of wind energy will need to increase by at least fivefold compared to the recent past. Modeling and analysis frameworks can help inform where and how wind energy deployment might occur and thereby help enable the achievement of decarbonization goals. However, most prior wind energy modeling and analysis studies rely on generalized representations of wind energy technologies. Since wind energy technology advancements are expected to increase the competitiveness of wind energy, it is important to incorporate more detailed representations of turbine technology into wind energy modeling. Here we present a new method that incorporates wind turbine choice into the technology representation of land-based wind energy in long-term planning models. Our method integrates three previously published modeling and analysis capabilities: 1) bottom-up cost modeling to estimate future technology costs, 2) geospatial modeling to represent siting decisions, and 3) power sector modeling to evaluate potential deployment. We refer to this approach as a "customized turbine choice" methodology because it creates a composite turbine scenario by choosing from multiple wind turbine technologies—using site-specific optimized turbine layout and selecting the least-cost technology at each location. We demonstrate the capabilities of this new modeling pipeline by examining how the selection of four different wind turbine configurations might evolve from 2021 through 2040. Our results show that using our customized turbine choice methodology could lead to higher estimates for wind future deployment, which indicates that more simplified modeling might underestimate the role that wind energy could play in meeting decarbonization goals. Future research is needed to further explore the implications of turbine choice and to better inform technology researchers, original equipment manufacturers, and other wind industry stakeholders about the market potential of different wind turbine technologies.
After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.
The aim of this study is generation and validation of a proppant log using analysis of drilling mud returns for child wells. Proppant log provides qualitative as well as quantitative insights into spatial distribution of proppant sand particles from prior stimulation of parent wells. While the basic methodology was developed and formalized during analysis of material collected from through fracture cores at Hydraulic Fracturing Test Site in Midland Basin (HFTS – 1), the test wells at HFTS – 2 in the neighboring Delaware Basin allowed the opportunity to validate the workflow on actual mud return samples from subsurface. As a child well is being drilled, periodic mud return samples are collected at the rig site and preserved for analysis. The workflow involves systematic cleaning of the samples including various steps such as washing, drying and segregation of samples into relevant size fractions of interest (< Mesh 20) based on specifications of pumped sand during stimulation of the parent well. Clean samples are imaged using high resolution transparency scanning. Scan images are then systematically analyzed for particles of interest using computer vision techniques. Sample counts are further validated using elemental analysis of smaller sub-samples at various depths of interest. This step is necessary to isolate proppant versus other naturally occurring minerals such as sulphates and carbonates which show similar optical properties. We successfully correlated proppant distribution against the existing parent well and validated propped versus relatively un-propped zones for a child well at the test site. The advantage of testing the proppant log concept at the HFTS – 2 site is the plethora of additional diagnostic data that is available to validate our primary observations. We can correlate spatial proppant distribution against variability in stimulation response based on independent observations such as image logs, microseismic attributes as well as DAS response, all of which tend to corroborate one another. One of our significant successes was being able to describe varying degrees of impact of the parent well along the lateral length of a stimulated child well. Our workflow represents a systematic and one-of-a-kind interpretation of spatial proppant distribution while drilling child wells. This provides unique opportunities to better understand the current state of the Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R003/2477415/urtec-2021-5189-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5189 2 reservoir being targeted including zones which are likely more drained relative to others and how the planned completion of the child well can be improved. Lastly, this log can be useful is validating optimal well spacing in relatively new fields under development.
