Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual recommendation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Where is the Human in the Loop? Human Factors Analysis of Extended Visual Line of Sight Unmanned Aerial System Operations within a Remote Operations Environment

Many envisioned technological and conceptual innovations focus on allocating more functions to automation, relegating the human as an afterthought if not a nuisance. Yet, until complete autonomy is realized, the human will remain “in the loop”. The National Aeronautics and Space Administration is supporting research for the development and maturation of automated technologies and architectures for the future of advanced air mobility. Standing up a remote operations center used to control, manage, and monitor multiple highly automated vehicles is an important step towards realizing the advanced air mobility vision. At the National Aeronautics and Space Administration’s Langley Research Center, a remote operation center exists and has been tested using humans piloting simulated vehicles. In this paper, we explore the human element within live flight operations that rely on increasingly automated technologies. Four ground control station operators performed multiple live flight operations. We employed a naturalistic approach and relied on qualitative data such as interviews and discussions with subject matter experts to help facilitate discovery. The present work evaluates the functions that the human and the automation had during the live operations, lists psychological constructs that may have promoted or reduced task performance, and provides recommendations on design of the remote operations environment and training of future ground control station operators.

Advanced Air Mobility↗

Quality of Life After Stereotactic Body Radiation Therapy for Primary and Metastatic Liver Tumors

Purpose: Stereotactic body radiation therapy (SBRT) provides a high local control rate for primary and metastatic liver tumors. The aim of this study is to assess the impact of this treatment on the patient's quality of life. This is the first report of quality of life associated with liver SBRT. Methods and Materials: From October 2002 to March 2007, a total of 28 patients not suitable for other local treatments and with Karnofsky performance status of at least 80% were entered in a Phase I-II study of SBRT for liver tumors. Quality of life was a secondary end point. Two generic quality of life instruments were investigated, EuroQol-5D (EQ-5D) and EuroQoL-Visual Analogue Scale (EQ-5D VAS), in addition to a disease-specific questionnaire, the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire (EORTC QLQ C-30). Points of measurement were directly before and 1, 3, and 6 months after treatment. Mean scores and SDs were calculated. Statistical analysis was performed using paired-samples t-test and Student t-test. Results: The calculated EQ-5D index, EQ-5D VAS and QLQ C-30 global health status showed that mean quality of life of the patient group was not significantly influenced by treatment with SBRT; if anything, a tendency toward improvement was found. Conclusions: Stereotactic body radiation therapy combines a high local control rate, by delivering a high dose per fraction, with no significant change in quality of life. Multicenter studies including larger numbers of patients are recommended and under development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of CO2 on Intracranial Hypertension in Spaceflight. Visual Impairment and Intracranial Hypertension: An Emerging Spaceflight Risk [Part 1 and 2]

A. CO2 - Acute: Given the history of uneven removal of CO2 from spacecraft areas, there is a history of acute illness that impacts short-term health and performance. 1) Acute CO2 symptoms occur in space flight due to a combination of CO2 scrubbing limitations, microgravity-related lack of convection, and possibly interaction with microgravity-related physiological changes. 2) Reported symptoms mainly include headaches, malaise, and lethargy. Symptoms are treatable with analgesics, rest, temporarily increasing scrubbing capability, and breathing oxygen. This does not treat the underlying pathology. 3)ld prevent occurrence of symptoms. B. CO2 - Chronic: Given prolonged exposure to elevated CO2 levels, there is a history that the long-term health of the crew is impacted. 1) Chronic CO2 exposures occur in space flight due to a combination of CO2 scrubbing limitations and microgravity-related lack of convection, with possible contribution from microgravity-related physiological changes. 2) Since acute symptoms are experienced at levels significantly lower than expected, there are unidentified long-term effects from prolonged exposure to elevated CO2 levels on orbit. There have been long term effects seen terrestrially and research needed to further elucidate long term effects on orbit. 3) Recommended disposition: Research required to further elucidate long term effects. In particular, elucidation of the role of elevated CO2 on various levels of CO2 vasodilatation of intracranial blood vessels and its potential contribution to elevation of intracranial pressure.

