Architecture for time or transform domain decoding of reed-solomon codes

Two pipeline (255,233) RS decoders, one a time domain decoder and the other a transform domain decoder, use the same first part to develop an errata locator polynomial .tau.(x), and an errata evaluator polynominal A(x). Both the time domain decoder and transform domain decoder have a modified GCD that uses an input multiplexer and an output demultiplexer to reduce the number of GCD cells required. The time domain decoder uses a Chien search and polynomial evaluator on the GCD outputs .tau.(x) and A(x), for the final decoding steps, while the transform domain decoder uses a transform error pattern algorithm operating on .tau.(x) and the initial syndrome computation S(x), followed by an inverse transform algorithm in sequence for the final decoding steps prior to adding the received RS coded message to produce a decoded output message.

Shao, Howard M.↗

Reliable Real-Time Solution of Parametrized Partial Differential Equations: Reduced-Basis Output Bound Methods

We present a technique for the rapid and reliable prediction of linear-functional outputs of elliptic (and parabolic) partial differential equations with affine parameter dependence. The essential components are (i) (provably) rapidly convergent global reduced basis approximations, Galerkin projection onto a space W(sub N) spanned by solutions of the governing partial differential equation at N selected points in parameter space; (ii) a posteriori error estimation, relaxations of the error-residual equation that provide inexpensive yet sharp and rigorous bounds for the error in the outputs of interest; and (iii) off-line/on-line computational procedures, methods which decouple the generation and projection stages of the approximation process. The operation count for the on-line stage, in which, given a new parameter value, we calculate the output of interest and associated error bound, depends only on N (typically very small) and the parametric complexity of the problem; the method is thus ideally suited for the repeated and rapid evaluations required in the context of parameter estimation, design, optimization, and real-time control.

Prudhomme, C.↗

Strapdown system performance optimization test evaluations (SPOT), volume 1

A three axis inertial system was packaged in an Apollo gimbal fixture for fine grain evaluation of strapdown system performance in dynamic environments. These evaluations have provided information to assess the effectiveness of real-time compensation techniques and to study system performance tradeoffs to factors such as quantization and iteration rate. The strapdown performance and tradeoff studies conducted include: (1) Compensation models and techniques for the inertial instrument first-order error terms were developed and compensation effectivity was demonstrated in four basic environments; single and multi-axis slew, and single and multi-axis oscillatory. (2) The theoretical coning bandwidth for the first-order quaternion algorithm expansion was verified. (3) Gyro loop quantization was identified to affect proportionally the system attitude uncertainty. (4) Land navigation evaluations identified the requirement for accurate initialization alignment in order to pursue fine grain navigation evaluations.

Blaha, R. J.↗

Optimization of tomographic reconstruction workflows on geographically distributed resources

New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new data processing technique for Rayleigh-Taylor instability growth experiments

Typical face-on experiments for Rayleigh-Taylor instability study involve the time-resolved radiography of an accelerated foil with line-of-sight of the radiography along the direction of motion. The usual method which derives perturbation amplitudes from the face-on images reverses the actual image transmission procedure, so the obtained results will have a large error in the case of large optical depth. In order to improve the accuracy of data processing, a new data processing technique has been developed to process the face-on images. This technique based on convolution theorem, refined solutions of optical depth can be achieved by solving equations. Furthermore, we discuss both techniques for image processing, including the influence of modulation transfer function of imaging system and the backlighter spatial profile. Besides, we use the two methods to the process the experimental results in Shenguang-II laser facility and the comparison shows that the new method effectively improve the accuracy of data processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higher order treatment on temporal derivative of angular flux for time-dependent MOC

A new kinetic analysis method, whose angular dependence of temporal derivative for angular flux is accurately treated within practical memory requirement, is proposed. The method of characteristics (MOC) is being widely used for reactor analysis thanks to the advances of numerical algorithms and computer hardware. However, the computational resources, i.e., the memory capacity, can be still a crucial problem for rigorous kinetic calculations using MOC. In the straightforward approach for kinetic calculation using MOC, the segment-averaged angular fluxes should be stored on the memory in order to explicitly calculate the temporal derivative of the angular flux, which would require huge memory. Thus, in the conventional kinetic calculation code using MOC, the temporal derivative of the angular flux has been approximated as angularly isotropic in order to reduce the memory requirement (isotropic assumption). However, the approximation error caused by the conventional isotropic assumption has not been thoroughly and quantitatively investigated so far and an accurate kinetic calculation method, which can quantitatively estimate the above approximation error within practical memory storage, has not been developed. The present study tries to address this issue with a newly developed approach. Effect of the approximate treatment for the temporal derivative of angular flux is evaluated through benchmark calculations. (authors)

