Search NASA⌕ Search

SEARCH · Search NASA

Results for “weights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Weighting Factors for the Commercial Building Prototypes Used in the Development of ANSI/ASHRAE/IESNA Standard 90.1-2010

Detailed construction data from the McGraw Hill Construction Database was used to develop construction weights by climate zones for use with DOE Benchmark Buildings and for the ASHRAE Standard 90.1-2010 development. These construction weights were applied to energy savings estimates from simulation of the benchmark buildings to establish weighted national energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lignin molecular weights of Populus trichocarpa residues after CELF pretreatment

Here we present a dataset of molecular weights of lignin from a woody energy crop (Populus trichocarpa) residues after a series of co-solvent enhanced lignocellulosic fractionation (CELF) pretreatment. The natural poplar variant GW-9947 from the Center for Bioenergy Innovation (CBI) was used. The poplar was knife milled and passed through a 1 mm sieve and CELF pretreatment was performed in a Parr autoclave reactor with 7.5 wt % solids loading, 0.5 wt% H2SO4 as catalyst at 150°C with various time. Tetrahydrofuran was added in a 1:1 mass ratio with water as the pretreatment solvent. Lignin was isolated from the pretreated samples after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 580 rpm for 2.5 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The solid residue was isolated by centrifugation and hydrolyzed again with freshly added buffer and enzymes for another 48 h. After filtration, the solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The lignin samples were then derivatized in an acetic anhydride/pyridine (1:1, v/v) mixture and stirred at room temperature for 24 h. Ethanol was added to the reaction mixture, left for 30 min and then removed with a rotary evaporator. The addition and removal of ethanol was repeated at least 3 times until all traces of acetic acid were removed. Acetylated lignin samples were then dissolved in tetrahydrofuran (THF) at a concentration of 1.0 mg/mL. The molecular weight of acetylated lignin was measured by a gel permeation chromatography (GPC) on a PSS-Polymer Standards Service (Warwick, RI, USA) GPC SECurity 1200 system featuring Agilent HPLC 1200 components equipped with four Waters Styragel columns (HR1, HR2, HR4 and HR6) and an UV detector (270 nm). Tetrahydrofuran was used as the mobile phase and flow rate was 0.3 mL/min. The Polymer Standards Service WinGPC Unity software (Build 6807) was used for data processing for all the samples. The data provides information about the effects of CELF pretreatment time at 150 ºC on lignin molecular weights.

09 BIOMASS FUELS↗

PET imaging predicts future body weight and cocaine preference

Deficits in dopamine D2/D3 receptor (D2R/D3R) binding availability using PET imaging have been reported in obese humans and rodents. Similar deficits have been reported in cocaine-addicts and cocaine-exposed primates. We found that D2R/D3R binding availability negatively correlated with measures of body weight at the time of scan (ventral striatum), at 1 (ventral striatum) and 2 months (dorsal and ventral striatum) post scan in rats. Cocaine preference was negatively correlated with D2R/D3R binding availability 2 months (ventral striatum) post scan. Our findings suggest that inherent deficits in striatal D2R/D3R signaling are related to obesity and drug addiction susceptibility and that ventral and dorsal striatum serve dissociable roles in maintaining weight gain and cocaine preference. Measuring D2R/D3R binding availability provides a way for assessing susceptibility to weight gain and cocaine abuse in rodents and given the translational nature of PET imaging, potentially primates and humans.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Higher Molecular Weight Leads to Improved Photoresponsivity Charge Transport and Interfacial Ordering in a Narrow Bandgap Semiconducting Polymer