Fogarty, Jennifer A.↗

Interpreting SBUV Smoothing Errors: an Example Using the Quasi-biennial Oscillation

The Solar Backscattered Ultraviolet (SBUV) observing system consists of a series of instruments that have been measuring both total ozone and the ozone profile since 1970. SBUV measures the profile in the upper stratosphere with a resolution that is adequate to resolve most of the important features of that region. In the lower stratosphere the limited vertical resolution of the SBUV system means that there are components of the profile variability that SBUV cannot measure. The smoothing error, as defined in the optimal estimation retrieval method, describes the components of the profile variability that the SBUV observing system cannot measure. In this paper we provide a simple visual interpretation of the SBUV smoothing error by comparing SBUV ozone anomalies in the lower tropical stratosphere associated with the quasi-biennial oscillation (QBO) to anomalies obtained from the Aura Microwave Limb Sounder (MLS). We describe a methodology for estimating the SBUV smoothing error for monthly zonal mean (mzm) profiles. We construct covariance matrices that describe the statistics of the inter-annual ozone variability using a 6 yr record of Aura MLS and ozonesonde data. We find that the smoothing error is of the order of 1percent between 10 and 1 hPa, increasing up to 15-20 percent in the troposphere and up to 5 percent in the mesosphere. The smoothing error for total ozone columns is small, mostly less than 0.5 percent. We demonstrate that by merging the partial ozone columns from several layers in the lower stratosphere/troposphere into one thick layer, we can minimize the smoothing error. We recommend using the following layer combinations to reduce the smoothing error to about 1 percent: surface to 25 hPa (16 hPa) outside (inside) of the narrow equatorial zone 20 S-20 N.

ozone profile retrievals↗

Closure Report for Corrective Action Unit 547: Miscellaneous Contaminated Waste Sites, Nevada National Security Site, Nevada

This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 547, Miscellaneous Contaminated Waste Sites, and provides documentation supporting the completed corrective actions and confirmation that closure objectives for CAU 547 were met. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 as amended). CAU 547 consists of the following three Corrective Action Sites (CASs), located in Areas 2, 3, and 9 of the Nevada National Security Site: (1) CAS 02-37-02, Gas Sampling Assembly; (2) CAS 03-99-19, Gas Sampling Assembly; AND (3) CAS 09-99-06, Gas Sampling Assembly Closure activities began in August 2011 and were completed in June 2012. Activities were conducted according to the Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) for CAU 547 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2011). The recommended corrective action for the three CASs in CAU 547 was closure in place with administrative controls. The following closure activities were performed: (1) Open holes were filled with concrete; (2) Steel casings were placed over vertical expansion joints and filled with cement; (3) Engineered soil covers were constructed over piping and exposed sections of the gas sampling system components; (4) Fencing, monuments, Jersey barriers, radiological postings, and use restriction (UR) warning signs were installed around the perimeters of the sites; (5) Housekeeping debris was picked up from around the sites and disposed; and (6) Radiological surveys were performed to confirm final radiological postings. UR documentation is included in Appendix D. The post-closure plan was presented in detail in the CADD/CAP for CAU 547 and is included as Appendix F of this report. The requirements are summarized in Section 5.2 of this report. The proposed post-closure requirements consist of visual inspections to determine the condition of postings and radiological surveys to verify contamination has not migrated. NNSA/NSO requests the following: (1) A Notice of Completion from the Nevada Division of Environmental Protection to NNSA/NSO for closure of CAU 547; and (2) The transfer of CAU 547 from Appendix III to Appendix IV, Closed Corrective Action Units, of the FFACO.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-reported health impacts of do-it-yourself air cleaner use in a smoke-impacted community

Smoke exposure from wildfires or residential wood burning for heat is a public health problem for many communities. Do-It-Yourself (DIY) portable air cleaners (PACs) are promoted as affordable alternatives to commercial PACs, but evidence of their effect on health outcomes is limited. Pilot test an evaluation of the effect of DIY PAC usage on self-reported symptoms, and investigate barriers and facilitators of PAC use, among members of a tribal community that routinely experiences elevated concentrations of fine particulate matter (PM 2.5 ) from smoke. We conducted studies in Fall 2021 (“wildfire study”; N = 10) and Winter 2022 (“wood stove study”; N = 17). Each study included four sequential one-to-two-week phases: 1) initial, 2) DIY PAC usage ≥8 h/day, 3) commercial PAC usage ≥8 h/day, and 4) air sensor with visual display and optional PAC use. We continuously monitored PAC usage and indoor/outdoor PM 2.5 concentrations in homes. Concluding each phase, we conducted phone surveys about participants’ symptoms, perceptions, and behaviors. We analyzed symptoms associated with PAC usage and conducted an analysis of indoor PM 2.5 concentrations as a mediating pathway using mixed effects multivariate linear regression. We categorized perceptions related to PACs into barriers and facilitators of use. No association was observed between PAC usage and symptoms, and the mediation analysis did not indicate that small observed trends were attributable to changes in indoor PM 2.5 concentrations. Small sample sizes hindered the ability to draw conclusions regarding the presence or absence of causal associations. DIY PAC usage was low; loud operating noise was a barrier to use. This research is novel in studying health effects of DIY PACs during wildfire and wood smoke exposures. Such research is needed to inform public health guidance. Recommendations for future studies on PAC use during smoke exposure include building flexibility of intervention timing into the study design.