Safety is a priority for the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program. This commitment to safety is integrated into requirements and work procedures at DOE sites across the U.S. that generate low-level radioactive waste, mixed low-level radioactive waste, and classified waste that is transported to the Nevada National Security Site (NNSS) for permanent disposal. Generators of this waste are responsible for ensuring it is packaged and transported in a safe and compliant manner. These generators and their contracted commercial carriers must comply with U.S. Department of Transportation (DOT) regulations; the Nevada National Security Site Waste Acceptance Criteria (NNSSWAC); and other applicable federal, state, and local regulations and requirements. This includes packaging and shipping the waste to meet DOT regulatory radiation dose limits to ensure public safety during transportation. NNSS waste generators have a solid safety record for complying with these stringent regulations as demonstrated by the fact that no shipments exceeding DOT dose rate limits were received at the NNSS Area 5 Radioactive Waste Management Complex (RWMC) during FY 2014 through FY 2018. A 2005 study conducted by the Desert Research Institute validated shipments to the NNSS comply with DOT radiation dose limits. In response to recent Nevada stakeholder requests for an updated study, an analysis was conducted to verify and provide evidence that the public continues to be safe from exposure to radioactive waste shipment to the NNSS. Radiation exposure from radioactive waste shipments in transit to the NNSS was evaluated. Three studies were performed: 1. Confirm compliance of waste shipments to the DOT radiation limits using dose rate surveys taken at the generator site and at the disposal site. 2. Estimate the dose to the public from waste shipments using the dosimetry results for disposal site personnel by comparing time of exposure for various individuals/scenarios. 3. Estimate the truck driver dose using the receipt dose rate surveys and time of exposure, and from dosimetry results. Study 1 confirmed compliance with the DOT dose rate limits for a sample of waste shipments (123 of 1,038) received during fiscal year (FY) 2017. Study 2 showed that the average annual radiation equivalent dose for disposal site personnel during FY 2017 was approximately 6.7% [0.415 mSv (41.5 millirem)] of the annual average dose that a person living in the U.S. receives from all sources [6.2 mSv (620 mrem)]. Maximum dose to a member of the public, a person resting/sleeping in an adjacent truck at a rest area to a waste shipment, was 0.0166 mSv (1.66 mrem), which is less than the dose received from a person taking a round trip from the east coast to the west coast of the continental U.S. on an airplane [0.07 mSv (7 mrem) per round trip]. Study 3 showed that the truck driver who made the most shipments of radioactive waste to the NNSS, who drove the most hours (estimated time of exposure 2,520 hours), during FY 2017 had a total dose of 0.15 mSv (15 mrem), which was obtained from their personal dosimeter. The annual dose recorded for disposal site personnel, the dose estimates for the public, and the truck driver dose were all a small percentage of the average radiation dose a person receives from all sources (e.g., background and medical radiation). At these levels, risk should only be described qualitatively. Radiation exposure from radioactive waste shipments to the NNSS were shown to be compliant with the DOT dose rate limits, safe, and very low (i.e., within background levels). (authors)
Non-powered dams represent 97% of dams in the United States and their energy generation potential has not been fully realized. The use of an Archimedes screw turbine to generate power at non-powered dams offers a dual benefit; producing electricity, and acting as downstream fish passage, helping to reconnect previously separated ecosystems. In this study, we assess the technical, environmental, social, and economic feasibility of generating power at non-powered U.S. dam sites using Archimedes screw turbines by integrating mechanical constraints, social impact metrics, proximity to infrastructure, and environmental sensitivity data. Results account for future precipitation predictions and show, between 2024 and 2050, the number of sites where Archimedes screw turbines are viable decreases by one site, but overall generation capacity increases due to increased flow rates across persisting locations. Our analysis identified 82 non-powered dam sites with a mean generation capacity of 49 kW that meet the mechanical requirements for Archimedes screw turbine technology in 2024. Our analysis presents a framework for considering social, environmental, and economic impacts of specific turbine technologies to convert non-powered dams to generate power.
This is a presentation featuring an analysis related to SMART Task 6 in which CO2 storage costs are presented. The National Energy Technology Laboratory has developed the NRAP/SMART Technoeconomic and Liability Evaluation for Storage (TALES) model to provide quantitative cost-based insights to support developers planning CO2 injection and storage projects. TALES calculates the revenues, costs, and financial performance of candidate CO2 saline storage project based on site-specific activity costs and financial parameters. TALES is being integrated as a module pertaining to storage cost as part of the broader SMART Visualization and Decision Support Platform (SVDSP). In this study, the TALES model was applied using real activity cost data associated with the development and operations at the Illinois Basin Decatur Project (IBDP) CO2 storage project site. Scenario analysis was implemented in which crucial operational and cost attributes were varied and the associated cost implications observed. Key results data and project cost summary metrics like first-year breakeven price of CO2 ($/tonne) and net present value (NPV) are presented in similar fashion to how they will appear in the SVDSP.