Search NASA⌕ Search

SEARCH · Search NASA

Results for “water temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Multiple redox mechanisms for water-gas shift reaction on Fe 3 O 4 (1 1 1) surface: A density functional theory and mean-field microkinetic modeling study

In this work, we investigated redox mechanisms for the high temperature (HT) water–gas shift reaction (WGSR) on the Fe 3 O 4 (1 1 1) surface using density functional theory (DFT) calculations and mean-field microkinetic modeling (MKM). The redox pathways branched into three Langmuir-Hinshelwood processes (LH1, LH2 and LH3) and one Mars-van-Krevelen (MVK) process (in the presence of oxygen vacancy) from multidentate binding of CO and CO 2 over four available reactive sites (Fe oct2 , Fe tet1 , Fe bridge, and O1). We found that the LH1 and LH2 processes have CO adsorption at a single iron site (Fe oct2 or Fe tet1 ), while the LH3 and MVK processes have stronger chemisorption of CO or CO 2 by both the Fe oct2 site and the O 1 site. From the mechanistic study of these reaction path, we recognized that availability of O 1 sites was key to proceed to either CO oxidation by the single site (LH1, LH2) or by the dual site (LH3, MVK). We observed that the reaction energetics were significantly different in the CO oxidation steps, where the single or dual site results in markedly different apparent activation energy (73–281 kJ/mol) and reaction rates (10 -3 –10 -10 mol∙m -2 ∙s -1 ) among the four reaction mechanisms. The utilization of mean field MKM with DFT reaction energetics helps explain the experimental debates for the catalytic reaction details as well as providing a possible direction to engineer the catalyst with higher activity.

42 ENGINEERING↗

A novel green hydrogen production using water-energy nexus framework

The transformation of electrical energy to hydrogen via water electrolysis consumes considerable amount of fresh water and a productive use of nontraditional water sources enhances the reliability and resilience of energy and water systems. In this study, we have designed a solid oxide electrolysis cell (SOEC) system which is an evolving hydrogen production technology at high temperatures for water electrolysis. Here, the SOEC uses steam generated from flue gas as its feedstock and is fully integrated with numerous power production units, including coal and natural gas-fired power plants as its energy feedstock. While there is a hasten global shift away from fossil fuel, integrating its asset into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. But high capital expenditures and doubt concerning the future cost and efficiency upgrade are obstacles to investing in water electrolysis. Such a detailed Levelized cost of hydrogen and techno-economic analysis is conducted to show the viability and environmental impacts of this novel technology. The results show SOEC efficiency of 97.4 % and 56.3 % as thermal-to-hydrogen efficiency of the system with a daily hydrogen production of 242,400 kg at $2.9–3.5/kg H 2 . The estimates show a positive gain prospect in this technology and techno-economic challenges.

08 HYDROGEN↗

EARLY HAWAIIANS AND VOLCANIC HEAT

This research serves as the first-known compilation of accounts of early Hawaiians using volcanic heat. Western explorers in the 1800s wrote about native Hawaiians near $K\bar{i}lauea$ Volcano using volcanic heat for cooking and bathing. They cooked their food wrapped in leaves underground or above a steam crack at Sulphur Banks, $K\bar{i}lauea$ Iki, and the $N\bar{a}pau$ Crater Trail. Early Hawaiians bathed in the warm waters of Waiwelawela for health. To confirm the presence of volcanic heat, this study used geothermal resource maps by the Hawai‘i Play Fairway project. According to a probability map for volcanic heat, the areas where Hawaiians used volcanic heat have a probability of volcanic heat of 0.8 to 1.0. On a map with temperatures of water wells, water wells close to where Hawaiians used volcanic heat have elevated temperatures. Historically, the areas where Hawaiians used volcanic heat experienced volcanic steam release, volcanic eruptions, and lava flows.