54 ENVIRONMENTAL SCIENCES↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response (CRADA Final Report)

LED luminaires with apertures containing visually resolvable “bright” (i.e., high luminance) spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were each shown 68 stimuli varying in spatial frequency, intensity, diffusion level, and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs, and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favor configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.

59 BASIC BIOLOGICAL SCIENCES↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

Energy Reporting: Device Demonstration, Communication Protocols, and Codes and Standards

Energy reporting is the principle that all energy-using devices in buildings should be able to track their own energy use and report this to the local network. Energy reporting can provide building owners with easy access to highly granular energy use data. This report makes the case that energy reporting should become a free basic feature of all devices, and reports on a project intended to move us towards that goal. The project collected a set of demonstration devices with energy reporting features, including products that were modified by the project team or the manufacturer, or are already available for sale. To show these devices operating live at meetings and conferences, the team created a management system that queries the energy reporting devices for their data, stores the data, and displays it in compelling visualizations. The devices covered a wide range, including heating, ventilation, and air conditioning (thermostat and air purifier); lighting (individual bulb, task light, and auto-dimming overhead light); a vehicle charger; a water heater; electronics (notebook personal computer and universal serial bus charger); and three external meters (one integral with a dimming light switch). The demonstration uses a variety of communication protocols. The report reviews existing communication protocols that support energy reporting and describes how to use them with a proposed reference data model for energy reporting. It also assesses ways that energy codes and standards processes can be leveraged to drive energy reporting technology into the market. Energy reporting could ultimately save California on the order of 2.5 terawatt-hours per year and about $0.8 billion per year. Energy reporting is a highly practical technology with minimal (sometimes no) cost to consumers and manufacturers. This report discusses creation of the energy reporting devices themselves, analysis and recommendations for data models and protocols for energy reporting, and energy codes and standards implications of energy reporting technology. While energy reporting does not directly save energy, it provides information for better decision-making to save energy in changing equipment operation, maintenance, and replacement.

devices↗

October 2008 monitoring results for Morrill, Kansas.

In September 2005, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) initiated periodic sampling of groundwater in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Morrill, Kansas. The sampling at Morrill is being performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE 2005), to monitor levels of carbon tetrachloride contamination identified in the groundwater at this site (Argonne 2004, 2005a). This report provides results for the most recent monitoring event, in October 2008. Under the KDHE-approved monitoring plan (Argonne 2005b), groundwater was initially sampled twice yearly for a period of two years (in fall 2005, in spring and fall 2006, and in spring and fall 2007). The samples were analyzed for volatile organic compounds (VOCs), as well as for selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. During the two-year period, the originally approved scope of the monitoring was expanded to include vegetation sampling (initiated in October 2006) and surface water and stream bed sediment sampling (initiated in March 2007, after a visual reconnaissance along Terrapin Creek [Argonne 2007a]). The analytical results for groundwater sampling events at Morrill in September 2005, March and September 2006, March and October 2007, and April 2008 were documented previously (Argonne 2006a,b, 2007b, 2008a,c). Those results consistently demonstrated the presence of carbon tetrachloride contamination, at levels exceeding the KDHE Tier 2 risk-based screening level (5.0 {micro}g/L) for this compound, in a groundwater plume extending generally south-southeastward from the former CCC/USDA facility, toward Terrapin Creek at the south edge of the town. Low levels ({le} 1.3 {micro}g/L) of carbon tetrachloride were persistently detected at monitoring well MW8S on the bank of an intermittent tributary to Terrapin Creek. This observation suggested a possible risk of contamination of the surface waters of the creek. That concern became the driving force for ongoing monitoring and consideration of possible remedial options for Morrill. In light of the early findings, in 2006 the CCC/USDA recommended expansion of the approved monitoring program to include the collection and analysis of surface water samples along Terrapin Creek (Argonne 2006a). At the request of the KDHE (2007a), locations for both surface water and shallow sediment sampling were discussed with the KDHE in January 2007. An addendum to the existing monitoring plan and a standard operating procedure (SOP AGEM-15) for sediment sampling were submitted to the KDHE on the basis of these discussions (Argonne 2007c,d). To supplement the original scope of the monitoring, Argonne also sampled natural vegetation along Terrapin Creek in October 2006, April 2007, and July 2007 for analyses for VOCs. The results of these plant tissue analyses were reported previously (Argonne 2008a). The October 2008 sampling event reported here represents a continuation of the two-year monitoring program, as requested by the KDHE (2007b). The groundwater sampling is presently conducted, in accord with the monitoring plan (Argonne 2005b) and the addendum to that plan (Argonne 2007a), in a network of 12 monitoring wells and 3 private wells (Figure 1.1), at locations approved by the KDHE.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-266: A Pitfall of a Deformable Image Registration in Lung Cancer

