Search NASA⌕ Search

SEARCH · Search NASA

Results for “small lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗

Interactions between Surface Chemistry and Gas-Phase Combustion: New Optical Tools for Probing Flame-Wall Interactions and the Heterogeneous Chemistry of Soot Growth and Oxidation in Flame. Final report

Some of the most stubborn and technologically critical problems in combustion are dominated by heterogeneous processes. While purely gas-phase combustion systems have been the subject of intense theoretical and experimental study, combustion phenomena occurring at interfaces are far less understood. This is partly caused by the lack of experimental approaches capable of probing locations very close to an interface, especially in the hostile environment of combustion. For laser-based optical techniques, measurements taken near interfaces are often complicated by laser scattering from the surface interfering with relatively weak signals. Further, for measurements intended to probe molecular species adsorbed at the interface between a gas-phase combustion reaction and a condensed phase material, signals are generally overwhelmed by contributions from the bulk phases, causing the small contribution from the interfacial molecular species to be undetectable. Our goal in this project has been to develop new optical tools for imaging chemical species, temperature, and surface species at and near surfaces or interfaces of relevance to combustion. We have placed focus on the development and refinement of ultrafast techniques such as femtosecond coherent Raman imaging and femtosecond/picosecond sum-frequency generation (SFG) scattering, as well as the models used to simulate such spectra under differing conditions of pressure and chemical speciation. The two physical phenomena initially targeted for study in this project were flamewall interactions, and the growth of particulates in flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Temporal Sampling of Enzymes from Live Cells by Localized Electroporation and Quantification of Activity by SAMDI Mass Spectrometry

Abstract Measuring changes in enzymatic activity over time from small numbers of cells remains a significant technical challenge. In this work, a method for sampling the cytoplasm of cells is introduced to extract enzymes and measure their activity at multiple time points. A microfluidic device, termed the live cell analysis device (LCAD), is designed, where cells are cultured in microwell arrays fabricated on polymer membranes containing nanochannels. Localized electroporation of the cells opens transient pores in the cell membrane at the interface with the nanochannels, enabling extraction of enzymes into nanoliter‐volume chambers. In the extraction chambers, the enzymes modify immobilized substrates, and their activity is quantified by self‐assembled monolayers for matrix‐assisted laser desorption/ionization (SAMDI) mass spectrometry. By employing the LCAD‐SAMDI platform, protein delivery into cells is demonstrated. Next, it is shown that enzymes can be extracted, and their activity measured without a loss in viability. Lastly, cells are sampled at multiple time points to study changes in phosphatase activity in response to oxidation by hydrogen peroxide. With this unique sampling device and label‐free assay format, the LCAD with SAMDI enables a powerful new method for monitoring the dynamics of cellular activity from small populations of cells.

Mukherjee, Prithvijit↗

Thermoresponsive polymer assemblies via variable temperature liquid-phase transmission electron microscopy and small angle X-ray scattering

Abstract Herein, phase transitions of a class of thermally-responsive polymers, namely a homopolymer, diblock, and triblock copolymer, were studied to gain mechanistic insight into nanoscale assembly dynamics via variable temperature liquid-cell transmission electron microscopy (VT-LCTEM) correlated with variable temperature small angle X-ray scattering (VT-SAXS). We study thermoresponsive poly(diethylene glycol methyl ether methacrylate) (PDEGMA)-based block copolymers and mitigate sample damage by screening electron flux and solvent conditions during LCTEM and by evaluating polymer survival via post-mortem matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS). Our multimodal approach, utilizing VT-LCTEM with MS validation and VT-SAXS, is generalizable across polymeric systems and can be used to directly image solvated nanoscale structures and thermally-induced transitions. Our strategy of correlating VT-SAXS with VT-LCTEM provided direct insight into transient nanoscale intermediates formed during the thermally-triggered morphological transformation of a PDEGMA-based triblock. Notably, we observed the temperature-triggered formation and slow relaxation of core-shell particles with complex microphase separation in the core by both VT-SAXS and VT-LCTEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bringing weak transitions to light

