Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

IceCube: CubeSat 883-GHz Radiometry for Future Ice Cloud Remote Sensing

Ice clouds play a key role in the Earth's radiation budget, mostly through their strong regulation of infrared radiation exchange. Accurate observations of global cloud ice and its distribution have been a challenge from space, and require good instrument sensitivities to both cloud mass and microphysical properties. Despite great advances from recent spaceborne radar and passive sensors, uncertainty of current ice water path (IWP) measurements is still not better than a factor of 2. Submillimeter (submm) wave remote sensing offers great potential for improving cloud ice measurements, with simultaneous retrievals of cloud ice and its microphysical properties. The IceCube project is to enable this cloud ice remote sensing capability in future missions, by raising 874-GHz receiver technology TRL from 5 to 7 in a spaceflight demonstration on 3-U CubeSat in a low Earth orbit (LEO) environment. The NASAs Goddard Space Flight Center (GSFC) is partnering with Virginia Diodes Inc (VDI) on the 874-GHz receiver through its Vector Network Analyzer (VNA) extender module product line, to develop an instrument with precision of 0.2 K over 1-second integration and accuracy of 2.0 K or better. IceCube is scheduled to launch to and subsequent release from the International Space Station (ISS) in mid-2016 for nominal operation of 28 plus days. We will present the updated design of the payload and spacecraft systems, as well as the operation concept. We will also show the simulated 874-GHz radiances from the ISS orbits and cloud scattering signals as expected for the IceCube cloud radiometer.

cloud ice remote sensing↗

Design and Performance of A High Resolution Micro-Spec: An Integrated Sub-Millimeter Spectrometer

Micro-Spec is a compact sub-millimeter (approximately 100 GHz--1:1 THz) spectrometer which uses low loss superconducting microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a diffraction grating spectrometer onto a single chip. We have already successfully evaluated the performance of a prototype Micro-Spec, with spectral resolving power, R=64. Here we present our progress towards developing a higher resolution Micro-Spec, which would enable the first science returns in a balloon flight version of this instrument. We describe modifications to the design in scaling from a R=64 to a R=256 instrument, as well as the ultimate performance limits and design concerns when scaling this instrument to higher resolutions.

spectrometer↗

A 220-GHz InP HEMT Direct Detection Polarimeter

In this article, a 220-GHz direct detection polarimetric receiver is reported. This polarimetric receiver is intended for sensing of the microphysical properties of cloud ice in the earth's upper atmosphere. In the article, we report the measured RF performance, including RF gain of approximately 35 dB per channel and integrated noise figure of the receiver. The noise figure is measured to be 5.1 dB for the horizontally polarized channel and 5.4 dB for the vertically polarized channel. The receiver measures only 1.8 cm × 3.0 cm × 6.4 cm and has a total regulated dc power consumption of 520 mW. This article represents the first 220-GHz polarimetric direct detection receiver and is enabled by an advanced 25-nm indium phosphide (InP) HEMT monolithic microwave integrated circuit (MMIC) technology.

Indium phosphide (InP)↗

IceCube: Spaceflight Demonstration of 883-GHz Cloud Radiometer for Future Science

Cloud ice play important roles in Earth’s climate and weather systems through their interactions with atmospheric radiation, dynamics, energy and precipitation processes. Submillimeter (submm) wave remote sensing at 200-1000 GHz is able to provide the sensitivity not covered by visible (VIS)/infrared (IR) and low-frequency microwave (MW) sensors (10-183 GHz), and measure cloud ice in the middle-to-upper troposphere. The IceCube 883-GHz cloud radiometer is the latest of NASA’s efforts to advance the technology readiness level (TRL) of submm-wave receiver technology for future compact, low-cost implementation of Earth observing systems. Emerging CubeSat opportunities allow a fast-track development and spaceflight demonstration of IceCube on a 3-U CubeSat. Funded by NASA’s In-Space Validation of Earth Science Technologies (InVEST) program and Science Mission Directorate (SMD), IceCube is the first CubeSat developed and flown by Goddard Space Flight Center (GSFC) in 2.5 years, using commercial off-the-shelf (COTS) components and subsystems. It was successfully released from International Space Station (ISS) in May 2017, acquired 15-month science data and produced the first global map of the 883-GHz cloud ice. It achieved all mission objectives and provided a pathway for future cost-effective cloud observations from CubeSat constellation.