Purpose: For four-dimensional (4D) planning and adaptive radiotherapy, deformable image registration (DIR) is needed and the accuracy is essential. We evaluated the accuracy of one free-downloadable DIR software library package (NiftyReg) and one commercial DIR software (MIM) in lung SBRT cancer patients. Methods: A rigid and non-rigid registrations were implemented to our in-house software. The non-rigid registration algorithm of the NiftyReg and MIM was based on the free-form deformation. The accuracy of the two software was evaluated when contoured structures to peak-inhale and peak-exhale 4DCT image data sets were measured using the dice similarity coefficient (DSC). The evaluation was performed in 20 lung SBRT patients. Results: In our visual evaluation, the eighteen cases show good agreement between the deformed structures for the peak-inhale phase and the peak-exhale phase structures (more than 0.8 DSC value). In the evaluation of the DSC in-house software, averaged DSC values of GTV and lung, heart, spinal cord, stomach and body were 0.862 and 0.979, 0.932, 0.974, 0.860, 0.998, respectively. As the Resultof the registration using the MIM program in the two cases which had less than 0.7 DSC value when analyzed using the in-house software, the DSC value were improved to 0.8. The CT images in a case with low DSC value shows the tumor was surrounded by the structure with the similar CT values, which were the chest wall or the diaphragm. Conclusion: Not only a free-downloadable DIR software but also a commercial software may provide unexpected results and there is a possibility that the results would make us misjudge the treatment planning. Therefore, we recommend that a commissioning test of any DIR software should be performed before clinical use and we should understand the characteristics of the software.

60 APPLIED LIFE SCIENCES↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗

Enhancing the Useability of the IAEA's Physical Model: An Analysis of User Feedback

This study presents the results of Physical Model user interviews conducted with 12 people who have International Atomic Energy Agency (IAEA) safeguards experience. The goal of this report is to provide additional context for policy makers when prioritizing the needs of the IAEA regarding support for enhancements to the Physical Model. The interviews covered the general usability of the Physical Model, its effectiveness as a technical reference, and the scope and utility of the Physical Model's indicators and content. The key conclusions from these interviews are as follows: 1) The Physical Model is difficult to find and not well advertised. 2) The Physical Model can be difficult to use due to its format, which makes searching for information difficult, and lack of visual content. Therefore, the Physical Model should be supported in multiple formats (print, PDF, web) to maximize its usability for different stakeholders. 3) The scope of the Physical Model's content and indicators is likely sufficient, and translating indicators into other languages is unlikely to be worth the effort. 4) Despite its inefficiencies and other issues, the Physical Model in its current form is a vital (albeit under-utilized) resource for key stakeholders. 5) Despite its broad use case the Physical Model is not a catch-all tool and force-fitting the Physical Model into functions for which it has not been designed for would likely diminish its value. 6) It can be difficult to disentangle challenges related to the Physical Model and its usability from broader challenges at the Agency, such as general issues with communication and coordination. Based on these conclusions and considering the results of past studies on the Physical Model funded by NA-241, the analysis team developed a list of recommendations and associated actions for IAEA consideration. These recommendations are prioritized based on the assessed level of difficulty for the IAEA to implement a recommendation, emphasizing low hanging fruit then building to more ambitious changes to the Physical Model's format and content.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Flight validation of a pulsed smoke flow visualization system