Geology↗

Experimental measurements of fuel and water crossover in an active DMFC

This work measured polarization curves as well as the high-frequency resistance of active direct methanol fuel cell (DMFC) operates at around 80 °C with active controls of temperature, methanol concentration, airflow rate, and relative humidity. The relative humidity of the air did not have noticeable impacts on the fuel cell unless the operating temperature was near the evaporation temperature of water (100 °C). The hydrophobic water management layer (WML) between the membrane electrode assembly (MEA) and cathode air channel increases the mass transfer resistance and improves the water retention in MEA. Adding a WML increased the peak power density, decreased the ohmic resistance, and improved the fuel efficiency of the fuel cell, especially when it operated near 100 °C. This study also quantitatively measured methanol and water crossover as well as the fuel efficiency at different operating currents. The fuel efficiency increased significantly with the increase of the current density. Using a hydrophobic fuel management layer (FML) between the anode fuel channel and MEA reduced the fuel and water crossover rates and increased the ohmic resistance due to the decrease of the water content of the Nafion membrane. The FML improved fuel efficiency by reducing the methanol crossover. The combination of the FML and WML enabled the steady operation of DMFC using highly concentrated methanol solutions (up to 75 wt%).

08 HYDROGEN↗

Coexistence of vitreous and crystalline phases of H 2 O at ambient temperature

Formation of vitreous ice during rapid compression of water at room temperature is important for biology and the study of biological systems. Here, we show that Raman spectra of rapidly compressed water at greater than 1 GPa at room temperature exhibits the signature of high-density amorphous ice, whereas the X-ray diffraction (XRD) pattern is dominated by crystalline ice VI. To resolve this apparent contradiction, we used molecular dynamics simulations to calculate full vibrational spectra and diffraction patterns of mixtures of vitreous ice and ice VI, including embedded interfaces between the two phases. We show quantitatively that Raman spectra, which probe the local polarizability with respect to atomic displacements, are dominated by the vitreous phase, whereas a small amount of the crystalline component is readily apparent by XRD. The results of our combined experimental and theoretical studies have implications for detecting vitreous phases of water, survival of biological systems under extreme conditions, and biological imaging. The results provide additional insight into the stable and metastable phases of H 2 O as a function of pressure and temperature, as well as of other materials undergoing pressure-induced amorphization and other metastable transitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SPRUCE Whole Ecosystem Warming (WEW) Environmental Data and Water Table Summaries, Marcell Experimental Forest, Minnesota, 2015-2024

This data set contains observations of photosynthetically active radiation (PAR), precipitation, soil temperature, soil volumetric water content, air temperature, relative humidity, and normalized water table depth that are summarized on a daily, weekly, monthly, and annual basis for each of the SPRUCE plots. Observations span 2015-2024. This dataset draws on several datasets (Hanson et al. 2016; Hanson et al. 2020; and Warren, unpublished data) and compiles these environmental observations into useful formats for data analysis. These environmental metrics can be used to understand the environmental conditions inside SPRUCE environmental chambers throughout the durations of the experiment and can be paired with other data for modeling and analysis. R code used to generate these files is provided as part of the data package. This dataset contains four data files in comma separate (.csv) format and a compressed folder (*.zip) containing three R (*.r) scripts. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format. User note: Users must cite the original dataset/s along with this dataset when publishing any analyses using this dataset. Details on the dataset used to compile each variable are available in the header row of the files and in the user guide.

air temperature↗

Vortex Structure of Head Bubble in Convective Cloud Starting Plume

Abstract A developing cumulus cloud (Cu) was modeled, and dynamic, thermodynamic, and microphysical properties of an ascending head bubble reproducing the upper part of a developing Cu were investigated. The data for analysis are taken from 10-m-resolution LES of trade wind Cu under BOMEX conditions. The detection of a rising bubble is carried out using wavelet filtering of the velocity fields and microphysical fields, while a low-frequency signal of the filtering is associated with the convective-scale structure of cloud. We substantiate and discuss the representation of the bubble as a vortex ring, and estimate the parameters of this vortex ring. The simplest Hill’s vortex was chosen as a model of a vortex ring inside cloud. Analytical approximations of the radial profiles of the vertical velocity and of conservative quantities (such as total water mixing ratio and liquid water potential temperature inside and outside the bubble) are obtained. The spatial structure of these quantities is investigated using analytical expressions. Analytical models for spatial distributions of liquid water content (LWC) and adiabatic fraction (AF) are also designed and analyzed. The results demonstrate the existence of a cloud core with high values of LWC and AF up to the height of 1800 m. The horizontally averaged value of the adiabatic fraction, calculated analytically using the Hill’s vortex concept, is evaluated as 0.39, which is the typical AF value in the upper parts of such Cu. The vertical profiles of different important quantities characterizing cloud structure are presented. The analysis performed in this study allows us to conclude that a rising vortex ring plays the dominating role in formation of the thermodynamic and microphysical structure of developing Cu. Significance Statement 1) Dynamic and thermodynamic fields of a developing cumulus cloud simulated by high-resolution LES with spectral bin microphysics are separated into convective and turbulent components by means of the wavelet technique. 2) The analysis of convective component of the cloud revealed the existence of a vortex ring at the developing stage of the cloud and evaluate its parameters. 3) The analysis performed in this study allows us to conclude that a rising vortex ring plays the important role in formation of the thermodynamic and microphysical structure of developing Cu. 4) The study provides a novel insight into the cloud–environment interaction. 5) The approximating equations describing the vortex ring can be usefully applied for developing new schemes of convective parameterization.