97 MATHEMATICS AND COMPUTING↗

Improving compliance with Intersocietal Accreditation Commission (IAC) reporting standards: A serial comparison of 523 labs over seven years

Background: The aim of this study was to evaluate reporting compliance of laboratories applying for serial accreditation by the Intersocietal Accreditation Commission (IAC) and compare compliance based on laboratory characteristics. Methods: All laboratories applying for IAC accreditation for the first time in 2008 and then twice more (2011-2014) were evaluated for compliance with 18 reporting elements. The elements were ranked into three severity groups (high/moderate/low). Results: Reports from 523 laboratories were evaluated. The percentage of laboratories with reporting issues by cycle was 66.2% for cycle 1, 36.7% for cycle 2, and 43.8% for cycle 3 (p < .001). For most of the 18 elements, there was a significant decrease in the percentage of labs with issues. Less moderate and high severity errors were seen over time. Also, the mean non-compliant elements per laboratory decreased from 5.78 ± 2.72 at cycle 1, down to 1.25 ± 1.77 at cycle 3. Conclusions: In facilities applying for 3 consecutive IAC accreditation cycles, reporting compliance with IAC Standards improved between cycles 1-2 and 1-3. No significant improvement occurred between cycles 2-3. Although the quality of reports improved overall, problems remain in quantifying myocardial perfusion defects, documenting report approval date, and integrating stress and imaging reports.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-01: A Data-Driven 4D-MRI Motion Model to Estimate Full Field-Of-View Abdominal Motion From 2D Image Navigators During MR-Linac Treatment

Purpose: To estimate full field-of-view abdominal respiratory motion from fast 2D image navigators using a 4D-MRI based motion model. This will allow for radiation dose accumulation mapping during MR-Linac treatment. Methods: Experiments were conducted on a Philips Ingenia 1.5T MRI. First, a retrospectively ordered 4D-MRI was constructed using 3D transient-bSSFP with radial in-plane sampling. Motion fields were calculated through 3D non-rigid registration. From these motion fields a PCA-based abdominal motion model was constructed and used to warp a 3D reference volume to fast 2D cine-MR image navigators that can be used for real-time tracking. To test this procedure, a time-series consisting of two interleaved orthogonal slices (sagittal and coronal), positioned on the pancreas or kidneys, were acquired for 1m38s (dynamic scan-time=0.196ms), during normal, shallow, or deep breathing. The coronal slices were used to update the optimal weights for the first two PCA components, in order to warp the 3D reference image and construct a dynamic 4D-MRI time-series. The interleaved sagittal slices served as an independent measure to test the model’s accuracy and fit. Spatial maps of the root-mean-squared error (RMSE) and histograms of the motion differences within the pancreas and kidneys were used to evaluate the method. Results: Cranio-caudal motion was accurately calculated within the pancreas using the model for normal and shallow breathing with an RMSE of 1.6mm and 1.5mm and a histogram median and standard deviation below 0.2 and 1.7mm, respectively. For deep-breathing an underestimation of the inhale amplitude was observed (RMSE=4.1mm). Respiratory-induced antero-posterior and lateral motion were correctly mapped (RMSE=0.6/0.5mm). Kidney motion demonstrated good motion estimation with RMSE-values of 0.95 and 2.4mm for the right and left kidney, respectively. Conclusion: We have demonstrated a method that can calculate dynamic 3D abdominal motion in a large volume, while acquiring real-time cine-MR images for MR-guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

An embedded mesh method using piecewise constant multipliers with stabilization: mathematical and numerical aspects

An embedded mesh method using piecewise constant multipliers originally proposed by Puso et al. (CMAME, 2012) is analyzed here to determine effects of the pressure stabilization term and small cut cells. The approach is implemented for transient dynamics using the central difference scheme for the time discretization. It is shown that the resulting equations of motion are a stable linear system with a condition number independent of mesh size. Furthermore, we show that the constraints and the stabilization terms can be recast as non-proportional damping such that the time integration of the scheme is provably stable with a critical time step computed from the undamped equations of motion. Effects of small cuts are discussed throughout the presentation. A mesh study is conducted to evaluate the effects of the stabilization on the discretization error and conditioning and is used to recommend an optimal value for stabilization scaling parameter. Several nonlinear problems are also analyzed and compared with comparable conforming mesh results. Finally, we show several demanding problems highlighting the robustness of the proposed approach.

