Failure processes within ceramic coatings at high temperatures

Plasma sprayed coatings have a complex structure which is produced by the overlaying of many molten or semi-molten particles in the diameter range of 20 to 120 microns. The failure behavior of coatings has been characterized by using acoustic emission (AE) methodology. Coatings of NiCrAlY bond coat with a zirconia-12 wt pct yttria overlay were applied to disk-shaped specimens of U-700 alloy. A waveguide of 1-mm diameter platinum was TlG welded to the specimen and allowed it to be suspended in a tubular furnace. The specimen was thermally cycled to 1150 C and the AE monitored. Analyses have been carried out with the aim of establishing parameters which are related to the crack size population. These studies have been used to postulate types of cracking mechanisms which may occur in plasma sprayed coatings during thermal cycling. It is shown that microcracking gave rise to a large amount of AE. However, this coating still survived more thermal cycles than a coating which exhibited macrocracking events.

Berndt, Christopher↗

Simplified micromechanical equations for thermal residual stress analysis of coated fiber composites

The fabrication of metal matrix composites poses unique problems to the materials engineer. The large thermal expansion coefficient mismatch between the fiber and matrix leads to high tensile residual stresses at the fiber/matrix interface which could lead to premature matrix cracking during cooldown. Fiber coating could be used to reduce thermal residual stresses. A simple closed-form analysis, based on a three-phase composite cylinder model, was developed to calculate thermal residual stresses in a fiber/interface/matrix system. Guidelines, in the form of simple equations, for the selection of appropriate material properties of the fiber coating, were also derived to minimize thermal residual stresses in the matrix during fabrication.

Naik, Rajiv A.↗

Oxidation of Carbon Fibers in a Cracked Ceramic Matrix Composite Modeled as a Function of Temperature

The oxidation model simulates the oxidation of the reinforcing carbon fibers within a ceramic matrix composite material containing as-fabricated microcracks. The physics-based oxidation model uses theoretically and experimentally determined variables as input for the model. The model simulates the ingress of oxygen through microcracks into a two-dimensional plane within the composite material. Model input includes temperature, oxygen concentration, the reaction rate constant, the diffusion coefficient, and the crack opening width as a function of the mechanical and thermal loads. The model is run in an iterative process for a two-dimensional grid system in which oxygen diffuses through the porous and cracked regions of the material and reacts with carbon in short time steps. The model allows the local oxygen concentrations and carbon volumes from the edge to the interior of the composite to be determined over time. Oxidation damage predicted by the model was compared with that observed from microstructural analysis of experimentally tested composite material to validate the model for two temperatures of interest. When the model is run for low-temperature conditions, the kinetics are reaction controlled. Carbon and oxygen reactions occur relatively slowly. Therefore, oxygen can bypass the carbon near the outer edge and diffuse into the interior so that it saturates the entire composite at relatively high concentrations. The kinetics are limited by the reaction rate between carbon and oxygen. This results in an interior that has high local concentrations of oxygen and a similar amount of consumed carbon throughout the cross section. When the model is run for high-temperature conditions, the kinetics are diffusion controlled. Carbon and oxygen reactions occur very quickly. The carbon consumes oxygen as soon as it is supplied. The kinetics are limited by the relatively slow rate at which oxygen is supplied in comparison to the relatively fast rate at which carbon and oxygen reactions occur. This results in a sharp gradient in oxygen concentration from the edge where it is supplied to the nearest source of carbon, which is where the oxygen is quickly consumed. A moving reaction front is seen in which the outlaying carbon is consumed before the next inner layer of carbon begins to react.

Halbig, Michael C.↗

Combined ambient vibration and surface displacement measurements for improved progressive failure monitoring at a toppling rock slab in Utah, USA

