Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A nonventing cooling system for space environment extravehicular activity, using radiation and regenerable thermal storage

This paper outlines the selection, design, and testing of a prototype nonventing regenerable astronaut cooling system for extravehicular activity space suit applications, for mission durations of four hours or greater. The selected system consists of the following key elements: a radiator assembly which serves as the exterior shell of the portable life support subsystem backpack; a layer of phase change thermal storage material, n-hexadecane paraffin, which acts as a regenerable thermal capacitor; a thermoelectric heat pump; and an automatic temperature control system. The capability for regeneration of thermal storage capacity with and without the aid of electric power is provided.

Bayes, Stephen A.↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Poisson_CCD: A dedicated simulator for modeling CCDs

A dedicated simulator, Poisson_CCD, has been constructed which models astronomical CCDs by solving Poisson’s equation numerically and simulating charge transport within the CCD. The potentials and free carrier densities within the CCD are self-consistently solved for, giving realistic results for the charge distribution within the CCD storage wells. The simulator has been used to model the CCDs that are being used to construct the LSST digital camera. The simulator output has been validated by comparing its predictions with several different types of CCD measurements, including astrometric shifts, brighter-fatter induced pixel–pixel covariances, saturation effects, and diffusion spreading. The code is open source and freely available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine

03 NATURAL GAS↗

He Leak Testing of 3013 Inner Container Lids

The 3013-container package is used for the long-term storage of plutonium bearing materials at Department of Energy (DOE) sites. The package consists of three nested stainless-steel containers: outer, inner and convenience, which are made of stainless steel. The requirements of the DOE 3013 Standarda, also entail the development of a surveillance program, tasked to ensure structural integrity of the outer container for at least 50 years. The Materials Identification and Surveillance Working Group (MIS-WG) is specified to be responsible for selecting the containers for the surveillance as well as analyzing results. The MIS-WG determined that corrosion is a potential mechanism for container degradation with the most credible type of failure to be stress corrosion cracking (SCC) through wall breach of the inner container closure weld region (ICCWR). A breach of the inner container has the potential of allowing corrosive gases to be released into the safety class outer container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low cost computer subsystem for the Solar Electric Propulsion Stage (SEPS)

The Solar Electric Propulsion Stage (SEPS) subsystem which consists of the computer, custom input/output (I/O) unit, and tape recorder for mass storage of telemetry data was studied. Computer software and interface requirements were developed along with computer and I/O unit design parameters. Redundancy implementation was emphasized. Reliability analysis was performed for the complete command computer sybsystem. A SEPS fault tolerant memory breadboard was constructed and its operation demonstrated.

Source record↗

A thruster sub-system module /TSSM/ for solar electric propulsion

The thruster subsystem module (TSSM) considered for solar electric propulsion (SEP) missions is to consist of a 30-cm ion thruster, a thruster gimbal system, a propellant storage and feed system, a power processing unit, a modular thermal control system, and a modular support structure. TSSM design requirements are considered along with a TSSM general design approach. It is pointed out that a TSSM for SEP missions can be designed and built based on existing technology.

Sharp, G. R.↗

System design package for SIMS prototype system 4, solar heating and domestic hot water

The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.

Source record↗

Solar hot water system installed at Quality Inn, Key West, Florida

The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.

Source record↗

Solar energy system performance evaluation report for IBM System 4 at Clinton, Mississippi

The IBM System 4 Solar Energy System is described and evaluated. The system was designed to provide 35 percent of the space heating and 63 percent of the domestic hot water preheating for a single family residence located within the United States. The system consists of 259 square feet of flat plate air collectors, a rock thermal storage containing 5 1/2 ton of rock, heat exchangers, blowers, a 52 gallon preheat tank, controls, and associated plumbing. In general, the performance of the system did not meet design expectations, since the overall design solar fraction was 48 percent and the measured value was 32 percent. Although the measured space heating solar fraction at 32 percent did agree favorably with the design space heating solar fraction at 35 percent, the hot water measured solar fraction at 33 percent did not agree favorably with the design hot water solar fraction of 63 percent. In particular collector array air leakage, dust covered collectors, abnormal hot water demand, and the preheat tank by pass valve problem are main reasons for the lower performance.

