Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilation controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

Construction of a 2- by 2-foot transonic adaptive-wall test section at the NASA Ames Research Center

The development of a new production-size, two-dimensional, adaptive-wall test section with ventilated walls at the NASA Ames Research Center is described. The new facility incorporates rapid closed-loop operation, computer/sensor integration, and on-line interference assessment and wall corrections. Air flow through the test section is controlled by a series of plenum compartments and three-way slide vales. A fast-scan laser velocimeter was built to measure velocity boundary conditions for the interference assessment scheme. A 15.2-cm- (6.0-in.-) chord NACA 0012 airfoil model will be used in the first experiments during calibration of the facility.

Morgan, Daniel G.↗

System for controlling child safety seat environment

A system is provided to control the environment experienced by a child in a child safety seat. Each of a plurality of thermoelectric elements is individually controllable to be one of heated and cooled relative to an ambient temperature. A first portion of the thermoelectric elements are positioned on the child safety seat such that a child sitting therein is positioned thereover. A ventilator coupled to the child safety seat moves air past a second portion of the thermoelectric elements and filters the air moved therepast. One or more jets coupled to the ventilator receive the filtered air. Each jet is coupled to the child safety seat and can be positioned to direct the heated/cooled filtered air to the vicinity of the head of the child sitting in the child safety seat.

Dabney, Richard W.↗

Proposed Protocols for Defining Requirements and Sizing of Media-Based Filters for Spacecraft and Planetary Lander Applications

The air quality control equipment aboard future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation in low gravity, and can experience short duration peak loading of dust from planetary surfaces for Lunar or Mars landers. The filter industry has established methods to properly size filters for a given particulate load, but requirements for the space or planetary application introduce additional consideration. In this work, a methodology for properly evaluating and sizing particulate filters for a Lunar surface pressurized environment will be presented, including estimating the loading and particle size distributions of the loading based on mission requirements. In addition, a scaling analysis from single filter media sheet to full-scale filters for this application, based on recent testing, will also be presented. These results of this study may provide meaningful guidance for properly designing media-based particulate filters for the air revitalization challenges in future deep space exploration missions.

media-based filters↗

Control of the Diurnal Pattern of Methane Emission from Emergent Aquatic Macrophytes by Gas Transport Mechanisms

Methane emissions from Typha latifolia (L.) showed a large mid-morning transient peak associated with rising light levels. This peak was also associated with a steep decline in lacunal CH, concentrations near the stem base. This pattern contrasted sharply with emissions from Peltandra virginica (L.) that gradually rose to a peak in the mid-afternoon corresponding to elevated air temperatures. Internal CH4 concentrations within P. virginica stems did not change significantly over the diurnal period. Stomatal conductance appeared to correlate directly with light levels in both plant types and were not associated with peak CH4 emission events in either plant. These patterns are consistent with a convective throughflow and diffusive gas ventilation systems for Typha and Peltandra, respectively. Further effects of the convective throughflow in T. latifolia were evident in the elevated CH4 concentrations measured within brown leaves as contrasted to the near ambient levels measured within live green leaves. Experimental manipulation of elevated and reduced CO2 levels in the atmosphere surrounding the plants and of light/dark periods suggested that stomatal aperture has little or no control of methane emissions from T. latifolia.

Whiting, Gary J.↗

Advanced support systems development and supporting technologies for Controlled Ecological Life Support Systems (CELSS)

A methyl acetate reactor was developed to perform a subscale kinetic investigation in the design and optimization of a full-scale metabolic simulator for long term testing of life support systems. Other tasks in support of the closed ecological life support system test program included: (1) heating, ventilation and air conditioning analysis of a variable pressure growth chamber, (2) experimental design for statistical analysis of plant crops, (3) resource recovery for closed life support systems, and (4) development of data acquisition software for automating an environmental growth chamber.

Simon, William E.↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Insect Habitat System for Studying Long Duration Circadian Rhythm Changes on Mir Space Station

A habitat for housing up to 32 black body beetles (Trigonoscelis gigas) has been developed at Ames Research Center for conducting studies to evaluate the effects of long duration spaceflight upon insect circadian timing systems. This habitat, identified as the Beetle Kit Assembly, provides an automatically controlled lighting system and activity and temperature recording devices, as well as individual beetle enclosures. Each of the 32 enclosures allows for ad lib movement of the beetle, as well as providing a simple food source and allowing ventilation of the beetle volume via an externally operated hand pump. The Beetle Kit Assemblies will be launched on STS-84 (Shuttle-Mir Mission-06) in May, 1997 and will be transferred to the Priroda module of the Russian Mir space station. he beetles will remain on Mir for approximately 125 days, and will be returned to earth on STS-86 in September, 1997.

