Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

U.S. Department of Energy Office of Legacy Management Calibration Facilities - 12103

This paper describes radiometric calibration facilities located in Grand Junction, Colorado, and at three secondary calibration sites. These facilities are available to the public for the calibration of radiometric field instrumentation for in-situ measurements of radium (uranium), thorium, and potassium. Both borehole and hand-held instruments may be calibrated at the facilities. Aircraft or vehicle mounted systems for large area surveys may be calibrated at the Grand Junction Regional Airport facility. These calibration models are recognized internationally as stable, well-characterized radiation sources for calibration. Calibration models built in other countries are referenced to the DOE models, which are also widely used as a standard for calibration within the U.S. Calibration models are used to calibrate radiation detectors used in uranium exploration, remediation, and homeland security. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FROM RECENT SCIENCE AND TECHNOLOGY INVESTIGATIONS TARGETING CHROMIUM IN THE 100D AREA HANFORD SITE WASHINGTON USA

Sodium dichromate was used in Hanford's 100D Area during the reactor operations period of 1950 to 1964 to retard corrosion in the reactor cooling systems. Some of the sodium dichromate was released to the environment by spills and/or leaks from pipelines used to deliver the chemical to water treatment plants in the area. As a result, hexavalent chromium [Cr(VI)] has migrated through the vadose zone to the groundwater and contaminated nearly 1 km{sup 2} of groundwater to above the drinking water standard of 48 {micro}g/L. Three technology tests have recently been completed in this area to characterize the source area of the plumes and evaluate alternative methods to remove Cr(VI) from groundwater. These are (1) refine the source area of the southern plume; (2) test electrocoagulation as an alternative groundwater treatment technology; and (3) test the ability to repair a permeable reactive barrier by injecting micron or nanometer-size zero-valent iron (ZVI). The projects were funded by the US Department of Energy as part of a program to interject new technologies and accelerate active cleanup. Groundwater monitoring over the past 10 years has shown that Cr(VI) concentrations in the southern plume have not significantly diminished, strongly indicating a continuing source. Eleven groundwater wells were installed in 2007 and 2008 near a suspected source area and monitored for Cr(VI) and groundwater levels. Interpretation of these data has led to refinement of the source area location to an area of less than 1 hectare (ha, 2.5 acres). Vadose zone soil samples collected during drilling did not discover significant concentrations of Cr(VI), indicating the source is localized, with a narrow wetted path from the surface to the water table. Electrocoagulation was evaluated through a pilot-scale treatability test. Over 8 million liters of groundwater were treated to Cr(VI) concentrations of {le}20 {micro}g/L. The test determined that this technology has the potential to treat Cr(VI) to these low levels, but system reliability and operational complexity rendered electrocoagulation less cost effective than the baseline technology of ion exchange. Laboratory and field tests were conducted to evaluate the practicality of injecting ZVI into the aquifer to increase the lifespan and effectiveness of an existing permeable reactive barrier. From a database of 30 ZVI materials, 6 were chosen and tested in the laboratory to determine their geochemical and physical performance under simulated 100D aquifer conditions. The best-performing ZVI was injected into the aquifer and met the primary goals of communicating the iron at least 7 meters from the injection point and reducing the aquifer to transform mobile Cr(VI) to trivalent chromium Cr(III), which is effectively immobile in the aquifer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IMPROVED COMPUTATIONAL CHARACTERIZATION OF THE THERMAL NEUTRON SOURCE FOR NEUTRON CAPTURE THERAPY RESEARCH AT THE UNIVERSITY OF MISSOURI

Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The computational models used for the final beam design and performance evaluation are based on coupled discrete-ordinates and Monte Carlo techniques that permit detailed modeling of the neutron transmission properties of the filtering crystals with very few approximations. This is essential for detailed dosimetric studies required for the anticipated research program.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards the understanding of PETN initiation by a fast, high power arc source