Source record↗

The preparation and archiving of machine-readable astronomical data

The preparation of machine-readable astronomical catalogs for archiving and distribution from the ADC is described. Examples of specific format and data structure changes to improve compatibility with other computers, to homogenize the presentation of astronomical data among catalogs, and to increase storage efficiency are given. Various checks which are often made to insure internal consistency and for comparison with published versions are identified and the importance of permanently archiving astronomical data in the best possible condition is emphasized.

Warren, W. H., Jr.↗

Micro-optic lens for data storage

A new type of microlens for data storage applications that has improved off-axis performance is described. The lens consists of a micro Fresnel pattern on a curved substrate. The radius of the substrate is equal to the focal length of the lens. If the pattern and substrate are thin, the combination satisfies the Abbe sine condition. Therefore, the lens is free of coma. We analyze a 0.5 numerical aperture, 0.50 mm focal length lens in detail. A 0.16 numerical aperture lens was fabricated holographically, and results are presented.

Milster, T. D.↗

A lunar orbiting Node in support of missions to Mars

A conceptual design study yielded an approximate size for the platform needed to support typical oxygen-transfer rates which were based upon NASA studies of Mars missions. The Node consists of a gravity gradient stabilized lunar orbiting tank-farm with a storage capacity of 100,000 kg of lunar oxygen, 3300 kg of lunar cargo, and 9300 kg of earth-supplied hydrogen. An emergency-habitat configuration accommodates 14 persons on-board for 110 days. The Node supports an annual lunar oxygen production of 10 exp 6 kg with 220,000 kg of oxygen delivered to earth orbit for an expenditure of 109,000 kg of earth-supplied hydrogen.

Butterfield, A.↗

Simulation of a Flywheel Electrical System for Aerospace Applications

A Flywheel Energy Storage Demonstration Project was initiated at the NASA Glenn Research Center as a possible replacement for the battery energy storage system on the International Space Station (ISS). While the hardware fabrication work was being performed at a university and contractor's facility, the related simulation activity was begun at Glenn. At the top level, Glenn researchers simulated the operation of the ISS primary electrical system (as described in another paper) with the Flywheel Energy Storage Unit (FESU) replacing one Battery Charge and Discharge Unit (BCDU). The FESU consists of a Permanent Magnet Synchronous Motor/Generator (PMSM), which is connected to the flywheel; the power electronics that connects the PMSM to the ISS direct-current bus; and the associated controller. The PMSM model is still under development, but this paper describes the rest of the FESU model-the simulation of the converter and the associated control system that regulates energy transfer to and from the flywheel.

Truong, Long V.↗

DSN Beowulf Cluster-Based VLBI Correlator

The NASA Deep Space Network (DSN) requires a broadband VLBI (very long baseline interferometry) correlator to process data routinely taken as part of the VLBI source Catalogue Maintenance and Enhancement task (CAT M&E) and the Time and Earth Motion Precision Observations task (TEMPO). The data provided by these measurements are a crucial ingredient in the formation of precision deep-space navigation models. In addition, a VLBI correlator is needed to provide support for other VLBI related activities for both internal and external customers. The JPL VLBI Correlator (JVC) was designed, developed, and delivered to the DSN as a successor to the legacy Block II Correlator. The JVC is a full-capability VLBI correlator that uses software processes running on multiple computers to cross-correlate two-antenna broadband noise data. Components of this new system (see Figure 1) consist of Linux PCs integrated into a Beowulf Cluster, an existing Mark5 data storage system, a RAID array, an existing software correlator package (SoftC) originally developed for Delta DOR Navigation processing, and various custom- developed software processes and scripts. Parallel processing on the JVC is achieved by assigning slave nodes of the Beowulf cluster to process separate scans in parallel until all scans have been processed. Due to the single stream sequential playback of the Mark5 data, some ramp-up time is required before all nodes can have access to required scan data. Core functions of each processing step are accomplished using optimized C programs. The coordination and execution of these programs across the cluster is accomplished using Pearl scripts, PostgreSQL commands, and a handful of miscellaneous system utilities. Mark5 data modules are loaded on Mark5 Data systems playback units, one per station. Data processing is started when the operator scans the Mark5 systems and runs a script that reads various configuration files and then creates an experiment-dependent status database used to delegate parallel tasks between nodes and storage areas (see Figure 2). This script forks into three processes: extract, translate, and correlate. Each of these processes iterates on available scan data and updates the status database as the work for each scan is completed. The extract process coordinates and monitors the transfer of data from each of the Mark5s to the Beowulf RAID storage systems. The translate process monitors and executes the data conversion processes on available scan files, and writes the translated files to the slave nodes. The correlate process monitors the execution of SoftC correlation processes on the slave nodes for scans that have completed translation. A comparison of the JVC and the legacy Block II correlator outputs reveals they are well within a formal error, and that the data are comparable with respect to their use in flight navigation. The processing speed of the JVC is improved over the Block II correlator by a factor of 4, largely due to the elimination of the reel-to-reel tape drives used in the Block II correlator.

