Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume of fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Hybrid Thermal Control System for Extreme Thermal Environments

NASA’s return to the moon brings about many challenges, including issues with survival on the Lunar surface. Marshall Space Flight Center (MSFC) has been developing a hybrid thermal control system that can be utilized for various surface assets that must survive in extreme lunar environments. This scalable system is targeted for human-rated systems and utilizes a combination of a- pumped fluid loop (PFL) and a loop heat pipe (LHP) with thermal control valve (TCV). Pumped fluid loops have a long history of use in human rated systems. They can collect large amounts of waste heat and transport it over long distances in rovers, habitats, and other systems. By utilizing a non-toxic working fluid in the habitable volume, the PFL is easily serviceable by the crew and does not pose a risk during any unexpected leaks or failures. The addition of a LHP for the exterior heat transport and rejection adds several benefits to the system for extreme environment survival. The quantity of LHP scan be tailored to optimize heat rejection for different systems and allows for larger adiative surfaces. By utilizing a TCV in combination with the LHP, there can be high heat transfer during the daytime with minimal heat transfer during the night. The TCV passively controls the amount of heat transfer through the LHP based on the environmental temperature. A prototype system has been tested in bench top and thermal vacuum conditions. Results are presented showing the feasibility of the system concept.

Thermal Control↗

Hybrid Thermal Control System for Extreme Thermal Environments

NASA’s return to the moon brings about many challenges, including issues with survival on the Lunar surface. Marshall Space Flight Center (MSFC) has been developing a hybrid thermal control system that can be utilized for various surface assets that must survive in extreme lunar environments. This scalable system is targeted for human-rated systems and utilizes a combination of a- pumped fluid loop (PFL) and a loop heat pipe (LHP) with thermal control valve (TCV). Pumped fluid loops have a long history of use in human rated systems. They can collect large amounts of waste heat and transport it over long distances in rovers, habitats, and other systems. By utilizing a non-toxic working fluid in the habitable volume, the PFL is easily serviceable by the crew and does not pose a risk during any unexpected leaks or failures. The addition of a LHP for the exterior heat transport and rejection adds several benefits to the system for extreme environment survival. The quantity of LHP scan be tailored to optimize heat rejection for different systems and allows for larger adiative surfaces. By utilizing a TCV in combination with the LHP, there can be high heat transfer during the daytime with minimal heat transfer during the night. The TCV passively controls the amount of heat transfer through the LHP based on the environmental temperature. A prototype system has been tested in bench top and thermal vacuum conditions. Results are presented showing the feasibility of the system concept.

Thermal Control↗

A CFD Analysis of Hydrogen Leakage During On-Pad Purge in the ORION/ARES I Shared Volume

A common open volume is created by the stacking of the Orion vehicle onto the Ares I Upper Stage. Called the Shared Volume, both vehicles contribute to its gas, fluid, and thermal environment. One of these environments is related to hazardous hydrogen gas. While both vehicles use inert purge gas to mitigate any hazardous gas buildup, there are concerns that hydrogen gas may still accumulate and that the Ares I Hazardous Gas Detection System will not be sufficient for monitoring the integrated volume. This Computational Fluid Dynamics (CFD) analysis has been performed to examine these topics. Results of the analysis conclude that the Ares I Hazardous Gas Detection System will be able to sample the vent effluent containing the highest hydrogen concentrations. A second conclusion is that hydrogen does not accumulate under the Orion Service Module (SM) avionics ring as diffusion and purge flow mixing sufficiently dilute the hydrogen to safe concentrations. Finally the hydrogen concentrations within the Orion SM engine nozzle may slightly exceed the 1 percent volume fraction when the entire worse case maximum full leak is directed vertically into the engine nozzle.

Ajmani, Kumud↗

Method of delivering lunar generated fluid to earth orbit using an external tank

A method and apparatus are provided for delivering lunar generated fluid to Earth orbit from lunar orbit. Transport takes place in an external tank of a shuttle which has been suitably outfitted in Earth orbit for reusable travel between Earth orbit and a lunar orbit. The outfitting of the external tank includes the adding of an engine, an electrical system, a communication system, a guidance system, an aerobraking device, and a plurality of interconnected fluid storage tanks to the hydrogen and oxygen tanks of the external tank. The external tank is then propelled to lunar orbit the first time using Earth-based propellant. In lunar orbit, the storage tanks are filled with the lunar generated fluid with the remainder tank volumes filled with lunar generated liquid oxygen and hydrogen which serve as propellants for returning the tank to Earth orbit where the fluid is off-loaded. The remaining lunar generated oxygen and hydrogen is then sufficient to return the external tank to lunar orbit so that a subsequent cycle of fluid delivery is repeated. A space station in a higher Earth orbit is preferably used to outfit the external tank, and a lunar node in lunar orbit is used to store and transfer the fluid and liquid oxygen and hydrogen to the external tank. The lunar generated fluid is preferably .sup.3 He.

