Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Time-Resolved Temperature Mapping System for the APS Deflecting Cavity

Time-resolved temperature mapping of a superconducting cavity can give valuable information on the limiting process of the cavity performance. A fast temperature mapping system has been developed at Argonne National Laboratory (ANL) for a superconducting deflecting cavity test. The time resolution of the temperature mapping could be up to 50 us. Not only the spatial distribution of surface heating but also the thermodynamics can be recorded, which helps to understand the limitation mechanism. This new temperature mapping system has helped us to understand the rf performance limitations during the cavity vertical tests. Based on the findings from the temperature mapping, proper cavity treatment has been applied and the cavity performances have been improved.

Nassiri, A.↗

Probing the Excited State of Methylcobalamin Using Polarized Time-Resolved X-ray Absorption Spectroscopy

We use picosecond time-resolved polarized X-ray absorption near-edge structure (XANES) measurements to probe the structure of the long-lived photoexcited state of methylcobalamin (MeCbl) and the cob(II)alamin photoproduct formed following photoexcitation of adenosylcobalamin (AdoCbl, coenzyme B12). For MeCbl, we used 520 nm excitation and a time delay of 100 ps to avoid the formation of cob(II)alamin. We find only small spectral changes in the equatorial and axial directions, which we interpret as arising from small (<~0.05 Å) changes in both the equatorial and axial distances. This confirms expectations based on prior UV–visible transient absorption measurements and theoretical simulations. We do not find evidence for the significant elongation of the Co–C bond reported by Subramanian [ J. Phys. Chem. Lett. 2018, 9, 1542–1546] following 400 nm excitation. For AdoCbl, we resolve the difference XANES contributions along three unique molecular axes by exciting with both 540 and 365 nm light, demonstrating that the spectral changes are predominantly polarized along the axial direction, consistent with the loss of axial ligation. These data suggest that the microsecond “recombination product” identified by Subramanian et al. is actually the cob(II)alamin photoproduct that is produced following bond homolysis of MeCbl with 400 nm excitation. Our results highlight the pronounced advantage of using polarization-selective transient X-ray absorption for isolating structural dynamics in systems undergoing atomic displacements that are strongly correlated to the exciting optical polarization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Observation of the ππ* to nπ* Transition in 2-Thiouracil via Time-Resolved NEXAFS Spectroscopy

The photophysics of nucleobases has been the subject of both theoretical and experimental studies over the past decades due to the challenges posed by resolving the steps of their radiationless relaxation dynamics, which cannot be described in the framework of the Born–Oppenheimer approximation (BOA). In this context, the ultrafast dynamics of 2-thiouracil has been investigated with a time-resolved NEXAFS study at the Free Electron Laser FLASH. Near Edge X-ray Absorption Fine Structure spectroscopy (NEXAFS) can be used to observe electronic transitions in ultrafast molecular relaxation. We performed time-resolved UV-pump/X-ray probe absorption measurements at the sulfur 2s (L1) and 2p (L2/3) edges. We are able to identify absorption features corresponding to the S2 (ππ*) and S1 (nπ*) electronic states. We observe a delay of 102 ± 11 fs in the population of the nπ* state with respect to the initial optical excitation and interpret the delay as the time scale for the S2 → S1 internal conversion. We furthermore identify oscillations in the absorption signal that match a similar observation in our previous X-ray photoelectron spectroscopy study on the same molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of Minerals, Organic and Biogenic Materials through Time-Resolved Raman Spectroscopy

A compact remote Raman spectroscopy system was developed at NASA Langley Research center and was previously demonstrated for its ability to identify chemical composition of various rocks and minerals. In this study, the Raman sensor was utilized to perform time-resolved Raman studies of various samples such as minerals and rocks, Azalea leaves and a few fossil samples. The Raman sensor utilizes a pulsed 532 nm Nd:YAG laser as excitation source, a 4-inch telescope to collect the Raman-scattered signal from a sample several meters away, a spectrograph equipped with a holographic grating, and a gated intensified CCD (ICCD) camera system. Time resolved Raman measurements were carried out by varying the gate delay with fixed short gate width of the ICCD camera, allowing measurement of both Raman signals and fluorescence signals. Rocks and mineral samples were characterized including marble, which contain CaCO3. Analysis of the results reveals the short (approx.10-13 s) lifetime of the Raman process, and shows that Raman spectra of some mineral samples contain fluorescence emission due to organic impurities. Also analyzed were a green (pristine) and a yellow (decayed) sample of Gardenia leaves. It was observed that the fluorescence signals from the green and yellow leaf samples showed stronger signals compared to the Raman lines. Moreover, it was also observed that the fluorescence of the green leaf was more intense and had a shorter lifetime than that of the yellow leaf. For the fossil samples, Raman shifted lines could not be observed due the presence of very strong short-lived fluorescence.

