Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Electrospraying deposition and characterization of potassium chloride targets for nuclear science measurements

Natural and isotopically enriched KCl targets were prepared using specially formulated KCl solutions, deposited by electrospraying on thin (1.5 μm) gold backings, followed by a short annealing in a preheated (350-450 °C) furnace. Various techniques, such as X-ray fluorescence (XRF), scanning electron microscopy (SEM) imaging, and energy-dispersive X-ray spectroscopy (EDS), were used to characterize the produced targets. A white neutron beam at the Los Alamos Neutron Science Center (LANSCE) facility was also used to verify the estimated atomic percentages of the enriched 40 KCl targets. KCl was deposited relatively uniformly as large particles rather than films on the gold surface. As a result, this method can be broadly extended to make stable targets that are difficult to produce with other methods and more exotic radioactive targets required for research in fundamental sciences and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Th IV –Desferrioxamine: characterization of a fluorescent bacterial probe

Diversifying our ability to guard against emerging pathogenic threats is essential for keeping pace with global health challenges, including those presented by drug-resistant bacteria. Some modern diagnostic and therapeutic innovations to address this challenge focus on targeting methods that exploit bacterial nutrient sequestration pathways, such as the desferrioxamine (DFO) siderophore used by Staphylococcus aureus (S. aureus) to sequester Fe III . Building on recent studies that have shown DFO to be a versatile vehicle for chemical delivery, we show proof-of-principle that the Fe III sequestration pathway can be used to deliver a potential radiotherapeutic. Our approach replaces the FeIII nutrient sequestered by H 4 DFO + with Th IV and made use of a common fluorophore, FITC, which we covalently bonded to DFO to provide a combinatorial probe for simultaneous chelation paired with imaging and spectroscopy, H 3 DFO_FITC. Combining insight provided from FITC-based imaging with characterization by NMR spectroscopy, we demonstrated that the fluorescent DFO_FITC conjugate retained the Th IV chelation properties of native H4DFO+. Fluorescence microscopy with both [Th(DFO_FITC)] and [Fe(DFO_FITC)] complexes showed similar uptake by S. aureus and increased intercellular accumulation as compared to the FITC and unchelated H 3 DFO_FITC controls. Collectively, these results demonstrate the potential for the newly developed H 3 DFO_FITC conjugate to be used as a targeting vector and bacterial imaging probe for S. aureus. The results presented within provide a framework to expand H 4 DFO + and H 3 DFO_FITC to relevant radiotherapeutics (like 227Th).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Eye Tracking to Elucidate the Mechanisms Underlying Stimulation-Enhanced Visual Target Detection

Transcranial direct current stimulation (tDCS) is a noninvasive form of brain stimulation that involves passing a weak electrical current between electrodes on the scalp to modulate underlying neural tissue. TDCS has been shown to modulate cognition in a variety of domains, including memory, attention, and visual processing. Prior work from our laboratory has shown positive effects of tDCS on learning to detect target objects hidden in complex naturalistic visual scenes and learn rules for categorizing images, though the mechanism for these benefits remains unknown. One possibility is that tDCS optimizes visual search by modulating visual attention or via the reduction in search errors. One method of quantifying visual attention is to use eye tracking to record search patterns to determine if and how visual search is adjusted under verum stimulation conditions. Eye tracking data allows classification of errors into error types, including sampling errors (failing to look in the relevant region), recognition errors (looking at the critical portion of a scene, but failing to recognize it as such as evidenced by visual fixation), and decision-making errors (fixating on the relevant portion of a scene, but making the wrong determination). Our results indicate that the benefit tDCS confers on visual search for targets stems from the reduction in decision-making errors when targets are present (Cohen’s d = 0.86). Also reported is a replication of previous findings showing a tDCS-dependent improvement in learning this task, learning score (Cohen’s d = 0.88); d’ (Cohen’s d = 1.00). This provides support for moving tDCS into the application space by pairing it with analysts who are concerned with the type of search error that is corrected via stimulation.