We present a thorough characterization of a capacitor driven arc source that can deliver up to 200 mJ of energy to the arc and high explosive in a well-controlled, repeatable manner on the hundreds of nanoseconds time-scale. Our ultimate purpose is to create a platform to study high explosive kinetics under extreme conditions of high-temperature. In the current paper, we characterize the behavior of our arc source by electrical discharge over a thin PETN film. Temperature and density are determined by time-resolved atomic emission spectroscopy on the nano- to microsecond time scale along with fast photographic imaging to capture time-resolved images of the expanding plasma. We also discuss preliminary simulations of arc plasma using a 1-D hydrodynamic model. Comparisons of these simulations with experimental data are presented. Ultimately our goal is to create a platform that will generate conditions of high temperature in order to study high explosive kinetics. We believe that our arc source platform can be further combined with a time-resolved vibrational spectroscopy (e.g. IR or Raman) to study chemical kinetics under extreme conditions. High temperature conditions may access novel reactive pathways that are different from either shock or slower thermal processes that are substantially lower in temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral induced polarization (SIP) measurements across a PFAS-contaminated source zone

There is a pressing need for the development of field-scale, in situ screening technologies for assessing variations in aqueous film forming foam (AFFF) concentrations in soils at former fire training and storage sites. Field-scale Spectral Induced Polarization (SIP) geophysical measurements were acquired on a transect crossing an AFFF source zone. Soil samples were acquired from ten locations and used to determine variations in poly- and per-fluoroalkyl substances (PFAS) concentrations in soils and soil texture. These samples were also used to create triplicate soil columns for laboratory-grade SIP measurements. Field and laboratory observations provide evidence that SIP measurements are sensitive to the concentration of AFFF constituents associated with the pore surface in soils. The phase of the SIP measurements on the laboratory samples was linearly correlated with total soil-sorbed PFAS concentration. The phase from the field SIP measurements was highest over the location of maximum PFAS concentration measured on the laboratory samples, although a significant correlation between field-measured phase and laboratory-measured total PFAS concentration was not established. The sensitivity of the SIP response to the removal of soil PFAS using a methanol wash procedure (total PFAS concentration drop of 366 ppb) adds evidence for the case for SIP characterization of AFFF source zones. The results of these studies suggest that SIP might be developed into a field-scale technology for rapid, indirect assessment of AFFF source zones. Such a technology could improve the effectiveness of AFFF source zone characterization at reduced costs.

58 GEOSCIENCES↗

Radiological Characterization Technical Report for Curium-244 Sealed Source Transuranic Debris Waste for the Off-Site Source Recovery Project at Los Alamos National Laboratory

This document describes the development and approach for the radiological characterization of Cm-244 sealed sources for shipment to the Waste Isolation Pilot Plant. The document uses the extensive documentation and information on the nuclear material content of each source (mass or activity of material used) and information and data on the radionuclide distributions within the nuclear material. This information allows complete characterization without the need for additional measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-284: Revisiting Reference Dosimetry for the Model S700 Axxent 50 KV{sub p} Electronic Brachytherapy Source

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft was characterized in 2006 by Rivard et al. The source design was modified in 2006 to include a plastic centering insert at the source tip to more accurately position the anode. The objectives of the current study were to establish an accurate Monte Carlo source model for simulation purposes, to dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and to determine dose differences between the source with and without the centering insert. Methods: Design information from dissected sources and vendor-supplied CAD drawings were used to devise the source model for radiation transport simulations of dose distributions in a water phantom. Collision kerma was estimated as a function of radial distance, r, and polar angle, θ, for determination of reference TG-43 dosimetry parameters. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.03% at r=1 cm and 0.08% at r=10 cm. Results: The dose rate distribution the transverse plane did not change beyond 2% between the 2006 model and the current study. While differences exceeding 15% were observed near the source distal tip, these diminished to within 2% for r>1.5 cm. Differences exceeding a factor of two were observed near θ=150° and in contact with the source, but diminished to within 20% at r=10 cm. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% over a third of the available solid angle external from the source. For clinical applications using balloons or applicators with tissue located within 5 cm from the source, dose differences exceeding 2% were observed only for θ>110°. This study carefully examined the current source geometry and presents a modern reference TG-43 dosimetry dataset for the model S700 source.