Seismic resonance and surface displacement measurements can be implemented in tandem to improve landslide characterization and progressive failure monitoring. Crack aperture data are frequently used in rock slope stability monitoring and often exhibit recognizable trends prior to failure, such as accelerated crack opening. Alternatively, ambient resonance data offer multiple parameters including modal frequencies, damping, and polarization that can be monitored alongside crack aperture and may respond differently to environmental forcings and complex failure evolution. We analyzed data from continuous ambient vibration monitoring and concomitant crack aperture measurements at the Courthouse Mesa instability, a large toppling sandstone slab in Utah, USA. Three years of data revealed crack aperture increases of 2–4 mm/year with no clearly detectable irreversible changes in modal parameters, including frequency. Annually, frequency and displacement varied by 29% and 19% of the mean, respectively, with average and maximum daily frequency fluctuations of 6.5% and 16%, respectively. These reversible cyclic changes were primarily temperature-driven, but annually, frequency was in-phase with temperature whereas crack aperture lagged temperature changes by ~37 days. Polarization and damping also varied seasonally but were less strongly correlated with temperature. Conceptual 3D finite element modeling demonstrated consistent frequency decreases associated with crack propagation but variable changes in crack aperture measured at a single point; i.e., crack propagation did not always result in increased crack opening but always generated a resonance frequency decrease. Taken together, our data suggest a possible thermal wedging-ratcheting mechanism at the Courthouse Mesa instability, where annual thermoelastic crack closure is impeded by debris infill but the absence of downward crack propagation during the monitoring period is evidenced by no permanent resonance frequency changes. Our study demonstrates that combined seismic resonance and crack aperture data provide an improved description of rock slope instability behavior, supporting refined characterization and monitoring of changes accompanying progressive failure.

58 GEOSCIENCES↗

Two-layer thermal barrier coating. I - Effects of composition and temperature on oxidation behavior and failure

The effects of 21 bond and 2 ceramic coating compositions on the specific mass gain, internal crack location at failure, and life of a two-layer thermal barrier coating (TBC) were studied by cyclic testing in a furnace. MAR-M 200 + Hf alloy specimens were completely coated with bond and thermal barrier (ceramic) coatings. Both coatings were applied by air plasma spray deposition. Cyclic test data were obtained at 1110, 1160, and 1220 deg C. The data show that the specific mass gain and the TBC life are significantly affected by the composition of the bond coating and the temperature and only slightly affected by the composition of the ceramic coating.

Stecura, Stephan↗

Compositionally complex doping for zero-strain zero-cobalt layered cathodes

We report the high volatility of the price of cobalt and the geopolitical limitations of cobalt mining have made the elimination of Co a pressing need for the automotive industry. Owing to their high energy density and low-cost advantages, high-Ni and low-Co or Co-free (zero-Co) layered cathodes have become the most promising cathodes for next-generation lithium-ion batteries. However, current high-Ni cathode materials, without exception, suffer severely from their intrinsic thermal and chemo-mechanical instabilities and insufficient cycle life. Here, in this paper, by using a new compositionally complex (high-entropy) doping strategy, we successfully fabricate a high-Ni, zero-Co layered cathode that has extremely high thermal and cycling stability. Combining X-ray diffraction, transmission electron microscopy and nanotomography, we find that the cathode exhibits nearly zero volumetric change over a wide electrochemical window, resulting in greatly reduced lattice defects and local strain-induced cracks. In-situ heating experiments reveal that the thermal stability of the new cathode is significantly improved, reaching the level of the ultra-stable NMC-532. Owing to the considerably increased thermal stability and the zero volumetric change, it exhibits greatly improved capacity retention. This work, by resolving the long-standing safety and stability concerns for high-Ni, zero-Co cathode materials, offers a commercially viable cathode for safe, long-life lithium-ion batteries and a universal strategy for suppressing strain and phase transformation in intercalation electrodes.

25 ENERGY STORAGE↗

Evaluation of In-Situ AM Process Monitoring Techniques and Potential for Detecting Process Anomalies and Undesirable Microstructures