attention↗

X-ray multiphoton-induced Coulomb explosion images complex single molecules

Following structural dynamics in real time is a fundamental goal towards a better understanding of chemical reactions. Recording snapshots of individual molecules with ultrashort exposure times is a key ingredient towards this goal, as atoms move on femtosecond (10 -15 s) timescales. For condensed-phase samples, ultrafast, atomically resolved structure determination has been demonstrated using X-ray and electron diffraction. Pioneering experiments have also started addressing gaseous samples. However, they face the problem of low target densities, low scattering cross sections and random spatial orientation of the molecules. Therefore, obtaining images of entire, isolated molecules capturing all constituents, including hydrogen atoms, remains challenging. Here we demonstrate that intense femtosecond pulses from an X-ray free-electron laser trigger rapid and complete Coulomb explosions of 2-iodopyridine and 2-iodopyrazine molecules. We obtain intriguingly clear momentum images depicting ten or eleven atoms, including all the hydrogens, and thus overcome a so-far impregnable barrier for complete Coulomb explosion imaging—its limitation on molecules consisting of three to five atoms. In combination with state-of-the-art multi-coincidence techniques and elaborate theoretical modelling, this allows tracing ultrafast hydrogen emission and obtaining information on the result of intramolecular electron rearrangement. Our work represents an important step towards imaging femtosecond chemistry via Coulomb explosion.

74 ATOMIC AND MOLECULAR PHYSICS↗

DNA origami protection and molecular interfacing through engineered sequence-defined peptoids

DNA nanotechnology has established approaches for designing programmable and precisely controlled nanoscale architectures through specific Watson−Crick base-pairing, molecular plasticity, and intermolecular connectivity. In particular, superior control over DNA origami structures could be beneficial for biomedical applications, including biosensing, in vivo imaging, and drug and gene delivery. However, protecting DNA origami structures in complex biological fluids while preserving their structural characteristics remains a major challenge for enabling these applications. Here, we developed a class of structurally well-defined peptoids to protect DNA origamis in ionic and bioactive conditions and systematically explored the effects of peptoid architecture and sequence dependency on DNA origami stability. The applicability of this approach for drug delivery, bioimaging, and cell targeting was also demonstrated. A series of peptoids (PE1–9) with two types of architectures, termed as “brush” and “block,” were built from positively charged monomers and neutral oligo-ethyleneoxy monomers, where certain designs were found to greatly enhance the stability of DNA origami. Through experimental and molecular dynamics studies, we demonstrated the role of sequence-dependent electrostatic interactions of peptoids with the DNA backbone. We showed that octahedral DNA origamis coated with peptoid (PE2) can be used as carriers for anticancer drug and protein, where the peptoid modulated the rate of drug release and prolonged protein stability against proteolytic hydrolysis. Finally, we synthesized two alkyne-modified peptoids (PE8 and PE9), conjugated with fluorophore and antibody, to make stable DNA origamis with imaging and cell-targeting capabilities. Our results demonstrate an approach toward functional and physiologically stable DNA origami for biomedical applications.

36 MATERIALS SCIENCE↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A VR-based volumetric medical image segmentation and visualization system with natural human interaction

Volume rendering produces informative two-dimensional (2D) images from a 3-dimensional (3D) volume. It highlights the region of interest and facilitates a good comprehension of the entire data set. However, volume rendering faces a few challenges. First, a high-dimensional transfer function is usually required to differentiate the target from its neighboring objects with subtle variance. Unfortunately, designing such a transfer function is a strenuously trial-and-error process. Second, manipulating/visualizing a 3D volume with a traditional 2D input/output device suffers dimensional limitations. To address all the challenges, we design NUI-VR 2 , a natural user interface-enabled volume rendering system in the virtual reality space. NUI-VR 2 marries volume rendering and interactive image segmentation. It transforms the original volume into a probability map with image segmentation. A simple linear transfer function will highlight the target well in the probability map. More importantly, we set the entire image segmentation and volume rendering pipeline in an immersive virtual reality environment with a natural user interface. NUI-VR 2 eliminates the dimensional limitations in manipulating and perceiving 3D volumes and dramatically improves the user experience.

42 ENGINEERING↗

Radiation and heat transport in divergent shock–bubble interactions

Shock–bubble interactions (SBIs) are important across a wide range of physical systems. In inertial confinement fusion, interactions between laser-driven shocks and micro-voids in both ablators and foam targets generate instabilities that are a major obstacle in achieving ignition. Experiments imaging the collapse of such voids at high energy densities (HED) are constrained by spatial and temporal resolution, making simulations a vital tool in understanding these systems. In this study, we benchmark several radiation and thermal transport models in the xRAGE hydrodynamic code against experimental images of a collapsing mesoscale void during the passage of a 300 GPa shock. We also quantitatively examine the role of transport physics in the evolution of the SBI. This allows us to understand the dynamics of the interaction at timescales shorter than experimental imaging framerates. We find that all radiation models examined reproduce empirical shock velocities within experimental error. Radiation transport is found to reduce shock pressures by providing an additional energy pathway in the ablation region, but this effect is small (∼1% of total shock pressure). Employing a flux-limited Spitzer model for heat conduction, we find that flux limiters between 0.03 and 0.10 produce agreement with experimental velocities, suggesting that the system is well-within the Spitzer regime. Higher heat conduction is found to lower temperatures in the ablated plasma and to prevent secondary shocks at the ablation front, resulting in weaker primary shocks. Finally, we confirm that the SBI-driven instabilities observed in the HED regime are baroclinically driven, as in the low energy case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding asymmetries using integrated simulations of capsule implosions in low gas-fill hohlraums at the National Ignition Facility