Butterfield, Ansel J.↗

The CMC/3DPNS computer program for prediction of three-dimension, subsonic, turbulent aerodynamic juncture region flow. Volume 2: Users' manual

The CMC fluid mechanics program system was developed to transmit the theoretical solution of finite element numerical solution methodology, applied to nonlinear field problems into a versatile computer code for comprehensive flow field analysis. Data procedures for the CMC 3 dimensional Parabolic Navier-Stokes (PNS) algorithm are presented. General data procedures a juncture corner flow standard test case data deck is described. A listing of the data deck and an explanation of grid generation methodology are presented. Tabulations of all commands and variables available to the user are described. These are in alphabetical order with cross reference numbers which refer to storage addresses.

Manhardt, P. D.↗

The CMC/3DPNS computer program for prediction of three-dimensional, subsonic, turbulent aerodynamic juncture region flow. Volume 3: Programmers' manual

The CMC fluid mechanics program system was developed to transmit the theoretical evolution of finite element numerical solution methodology, applied to nonlinear field problems into a versatile computer code for comprehensive flow field analysis. A detailed view of the code from the standpoint of a computer programmer's use is presented. A system macroflow chart and detailed flow charts of several routines necessary to interact with a theoretican/user to modify the operation of this program are presented. All subroutines and details of usage, primarily for input and output routines are described. Integer and real scalars and a cross reference list denoting subroutine usage for these scalars are outlined. Entry points in dynamic storage vector IZ; the lengths of each vector accompanying the scalar definitions are described. A listing of the routines peculiar to the standard test case and a listing of the input deck and printout for this case are included.

Orzechowski, J. A.↗

Effect Of Leg Exercise On Vascular Volumes During Bed Rest

Report describes experiments on effects of no-exercise regimen and of two leg-exercise regimens on volumes of plasma, volumes of red blood cells, densities of bodies, and water balances of 19 men (32 to 42 years old) confined to minus 6 degrees-head-down bed rest for 30 days. Purpose of study to determine whether either or both exercise regimens maintain plasma volume and to relate levels of hypovolemia to body fluid balances. Results showed during bed rest, plasma volume maintained in isotomic group but not in other two groups, and no significant differences in body densities, body weights, or water balances among three groups. Concludes isotonic-exercise regimen better than isokinetic-exercise regimen for maintaining plasma volume during prolonged exposure to bed rest.

Greenleaf, J. E.↗

Lower body negative pressure - The second manned Skylab mission

Results of orthostatic evaluations of the crew of Skylab 3 with lower body negative pressure (LBNP) stress tests during their 59-d mission are reported. Except for an inflight increase (rather than a decrease) in resting heart rates, results were essentially parallel to those observed in crewmen of the shorter Skylab 2 mission. Exaggerated elevations in heart rate and decreases in pulse pressure during LBNP stress inflight and immediately postflight corresponded to lowered orthostatic tolerance. Large decrements is resting calf size inflight and in total leg volume postflight indicated significant headward fluid shifts as had already been seen in the Skylab 2 crewmen. In addition, decreases in calf circumference gave no certain indication of a plateau over the 59 d inflight. Percentage volume increase in calf size during LBNP stress inflight was greater than those in either preflight or postflight tests.

Johnson, R. L.↗

Assessment of Intraocular and Systemic Vasculature Pressure Parameters in Simulated Microgravity with Thigh Cuff Countermeasure

Changes in vision have been well documented among astronauts during and after long-duration space flight. One hypothesis is that the space flight induced headward fluid alters posterior ocular pressure and volume and may contribute to visual acuity decrements. Therefore, we evaluated venoconstrictive thigh cuffs as a potential countermeasure to the headward fluid shift-induced effects on intraocular pressure (IOP) and cephalic vascular pressure and volumes.

Huang, Alex S.↗

Development of an Atomization Methodology for Spray Combustion

In liquid rocket propulsion, the knowledge and the understanding of liquid-gas interfacial phenomena are very important. This is important for predicting the onset of cavitation occurring in swirl injection elements used in STME, as well as atomization processes in shear-induced injectors (co-axial) and impinging injector elements. From the fact that all the physical processes including droplet size distribution, droplet dispersion, mixing and combustion are controlled by atomization processes, it is expected that the successful incorporation of the volume of fraction (VOF) will greatly enhance the analytical capability of predicting spray combustion processes in liquid-fueled engines. In this paper, a methodology is developed to define and track interfaces between two fluids in non-orthogonal, body-fitted grids using a single fractional volume of fluid (VOF) variable to describe the distribution of the liquid phase in a gas-liquid flow field. This method was implemented in a mature CFD code MAST (Multiphase All-Speed Transient) utilizing the general PISO-C algorithm. For the preliminary study on the analysis of spray combustion and tracking of the interface between two phases, we will report on the progress of the simulation of the instability on the liquid column; the surface wave instability and the droplet breakup from the liquid surface.