The US Department of Energy’s Advanced Materials and Manufacturing Technologies (AMMT) program is pursuing rapid qualification of new materials for fabrication of nuclear relevant components using advanced manufacturing techniques. Particular interest is placed on code-qualifying stainless steel (SS) 316H processed by laser powder bed fusion (LPBF) additive manufacturing. A paradigm that incorporates data from in-situ sensing during the printing, ex-situ characterization, and advanced artificial intelligence–based models was established under the Transformation Challenge Reactor (TCR) program to develop a pedigree for each fabricated component that could be tracked from the feedstock to the component’s release for application. Under the TCR program, the Peregrine software was developed as a tool for incorporating the vast amounts of in-situ and ex-situ characterization data collected; all data stored on a rapidly growing digital platform. The digital platform allows for users to link site-specific process anomalies to the macro- and microstructure. The platform will eventually be able to predict component performance, which will be crucial to qualifying materials and components in risk-averse industries such as those supporting and building nuclear reactors. Current in-situ process monitoring techniques that are already integrated with software like Peregrine are advantageous for identifying process anomalies including powder spatter, component edge swelling, recoating-build interactions, and so on. However, additional data are required to fully predict the resulting microstructures needed for identifying relationships to component performance. The rapid cooling rates observed in LPBF are some of the highest of any bulk manufacturing process, resulting in heterogenous microstructures and typically causing anisotropy in mechanical properties. Moreover, evolved residual thermal stresses are high, which can cause severe defects such as delamination or cracking. Therefore, other in-situ monitoring methods are warranted for exploration to measure and map the thermal history, and potentially the stress state, of each build. This report summarizes different in-situ monitoring strategies proposed for LPBF with a focus on the more developed sensor systems. Novel capabilities for measuring melt pool temperatures are also addressed to better inform modeling efforts.

36 MATERIALS SCIENCE↗

Crack mitigation and wear performance of high-strength steel coatings deposited by high-speed laser cladding

This article investigates the fabrication of defect-free Rockit® 606, a high‑carbon, vanadium- and chromium-enriched precipitation-hardening martensitic steel coating, using high-speed laser cladding (HSLC). Compared to conventional laser cladding, HSLC offers higher deposition efficiency, improved coating quality, minimal thermal distortion, and a reduced heat-affected zone. Various HSLC parameters—including laser power, travel speed, powder feed rate, and overlap distance—were optimized to achieve superior coating properties. Microstructural analysis revealed solidification cracks in coatings deposited on carburized steel, regardless of processing parameters. However, preheating the substrate to 250 °C effectively eliminated cracking by reducing thermal gradients. The coatings exhibited a columnar dendritic microstructure, with coarser dendrites near the substrate and finer dendrites towards the surface. Hardness measurements confirmed that all coatings significantly exceeded the industry-specified threshold of 60 HRC, with preheating having minimal effect on overall hardness distribution. Reciprocating sliding wear tests demonstrated a substantial improvement in wear resistance for the defect-free HSLC coatings compared to baseline carburized steel. These findings underscore the potential of HSLC for producing high-performance, wear-resistant coatings suitable for industrial applications.

36 MATERIALS SCIENCE↗

Stress Relaxation Cracking of Alloys at Temperatures Higher Than 540°C

Type 347H stainless steel (347H SS), used in commercial concentrating solar power (CSP) thermal energy storage to store solar-salt at a temperature of 565°C, has been reported in the literature to be susceptible to stress-relaxation cracking (SRC). The welded heat-affected zone (HAZ) and fusion zone (FZ) of 347H SS, particularly in thick sections, are known to be susceptible to failure during post-weld heat treatment (reheat cracking). SRC could also occur after months or years under an elevated-temperature service environment. Two conditions must be present for failure to occur in the HAZ and/or FZ: 1) a modified or sensitized microstructure and 2) sufficiently high tensile residual stresses present at the elevated service temperature. The overarching goal of this project is to recommend SRC mitigation protocols to avoid susceptibility to fail through SRC at temperatures relevant for CSP. Post weld heat treatment conditions and alternative alloys are investigated as potential mitigation solutions to SRC. We used Gleeble thermomechanical simulation tests and finite element (FE) models to understand the susceptibility of 347H SS to SRC as a function of temperature, stress, and microstructure. We started with a literature review of weldability issues with 347H SS and techniques to mitigate SRC in 347H SS weldments. Next, we used Gleeble experiments to determine reheat cracking susceptibility in the simulated HAZ of 347SS weldments and an alternative alloy, 316L SS (NUCL 167 SPH) with boron added. We also performed Gleeble experiments to compare the reheat cracking susceptibility of 347H cross welded with two different fillers: E347, which is used in some commercial CSP TES tanks, and E16.8.2. We validated the experimental results with FE models of the residual stresses. We found that although the 316L (NUCL 167 SPH) is less susceptible to reheat cracking, it is slightly weaker than 347H and ASME BP&V codes limit its use to a service condition of 565°C. We also found that welds using E16.8.2 as the weld filler are less susceptible to failure than those using E347, likely due to the higher creep ductility of E16.8.2, and that it may be used as an alternative filler for repair welding of 347H welds or as the primary choice of filler for newly developed weld joints. We also found that post weld heat treatment could be a viable solution for mitigating stress in E347-347H SS thick, constrained welds, like those found in CSP tanks, and propose several options for mitigating SRC in existing and future TES tanks.

