Statistical Calibration and Validation of a Homogeneous Ventilated Wall-Interference Correction Method for the National Transonic Facility

Wind tunnel experiments will continue to be a primary source of validation data for many types of mathematical and computational models in the aerospace industry. The increased emphasis on accuracy of data acquired from these facilities requires understanding of the uncertainty of not only the measurement data but also any correction applied to the data. One of the largest and most critical corrections made to these data is due to wall interference. In an effort to understand the accuracy and suitability of these corrections, a statistical validation process for wall interference correction methods has been developed. This process is based on the use of independent cases which, after correction, are expected to produce the same result. Comparison of these independent cases with respect to the uncertainty in the correction process establishes a domain of applicability based on the capability of the method to provide reasonable corrections with respect to customer accuracy requirements. The statistical validation method was applied to the version of the Transonic Wall Interference Correction System (TWICS) recently implemented in the National Transonic Facility at NASA Langley Research Center. The TWICS code generates corrections for solid and slotted wall interference in the model pitch plane based on boundary pressure measurements. Before validation could be performed on this method, it was necessary to calibrate the ventilated wall boundary condition parameters. Discrimination comparisons are used to determine the most representative of three linear boundary condition models which have historically been used to represent longitudinally slotted test section walls. Of the three linear boundary condition models implemented for ventilated walls, the general slotted wall model was the most representative of the data. The TWICS code using the calibrated general slotted wall model was found to be valid to within the process uncertainty for test section Mach numbers less than or equal to 0.60. The scatter among the mean corrected results of the bodies of revolution validation cases was within one count of drag on a typical transport aircraft configuration for Mach numbers at or below 0.80 and two counts of drag for Mach numbers at or below 0.90.

Walker, Eric Lee↗

Statistical Calibration and Validation of a Homogeneous Ventilated Wall-Interference Correction Method for the National Transonic Facility

Wind tunnel experiments will continue to be a primary source of validation data for many types of mathematical and computational models in the aerospace industry. The increased emphasis on accuracy of data acquired from these facilities requires understanding of the uncertainty of not only the measurement data but also any correction applied to the data. One of the largest and most critical corrections made to these data is due to wall interference. In an effort to understand the accuracy and suitability of these corrections, a statistical validation process for wall interference correction methods has been developed. This process is based on the use of independent cases which, after correction, are expected to produce the same result. Comparison of these independent cases with respect to the uncertainty in the correction process establishes a domain of applicability based on the capability of the method to provide reasonable corrections with respect to customer accuracy requirements. The statistical validation method was applied to the version of the Transonic Wall Interference Correction System (TWICS) recently implemented in the National Transonic Facility at NASA Langley Research Center. The TWICS code generates corrections for solid and slotted wall interference in the model pitch plane based on boundary pressure measurements. Before validation could be performed on this method, it was necessary to calibrate the ventilated wall boundary condition parameters. Discrimination comparisons are used to determine the most representative of three linear boundary condition models which have historically been used to represent longitudinally slotted test section walls. Of the three linear boundary condition models implemented for ventilated walls, the general slotted wall model was the most representative of the data. The TWICS code using the calibrated general slotted wall model was found to be valid to within the process uncertainty for test section Mach numbers less than or equal to 0.60. The scatter among the mean corrected results of the bodies of revolution validation cases was within one count of drag on a typical transport aircraft configuration for Mach numbers at or below 0.80 and two counts of drag for Mach numbers at or below 0.90.