Submm-wave remote sensing↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Progress by the Georgia Institute of Technology's Laboratory for Radio-science and Remote Sensing in developing techniques for passive microwave retrieval of water vapor profiles and cloud and precipitation parameters using millimeter and submillimeter wavelength channels is reviewed. Channels of particular interest are in the tropospheric transmission windows at 90, 166, 220, 340, and 410 GHz and centered around the water vapor lines at 183 and 325 GHz. Collectively, these channels have potential application in high-resolution precipitation mapping (e.g., from geosynchronous orbit), remote sensing of cloud and precipitation parameters, including cirrus ice mass, and improved retrieval of water vapor profiles. During the period from January 1, 1994 through June 30, 1994 research activities focussed on calibrating and interpreting data from the Millimeter-Wave Imaging Radiometer (MIR). The MIR was deployed on the NASA ER-2 during the Convective Atmospheric Moisture Experiment (CAMEX, September-October 1993) to obtain the first submillimeter-wave tropospheric imagery of convective precipitations. A 325-GHz radiometer consisted of a submillimeter-wave DSB receiver with three IF channels at +/- 1, 3, and 8.5 GHz, and approximately 14 dB DSB noise figure was successfully operated during these experiments. Activities supported under this grant include a study of the impact of local oscillator reflections from the MIR calibration loads, the development of optimal gain and offset filters for radiometric calibration, and the modeling and interpretation of the MIR 325-GHz data over both clear and cloudy atmospheres. In addition, polarimetric radiometer measurements and modeling for ocean surface and atmospheric cloud-ice studies_were supported.

Gasiewski, Albin J.↗

Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging

Most optical systems require antennas with directive patterns. This means that the physical area of the antenna will be large in terms of the wavelength. When non-cooled systems are used, the losses of microstrip or coplanar waveguide lines impede the use of standard patch or slot antennas for a large number of elements in a phased array format. Traditionally, this problem has been solved by using silicon lenses. However, if an array of such highly directive antennas is to be used for imaging applications, the fabrication of many closely spaced lenses becomes a problem. Moreover, planar antennas are usually fed by microstrip or coplanar waveguides while the mixer or the detector elements (usually Schottky diodes) are coupled in a waveguide environment. The coupling between the antenna and the detector/ mixer can be a fabrication challenge in an imaging array at submillimeter wavelengths. Antennas excited by a waveguide (TE10) mode makes use of dielectric superlayers to increase the directivity. These antennas create a kind of Fabry- Perot cavity between the ground plane and the first layer of dielectric. In reality, the antenna operates as a leaky wave mode where a leaky wave pole propagates along the cavity while it radiates. Thanks to this pole, the directivity of a small antenna is considerably enhanced. The antenna consists of a waveguide feed, which can be coupled to a mixer or detector such as a Schottky diode via a standard probe design. The waveguide is loaded with a double-slot iris to perform an impedance match and to suppress undesired modes that can propagate on the cavity. On top of the slot there is an air cavity and on top, a small portion of a hemispherical lens. The fractional bandwidth of such antennas is around 10 percent, which is good enough for heterodyne imaging applications.The new geometry makes use of a silicon lens instead of dielectric quarter wavelength substrates. This design presents several advantages when used in the submillimeter-wave and terahertz bands: a) Antenna fabrication compatible with lithographic techniques. b) Much simpler fabrication of the lens. c) A simple quarter-wavelength matching layer of the lens will be more efficient if a smaller portion of the lens is used. d) The directivity is given by the lens diameter instead of the leaky pole (the bandwidth will not depend anymore on the directivity but just on the initial cavity). The feed is a standard waveguide, which is compatible with proven Schottky diode mixer/detector technologies. The development of such technology will benefit applications where submillimeter- wave heterodyne array designs are required. The main fields are national security, planetary exploration, and biomedicine. For national security, wideband submillimeter radars could be an effective tool for the standoff detection of hidden weapons or bombs concealed by clothing or packaging. In the field of planetary exploration, wideband submillimeter radars can be used as a spectrometer to detect trace concentrations of chemicals in atmospheres that are too cold to rely on thermal imaging techniques. In biomedicine, an imaging heterodyne system could be helpful in detecting skin diseases.

Chattopadhyay, Goutam↗

Collaborative research in tunneling and field emission pumped surface wave local oscillators and amplifiers for infrared and submillimeter wavelengths under director's discretionary fund

Progress is reported in work towards the development of surface wave sources for the infrared and sub-millimeter portion of the spectrum to be based upon electron pumping by tunneling electrons in metal-barrier-metal or metal-barrier-semiconductor devices. Tunneling phenomena and the coupling of radiation to tunnel junctions were studied. The propagation characteristics of surface electro-magnetic modes in metal-insulator-p(++) semiconductor structures as a function of frequency were calculated. A model for the gain process based upon Tucker's formalism was developed and used to estimate what low frequency gain might be expected from such structures. The question of gain was addressed from a more fundamental viewpoint using the method of Lasher and Stern.