42 ENGINEERING↗

Revenue prediction for integrated renewable energy and energy storage system using machine learning techniques

Revenue estimation for integrated renewable energy and energy storage systems is important to support plant owners or operators’ decisions in battery sizing selection that leads to maximized financial performances. A common approach to optimizing revenues of a hybrid hydro and energy storage system is using mixed-integer linear programming (MILP). Although MILP models can provide accurate production cost estimations, they are typically very computationally expensive. To provide a fast yet accurate first-step information to hydropower plant owners or operators who consider integrating energy storage systems, we propose an innovative approach to predicting optimal revenues of an integrated energy generation and storage system. In this study, we examined the performance of two prediction techniques: Generalized Additive Models (GAMs) and machine learning (ML) models developed based on artificial neural networks (ANN). Predictive equations and models are generated based on optimized solutions from a market participation optimization model, the Conventional Hydropower Energy and Environmental Resource System (CHEERS) model. The two predicting techniques reduce the computational time to evaluate annual revenue for one set of battery configurations from 3 h to 1 to 4 min per run while also being implementable with significantly less data. The model validation prediction errors of developed GAMs and ML models are generally below 5%; for model testing predictions, the ML models consistently outperform the regression equations in terms of root mean square errors. This new approach allows plant owners, operators, or potential investors to quickly access multiple battery configurations under different energy generation and market scenarios. This new revenue prediction method will therefore help reduce the barriers, and thereby promoting the deployment of battery hybridization with existing renewable energy sources.

13 HYDRO ENERGY↗

A Secure and Adaptive Hierarchical Multi-Timescale Framework for Resilient Load Restoration Using a Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMGs are challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. Here, this paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using new obtained forecasts, followed by the RT dispatch stage. To make the decisions more secure and robust against forecast errors, a novel concept called delayed recourse is designed. The approach is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS and hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure distribution network operation under different operating scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gamma-ray burster recurrence time scales

In the decade since gamma-ray bursters (GRBs) were discovered by Klebesadel et al. (1973), many models have been proposed to explain the GRB phenomenon. A difficulty is related to the small number of predictions which would make it possible to evaluate the models. One verifiable prediction is the recurrence time scale, tau-gamma. One method to measure tau-gamma is to look for possible cases of recurrence as indicated by overlapping error boxes. The analysis considered in the present investigation is composed of three procedures. One of these involves a search through known error regions for cases where the error regions overlap. In addition, the number of overlaps expected by chance coincidence alone has been determined, and a calculation has been performed regarding the number of overlaps which are expected due to recurrence for various assumed tau-gamma and luminosity functions.

Schaefer, B. E.↗

Inverse solution of Kepler's equation for hyperbolic orbits

An algorithm is presented for efficient inverse solution of Kepler's equation for hyperbolic orbits. It is shown that an expansion of Barker's equation into a bicubic polynomial provides a good approximation to obtain accurate starting values for rapid numerical solution of Kepler's equation. In the approximate equation a cubic in normalized elapsed flight time from pericenter is set equal to a cubic in a function S of eccentricity and true anomaly. The initial estimate of S to use in an iteration formula is obtained by evaluating the cubic in normalized flight time and finding in most cases the single real root of the other cubic. This initial estimate has an accuracy corresponding to values of true anomaly in error by less than 0.5 degrees generally.

Boltz, Frederick W.↗

On estimating total daily evapotranspiration from remote surface temperature measurements

A method for calculating daily evapotranspiration from the daily surface energy budget using remotely sensed surface temperature and several meteorological variables is presented. Vaules of the coefficients are determined from simulations with a one-dimensional boundary layer model with vegetation cover. Model constants are obtained for vegetation and bare soil at two air temperature and wind speed levels over a range of surface roughness and wind speeds. A different means of estimating the daily evapotranspiration based on the time rate of increase of surface temperature during the morning is also considered. Both the equations using our model-derived constants and field measurements are evaluated, and a discussion of sources of error in the use of the formulation is given.

Carlson, Toby N.↗

International Conference on Mesoscale Precipitation: Hydrologic and Meteorological Aspects, 3rd, College Station, TX, Feb. 27-Mar. 1, 1991, Proceedings

Papers presented in this volume discuss a mechanism causing mesoscale organizations of precipitation in midlatitude cyclones, the spatial variability of summer Florida precipitation and its impact on microwave radiometer rainfall-measurement systems, the relation between the mean areal rainfall and the fractional area where it rains above a given threshold, and a possible explanation for low correlation dimension estimates for the atmosphere. Attention is also given to a physically based simulation of radar rainfall data using a space-time rainfall model, the predictability of mesoscale rainfall in the tropics, and an intercomparison of tree satellite infrared rainfall techniques over Japan and surrounding waters. Other papers are on an evaluation of sampling errors of precipitation from spaceborne and ground sensors, an approach to the estimation of the areal rain-rate distribution from spaceborne radar by the use of multiple thresholds, and a comparison of two satellite-based rainfall algorithms using Pacific atoll raingage data.