Walker, Eric L.↗

Induced protein expression in Leptospira spp. and its application to CRISPR/Cas9 mutant generation

Abstract Expanding the genetic toolkit for Leptospira spp. is a crucial step toward advancing our understanding of the biology and virulence of these atypical bacteria. Pathogenic Leptospiraare responsible for over 1 million human leptospirosis cases annually and significantly impact domestic animals. Bovine leptospirosis causes substantial financial losses due to abortion, stillbirths, and suboptimal reproductive performance. The advent of the CRISPR/Cas9 system has marked a turning point in genetic manipulation, with applications across multiple Leptospira species. However, incorporating controlled protein expression into existing genetic tools could further expand their utility. We developed and demonstrated the functionality of IPTG-inducible heterologous protein expression in Leptospira spp. This system was applied for regulated expression of dead Cas9 (dCas9) to generate knockdown mutants, and Cas9 to produce knockout mutants by inducing double-strand breaks (DSB) into desired targets. IPTG-induced dCas9 expression enabled validation of essential genes and non-coding RNAs. Additionally, IPTG-controlled Cas9 expression combined with a constitutive non-homologous end-joining (NHEJ) system allowed for successful recovery of knockout mutants, even in the absence of IPTG. These newly controlled protein expression systems will advance studies on the basic biology and virulence ofLeptospira, as well as facilitate knockout mutant generation for improved veterinary vaccines.

Science & Technology - Other Topics↗

TetrUSS Capabilities for S and C Applications

TetrUSS is a suite of loosely coupled computational fluid dynamics software that is packaged into a complete flow analysis system. The system components consist of tools for geometry setup, grid generation, flow solution, visualization, and various utilities tools. Development began in 1990 and it has evolved into a proven and stable system for Euler and Navier-Stokes analysis and design of unconventional configurations. It is 1) well developed and validated, 2) has a broad base of support, and 3) is presently is a workhorse code because of the level of confidence that has been established through wide use. The entire system can now run on linux or mac architectures. In the following slides, I will highlight more of the features of the VGRID and USM3D codes.

Frink, Neal T.↗

A data base for three-dimensional all-interference code evaluation

A validation of a measured boundary condition technique was carried out to demonstrate the feasibility of a wall interference assessment/correction (WIAC) system. An experimental evaluation was also carried out to compare performances of various techniques, to define the number of necessary boundary measurements for accurate assessment/corrections and to define the envelope of test conditions for which accurate assessment/corrections are achieved. The relative merits of a WIAC system and an adaptive wall tunnel are compared. The measurement surface boundary data is performed with a system of two rotating pipes. These pipes sweep out a cylindrical measurement surface near the tunnel walls, approximately one inch from the wall at the closest point. The experimental model was specially designed and fabricated for the adaptive wall experiments. The model is a wing/tail/body configuration with swept lifting surface. The boundary data taken in Tunnel 1T with the rotating pipe system has been shown to offer several attractive features for WIAC code evaluation. Good spatial resolution of measurements is achieved and measurements are made upstream and downstream of the model. Also, two velocity components are determined.

Sickles, W. L.↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-02: Automated Systematic Quality Assurance Program for Radiation Oncology Information System Upgrades

Purpose: To: (1) describe an independent, automated, systematic software-based protocol for verifying clinical data accuracy/integrity for mitigation of data corruption/loss risks following radiation oncology information system (ROIS) upgrades; and (2) report on application of this approach in an academic/community practice environment. Methods: We propose a robust approach to perform quality assurance on the ROIS after an upgrade, targeting four data sources: (1) ROIS relational database; (2) ROIS DICOM interface; (3) ROIS treatment machine data configuration; and (4) ROIS-generated clinical reports. We investigated the database schema for differences between pre-/post-upgrade states. Paired DICOM data streams for the same object (such as RT-Plan/Treatment Record) were compared between pre-/post-upgrade states for data corruption. We examined machine configuration and related commissioning data files for changes and corruption. ROIS-generated treatment appointment and treatment parameter reports were compared to ensure patient encounter and treatment plan accuracy. This protocol was supplemented by an end-to-end clinical workflow test to verify essential ROI functionality and integrity of components interfaced during patient care chain of activities. We describe the implementation of this protocol during a Varian ARIA system upgrade at our clinic. Results: We verified 1,638 data tables with 2.4 billion data records. For 222 under-treatment patients, 605 DICOM RT plans and 13,480 DICOM treatment records retrieved from the ROIS DICOM interface were compared, with no differences in fractions, doses delivered, or treatment parameters. We identified 82 new data tables and 78 amended/deleted tables consistent with the upgrade. Reports for 5,073 patient encounters over a 2-week horizon were compared and were identical to those before the upgrade. Content in 12,237 xml machine files was compared, with no differences identified. Conclusion: An independent QA/validation approach for ROIS upgrades was developed and implemented at our clinic. The success of this approach ensures a robust QA of ROIS upgrades without manual paper/electronic checks and associated intensive labor.