Gustafson, T. K.↗

MIRO Calibration Switch Mechanism

The Jet Propulsion Laboratory has designed, analyzed, built, and tested a calibration switch mechanism for the MIRO instrument on the ROSETTA spacecraft. MIRO is the Microwave Instrument for the Rosetta Orbiter; this instrument hopes to investigate the origin of the solar system by studying the origin of comets. Specifically, the instrument will be the first to use submillimeter and millimeter wave heterodyne receivers to remotely examine the P-54 Wirtanen comet. In order to calibrate the instrument, it needs to view a hot and cold target. The purpose of the mechanism is to divert the instrument's field of view from the hot target, to the cold target, and then back into space. This cycle is to be repeated every 30 minutes for the duration of the 1.5 year mission. The paper describes the development of the mechanism, as well as analysis and testing techniques.

Suchman, Jason↗

MIRO calibration switch mechanism

The Jet Propulsion Laboratory has design, analyzed, built, and tested a calibration switch mechanism for the MIRO instrument on the ROSETTA spacecraft. MIRO is the Microwave Instrument for the Rosetta Orbiter; this instrument hopes to investigate the origin of the solar system by studying the origin of comets. Specifically, the instrument will be the first to use submillimeter and millimeter wave heterodyne receivers to remotely examine the P-54 Wirtanen comet. In order to calibrate the instrument, it needs to view a hot and cold target. The purpose of the mechanism is to divert the instrument’s field of view from the hot target, to the cold target, and then back into space. This cycle is to be repeated every 30 minutes for the duration of the 1.5 year mission. The paper hopes to explain the development of the mechanism, as well as analysis and testing techniques.

Kubo, Holly↗

High-Temperature Surface-Acoustic-Wave Transducer

Aircraft-engine rotating equipment usually operates at high temperature and stress. Non-invasive inspection of microcracks in those components poses a challenge for the non-destructive evaluation community. A low-profile ultrasonic guided wave sensor can detect cracks in situ. The key feature of the sensor is that it should withstand high temperatures and excite strong surface wave energy to inspect surface/subsurface cracks. As far as the innovators know at the time of this reporting, there is no existing sensor that is mounted to the rotor disks for crack inspection; the most often used technology includes fluorescent penetrant inspection or eddy-current probes for disassembled part inspection. An efficient, high-temperature, low-profile surface acoustic wave transducer design has been identified and tested for nondestructive evaluation of structures or materials. The development is a Sol-Gel bismuth titanate-based surface-acoustic-wave (SAW) sensor that can generate efficient surface acoustic waves for crack inspection. The produced sensor is very thin (submillimeter), and can generate surface waves up to 540 C. Finite element analysis of the SAW transducer design was performed to predict the sensor behavior, and experimental studies confirmed the results. One major uniqueness of the Sol-Gel bismuth titanate SAW sensor is that it is easy to implement to structures of various shapes. With a spray coating process, the sensor can be applied to surfaces of large curvatures. Second, the sensor is very thin (as a coating) and has very minimal effect on airflow or rotating equipment imbalance. Third, it can withstand temperatures up to 530 C, which is very useful for engine applications where high temperature is an issue.

Zhao, Xiaoliang↗

New Molecular Species In Comet C/1995 (Hale-Bopp) Observed with the Caltech Submillimeter Observatory

We present millimeter-wave observations of HNCO, HC3N, SO, NH2CHO, H(13)CN, and H3O(+) in comet C/1995 O1 (Hale-Bopp) obtained in February-April, 1997 with the Caltech Submillimeter Observatory (CSO). HNCO, first detected at the CSO in comet C/1996 B2 (Hyakutake), is securely confirmed in comet Hale-Bopp via observations of three rotational transitions. The derived abundance with respect to H2O is (4-13) x 10(exp -4). HC3N, SO, and NH2CHO are detected for the first time in a comet. The fractional abundance of HC3N based on observations of three rotational lines is (1.9 +/- 0.2) x 10(exp -4). Four transitions of SO are detected and the derived fractional abundance, (2-8) x 10(exp -3), is higher than the upper limits derived from UV observations of previous comets. Observations of NH2CHO imply a fractional abundance of (1-8) x 10(exp -4). H3O(+) is detected for the first time from the ground. The H(13)CN (3-2) transition is also detected and the derived HCN/H(13)CN abundance ratio is 90 +/- 15, consistent with the terrestrial C-13/C-12 ratio. in addition, a number of other molecular species are detected, including HNC, OCS, HCO(+), CO(+), and CN (the last two are first detections in a comet at radio wavelengths).