Savage, P. D.↗

Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

Paul, Heather L.↗

Heat Exchanger/Humidifier Trade Study and Conceptual Design for the Constellation Space Suit Portable Life Support System Ventilation Subsystem

As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.

Paul, Heather L.↗

Model Validation for Bigelow Expandable Activity Module (BEAM) with Stowage

The Bigelow Expandable Activity Module (BEAM) was a collaboration between NASA and Bigelow Aerospace to develop an expandable habitat technology that could be used for future space exploration missions such as the Artemis program. On April 26, 2016, the BEAM was launched and berthed to the International Space Station (ISS) on the aft port of Node 3. After the originally planned two-year mission life, BEAM was approved for use as a stowage module for a 109-cargotransfer bag equivalent (CTBE) to alleviate stowage limitations onboard the ISS. The present work builds on the previous 2017 model validation to flight data that demonstrated that BEAM could generally accommodate cargo stowage without adversely affecting BEAM thermal control, primarily for condensation management. Once the stowage was configured in early 2019, model validation efforts resumed. The thermal model revisions included the CTBE stowage and updated CFD-derived heat transfer coefficients for various intra-module ventilation (IMV) flow rates. The coefficients were provided by the Crew and Thermal Systems Division (EC) at NASA JSC and Jacobs Technology. The model is now revalidated and able to predict minimum temperatures with good agreement to flight temperatures (within 1 °C) for both historic and recurring minimum values. Additionally, the model is partially validated for reduced flow rates. With this model, the team was able to provide new flight rule recommendations for condensation and IMV operations management.

Sydney Taylor↗

Rapid Cycle Amine 4.0 System Development

Carbon dioxide (CO2) and humidity control is a key function of the spacesuit Portable Life Support Subsystem (PLSS). The latest spacesuit design utilizes a pressure swing bed containing a solid amine sorbent to scrub CO2 and humidity produced by the crewmember from the ventilation loop. The solid amine sorbent removes CO2 and humidity from the ventilation loop through a chemisorption mechanism. Simultaneously, CO2 and humidity are desorbed to vacuum via the two-bed pressure swing system during operation. This continuous regeneration allows for longer Extravehicular Activity (EVA) times while minimizing maintenance, consumables, and power usage. This concept has been in development for over 20 years, during which many prototypes and design iterations have been fabricated and evaluated. This paper discusses the recent Rapid Cycle Amine (RCA) design, development, and testing that has been done to advance the technology. The most recent fabrication is the RCA 3.0. It was delivered to NASA Johnson Space Center in 2015 and has since been tested at the component level and at the integrated PLSS level. The purpose of the component level testing was to understand CO2 removal capacity, end-of-life performance, and establish a baseline performance prior to integrated testing. The RCA 3.0 was integrated into the Exploration Extravehicular Mobility Unit (xEMU) PLSS for a comprehensive Design Verification Test (DVT) series. The integrated testing provided the benefit of characterizing the impact performance degradation has on the system. Many of the RCA requirements were developed through analysis, based on the limitations of the PLSS and, in some cases, assumptions about the system and flow behavior. Integrated testing was an opportunity to validate those requirements and assumptions. While the RCA 3.0 was being tested, the next design iteration, RCA 4.0, was under development. The RCA 4.0 preliminary design phase began in late-2019 and shortly after the Preliminary Design Review, the critical design phase began in 2021. The design work has concluded with the completion of a Pre-Manufacturing Review in 2022. This paper provides an overview of the RCA 4.0 system design, summarizes the results of integrated RCA 3.0 testing, and discusses the pertinence of driving requirements such as mass, volume, and power consumption.

Kelsey Bloom↗

Experimental system for the control of surgically induced infections

The development tests to be performed on the experimental system are described in detail. The test equipment, conditions, and procedures are given. The portable clean room tests include assembly, collapsability, portability, and storage; laminar flow rate; static pressure; air flow pattern; and electrostatic buildup. The other tests are on the ventilation system, human factors evaluation, electrical subsystem, and material compatibility.