Current capsule implosions at the National Ignition Facility (NIF) using high-density-carbon ablators and laser energies close to 2 MJ have shown neutron yields in excess of 50 kJ. Improving on this performance requires understanding of the different degradation mechanisms. For many NIF implosions, nuclear diagnostic signatures have inferred residual hot-spot velocities that correlate with fuel areal density variations consistent with a low-order mode-1 asymmetry. A current working hypothesis attributes these asymmetries to a combination of beam to beam variations in the laser delivery and possibly coupling to target features, such as the diagnostic holes needed for x-ray imaging. Recently, a new source has been identified, thickness variation in the ablator shell. To gain better understanding and eventually mitigate the causes of <ρR> asymmetries, 3D integrated simulations using the actual delivered laser powers are needed. To capture the effect of the diagnostic holes (DHs) using direct numerical simulation would require significantly large computational resources. Instead, our 3D simulations make use of a subgrid model developed using highly-resolved 2D simulations that include several details of the DH engineering complexity. Simulations of NIF shots using hohlraums without DHs, to isolate the effect of beam-to-beam variations, reproduce fairly well the observed nuclear diagnostic signatures. Similarly, reasonable agreement between data and simulations is also obtained in the presence of diagnostic holes. To account for the remaining discrepancies a sensitivity study of ablator thickness variation showed that 1% thickness asymmetries are comparable in effect to 1% peak drive mode-1 asymmetries. Furthermore, this study identified sensitivity to variations in the imbedded doped layer (needed to shield the DT ice from the high energy x-rays generated in the hohlraum) thickness even when the inner and outer surface of the ablator are perfectly spherical.

radiation hydrodynamics↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epithermal and Fast Neutron Radiography Facility HFIR Futures – Enhanced Capabilities Series (Vol. 8)

The Sustaining and Enhancing Nuclear Science Initiative at Oak Ridge National Laboratory (ORNL) was created to explore potential enhancements to scientific capabilities in the High Flux Isotope Reactor as part of a reactor pressure vessel replacement project. One proposed scientific enhancement included creation of an epithermal and fast neutron radiography station on the HB-3 beam tube with the capability to image highly radioactive specimens such as irradiated nuclear fuel rods, isotope production targets, or spallation neutron target materials. This document summarizes findings and recommendations from a working group of ORNL staff tasked with conceptualizing such a facility and includes a background of similar instruments at other research facilities, technical specifications, and an estimate of procurement cost and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation Study of Monoenergetic Photon Source LiDAR System Performance for Emergency Response Applications

The following report summarizes the results of a Monte Carlo simulation and modeling study of the Lawrence Berkeley National Laboratory’s (LBL) Monoenergetic Photon Source (MPS) as part of a high-energy LiDAR system for use in emergency response applications. A set of image quality indicators (IQI) and nonsensitive phantoms or generalized surrogates for search targets have been identified for use in the planned measurement campaign at the Berkeley Lab Laser Accelerator (BELLA) Center toward the end FY2023. These items were modeled and the time-of-flight (TOF) spectral responses following irradiation were calculated for a set of varying operating conditions. The goal of this study was to both predict the LiDAR system performance as well as determine if minor modifications to the IQI and phantom designs were required before fabrication. It was found that the IQI and target designs both overlap and extend towards the limit of performance of the system and are thus suitable for the final project measurement campaign.