60 APPLIED LIFE SCIENCES↗

Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

Miller, Thomas Martin↗

Methods for obtaining and reducing experimental droplet impingement data on arbitrary bodies

Experimental water droplet impingement data are used to validate particle trajectory computer codes used in the analysis and certification of aircraft de-icing/anti-icing systems. Water droplet impingement characteristics of aerodynamic surfaces are usually obtained from wind-tunnel dye tracer experiments. This paper presents a dye tracer method for measuring water droplet impingement characteristics on arbitrary geometries and a new data reduction method, based on laser reflectance measurements, for extracting impingement data. Extraction of impingement data has been a very time-consuming process in the past. The new data reduction method developed is at least an order of magnitude more efficient than the method previously used. The accuracy of the method is discussed and results obtained are presented.

Papadakis, Michael↗

Analysis Capability and Data Needs Identified During the Evaluation of the SILENE CAAS Benchmarks

In October 2010, a series of benchmark experiments was conducted at the Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA to create three benchmarks for verification and validation of radiation transport codes, as well as evaluated nuclear data, used to analyze criticality accident alarm systems (CAASs). Many preliminary details of these experiments and their evaluation have been discussed in previous publications. The first benchmark evaluation was published in 2015, and the second and third evaluations will be published at the end of 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis Capability and Data Needs Identified During the Evaluation of the SILENE CAAS Benchmarks

In October 2010, a series of benchmark experiments was conducted at the Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA to create three benchmarks for verification and validation of radiation transport codes, as well as evaluated nuclear data, used to analyze criticality accident alarm systems (CAASs). Many preliminary details of these experiments and their evaluation have been discussed in previous publications. The first benchmark evaluation was published in 2015, and the second and third evaluations will be published at the end of 2016. During evaluation of the three benchmarks, differences were observed between the measured and calculated benchmark values, which was not surprising. Evaluators spent a great deal of time identifying the sources of these differences. This paper presents two of the most important and clearly identifiable differences, which the authors identify as needs for the criticality safety and shielding communities. The first need is the capability to easily produce and transport delayed neutrons and gammas within existing radiation transport codes without coupling to a separate decay and depletion code. The second need is to fill in missing gamma production data in the evaluated nuclear data libraries. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RF-driven advanced modes of ITER operation

The impact of the Radio Frequency heating and current drive systems on the ITER advanced scenarios is analyzed by means of the CRONOS suite of codes for integrated tokamak modelling. As a first step, the code is applied to analyze a high power advanced scenario discharge of JET in order to validate both the heating and current drive modules and the overall simulation procedure. Then, ITER advanced scenarios, based on Radio Frequency systems, are studied on the basis of previous results. These simulations show that both hybrid and steady-state scenarios could be possible within the ITER specifications, using RF heating and current drive only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of the intrinsic spatial efficiency method for non cylindrical homogeneous sources using MC simulation

The Monte Carlo simulation of the gamma spectroscopy systems is a common practice in these days. The most popular softwares to do this are MCNP and Geant4 codes. The intrinsic spatial efficiency method is a general and absolute method to determine the absolute efficiency of a spectroscopy system for any extended sources, but this was only demonstrated experimentally for cylindrical sources. Due to the difficulty that the preparation of sources with any shape represents, the simplest way to do this is by the simulation of the spectroscopy system and the source. In this work we present the validation of the intrinsic spatial efficiency method for sources with different geometries and for photons with an energy of 661.65 keV. In the simulation the matrix effects (the auto-attenuation effect) are not considered, therefore these results are only preliminaries. The MC simulation is carried out using the FLUKA code and the absolute efficiency of the detector is determined using two methods: the statistical count of Full Energy Peak (FEP) area (traditional method) and the intrinsic spatial efficiency method. The obtained results show total agreement between the absolute efficiencies determined by the traditional method and the intrinsic spatial efficiency method. The relative bias is lesser than 1% in all cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Safety aspects of dry spent fuel storage and spent fuel management