Garcia, Christopher S.↗

Density relaxation and particle motion characteristics in a non-ionic deep eutectic solvent (acetamide + urea): Time-resolved fluorescence measurements and all-atom molecular dynamics simulations

Temperature dependent relaxation dynamics, particle motion characteristics, and heterogeneity aspects of deep eutectic solvents (DESs) made of acetamide (CH{sub 3}CONH{sub 2}) and urea (NH{sub 2}CONH{sub 2}) have been investigated by employing time-resolved fluorescence measurements and all-atom molecular dynamics simulations. Three different compositions (f) for the mixture [fCH{sub 3}CONH{sub 2} + (1 − f)NH{sub 2}CONH{sub 2}] have been studied in a temperature range of 328-353 K which is ∼120-145 K above the measured glass transition temperatures (∼207 K) of these DESs but much lower than the individual melting temperature of either of the constituents. Steady state fluorescence emission measurements using probe solutes with sharply different lifetimes do not indicate any dependence on excitation wavelength in these metastable molten systems. Time-resolved fluorescence anisotropy measurements reveal near-hydrodynamic coupling between medium viscosity and rotation of a dissolved dipolar solute. Stokes shift dynamics have been found to be too fast to be detected by the time-resolution (∼70 ps) employed, suggesting extremely rapid medium polarization relaxation. All-atom simulations reveal Gaussian distribution for particle displacements and van Hove correlations, and significant overlap between non-Gaussian (α{sub 2}) and new non-Gaussian (γ) heterogeneity parameters. In addition, no stretched exponential relaxations have been detected in the simulated wavenumber dependent acetamide dynamic structure factors. All these results are in sharp contrast to earlier observations for ionic deep eutectics with acetamide [Guchhait et al., J. Chem. Phys. 140, 104514 (2014)] and suggest a fundamental difference in interaction and dynamics between ionic and non-ionic deep eutectic solvent systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Watching a signaling protein function: What has been learned over four decades of time-resolved studies of photoactive yellow protein

Photoactive yellow protein (PYP) is a signaling protein whose internal p-coumaric acid chromophore undergoes reversible, light-induced trans-to-cis isomerization, which triggers a sequence of structural changes that ultimately lead to a signaling state. Since its discovery nearly 40 years ago, PYP has attracted much interest and has become one of the most extensively studied proteins found in nature. The method of time-resolved crystallography, pioneered by Keith Moffat, has successfully characterized intermediates in the PYP photocycle at near atomic resolution over 12 decades of time down to the sub-picosecond time scale, allowing one to stitch together a movie and literally watch a protein as it functions. But how close to reality is this movie? To address this question, results from numerous complementary time-resolved techniques including x-ray crystallography, x-ray scattering, and spectroscopy are discussed. Emerging from spectroscopic studies is a general consensus that three time constants are required to model the excited state relaxation, with a highly strained ground-state cis intermediate formed in less than 2.4 ps. Persistent strain drives the sequence of structural transitions that ultimately produce the signaling state. Crystal packing forces produce a restoring force that slows somewhat the rates of interconversion between the intermediates. Moreover, the solvent composition surrounding PYP can influence the number and structures of intermediates as well as the rates at which they interconvert. When chloride is present, the PYP photocycle in a crystal closely tracks that in solution, which suggests the epic movie of the PYP photocycle is indeed based in reality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Photoluminescence of InGaAs Nanostructures Different in Quantum Dimensionality

The time-resolved photoluminescence of quantum-confined InGaAs heterostructures grown on GaAs substrates is studied by time-correlated single photon counting. The heterostructures have different dimensionalities: the structures are formed as quantum dots, quantum wells, and structures of transition dimensionality (quantum well-dots). It is found that the room-temperature photoluminescence decay time of the samples substantially depends on their dimensionality and corresponds to 6, 7, and >20 ns for quantum dots, well-dots, and wells, respectively. It is thought that the presence of localization centers for charge carriers can be responsible for the experimentally observed shortening of the photoluminescence time in the heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-photon resonances in femtosecond time-resolved four-wave mixing spectroscopy: {beta}-carotene

Femtosecond time-resolved pump-degenerate four-wave mixing (pump-DFWM) spectroscopy has been used to study the ultrafast dynamics of {beta}-carotene involving several electronic and vibrational states. An initial pump pulse, resonant with the S{sub 0}-to-S{sub 2} transition, excites the molecular system and a DFWM process, resonant with the S{sub 1}-to-S{sub n} transition, is used to probe the relaxation pathways. The transient shows a peculiar decay behavior, which is due to the contributions of resonant DFWM signal of the excited S{sub 1} state, nonresonant DFWM signal of the ground S{sub 0} state and vibrational hot S{sub 0}{sup *} state, and the two-photon resonant DFWM signal of the ground S{sub 0} state. We have used a kinetic model including all the signal contributions to successfully fit the transient. The time constants extracted are in very good agreement with the known values for {beta}-carotene. For comparison, a two-pulse pump-probe experiment was performed measuring the transient absorption at the wavelength of the DFWM experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Laue Diffraction of Deforming Micropillars