Lis, D. C.↗

In Situ Guided Wave Structural Health Monitoring System

Aircraft engine rotating equipment operates at high temperatures and stresses. Noninvasive inspection of microcracks in those components poses a challenge for nondestructive evaluation. A low-cost, low-profile, high-temperature ultrasonic guided wave sensor was developed that detects cracks in situ. The transducer design provides nondestructive evaluation of structures and materials. A key feature of the sensor is that it withstands high temperatures and excites strong surface wave energy to inspect surface and subsurface cracks. The sol-gel bismuth titanate-based surface acoustic wave (SAW) sensor can generate efficient SAWs for crack inspection. The sensor is very thin (submillimeter) and can generate surface waves up to 540 C. Finite element analysis of the SAW transducer design was performed to predict the sensor behavior, and experimental studies confirmed the results. The sensor can be implemented on structures of various shapes. With a spray-coating process, the sensor can be applied to the surface of large curvatures. It has minimal effect on airflow or rotating equipment imbalance, and provides good sensitivity.

Zhao, George↗

A Massive Bipolar Outflow and a Dusty Torus with Large Grains in the Preplanetary Nebula IRAS 22036+5306

We report high angular resolution (approx.1") CO J=3-2 interferometric mapping using the Submillimeter Array (SMA) of IRAS 22036+5306 (I22036), a bipolar preplanetary nebula (PPN) with knotty jets discovered in our HST snapshot survey of young PPNs. In addition, we have obtained supporting lower resolution (approx.10") CO and 13CO J=1-0 observations with the Owens Valley Radio Observatory (OVRO) interferometer, as well as optical long-slit echelle spectra at the Palomar Observatory. The CO J=3-2 observations show the presence of a very fast (approx.220 km/s), highly collimated, massive (0.03 Solar Mass) bipolar outflow with a very large scalar momentum (about 10(exp 39) g cm/s), and the characteristic spatiokinematic structure of bow shocks at the tips of this outflow. The H(alpha) line shows an absorption feature blueshifted from the systemic velocity by approx.100 km/s, which most likely arises in neutral interface material between the fast outflow and the dense walls of the bipolar lobes at low latitudes. The fast outflow in I22036, as in most PPNs, cannot be driven by radiation pressure. We find an unresolved source of submillimeter (and millimeter-wave) continuum emission in I22036, implying a very substantial mass (0.02-0.04 Solar Mass) of large (radius > or approx.1 mm), cold (< or approx.50 K) dust grains associated with I22036's toroidal waist. We also find that the C-13/C-12 ratio in I22036 is very high (0.16), close to the maximum value achieved in equilibrium CNO nucleosynthesis (0.33). The combination of the high circumstellar mass (i.e., in the extended dust shell and the torus) and the high C-13/C-12 ratio in I22036 provides strong support for this object having evolved from a massive (> or approx.4 Solar Mass) progenitor in which hot-bottom-burning has occurred.

stars↗

AT2018cow: A Luminous Millimeter Transient

We present detailed submillimeter- through centimeter-wave observations of the extraordinary extragalactic transient AT2018cow. The apparent characteristics—the high radio luminosity, the rise and long-lived emission plateau at millimeter bands, and the sub-relativistic velocity—have no precedent. A basic interpretation of the data suggests E(k) ≳ 4 X 10^(48) erg coupled to a fast but sub-relativistic (v ≈ 0.13c) shock in a dense (n(e) ≈ 3 X 10^(5) per cu. cm) medium. We find that the X-ray emission is not naturally explained by an extension of the radio-submm synchrotron spectrum, nor by inverse Compton scattering of the dominant blackbody UV/optical/IR photons by energetic electrons within the forward shock. By ∆t ≈ 20 days, the X-ray emission shows spectral softening and erratic inter-day variability. Taken together, we are led to invoke an additional source of X-ray emission: the central engine of the event. Regardless of the nature of this central engine, this source heralds a new class of energetic transients shocking a dense medium, which at early times are most readily observed at millimeter wavelengths

Anna Y. Q. Ho↗