Valdes, Juan B.↗

Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements

Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification in the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.

60 APPLIED LIFE SCIENCES↗

A comparative study of measurements from radiosondes, rocketsondes, and satellites

Direct comparisons of operational products derived from measurements of radiance by satellites to measurements from conventional in situ sensors are important for the evaluation of satellite systems. However, errors in the in situ measurements themselves complicate such comparisons. Atmospheric temporal and spatial variability are also influential. These issues are investigated by means of a special field program composed of flights of dual radiosondes and multiple radiosondes launched near the time of NOAA-6 overpasses. Satellite derived mean layer temperatures, geopotential heights, and winds are compared with the same quantities determined from the in situ sensors. Of particular interest is the impact of in situ errors on these comparisons. It is shown that the radiosonde provides a precise pressure height relationship and therefore precise data for synoptic type use. Radar tracking of the radiosondes reveals, however, an imprecise pressure measurement which causes large differences between the actual altitude of the radiosonde and the altitude at which it is calculated to be. Radiosondes should be radar tracked and pressures calculated if the data are to be used for purposes other than synoptic use. Evaluation of rocketsonde data reveals a temperature precision of 1 to 2 K below about 55 km. Above 55 km, the precision decreases rapidly; rms differences of up to 11 K are obtained.

Nestler, M. S.↗

Preliminary Study on Two Possible Bunch Compression Schemes at NLCTA

In this paper, two possible bunch compression configurations are proposed and evaluated by numerical simulation in the Next Linear Collider Test Accelerator (NLCTA) at SLAC. A bunch compression ratio up to 20 could be achieved under a perfect condition, without consideration for the timing jitter and other error sources. The NLCTA is a test accelerator built at SLAC, which is approximately 42 meters long and composed of X-band acceleration structures. The main aim of building NLCTA is to develop and demonstrate the X-band rf acceleration technologies for the next generation linear collider, with a relatively high acceleration gradient between 50 MV/m and 100 MV/m. The current operation configuration of NLCTA features a thermionic-cathode electron gun at its starting point which generates an electron beam with an energy of 5 MeV. This is followed by a roughly 1.5 meter long X-band acceleration structure which boosts the electron beam energy to 60 MeV. Then there is a four-dipole magnetic chicane which is 6 meters long and provides a first order longitudinal dispersion of R{sub 56} = -73mm. Next the electron beam passes by several matching quadrupoles and can be accelerated further to 120 MeV through another one-meter-long X-band acceleration structure. After that, there are three small chicanes downstream, with a total first order longitudinal dispersion of R{sub 56} = -10mm. A sketch of the main components of NLCTA is shown in Figure 1, where the total length of this accelerator is 45 meters. Free Electron Lasers (FELs), proposed by J. Madey and demonstrated for the first time at Stanford University in 1970s [2] [3], use the lasing of relativistic electron beam traveling through a magnetic undulator, which can reach high power and can be widely tunable in wavelength. Linac based FEL source can provide sufficient brightness, and a short X-ray wavelength down to angstrom scale, which promises in supporting wide range of research experiments. In order to have an electron beam lasing coherently in an undulator, one needs a very bright beam in all three dimensions. In other words, one needs an electron beam with very short bunch length (high intensity), very small transverse emittance and very small energy spread. Most FELs currently being operated, commissioned, constructed or proposed are based on RF acceleration in a frequency range from L-band ( 1 GHz) to C-band ( 6 GHz). As RF frequency goes higher, wake fields effects tend to be much stronger and jitter tolerances are tighter. To demonstrate that X-band acceleration structures can be applied in constructing an FEL, one could perform bunch compression experiments at NLCTA as a first step, and investigate tolerances on timing jitter, misalignments etc.. Another important point is to evaluate the transverse emittance growth in this bunch compression process. In the following sections, two possible bunch compression schemes are proposed to be tested at NLCTA. Elegant [4] 3-D simulation is performed to evaluate these two schemes, with wake fields, space charge and coherent synchrotron radiation (CSR) effects included. One million macro particles are adopted in the numerical simulations. The simulation starts with an electron beam of 20 pC at a beam energy of 5 MeV. The initial RMS bunch length is taken as 0.5 ps at such a low bunch charge, and the RMS energy spread is 5 x 10{sup -3}. The normalized transverse emittance is 1 mm.mrad.

43 PARTICLE ACCELERATORS↗