We demonstrate real-time resolved white beam Laue diffraction during compression of micron-sized focused ion beam milled single crystals Au pillars, revealing the dynamical correlation between microstructure and plasticity. The evolution of the Laue patterns of the Au pillars demonstrates the occurrence of crystal rotation and strengthening is explained by plasticity starting on a slip system that is geometrically not predicted but selected because of the character of the preexisting strain gradient.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-SITU, Time-resolved Raman Spectro-micro-topography of an Operating Lithium Ion Battery

A Raman microscope has been coupled to a computer-controlled, two-dimensional linear translator attached to a custom-designed, sealed optical chamber to allow in situ acquisition of space-, and time-resolved spectra of an operating thin graphite/LiCoO2 Li-ion battery. This unique arrangement made it possible to collect continuously series of Raman spectra from a sharply defined edge of the battery exposing the anode (A), separator (S), and cathode (C), during charge and discharge, while the device was moved back and forth under the fixed focused laser beam along an axis normal to the layered A/S/C plane. Clear spectral evidence was obtained for changes in the amount of Li(+) within particles of graphite in the anode, and, to a lesser extent, of LiCoO2 in the cathode, during battery discharge both as a function of position and time. Analysis of time-resolved Raman spectro-micro-topography (SMT) measurements of the type described in this work are expected to open new prospects for assessing the validity of theoretical models aimed at simulating the flow of Li(+) within Li-ion batteries under operating conditions.

Luo, Yu↗

WE-G-BRF-08: Robust Characterization and Patient Experience of a Time-Resolved Ultrasound System for Prostate Tracking

Purpose: Characterization of a time resolved ultrasound device (4D-US), used for localization and motion monitoring of prostate radiotherapy. Methods: The 4D-US system accuracy to reproduce prostate motion was investigated and artifacts were determined under detailed experimental and ultimately clinical conditions. Two fields of view (FOV) of 30 and 60 degrees and two corresponding acquisition speeds were evaluated under experimental conditions with gradual increased complexity. The reconstruction ability and trajectory tracking depends on the relative speed between the ultrasound probe and the moving object. Two different types of phantoms were developed; one capable of following a predetermined trajectory with variable speeds, and a second one designed to test the US ability to a track dynamically-deformed prostate. Four hypo-prostate patients (10fx) were monitored during the treatment to detect intrafraction motion. Results: Prostate speeds up to 6mm/s and 3mm/s can be successfully tracked by the system when using the small and large FOV, respectively. The system response time, calculated based on the speedinduced volumetric distortion, is dependent on the FOV, with 1.1s for the small FOV and 1.4s for the large FOV. The response time was also found dependent on the size of target, increasing from 1.4s to 1.7s for target diameters of 4cm to 2.8cm. The deformable dynamic phantom has shown that the system is able to successfully follow a highly-deformed, slowmoving prostate with an error < 0.5mm. The overall range of patient intrafraction motion was (−2.4 to 2.2)mm, (−2.6 to 2.4)mm, (−3.0 to 4.3)mm in the RL, SI and AP directions, respectively. Conclusion: The 4DUS system using a large FOV is appropriate to monitor the prostate motion as well as the adjacent organs at risk. However, infrequent abrupt motion can be problematic and the small FOV system is preferred for such patients, particularly for future applications as online prostate monitoring employed for MLC tracking.

60 APPLIED LIFE SCIENCES↗

Time-Resolved Line Shapes of Single Quantum Emitters via Machine Learned Photon Correlations

Solid-state single-photon emitters (SPEs) are quantum light sources that combine atomlike optical properties with solid-state integration and fabrication capabilities. SPEs are hindered by spectral diffusion, where the emitter’s surrounding environment induces random energy fluctuations. Timescales of spectral diffusion span nanoseconds to minutes and require probing single emitters to remove ensemble averaging. Photon correlation Fourier spectroscopy (PCFS) can be used to measure time-resolved single emitter line shapes, but is hindered by poor signal-to-noise ratio in the measured correlation functions at early times due to low photon counts. Here, we develop a framework to simulate PCFS correlation functions directly from diffusing spectra that match well with experimental data for single colloidal quantum dots. We use these simulated datasets to train a deep ensemble autoencoder machine learning model that outputs accurate, noiseless, and probabilistic reconstructions of the noisy correlations. Using this model, we obtain reconstructed time-resolved single dot emission line shapes at timescales as low as 10 ns, which are otherwise completely obscured by noise. This enables PCFS to extract optical coherence times on the same timescales as Hong-Ou-Mandel two-photon interference, but with the advantage of providing spectral information in addition to estimates of photon indistinguishability. Further, our machine learning approach is broadly applicable to different photon correlation spectroscopy techniques and SPE systems, offering an enhanced tool for probing single emitter line shapes on previously inaccessible timescales.