Abstract Weak transitions between quantum states are of fundamental importance for a broad range of phenomena from analytical biochemistry to precision physics, but generally challenge experimental detection. Due to their small cross sections scaling with the absolute square of their transition matrix elements, spectroscopic measurements often fail in particular in the presence of competing background processes. Here we introduce a general concept to break this scaling law and enhance the transition probability by exploiting a stronger laser-coupled pathway to the same excited state. We demonstrate the concept experimentally by attosecond transient absorption spectroscopy in helium atoms. The quasi-forbidden transitions from the ground state 1s 2 to the weakly coupled doubly excited 2p3dandsp 2,4− states are boosted by an order of magnitude. Enhancing single-photon-suppressed transitions can find widespread applicability, from spectral diagnostics of complex molecules in life and chemical sciences to precision spectroscopy of weak transitions in metastable atomic nuclei in the search for new physics.

Science & Technology - Other Topics↗

Measurements of the electron energy distribution function in partially magnetized low temperature plasmas

While Langmuir probes (LPs) are relatively simple and inexpensive plasma diagnostics for the electron density, temperature, and the electron energy distribution function (EEDF), the interpretation of the measured current–voltage (I–V) characteristic is complicated considerably by the presence of a magnetic field. In regimes where the electron gyroradius is comparable to the probe radius, the electron flux to the probe surface is retarded by reduced mobility across field lines and can no longer be described by a thermal model. Predicting the current collected by the probe in these regimes requires accurate estimates of the plasma diffusion coefficients, which are usually difficult to obtain. In this work, we measure electron energy distribution functions in E×B plasmas with magnetized electrons and non-magnetized ions in argon and krypton gases, using both a LP and laser Thomson scattering (LTS) at various magnetic fields. Using the LTS measurements to provide a robust benchmark for comparison, we compare existing theories describing the flux to the probe under magnetized conditions. We find that even when the electron gyroradius associated with the effective electron temperature is small compared to the probe radius, the EEDF computed using classical probe theory is still robust at energies higher than the energy at which the gyroradius becomes larger than the probe size. For plasmas that are not strongly non-Maxwellian, we formulate a method to extract robust density and temperature measurements using physics-informed fitting techniques to analyze EEDFs computed using classical theory.

Devin, E. G. [Princeton Plasma Physics Laboratory ↗

Measurement of chromatic aberrations using phase retrieval

We explore the feasibility of measuring chromatic aberrations using a technique based on phase retrieval, primarily for the purpose of diagnostics on the OMEGA EP laser. A computational model and optimization strategy is described, issues of numerical efficiency are addressed, and the potential limitations of the method are studied using mathematical analysis and Monte Carlo simulations. As a result, the algorithm performs well in simulation and yields encouraging results in a small-scale laboratory experiment.

97 MATHEMATICS AND COMPUTING↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosing magnetic fields in cylindrical implosions with oblique proton radiography

Two experiments at the OMEGA Laser System used oblique proton radiography to measure magnetic fields in cylindrical implosions with and without an applied axial magnetic field. Although the goal of both experiments was to measure the magnitude of the compressed axial magnetic field in the core of the implosion, this field was obfuscated by two features in the coronal plasma produced by the compression beams: an azimuthal self-generated magnetic field and small length scale, high-amplitude structures attributed to collisionless effects. In order to understand these features, synthetic radiographs are generated using fields produced by 3D HYDRA simulations. These synthetic radiographs reproduce the features of the experimental radiographs with the exception of the small-scale structures. A direct inversion algorithm is successfully applied to a synthetic radiograph but is only partially able to invert the experimental radiographs in part because some protons are blocked by the field coils. The origins of the radiograph features and their dependence on various experimental parameters are explored. Furthermore, the results of this analysis should inform future measurements of compressed axial magnetic fields in cylindrical implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Computed Tomography as a Metrology Technique for the Analysis of Additively Manufactured Material