Meteorology & Atmospheric Sciences↗

Shock‐tube spectroscopic water measurements and detailed kinetics modeling of 1‐pentene and 3‐methyl‐1‐butene

Abstract To understand the effects of the chemical structure of two C 5 alkene isomers on their combustion properties, and to highlight the major chemical reactions occurring during their high‐temperature oxidation, water time histories were measured behind reflected shock waves for the oxidation of 1‐pentene (C 5 H 10 ‐1) and 3‐methyl‐1‐butene (3M1B) in 99.5% Ar. The experiments were carried out at three different equivalence ratios ( φ = 0.5, 1.0, and 2.0) at pressures and temperatures ranging from 1.29 to 1.47 atm and 1 331 to 1 877 K, respectively. The H 2 O quantification extends the database for 1‐pentene and provides new insights for 3M1B. These unique results were used to validate and to develop a new detailed kinetics model. Numerical predictions are presented, and the new model was able to capture the results with suitable accuracy, with 3M1B being notably more reactive than C 5 H 10 ‐1. Sensitivity and rate‐of‐production analyses were performed to help explain the results. Under the present conditions, the reactivity is rapidly initiated by molecular dissociation of a fraction of the pentene isomers. The initiation phase then induces H‐atom abstraction by active radicals (H, OH, O, HO 2 , and CH 3 ) to first produce alkenyl C 5 H 9 radicals (or an alkyl radical and an alkenyl radical by breaking a C─C bond) and subsequent, smaller fragments. The difference in terms of reactivity between the isomers is essentially due to the fact that 3M1B has one particularly weak tertiary allylic C─H bond, which allows for fast H‐atom abstraction compared with 1‐pentene.

Grégoire, Claire M.↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Dimensionless parameters for cloudy Rayleigh-Bénard convection: Supersaturation, Damköhler, and Nusselt numbers

In steady-state Rayleigh-Bénard convection, heat is transported by turbulent thermal convection from the bottom, hot surface to the top, cold surface, leading to a height-independent sensible heat flux. When water vapor is present and cloud formation occurs, there is also an additional latent heat flux. Heat transport in cloudy Rayleigh-Bénard convection depends on turbulent flow as well as the microphysical state of the clouds: specifically, whether substantial supersaturations exist and whether cloud liquid water is removed through sedimentation/precipitation. In this article we bridge between the Rayleigh-Bénard convection literature and the atmospheric literature. We express the governing equations for cloudy convection in dimensionless form, thereby explicitly identifying the governing parameters relevant to the cloudy case, including Schmidt, Damköhler, supersaturation, and sedimentation numbers. We further connect to the atmospheric literature by obtaining a Nusselt number (dimensionless heat flux) for a cloud-convection system, directly from the conservation equations for temperature and water vapor. This flux has the same form as that identified by Zhang et al. [L. Zhang, K. L. Chong, and K.-Q. Xia, J. Fluid Mech. 874, 1041 (2019)] for convection with water vapor, but is extended to the cloudy case. For equal thermal and water vapor diffusivities, the flux corresponds to the widely used atmospheric quantities equivalent temperature and moist static energy. Using large eddy simulation (LES) of an idealized cloudy Rayleigh-Bénard convection system with fixed boundary conditions, we find that the equivalent heat flux (Nusselt number) is only weakly dependent on the microphysical details of the system, such as liquid water mixing ratio and cloud droplet number concentration. Finally, from the results, we show the vertical profiles of sensible and latent heat fluxes depend on the liquid water content, whereas the equivalent heat flux remains a constant throughout the height of the chamber.