Tevebaugh, M. D.↗

Reformulation of Possio's kernel with application to unsteady wind tunnel interference

An efficient method for computing the Possio kernel has remained elusive up to the present time. In this paper the Possio is reformulated so that it can be computed accurately using existing high precision numerical quadrature techniques. Convergence to the correct values is demonstrated and optimization of the integration procedures is discussed. Since more general kernels such as those associated with unsteady flows in ventilated wind tunnels are analytic perturbations of the Possio free air kernel, a more accurate evaluation of their collocation matrices results with an exponential improvement in convergence. An application to predicting frequency response of an airfoil-trailing edge control system in a wind tunnel compared with that in free air is given showing strong interference effects.

Fromme, J. A.↗

A two-dimensional adaptive-wall test section with ventilated walls in the Ames 2- by 2-foot transonic wind tunnel

The first tests conducted in the adaptive-wall test section of the Ames Research Center's 2- by 2-Foot Transonic Wind Tunnel are described. A procedure was demonstrated for reducing wall interference in transonic flow past a two-dimensional airfoil by actively controlling flow through the slotted walls of the test section. Flow through the walls was controlled by adjusting pressures in compartments of plenums above and below the test section. Wall interference was assessed by measuring (with a laser velocimeter) velocity distributions along a contour surrounding the model, and then checking those measurements for their compatibility with free-air far-field boundary conditions. Plenum pressures for minimum wall interference were determined from empirical influence coefficients. An NACA 0012 airfoil was tested at angles of attach of 0 and 2, and at Mach numbers between 0.70 and 0.85. In all cases the wall-setting procedure greatly reduced wall interference. Wall interference, however, was never completely eliminated, primarily because the effect of plenum pressure changes on the velocities along the contour could not be accurately predicted.

Schairer, Edward T.↗

Cardiorespiratory deconditioning with static and dynamic leg exercise during bed rest

Results are presented for an experimental study designed to compare the effects of heavy static and dynamic exercise training during 14 days of bed rest on the cardiorespiratory responses to submaximal and maximal exercise performed by seven healthy men aged 19-22 yr. The parameters measured were submaximal and maximal oxygen uptake, minute ventilation, heart rate, and plasma volume. The results indicate that exercise alone during bed rest reduces but does not eliminate the reduction in maximal oxygen uptake. An additional positive hydrostatic effect is therefore necessary to restore maximal oxygen uptake to ambulatory control levels. The greater protective effect of static exercise on maximal oxygen uptake is probably due to a greater hydrostatic component from the isometric muscular contraction. Neither the static nor the dynamic exercise training regimes are found to minimize the changes in all the variables studied, thereby suggesting a combination of static and dynamic exercises.

Stremel, R. W.↗

An experimental study of an adaptive-wall wind tunnel

A series of adaptive wall ventilated wind tunnel experiments was carried out to demonstrate the feasibility of using the side wall pressure distribution as the flow variable for the assessment of compatibility with free air conditions. Iterative and one step convergence methods were applied using the streamwise velocity component, the side wall pressure distribution and the normal velocity component in order to investigate their relative merits. The advantage of using the side wall pressure as the flow variable is to reduce the data taking time which is one the major contributors to the total testing time. In ventilated adaptive wall wind tunnel testing, side wall pressure measurements require simple instrumentation as opposed to the Laser Doppler Velocimetry used to measure the velocity components. In ventilated adaptive wall tunnel testing, influence coefficients are required to determine the pressure corrections in the plenum compartment. Experiments were carried out to evaluate the influence coefficients from side wall pressure distributions, and from streamwise and normal velocity distributions at two control levels. Velocity measurements were made using a two component Laser Doppler Velocimeter system.

Celik, Zeki↗

Control of abdominal and expiratory intercostal muscle activity during vomiting - Role of ventral respiratory group expiratory neurons

The role of ventral respiratory group (VRG) expiratory (E) neurons in the control of abdominal and internal intercostal muscle activity during vomiting was investigated in cats. Two series of experiments were performed: in one, the activity of VRG E neurons was recorded during fictive vomiting in cats that were decerebrated, paralyzed, and artificially ventilated; in the second, the abdominal muscle activity during vomiting was compared before and after sectioning the axons of descending VRG E neurons in decerebrate spontaneously breathing cats. The results show that about two-thirds of VRG E neurons that project at least as far caudally as the lower thoracic cord contribute to internal intercostal muscle activity during vomiting. The remaining VRG E neurons contribute to abdominal muscle activation. As shown by severing the axons of the VRG E neurons, other, as yet unidenified, inputs (either descending from the brain stem or arising from spinal reflexes) can also produce abdominal muscle activation.

Miller, Alan D.↗