Seung, S. P.↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

Fluid shifts in vascular and extravascular compartments of humans during and after simulated weightlessness

A study is presented of the transcapillary pressures and the possible fluid shifts in muscles and subcutaneous tissue of the lower leg before, during, and after head-down tilt. Results showed that the subjects experienced facial edema, headache, nasal congestion, diuresis, and decreased lower-leg volume in response to 8 hours of 5 degree head-down tilt. Also found were significant decreases in systolic and diastolic pressures 2 hours after initiation of tilt, although blood pressure normalized thereafter. The lower-leg volume, urine output and interstitial fluid pressures of the tibialis anterior muscle and overlying subcutaneous tissue also changed significantly. No significant change was found in the colloid osmotic pressures of blood or interstitial fluid. It is concluded that these results indicate the need for countermeasures to maintain precapillary-muscle tone during long space flights in order to prevent swelling of lower-leg tissues upon readjustment to earth's gravity.

Hargens, A. R.↗

ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

Roder, H. M.↗

SRM Internal Flow Tests and Computational Fluid Dynamic Analysis: Cold Flow Analyses and CFD Analysis Capability Development - Volume 4

An evaluation of the effect of model inlet air temperature drift during a test run was performed to aid in the decision on the need for and/or the schedule for including heaters in the SRMAFTE. The Sverdrup acceptance test data was used to determine the drift in air temperature during runs over the entire range of delivered flow rates and pressures. The effect of this temperature drift on the model Reynolds number was also calculated. It was concluded from this study that a 2% change in absolute temperature during a test run could be adequately accounted for by the data analysis program. A handout package of these results was prepared and presented to ED35 management.

Source record↗

Drug effects on orthostatic intolerance induced by bedrest

Effective and practical preventive procedures for postflight orthostatic intolerance are highly desirable. The current practice of attempts to expand plasma volume by ingestion of salt and fluids before reentry has proven benefits. This study evaluated alternative options using fludrocortisone (F) to expand plasma volume (PV), dextroamphetamine (Dex) to enhance norepinephrine (NE) release, and atropine (A) to reduce the effects of vagal stimulation. Seven subjects with proven post-bedrest orthostatic intolerance returned for a 7-day 6-deg head-down bedrest study. F (0.2 mg) was given at 8:00 AM and 8:00 PM the day before and 8:00 AM the day the subjects got out of bed (2 hours before standing). PV was measured before and 1 hour after the last dose of F. Dex (5 mg) and A (0.8 mg) were then taken orally 1 hour before the stand test. F expanded PV by 16 percent and caused sodium retention. Four of the 7 subjects stood for 1 hour post-bedrest and heart rate, plasma NE and plasma renin responses to standing were greatly enhanced and sustained. Although there was a narrowing of pulse pressure, the ability to overcome orthostatic intolerance with these countermeasures was largely due to vasoconstriction and sustained high heart rate.

Vernikos, J.↗

Gauging Systems Monitor Cryogenic Liquids

Rocket fuel needs to stay cool - super cool, in fact. The ability to store gas propellants like liquid hydrogen and oxygen at cryogenic temperatures (below -243 F) is crucial for space missions in order to reduce their volumes and allow their storage in smaller (and therefore, less costly) tanks. The Agency has used these cryogenic fluids for vehicle propellants, reactants, and life support systems since 1962 with the Centaur upper stage rocket, which was powered with liquid oxygen and liquid hydrogen. During proposed long-duration missions, super-cooled fluids will also be used in space power systems, spaceports, and lunar habitation systems. In the next generation of launch vehicles, gaseous propellants will be cooled to and stored for extended periods at even colder temperatures than currently employed via a process called densification. Densification sub-cools liquids to temperatures even closer to absolute zero (-459 F), increasing the fluid s density and shrinking its volume beyond common cryogenics. Sub-cooling cryogenic liquid hydrogen, for instance, from 20 K (-423 F) to 15 K (-432.4 F) reduces its mass by 10 percent. These densified liquid gases can provide more cost savings from reduced payload volume. In order to benefit from this cost savings, the Agency is working with private industry to prevent evaporation, leakage, and other inadvertent loss of liquids and gases in payloads - requiring new cryogenic systems to prevent 98 percent (or more) of boil-off loss. Boil-off occurs when cryogenic or densified liquids evaporate, and is a concern during launch pad holds. Accurate sensing of propellants aboard space vehicles is also critical for proper engine shutdown and re-ignition after launch, and zero boil-off fuel systems are also in development for the Altair lunar lander.

Source record↗

A continuum theory of a lubrication problem with solid particles

The governing equations for a two-dimensional lubrication problem involving the mixture of a Newtonian fluid with solid particles at an arbitrary volume fraction are developed using the theory of interacting continuua (mixture theory). The equations take the interaction between the fluid and the particles into consideration. Provision is made for the possibility of particle slippage at the boundaries. The equations are simplified assuming that the solid volume fraction varies in the sliding direction alone. Equations are solved for the velocity of the fluid phase and that of the solid phase of the mixture flow in the clearance space of an arbitrary shaped bearing. It is shown that the classical pure fluid case can be recovered as a special case of the solutions presented. Extensive numerical solutions are presented to quantify the effect of particulate solid for a number of pertinent performance parameters for both slider and journal bearings. Included in the results are discussions on the influence of particle slippage on the boundaries as well as the role of the interacting body force between the fluid and solid particles.

Dai, Fuling↗