54 ENVIRONMENTAL SCIENCES↗

TARP Identifying Critical Thresholds for Acute Response of Plants and Ecosystems to Water Stress at Walker Branch Watershed, 2002-2005

This dataset contains data from a manipulative field study aimed at identifying critical thresholds for acute response of plants and ecosystems to water stress (TARP) that took place at Walker Branch Watershed in Oak Ridge, Tennessee from 2002-2005 (2002-06-20 to 2005-12-16). The study used understory tents for the removal of 100% of the growing-season throughfall and stem flow, to provide data on the impact of acute drought on mechanisms responsible for growth and mortality of deciduous forest canopy trees representative of common plant functional types (Liriodendron and Quercus). Through three years of manipulation (2003, 2004 and 2005; pretreatment measurements in 2002) various measures of tree response to surface moisture deficits were recorded including root and leaf traits, plant nonstructural carbohydrates status, hourly sapflow, basal area, and periodic observations of foliar photosynthesis and conductance. Additionally, environmental data such as air and soil temperature, soil water content, and soil matric potential were recorded. This dataset contains data 16 files in comma-separate (*.csv) format. Additional metadata are provided: 16 data dictionaries and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.

basal area↗

Contrasting thermally-induced structural and microstructural evolution of alumino-silicates with tubular and planar arrangements: Case study of halloysite and kaolinite

Materials with the similar chemical structures but different morphological organization exhibit considerable differences in thermally induced chemo-morphological evolution. With recent advancements in multi-scale X-ray scattering measurements, it is now possible to non-invasively probe the structural and microstructural evolution of such materials. In this study, we investigate the chemo-morphological evolution of halloysite and contrast the results with those for kaolinite. Halloysite and kaolinite have tubular and planar morphologies, respectively. Both materials are alumino-silicates comprising silica tetrahedra (T) and alumina octahedra (O) organized in a TO structure. Four distinct stages in the structural evolution were identified. Stages I, II, III, and IV correspond to temperature ranges of 25 to 125 °C, 125 to 400 °C, 400 to 625 °C, and 625 to 875 °C. Major structural changes correspond to the removal of interlayer/adsorbed water in stage I, the existence of the halloysite structure without interlayer water in stage II, dehydroxylation of halloysite in stage III, and the conversion of ordered halloysite to amorphous meta-halloysite in stage IV. Additionally, heating halloysite up to 875 °C resulted in slight widening of the nanotubes, as the average pore radius increased from 6.4 nm to 6.6 nm. Heating also resulted in an increase of wall thickness of the nanotubes from ~120 nm (25 °C) to 161 nm (875 °C). The increase in the halloysite nanotube diameter was attributed to the expansion of the structure and an increase in the surface roughness. The pore sizes in halloysite nanotubes were also confirmed using N 2 adsorption-desorption and nano-X-ray computed tomography (nano-XCT) measurements. The interlayer basal spacing in halloysite changed from 9.8 Å to 7.2 Å after the removal of interlayer water. At temperatures in the range of 625 to 875 °C, heating halloysite causes a small widening of nanotube pores and a minor increase in the surface area. In contrast, the interlayer spacing in kaolinite collapses on heating which reduces the nanoscale porosity. Furthermore, these studies demonstrate the differences in the chemo-morphological evolution of alumino-silicates with tubular and planar morphologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A review of coarse mineral dust in the Earth system

Mineral dust particles suspended in the atmosphere span more than three orders of magnitude in diameter, from <0.1 µm to more than 100 µm. This wide size range makes dust a unique aerosol species with the ability to interact with many aspects of the Earth system, including radiation, clouds, hydrology, atmospheric chemistry, and biogeochemistry. This review focuses on coarse and super-coarse dust aerosols, which we respectively define as dust particles with a diameter of 2.5–10 µm and 10–62.5 µm. We review several lines of observational evidence indicating that coarse and super-coarse dust particles are transported farther than previously expected and that the abundance of these particles is substantially underestimated in current global models. We synthesize previous studies that used observations, theories, and model simulations to highlight the impacts of coarse and super-coarse dust aerosols on the Earth system, including their effects on dust-radiation interactions, dust-cloud interactions, atmospheric chemistry, and biogeochemistry. Specifically, coarse and super-coarse dust aerosols produce a net positive direct radiative effect (warming) at the top of the atmosphere and can modify temperature and water vapor profiles, influencing the distribution of clouds and precipitation. In addition, coarse and super-coarse dust aerosols contribute a substantial fraction of ice-nucleating particles, especially at temperatures above –23 °C. They also contribute a substantial fraction to the available reactive surfaces for atmospheric processing and the dust deposition flux that impacts land and ocean biogeochemistry by supplying important nutrients such as iron and phosphorus. Furthermore, we examine several limitations in the representation of coarse and super-coarse dust aerosols in current model simulations and remote-sensing retrievals. Because these limitations substantially contribute to the uncertainties in simulating the abundance and impacts of coarse and super-coarse dust aerosols, we offer some recommendations to facilitate future studies. Overall, we conclude that an accurate representation of coarse and super-coarse properties is critical in understanding the impacts of dust aerosols on the Earth system.