74 ATOMIC AND MOLECULAR PHYSICS↗

EMCCD-Based Detector for Time-Resolved X-Ray Diffraction and Scattering Studies of Biological Specimens

Third generation synchrotron sources such as the Advanced Photon Source (APS), Argonne, IL, are outstanding tools for X-ray diffraction and scattering studies of non-crystalline biological materials. However, these studies are hindered by the lack of detectors that provide multiple frames of detailed structural information on the millisecond time scale at the required high spatial resolution, and large active areas. Here we report the development of a cost effective detector for time-resolved small angle X-ray scattering (SAXS) using a cooled, fiberoptically coupled electron multiplying CCD (EMCCD), whose internal gain is selectable in real-time. The performance of the detector was evaluated using a Gd{sub 2}O{sub 2}S:Tb scintillator and was compared to a current state-of-the-art SAXS detector developed at Brandeis University. We also report our first results on the fabrication of a novel, microcolumnar, ZnSe(Te) scintillator that has a promise to provide very high emission efficiency of over 100,000 photons/MeV, high spatial resolution in excess of 10 lp/mm, and a fast decay time with virtually absent afterglow. Development of this scintillator will complement the EMCCD design, permitting the advances of a high spatial and temporal resolution, large area detector for time resolved applications.

43 PARTICLE ACCELERATORS↗

Time-resolved imaging of the laser forward transfer of liquids

Time-resolved imaging is carried out to study the dynamics of the laser-induced forward transfer of an aqueous solution at different laser fluences. The transfer mechanisms are elucidated, and directly correlated with the material deposited at the analyzed irradiation conditions. It is found that there exists a fluence range in which regular and well-defined droplets are deposited. In this case, laser pulse energy absorption results in the formation of a plasma, which expansion originates a cavitation bubble in the liquid. After the further expansion and collapse of the bubble, a long and uniform jet is developed, which advances at a constant velocity until it reaches the receptor substrate. On the other hand, for lower fluences no material is deposited. In this case, although a jet can be also generated, it recoils before reaching the substrate. For higher fluences, splashing is observed on the receptor substrate due to the bursting of the cavitation bubble. Finally, a discussion of the possible mechanisms which lead to such singular dynamics is also provided.

36 MATERIALS SCIENCE↗

Time-resolved investigations of the non-thermal ablation process of graphite induced by femtosecond laser pulses

We report on the in-situ analysis of the ablation dynamics of the, so-called, laser induced non-thermal ablation process of graphite. A highly oriented pyrolytic graphite is excited by femtosecond laser pulses with fluences below the classic thermal ablation threshold. The ablation dynamics are investigated by axial pump-probe reflection measurements, transversal pump-probe shadowgraphy, and time-resolved transversal emission photography. The combination of the applied analysis methods allows for a continuous and detailed time-resolved observation of the non-thermal ablation dynamics from several picoseconds up to 180 ns. Formation of large, μm-sized particles takes place within the first 3.5 ns after irradiation. The following propagation of ablation products and the shock wave front are tracked by transversal shadowgraphy up to 16 ns. The comparison of ablation dynamics of different fluences by emission photography reveals thermal ablation products even for non-thermal fluences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved vacuum-ultraviolet photoelectron spectroscopy of the à 1 A u state of acetylene

Ultrafast time-resolved photoelectron spectra are reported for the vacuum-ultraviolet (VUV) photoionization of acetylene following excitation to the à 1 A u state via UV absorption at 200 nm. The excitation energy lies above the lowest dissociation threshold to C 2 H X̃ 2 Σ + + H, as well as above the threshold for adiabatic dissociation of the à 1 A u state to form C 2 H (à 2 Π) + H. The time-dependent mass spectra and photoelectron spectra provide insight into the intramolecular decay processes of the à 1 A u state. In addition, photoelectron spectra of the à 1 A u state with VUV light access both the X̃ 2 Π u and à 2 Σ g + states of the ion, as well as the predicted, but previously unobserved, 1 2 Π g state, which corresponds to a two-hole, one-particle configuration that lies in close proximity to the à 2 Σ g + state. The 1 2 Π g state is split into 2 A 2 + 2 B 2 and 2 A g + 2 B g states in the cis and trans configurations, respectively. In conclusion, electronic structure calculations, along with trajectory calculations, reproduce the principal features of the experimental data and confirm the assignment of the 1 2 Π g state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