14 SOLAR ENERGY↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 C and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3mm. Single-sided NDE methods were used because they might be practical for on-wing inspection, while X-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally cracked coating and subsequent oxidation damage was also studied with X-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

Microcracking in composite laminates under thermal and mechanical loading

Composites used in space structures are exposed to both extremes in temperature and applied mechanical loads. Cracks in the matrix form, changing the laminate thermoelastic properties. The goal of the present investigation is to develop a predictive methodology to quantify microcracking in general composite laminates under both thermal and mechanical loading. This objective is successfully met through a combination of analytical modeling and experimental investigation. In the analysis, the stress and displacement distributions in the vicinity of a crack are determined using a shear lag model. These are incorporated into an energy based cracking criterion to determine the favorability of crack formation. A progressive damage algorithm allows the inclusion of material softening effects and temperature-dependent material properties. The analysis is implemented by a computer code which gives predicted crack density and degraded laminate properties as functions of any thermomechanical load history. Extensive experimentation provides verification of the analysis. AS4/3501-6 graphite/epoxy laminates are manufactured with three different layups to investigate ply thickness and orientation effects. Thermal specimens are cooled to progressively lower temperatures down to -184 C. After conditioning the specimens to each temperature, cracks are counted on their edges using optical microscopy and in their interiors by sanding to incremental depths. Tensile coupons are loaded monotonically to progressively higher loads until failure. Cracks are counted on the coupon edges after each loading. A data fit to all available results provides input parameters for the analysis and shows them to be material properties, independent of geometry and loading. Correlation between experiment and analysis is generally very good under both thermal and mechanical loading, showing the methodology to be a powerful, unified tool. Delayed crack initiation observed in a few cases is attributed to a lack of preexisting flaws assumed by the analysis. Some interactions between adjacent ply groups are attributed to local stress concentrations. These two effects are not captured by the analysis due to its global nature. The analysis is conservative in these cases and agrees well with data after the observed onset of cracking.

Maddocks, Jason R.↗

Degradation of Teflon(tm) FEP Following Charged Particle Radiation and Rapid Thermal Cycling

During the Second Servicing Mission (SM2) of the Hubble Space Telescope (HST) severe degradation was observed on the outer layer of the thermal control blankets. Astronaut observations and photographs revealed large cracks in the metallized Teflon FEP (fluorinated ethylene propylene), the outer layer of the multi-layer insulation (MLI), in many locations around the telescope. In an effort to understand what elements of the space environment might cause such damage, pristine Teflon' FEP was tested for durability to radiation and thermal cycling. Specimens were subjected to electron and proton fluences comparable to those experienced by HST and were subsequently thermal cycled in a custom-built rapid thermal cycle chamber. Tensile tests of the specimens showed that radiation followed by thermal cycling significantly reduced the ultimate strength and elongation of Teflon FEP.

Townsend, Jacqueline A.↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon (RCC)

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3 mm. Single-sided NDE methods were used since they might be practical for on-wing inspection, while x-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally-cracked coating and subsequent oxidation damage was also studied with x-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

Thermal certification tests of Orbiter Thermal Protection System tiles coated with KSC coating slurries

Thermal tests of Orbiter thermal protection system (TPS) tiles, which were coated with borosilicate glass slurries fabricated at Kennedy Space Center (KSC), were performed in the Radiant Heat Test Facility and the Atmospheric Reentry Materials & Structures Evaluation Facility at Johnson Space Center to verify tile coating integrity after exposure to multiple entry simulation cycles in both radiant and convective heating environments. Eight high temperature reusable surface insulation (HRSI) tiles and six low temperature reusable surface insulation (LRSI) tiles were subjected to 25 cycles of radiant heat at peaked surface temperatures of 2300 F and 1200 F, respectively. For the LRSI tiles, an additional cycle at peaked surface temperature of 2100 F was performed. There was no coating crack on any of the HRSI specimens. However, there were eight small coating cracks (less than 2 inches long) on two of the six LRSI tiles on the 26th cycle. There was practically no change on the surface reflectivity, physical dimensions, or weight of any of the test specimens. There was no observable thermal-chemical degradation of the coating either. For the convective heat test, eight HRSI tiles were tested for five cycles at a surface temperature of 2300 F. There was no thermal-induced coating crack on any of the test specimens, almost no change on the surface reflectivity, and no observable thermal-chemical degradation with an exception of minor slumping of the coating under painted TPS identification numbers. The tests demonstrated that KSC's TPS slurries and coating processes meet the Orbiter's thermal specification requirements.