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non-destructively characterize features in a variety materials like polymer, metals, composites, and explosives. It also has the capability of imaging additively manufacture, machine and assembled parts. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of the material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations due to different stimuli and assess the accuracy of material production. This study focuses on parts manufactured via metal additive manufacturing (AM). Although AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties and performance. The analysis of 3D printed objects has an asset in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e., foams) due to stochastic structures. For this study, the print accuracy of four additively manufactured cylinders will be assessed via X-ray CTto approximate the surface roughness and visualize any major morphological changes to assess the dimensional accuracy of complex additively manufactured parts. It was concluded that using X-ray CT to measure surface roughness was affective because reasonable surface roughness values were measured. Additionally, itwas determined that small-scale features can be produced via additive manufacturing with strong dimensional accuracy so long as the features are highly complex with sharp grooves.

36 MATERIALS SCIENCE↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of super-Gaussian electron distributions on plasma K-shell emission

Electron distributions in laser-produced plasmas will be driven toward a super-Gaussian distribution due to inverse bremsstrahlung absorption [Langdon, Phys. Rev. Lett. 44, 575 (1980)]. Both theoretical and experimental evidence suggest that fundamental plasma properties are altered by the super-Gaussian distribution. Here, this paper examines how the super-Gaussian distribution affects the ionization balance and K-shell emission of atomic plasmas, utilizing approximate formulas and detailed collisional-radiative simulations. While the impact on plasma ionization is small, K-shell spectra can be significantly modified. Based on these findings, we demonstrate that K-shell spectroscopy can be used to infer super-Gaussian or other similar nonequilibrium electron distributions.

Atomic spectra↗

3D printed features on nuclear fuel cladding for optimized heat transfer

A nuclear fuel cladding with improved thermomechanical properties is provided. The nuclear fuel cladding includes a double-walled construction having inner and outer hexagonal sidewalls. The inner sidewall and the outer sidewall are spaced apart from each other to form a cooling channel therebetween, and the inner sidewall surrounds a nuclear fuel and is spaced apart from the nuclear fuel by a small gap. Helical fins extend into the cooling channel to interconnect the inner sidewall and the outer sidewall. Resilient fingers extend toward the nuclear fuel through the small gap to comply with variations in the size of the nuclear fuel due to fabrication tolerances as well as thermal expansion and swelling of the nuclear fuel, for example UO 2 , when undergoing fission. The nuclear fuel cladding is formed according to an additive manufacturing process, for example laser powder bed fusion printing.

Petrie, Christian M.↗

An advanced workflow for single-particle imaging with the limited data at an X-ray free-electron laser

An improved analysis for single-particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from half of the detector and a small fraction of single hits. The general SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus-structure determination step. The presented processing pipeline allowed us to determine the 3D structure of bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ligand‐Mediated Quantum Yield Enhancement in 1‐D Silver Organothiolate Metal–Organic Chalcogenolates

X-ray free electron laser (XFEL) microcrystallography and synchrotron single-crystal crystallography are used to evaluate the role of organic substituent position on the optoelectronic properties of metal–organic chalcogenolates (MOChas). MOChas are crystalline 1D and 2D semiconducting hybrid materials that have varying optoelectronic properties depending on composition, topology, and structure. While MOChas have attracted much interest, small crystal sizes impede routine crystal structure determination. A series of constitutional isomers where the aryl thiol is functionalized by either methoxy or methyl ester are solved by small molecule serial femtosecond X-ray crystallography (smSFX) and single crystal rotational crystallography. While all the methoxy examples have a low quantum yield (0-1%), the methyl ester in the ortho position yields a high quantum yield of 22%. Here, the proximity of the oxygen atoms to the silver inorganic core correlates to a considerable enhancement of quantum yield. Four crystal structures are solved at a resolution range of 0.8–1.0 Å revealing a collapse of the 2D topology for functional groups in the 2- and 3- positions, resulting in needle-like crystals. Further analysis using density functional theory (DFT) and many-body perturbation theory (MBPT) enables the exploration of complex excitonic phenomena within easily prepared material systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