Increasing the molecular weight of the low-bandgap semiconducting copolymer, poly[(4,4-didoecyldithieno[3,2-b:2',3'-d]silole)-2,6-diyl-alt-(2,1,3-benzothiadiazole)-4,7-diyl], Si-PDTBT, from 9 kDa to 38 kDa improves both photoresponsivity and charge transport properties dramatically. The photocurrent measured under steady state conditions is 20 times larger in the higher molecular weight polymer (HM{sub n} Si-PDTBT). Different decays of polarization memory in transient photoinduced spectroscopy measurements are consistent with more mobile photoexcitations in HM{sub n} Si-PDTBT relative to the lower molecular weight counterpart (LM{sub n} Si-PDTBT). Analysis of the current-voltage characteristics of field effect transistors reveals an increase in the mobility by a factor of 700 for HM{sub n} Si-PDTBT. Near edge X-ray absorption fine structure (NEXAFS) spectroscopy and grazing incidence small angle X-ray scattering (GISAXS) measurements demonstrate that LM{sub n} Si-PDTBT forms a disordered morphology throughout the depth of the film, whereas HM{sub n} Si-PDTBT exhibits pronounced {pi}-{pi} stacking in an edge-on configuration near the substrate interface. Increased interchain overlap between polymers in the edge-on configuration in HM{sub n} Si-PDTBT results in the higher carrier mobility. The improved optical response, transport mobility, and interfacial ordering highlight the subtle role that the degree of polymerization plays on the optoelectronic properties of conjugated polymer based organic semiconductors.

36 MATERIALS SCIENCE↗

Authentication and Interpretation of Weight Data Collected from Accountability Scales at Global Nuclear Fuels

Accountability scale data from the Global Nuclear Fuels (GNF) fuel fabrication facility in Wilmington, NC has been collected and analyzed as a part of the Cylinder Accountability and Tracking System (CATS) field trial in 2009. The purpose of the data collection was to demonstrate an authentication method for safeguards applications, and the use of load cell data in cylinder accountability. The scale data was acquired using a commercial off-the-shelf communication server with authentication and encryption capabilities. The authenticated weight data was then analyzed to determine facility operating activities. The data allowed for the determination of the number of full and empty cylinders weighed and the respective weights along with other operational activities. Data authentication concepts, practices and methods, the details of the GNF weight data authentication implementation and scale data interpretation results will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Chlorinated Donor Polymer Achieving High‐Performance Organic Solar Cells with a Wide Range of Polymer Molecular Weight

Abstract In the field of non‐fullerene organic solar cells (OSCs), compared to the rapid development of non‐fullerene acceptors, the progress of high‐performance donor polymers is relatively slow. The property and performance of donor polymers in OSCs are often sensitive to the molecular weight of the polymers. In this study, a chlorinated donor polymer named D18‐Cl is reported, which can achieve high performance with a wide range of polymer molecular weight. The devices based on D18‐Cl show a higher open‐circuit voltage ( V OC ) due to the slightly deeper energy levels and an outstanding short‐circuit current density ( J SC ) owing to the appropriate long periods of blend films and less ([6,6]‐phenyl‐C71‐butyric acid methyl ester) (PC 71 BM) in mixed domains, leading to the higher efficiency of 17.97% than those of the D18‐based devices (17.21%). Meanwhile, D18‐Cl can achieve high efficiencies (17.30–17.97%) when its number‐averaged molecular weight ( M n ) is ranged from 45 to 72 kDa. In contrast, the D18‐based devices only exhibit relatively high efficiencies in a narrow M n range of ≈70 kDa. Such property and performance make D18‐Cl a promising donor polymer for scale‐up and low‐cost production.

Zeng, Anping↗

Tailoring Binder Molecular Weight to Enhance Slurry-Cast NMC Cathodes for Sulfide Solid-State Batteries

We demonstrate for the first time the critical influence of binder molecular weight on the performance of slurry-cast lithium nickel manganese cobalt oxide (NMC) cathodes in sulfide-based all-solid-state batteries (SSBs). SSBs are increasingly recognized as a safer and potentially more efficient alternative to traditional Li-ion batteries, owing to the superior ionic conductivities and inherent safety features of sulfide solid electrolytes. However, the integration of high-voltage NMC cathodes with sheet-type sulfide solid electrolytes presents significant fabrication challenges. Our findings reveal that higher molecular weight binders not only enhance the discharge capacity and cycle life of these cathodes but also ensure robust adhesion and structural integrity. By optimizing binder molecular weights, we effectively shield the active materials from degradation and mechanical stress, significantly boosting the functionality and longevity of SSBs. These results underscore the paramount importance of binder properties in advancing the practical application of high-performance all-solid-state batteries.