60 APPLIED LIFE SCIENCES↗

Approach for the isotopic characterization of irradiated start-up sources for disposal at WIPP - 15674

The National Nuclear Security Administration, Global Threat Reduction Initiative (GTRI)/ Off-site Source Recovery Program (OSRP) requires an approved final disposition pathway for sealed irradiated startup sources with uncertain irradiation histories. To create this path a reliable method is required to determine yields of transmutation, fission and activation products contained within the source at the time of disposal. Because of the uncertain histories of these sources, a number of likely histories are modeled with the code ORIGEN in order to establish the bounds of the radioisotope yields. The ORIGEN simulations are confirmed with gamma spectroscopy, specifically examining the activities of several fission and transmutation isotopes. These calculations, coupled with other previously established characterization techniques for transuranic neutron sources, will be used to establish a waste profile that is in compliance with Waste Isolation Pilot Plant (WIPP) waste acceptance criteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Instantiation of crystal plasticity simulations for micromechanical modelling with direct input from microstructural data collected at light sources

Novel non-destructive characterization techniques performed at light sources provide previously inaccessible 3-D mesoscopic information on the deformation of polycrystalline materials. One major difficulty for interpretation of these experiments through micromechanical modelling is the likelihood that processing and/or mounting the sample introduce residual stresses in the specimen. These stresses need to be incorporated into crystal plasticity formulations, for these models to operate directly from microstructural images and be predictive. To achieve this, the initial micromechanical state of each voxel needs to be specified. Here in this letter we present a method for incorporating grain-averaged residual stresses for instantiation of crystal plasticity simulations.

36 MATERIALS SCIENCE↗

Plasma Emission Characteristics in Laser Induced Breakdown Spectroscopy of Silicon with Mid-Infrared, Multi-Millijoule, Nanosecond Laser Pulses from a Ho:YLF Excitation Source

Here, we characterized the plasma emission produced by the interaction of multimilijoule, 40 ns duration, mid-infrared laser pulses with a silicon surface. The laser pulses were produced by a Q-switched Ho:YLF master oscillator power amplifier system. Using spectral measurements and a framing camera we observed a spatial separation of the plasma plume, increased emission signal with low white light generation, and a drop in the time- and space-averaged apparent plasma density with increasing pump energy. Our findings can be explained by continuous heating of the plasma by the pump pulse due to the more efficient inverse bremsstrahlung absorption at longer wavelengths.

47 OTHER INSTRUMENTATION↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evidence for Unresolved γ -Ray Point Sources in the Inner Galaxy

We propose a new method to characterize unresolved point sources (PSs) generalizing traditional template fits to account for non-Poissonian photon statistics. We apply this method to Fermi Large Area Telescope γ-ray data to characterize PS populations at high latitudes and in the Inner Galaxy. We discover that PSs (resolved and unresolved) account for ~50% of the total extragalactic γ-ray background in the energy range ~1.9 to 11.9 GeV.Within 10° of the Galactic Center with |b| ≥ 2°, we find that ~5%–10% of the flux can be accounted for by a population of unresolved PSs distributed consistently with the observed ~GeV γ-ray excess in this region. The excess is fully absorbed by such a population, in preference to dark-matter annihilation. The inferred source population is dominated by near-threshold sources, which may be detectable in future searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Source Physics Experiment modeling: YEARLY REPORT FOR THE PERIOD Jan-Dec 2012