Milhoan, James D.↗

Degradation of Teflon(tm) FEP Following Charged Particle Radiation and Rapid Thermal Cycling

During the Second Servicing Mission (SM2) of the Hubble Space Telescope (HST) severe degradation was observed on the outer layer of the thermal control blankets. Astronaut observations and photographs revealed large cracks in the metallized Teflon' FEP (fluorinated ethylene propylene), the outer layer of the multi-layer insulation (MLI), in many locations around the telescope. In an effort to understand what elements of the space environment might cause such damage, pristine Teflon(registered trademark) FEP was tested for durability to radiation and thermal cycling. Specimens were subjected to electron and proton fluences comparable to those experienced by HST and were subsequently thermal cycled in a custom-built rapid thermal cycle chamber. Tensile tests of the specimens showed that radiation followed by thermal cycling significantly reduced the ultimate strength and elongation of Teflon(registered trademark) FEP.

Townsend, Jacqueline A.↗

Degradation of Teflon(tm) FEP Following Charged Particle Radiation and Rapid Thermal Cycling

During the Second Servicing Mission (SM2) of the Hubble Space Telescope (HST) severe degradation was observed on the outer layer of the thermal control blankets. Astronaut observations and photographs revealed large cracks in the metallized Teflon(R) FEP (fluorinated ethylene propylene), the outer layer of the multi-layer insulation (MLI), in many locations around the telescope. In an effort to understand what elements of the space environment might cause such damage, pristine Teflon(R) FEP was tested for durability to radiation and thermal cycling. Specimens were subjected to electron and proton fluences comparable to those experienced by HST and were subsequently thermal cycled in a custom-built rapid thermal cycle chamber. Tensile tests of the specimens showed that radiation followed by thermal cycling significantly reduced the ultimate strength and elongation of Teflon(R) FEP.

Townsend, Jacqueline↗

Degradation of Teflon(trademark) FEP Following Charged Particle Radiation and Rapid Thermal Cycling

During the Second Servicing Mission (SM2) of the Hubble Space Telescope (HST) severe degradation was observed on the outer layer of the thermal control blankets. Astronaut observations and photographs revealed large cracks in the metallized Teflon(trademark) FEP (fluorinated ethylene propylene), the outer layer of the multi-layer insulation (MLI), in many locations around the telescope. In an effort to understand what elements of the space environment might cause such damage, pristine Teflon(trademark) FEP was tested for durability to radiation and thermal cycling. Specimens were subjected to electron and proton fluences comparable to those experienced by HST and were subsequently thermal cycled in a custom-built rapid thermal cycle chamber. Tensile tests of the specimens showed that radiation followed by thermal cycling significantly reduced the ultimate strength and elongation of Teflon(trademark) FEP.

Townsend, Jacqueline↗

Thermophysical and Thermomechanical Properties of Thermal Barrier Coating Systems

Thermal barrier coatings have been developed for advanced gas turbine and diesel engine applications to improve engine reliability and fuel efficiency. However, the issue of coating durability under high temperature cyclic conditions is still of major concern. The coating failure is closely related to thermal stresses and oxidation in the coating systems. Coating shrinkage cracking resulting from ceramic sintering and creep at high temperatures can further accelerate the coating failure process. The purpose of this paper is to address critical issues such as ceramic sintering and creep, thermal fatigue and their relevance to coating life prediction. Novel test approaches have been established to obtain critical thermophysical and thermomechanical properties of the coating systems under near-realistic temperature and stress gradients encountered in advanced engine systems. Emphasis is placed on the dynamic changes of the coating thermal conductivity and elastic modulus, fatigue and creep interactions, and resulting failure mechanisms during the simulated engine tests. Detailed experimental and modeling results describing processes occurring in the thermal barrier coating systems provide a framework for developing strategies to manage ceramic coating architecture, microstructure and properties.

Zhu, Dongming↗