43 - PARTICLE ACCELERATORS↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral studies of soft x-ray radiation of laser-produced plasma of various target materials in a wide spectral range

Here, the work is devoted to experimental study of soft X-ray radiation spectra of laser produced plasma in a wide spectral range 5–100 Å at the “Kamerton” facility (GPI) with pulse duration 70 ps, pulse energy 1–5 J, wavelength 0.53 microns at which the laser intensity (power flux density) of 7×10 14 – 3.5×10 15 W/cm 2 was achieved. A spectrograph was used, which had transmission diffraction gratings with a ratio of the elementary gap to the period of the structure of 0.25 and 0.41. Detection was performed on both UV-4 X-ray photo film and Fuji TR fluorescent imaging plate. Solid samples from Al, Si, Ti, Cu, Ta and W were used as targets. The ionization states of the plasma corresponding to various electron temperatures were calculated, which made it possible to estimate the electron temperature by comparison these calculation results with the experimentally obtained spectra. The estimated electron temperature, which depends on the laser pulse energy and the target material, varied within the range of 100–450 eV. To verify the correctness of the temperature estimations obtained by such comparison a numerical simulation of plasma radiation was carried out by the use of PrismSPECT computer program. It was found that the results of this simulation are in a good agreement with estimations on the base of experimentally obtained spectra. The analysis of these spectra showed that tantalum, tungsten or titanium targets are the best candidates among the tested ones for the use of laser produced plasma as a radiation source in the "water window" spectral range (23–44 Å) for applications in biology and medicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comprehensive single-shot biophysical cytometry using simultaneous quantitative phase imaging and Brillouin spectroscopy

Abstract Single-cell analysis, or cytometry, is a ubiquitous tool in the biomedical sciences. Whereas most cytometers use fluorescent probes to ascertain the presence or absence of targeted molecules, biophysical parameters such as the cell density, refractive index, and viscosity are difficult to obtain. In this work, we combine two complementary techniques—quantitative phase imaging and Brillouin spectroscopy—into a label-free image cytometry platform capable of measuring more than a dozen biophysical properties of individual cells simultaneously. Using a geometric simplification linked to freshly plated cells, we can acquire the cellular diameter, volume, refractive index, mass density, non-aqueous mass, fluid volume, dry volume, the fractional water content of cells, both by mass and by volume, the Brillouin shift, Brillouin linewidth, longitudinal modulus, longitudinal viscosity, the loss modulus, and the loss tangent, all from a single acquisition, and with no assumptions of underlying parameters. Our methods are validated across three cell populations, including a control population of CHO-K1 cells, cells exposed to tubulin-disrupting nocodazole, and cells under hypoosmotic shock. Our system will unlock new avenues of research in biophysics, cell biology, and medicine.

Steelman, Zachary A.↗

Precise transcript targeting by CRISPR-Csm complexes

Robust and precise transcript targeting in mammalian cells remains a difficult challenge using existing approaches due to inefficiency, imprecision and subcellular compartmentalization. Here we show that the clustered regularly interspaced short palindromic repeats (CRISPR)-Csm complex, a multiprotein effector from type III CRISPR immune systems in prokaryotes, provides surgical RNA ablation of both nuclear and cytoplasmic transcripts. As part of the most widely occurring CRISPR adaptive immune pathway, CRISPR-Csm uses a programmable RNA-guided mechanism to find and degrade target RNA molecules without inducing indiscriminate trans-cleavage of cellular RNAs, giving it an important advantage over the CRISPR-Cas13 family of enzymes. Using single-vector delivery of the Streptococcus thermophilus Csm complex, we observe high-efficiency RNA knockdown (90–99%) and minimal off-target effects in human cells, outperforming existing technologies including short hairpin RNA- and Cas13-mediated knockdown. We also find that catalytically inactivated Csm achieves specific and durable RNA binding, a property we harness for live-cell RNA imaging. These results establish the feasibility and efficacy of multiprotein CRISPR-Cas effector complexes as RNA-targeting tools in eukaryotes.

59 BASIC BIOLOGICAL SCIENCES↗

Epithermal Neutron Resonance Analysis Using a Compact D-T Generator

Nuclear material identification and isotopic composition analysis are important capabilities for safeguards and the verification of nuclear arms control and nonproliferation treaties. Epithermal neutron resonance imaging has been proposed for spent fuel assay measurements, and the development of a mobile neutron imaging system could provide such a tool for on-site applications. This technique is highly sensitive to isotopes of interest for safeguards applications (e.g. 235,238 U, 238,239,240 Pu) and yields unique transmission spectra for a target containing actinides and some mid- and high-Z elements. Paired with a position-sensitive neutron detector, such a system could provide spatial information of the target isotopic composition. Recent progress in the development of high intensity neutron sources could make mobile epithermal neutron imaging designs increasingly feasible to serve as a tool for nuclear inspectors. In this work, Monte Carlo (MC) simulations were performed to further optimize a previous design for an epithermal neutron resonance-based analysis apparatus using a D-T portable neutron generator. Additionally, experimental work is being performed to test the feasibility of this method. The MC simulations of moderation time distributions for different moderator compositions and thicknesses were measured to provide a multi-group correction for neutron time-of-flight energy reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