As with the storage of all radioactive materials, the storage of spent nuclear fuel (SF) and high-level radioactive waste (HLW) must conform to safety requirements. Safety aspects like safe enclosure of radioactive materials, safe removal of decay heat, nuclear criticality safety and avoidance of unnecessary radiation exposure must be achieved throughout the storage period. The implementation of these safety requirements can be achieved by dry storage of SF and HLW in casks as well as in other systems such as dry vault storage systems or spent fuel pools, where the latter is neither a dry nor a passive system. After the events of Fukushima, the advantages of passively and inherently safe dry storage systems have become more obvious. TUV and BAM, who work as independent experts for the competent authorities, present the licensing process for sites and casks and inform about spent nuclear fuel management and issues concerning dry storage of spent nuclear fuel, based on their long experience in these fields. All safety relevant issues like safe enclosure, shielding, removal of the decay heat or behavior of cask and building under accident conditions are checked and validated with state-of-the-art methods and computer codes before the license approval. It is shown how dry storage systems can ensure the compliance with the mentioned safety criteria over a long storage period. Exemplarily, the process of licensing, erection and operation of selected German dry storage facilities is presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation and Testing of ENDF/B-VII Decay Data

The nuclear decay library developed for the ORIGEN code was upgraded from ENDF/B-VI.8 to -VII.0 and released in the SCALE nuclear modeling and simulation code system in 2011. Experience with the ENDF/B-VII.0 library identified serious errors and performance issues in the evaluated decay sublibrary. Initially, errors were identified in the decay scheme for the 238U series, leading to large discrepancies in the gamma emission rate for uranium. Further testing of the fission product decay data revealed significant performance issues with ENDF/B-VII.0 relative to the previous release of ENDF/B-VI. To address the performance issues, the decay data library in SCALE was upgraded to ENDF/B-VII.1 and released as an update for users in 2013. This paper describes the practical impact of the ENDF/B-VII.0 decay data performance issues on common code applications, and the validation and testing performed on the updated ORIGEN libraries developed from the ENDF/B-VII.1 sublibrary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Shock Position Control for Mode Transition in a Turbine Based Combined Cycle Engine Inlet Model

A dual flow-path inlet system is being tested to evaluate methodologies for a Turbine Based Combined Cycle (TBCC) propulsion system to perform a controlled inlet mode transition. Prior to experimental testing, simulation models are used to test, debug, and validate potential control algorithms. One simulation package being used for testing is the High Mach Transient Engine Cycle Code simulation, known as HiTECC. This paper discusses the closed loop control system, which utilizes a shock location sensor to improve inlet performance and operability. Even though the shock location feedback has a coarse resolution, the feedback allows for a reduction in steady state error and, in some cases, better performance than with previous proposed pressure ratio based methods. This paper demonstrates the design and benefit with the implementation of a proportional-integral controller, an H-Infinity based controller, and a disturbance observer based controller.

Csank, Jeffrey T.↗

A Turbine Based Combined Cycle Engine Inlet Model and Mode Transition Simulation Based on HiTECC Tool

An inlet system is being tested to evaluate methodologies for a turbine based combined cycle propulsion system to perform a controlled inlet mode transition. Prior to wind tunnel based hardware testing of controlled mode transitions, simulation models are used to test, debug, and validate potential control algorithms. One candidate simulation package for this purpose is the High Mach Transient Engine Cycle Code (HiTECC). The HiTECC simulation package models the inlet system, propulsion systems, thermal energy, geometry, nozzle, and fuel systems. This paper discusses the modification and redesign of the simulation package and control system to represent the NASA large-scale inlet model for Combined Cycle Engine mode transition studies, mounted in NASA Glenn s 10- by 10-Foot Supersonic Wind Tunnel. This model will be used for designing and testing candidate control algorithms before implementation.