54 ENVIRONMENTAL SCIENCES↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Oxygen Evolution Electrode

Water electrolysis using an anion conductive, solid polymer electrolyte is an attractive method for point-of-use hydrogen production. Recent advances in catalysts and anion exchange membranes (AEM) have made alkaline devices increasingly competitive with their acidic counterparts. However, less attention has been paid to the anion conductive ionomers (ACI) used in the fabrication of electrodes for AEM electrolyzers. The ACI contributes to ion conduction between the catalyst and bulk electrolyte and serves as a binder for adhering the catalyst to the gas diffusion layer and AEM. Ionic conductivity, water uptake and ionomer swelling are critical properties for electrode performance. High ion exchange capacity (IEC) in the ionomer is desired for reduced electrode resistance, however, it can lead to excess water uptake (WU) and disruptive ACI swelling. In this study, a series of poly(norbornene)-based ionomers were synthesized, characterized and used to fabricate oxygen evolving anodes for low-temperature AEM water electrolysis. The IEC of the ionomers (0 to 4.73 meq g −1 ) was adjusted by controlling the ratio of ion conducting to non-ion conducting norbornene monomers in the ACI tetrablock copolymers. Low conductivity ionomers are shown to yield the best-performing oxygen evolution electrodes, in the absence of ACI polymer cross-linking because they do not experience excessive water swelling. Light cross-linking within the anode ACI was used as a means to independently lower WU of the ionomer without compromising ionic conductivity. This control over water swelling allows higher ionic conductivity within the ACI to be used in water-fed electrolyzer applications. Other methods of water management were compared including the use of hydrophobic additives and adjustment of the ionomer concentration in the electrode. As a result, it was shown that the cell performance greatly benefits from a highly conductive ionomer in the oxygen evolution reaction electrode if the WU is managed.

08 HYDROGEN↗

Improved method for temporally interpolating radiosonde profiles in the convective boundary layer

A significantly improved technique for temporally interpolating radiosonde (RS) profiles of potential temperature and water vapor mixing ratio in the planetary boundary layer during daytime is introduced. The key innovation of this technique is its operation on a height grid normalized with the planetary boundary layer height. This study utilized a three-month dataset of three-hourly soundings from the Atmospheric Radiation Measurement Facility's Southern Great Plains site. The technique was evaluated for convective boundary layer cases, with the necessary boundary layer height data obtained from a ground-based infrared spectrometer. A total of 79 comparisons were conducted between reference soundings and interpolated profiles that did and did not employ height normalization. The results demonstrated a substantial improvement in the representation of interpolated profiles using the new technique, characterized by enhanced correlation, improved amplitude representation, and reduced bias for potential temperature, as well as improved correlation and reduced bias for water vapor mixing ratio.

convective boundary layer↗

Modeling a Water-Cooled Printed Circuit Heat Exchanger Condensing CO2 for use in SCO2 Cycle System Optimization Studies

This work describes a one-dimensional model of a water-cooled printed circuit heat exchanger (PCHE) condensing supercritical CO2. The model is developed for use in cycle optimization studies (e.g., minimizing levelized cost of electricity) as either the main heat rejection cooler and/or a compressor intercooler for recompression closed Brayton supercritical CO2 power cycles. Sensitivity and case studies are used to illustrate the impact of important model parameters, and this includes allowing for independent variation of zig-zag channel wave angles on the CO2 and water side. Results show that for a given CO2 design pressure (and thus saturation temperature), the PCHE design inlet water temperature has a significant impact on the PCHE size. Results also demonstrate that if wave angles are the same on the CO2 and water side, the water side pressure drop will have more influence on determining the optimum PCHE mass than the CO2 side pressure drop. Reducing the water side wave angle to near straight channel flow offers a more compact design for a similar water side pressure drop (and pump power requirement). Cases are also shown for further increasing the compactness and how the PCHE mass is affected along with water pump power.

Liese, Eric↗