A flow visualization scheme, designed to measure vortex fluid dynamics on research aircraft, was validated in flight. Strake vortex trajectories and axial core velocities were determined using pulsed smoke, high-speed video images, and semiautomated image edge detection hardware and software. Smoke was pulsed by using a fast-acting three-way valve. After being redesigned because of repeatedly jamming in flight, the valve shuttle operated flawlessly during the last two tests. A 25-percent scale, Gothic strake was used to generate vortex over the wing of a GA-7 Cougar and was operated at a local angle of attack of 22 degrees and Reynolds number of approximately 7.8 x 10(exp 5)/ft. Maximum axial velocities measured in the vortex core were between 1.75 and 1.95 times the freestream velocity. Analysis of the pulsed smoke system's affect on forebody vortices indicates that the system may reorient the forebody vortex system; however, blowing momentum coefficients normally used will have no appreciable affect on the leading-edge extension vortex system. It is recommended that a similar pulsed smoke system be installed on the F/A-18 High Angle Research Vehicle and that this approach be used to analyze vortex core dynamics during the remainder of its high-angle-of-attack research flights.

Ward, Donald T.↗

Environmental Baseline Survey Report for the Title Transfer of the K-792 Switchyard Complex at the East Tennessee Technology Park, Oak Ridge, Tennessee

This environmental baseline survey (EBS) documents the baseline environmental conditions of the U. S. Department of Energy's (DOE's) K-792 Switchyard Complex, which includes the former K-792 Switchyard, the K-79 1-B building, the K-796-A building, and the K-792 Northern Expansion Area located in the northwestern portion of the East Tennessee Technology Park (ETTP). The total area of the property is approximately 19.91 acres. DOE is proposing to transfer the title of this land area and buildings to the Heritage Center, LLC (Heritage Center), a subsidiary corporation of the Community Reuse Organization of East Tennessee (CROET). This report provides supporting information for the transfer of this government-owned facility at ETTP to a non-federal entity. The area proposed for title transfer includes the former K-792 Switchyard, the K-792 Northern Expansion Area, Bldg. K-791-B, Bldg. K-796-A, and the underlying property known as the underlying fee. Located within the K-792 Switchyard footprint but not included in the transfer are Bldg. K-131 0-MP and Bldg. K- 131 0-MQ, two buildings owned by a private company that leases space in the northern portion of the Switchyard. The transfer footprint is bounded by Perimeter Road to the north and west, the parking area for Portal 8 to the south, and primarily the former K-792 Powerhouse Complex and Avenue 'U' North to the east; however, the eastern boundary along the Northern Expansion area has no physical features associated with it. Zone 2 remedial action objectives were developed by the DVS to support the future use of ETTP as a mixed-use commercial and industrial park. Therefore, remediation criteria were designed for the protection of the future industrial worker under the assumption the worker normally would not have the potential for exposure to soils at depths below 10 ft below ground surface (bgs). Accordingly, land use controls (LUCs) have been established to restrict disturbance of soils below 10 ft deep and to limit future land use to industriallcornmercial activities. Where the need for LUCs below 10 ft bgs is not warranted, this is so stated and explained. Once all actions associated with the DVS for Zone 1 and Zone 2 are completed and the data support it, there will be a re-evaluation with EPA and TDEC for the restriction on excavation below 10 ft. The DVS process and the preparation of this report included visual and physical inspections of the property and adjacent properties, a detailed records search, sampling and analysis of soils, radiological walkover surveys, and a risk evaluation. Resources evaluated as part of the records search included Federal Government records, title documents, aerial photographs that may reflect prior uses, and interviews with current and former employees 1 involved in the operations on the real property to identify any areas on the property where hazardous substances and petroleum products, or their derivatives, and acutely hazardous wastes were stored for one year or more, known to have been released, or disposed of. In addition, radiological surveys of Bldgs. K-791-B and K-796-A were conducted to assess the buildings radiological condition. Soil vapor sampling and polychlorinated biphenyl (PCB) swipe sampling also were conducted within the buildings. Based on the U. S. Department of Energy's (DOE's) review of the existing information, including discussions and interviews referenced herein, and evaluation of the data gathered in preparation of the environmental baseline survey (EBS) for the K-792 Switchyard Complex, DOE recommends the following: Due to the uncertainty associated with the nature of the on-site groundwater and the need to evaluate and possibly address groundwater in the future, DOE recommends that the transfer of the K-792 Switchyard Complex be achieved by a covenant deferral per the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) Sect. 120(h)(3)(c). Land use restrictions associated with the covenant deferral are described.

54 ENVIRONMENTAL SCIENCES↗