Rogstad, Stephen P.↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data (Final Report)

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components: (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine.

20 FOSSIL-FUELED POWER PLANTS↗

VISCEL: A general-purpose computer program for analysis of linear viscoelastic structures (user's manual), volume 1

This program, an extension of the linear equilibrium problem solver ELAS, is an updated and extended version of its earlier form (written in FORTRAN 2 for the IBM 7094 computer). A synchronized material property concept utilizing incremental time steps and the finite element matrix displacement approach has been adopted for the current analysis. A special option enables employment of constant time steps in the logarithmic scale, thereby reducing computational efforts resulting from accumulative material memory effects. A wide variety of structures with elastic or viscoelastic material properties can be analyzed by VISCEL. The program is written in FORTRAN 5 language for the Univac 1108 computer operating under the EXEC 8 system. Dynamic storage allocation is automatically effected by the program, and the user may request up to 195K core memory in a 260K Univac 1108/EXEC 8 machine. The physical program VISCEL, consisting of about 7200 instructions, has four distinct links (segments), and the compiled program occupies a maximum of about 11700 words decimal of core storage.

Gupta, K. K.↗

Shifting groundwater fluxes in bedrock fractures: Evidence from stream water radon and water isotopes

Geologic features (e.g., fractures and alluvial fans) can play an important role in the locations and volumes of groundwater discharge and degree of groundwater-surface water (GW-SW) interactions. However, the role of these features in controlling GW-SW dynamics and streamflow generation processes are not well constrained. GW-SW interactions and streamflow generation processes are further complicated by variability in precipitation inputs from summer and fall monsoon rains, as well as declines in snowpack and changing melt dynamics driven by warming temperatures. Using high spatial and temporal resolution radon and water stable isotope sampling and a 1D groundwater flux model, we evaluated how groundwater contributions and GW-SW interactions varied along a stream reach impacted by fractures (fractured-zone) and below the fractured hillslope (non-fractured zone) in Coal Creek, a Colorado River headwater stream affected by summer monsoons. During early summer, groundwater contributions from the fractured zone dominated, but declined throughout the summer. Groundwater contributions from the non-fractured zone were constant throughout the summer and became proportionally more important later in the summer. We hypothesize that groundwater in the non-fractured zone is dominantly sourced from a high-storage alluvial fan at the base of a tributary that is connected to Coal Creek throughout the summer and provides consistent groundwater influx. Water isotope data revealed that Coal Creek responds quickly to incoming precipitation early in the summer, and summer precipitation becomes more important for streamflow generation later in the summer. We quantified the change in catchment dynamic storage and found it negatively related to stream water isotope values, and positively related to modeled groundwater discharge and the ratio of fractured zone to non-fractured zone groundwater. Importantly, we interpret these relationships as declining hydrologic connectivity throughout the summer leading to late summer streamflow supported predominantly by shallow flow paths, with variable response to drying from geologic features based on their storage. As groundwater becomes more important for sustaining summer flows, quantifying local geologic controls on groundwater inputs and their response to variable moisture conditions may become critical for accurate predictions of streamflow.

54 ENVIRONMENTAL SCIENCES↗