The Office of Nuclear Detonation Detection identifies characterization of the explosion source as a fundamental research area. Our ability to characterize explosion sources from earthquakes relies on empirical laws that are not covering all the possible cases of location, site structure and yields of possible explosions. Our empirical knowledge needs to be completed by a physical understanding of seismic wave generation. NA22 has funded the LANL SPE seismic project to develop a new source model under the Ground-Based Nuclear Explosion Monitoring Research and Development (GNEM-R&D) Program. NA22 also funds computational support of the seismic source model development. Hydrodynamic computations using realistic material response models combined with a comprehensive series of field experiments provided by the SPE program are needed for test and validation of the new seismic source models. The following three essential elements, (1) model development, (2) numerical simulations of non-linear material response, and (2) field experimentation, will be brought to bear on a predictive capability for broadband P and S wavefields with a sound physical basis for seismic monitoring applications. This research will advance our ability to address yield estimation for UNE conducted in proliferant nations and provide a better understanding of the coupling of explosion sources to the seismic wavefield.

58 GEOSCIENCES↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Monte Carlo characterization of a new Yb-169 high dose rate source for brachytherapy application

Purpose: The objective was to characterize a new Yb-169 high dose rate source for brachytherapy application. Methods: Monte Carlo simulations were performed using the MCNP5 F6 energy deposition tallies placed around the Yb-169 source at different radial distances in both air-vacuum and water environments. The calculations were based on a spherical water phantom with a radius of 50 cm. The output from the simulations was converted into radial dose rate distribution in polar coordinates surrounding the brachytherapy source. Results: The results from Monte Carlo simulations were used to calculate the AAPM Task Group 43 dosimetric parameters: Anisotropy function, radial dose function, air kerma strength, and dose rate constant. The results indicate a dose rate constant of 1.12{+-}0.04 cGy h{sup -1} U{sup -1}, anisotropy function ranging from 0.44 to 1.00 for radial distances of 0.5-10 cm and polar angles of 0 deg. - 180 deg. Conclusions: The data from the Yb-169 HDR source, Model M42, presented in this study show that this source compares favorably with another source of Yb-169, Model 4140, already approved for brachytherapy treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatability Test Report: Characterization of Vadose Zone Carbon Tetrachloride Source Strength Using Tomographic Methods at the 216-Z-9 Site

A treatability test was conducted in 2011 at the 216-Z-9 Trench to evaluate methods for collecting characterization information that supports refined assessment of SVE performance goals based on impact to groundwater. The characterization information can also provide input to operational strategies for continued SVE operation and decisions regarding closure of the SVE system or transition to other remedies, if necessary.

Carbon Tetrachloride↗

Characterizing Risk for Cumulative Risk Assessments: Characterizing Risk for Cumulative Risk Assessments

In assessing environmental health risks, the risk characterization step synthesizes information gathered in evaluating exposures to stressors together with dose-response relationships, characteristics of the exposed population, and external environmental conditions. This article summarizes key steps of a cumulative risk assessment (CRA) followed by a discussion of considerations for characterizing cumulative risks. Cumulative risk characterizations differ considerably from single chemical- or single source-based risk characterization. CRAs typically focus on a specific population instead of a pollutant or pollutant source and should include an evaluation of all relevant sources contributing to the exposures in the population and other factors that influence dose-response relationships. Second, CRAs may include influential environmental and population-specific conditions, involving multiple chemical and nonchemical stressors. Third, a CRA could examine multiple health effects, reflecting joint toxicity and the potential for toxicological interactions. Fourth, the complexities often necessitate simplifying methods, including judgment-based and semi-quantitative indices that collapse disparate data into numerical scores. Fifth, because of the higher dimensionality and potentially large number of interactions, information needed to quantify risk is typically incomplete, necessitating an uncertainty analysis. Three approaches that could be used for characterizing risks in a CRA are presented: the multiroute hazard index, stressor grouping by exposure and toxicity, and indices for screening multiple factors and conditions. Other key roles of the risk characterization in CRAs are also described, mainly the translational aspect of including a characterization summary for lay readers (in addition to the technical analysis), and placing the results in the context of the likely risk-based decisions.

60 APPLIED LIFE SCIENCES↗