25 ENERGY STORAGE↗

Studies of transverse momentum dependent parton distributions and Bessel weighting

In this paper we present a new technique for analysis of transverse momentum dependent parton distribution functions, based on the Bessel weighting formalism. The procedure is applied to studies of the double longitudinal spin asymmetry in semi-inclusive deep inelastic scattering using a new dedicated Monte Carlo generator which includes quark intrinsic transverse momentum within the generalized parton model. Using a fully differential cross section for the process, the effect of four momentum conservation is analyzed using various input models for transverse momentum distributions and fragmentation functions. We observe a few percent systematic offset of the Bessel-weighted asymmetry obtained from Monte Carlo extraction compared to input model calculations, which is due to the limitations imposed by the energy and momentum conservation at the given energy/Q 2 . We find that the Bessel weighting technique provides a powerful and reliable tool to study the Fourier transform of TMDs with controlled systematics due to experimental acceptances and resolutions with different TMD model inputs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters

Purpose: We evaluate the reliability and feasibility of weight-adapted ultra-low-dose pancreatic perfusion CT. Methods: A total of 100 (47 men, 53 women) patients were enrolled prospectively and were assigned to five groups (A, B, C, D, and E) with different combination of tube voltage and tube current according to their body weight. Radiation dose parameters including volume CT dose index (CTDI) and dose-length product (DLP) were recorded. Image quality was evaluated both subjectively and objectively (noise, signal-to-noise ratio, contrast-to-noise ratio). Perfusion parameters including blood flow (BF), blood volume (BV), and permeability (PMB) were measured. The dose, image quality measurements, and perfusion parameters were compared between the five groups using one-way analysis of variance (ANOVA). Results: Radiation dose reached 8.7 mSv in patients under 50 kg and was 18.9 mSv in patients above 80 kg. The mean subjective image quality score was above 4.45 on a 5-point scale with good agreement between two radiologists. Groups A–D had equivalent performance on objective image quality (P > 0.05), while Group E performed even better (P < 0.05). No significant differences emerged in comparison with perfusion parameters (BF, BV, PMB) of normal pancreas parenchyma between the five groups. Conclusion: Weight-adapted ultra-low-dose pancreatic perfusion CT can effectively reduce radiation dose without prejudice to image quality, and the perfusion parameters of normal parenchyma are accurate and reliable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Locally advanced rectal cancer: qualitative and quantitative evaluation of diffusion-weighted magnetic resonance imaging in restaging after neoadjuvant chemo-radiotherapy

Purpose: To determine the added value of qualitative and quantitative evaluation of diffusion-weighted magnetic resonance imaging (DWI) in locally advanced rectal cancer (LARC) restaging after neoadjuvant chemo-radiotherapy (CRT). Materials and Methods: A retrospective study was performed of 21 patients with LARC treated with CRT. All patients were evaluated with 1.5 T conventional magnetic resonance imaging (MRI) and DWI (0–1000 s/mm²) before starting therapy and after neoadjuvant CRT. All included patients underwent surgery after CRT: the histopathological evaluation of surgical specimens represented the reference standard for local staging after neoadjuvant therapy. The qualitative analysis was carried out by two operators in consensus, who reviewed the conventional MR image set [T1-weighted and T2-weighted morphological sequences + dynamic contrast-enhanced sequences (DCE)] and the combined set of conventional and DW images. For the quantitative analysis, the apparent diffusion coefficient (ADC) values were measured at each examination. For each lesion, the mean ADC value (ADCpre and ADCpost) and the ΔADC (ADCpost – ADCpre) were calculated, and values of the three groups of response [complete response (pCR), partial response (pPR), stable disease (pSD)] were compared. Results: In LARC restaging, conventional MRI showed a sensitivity of 80% and a specificity of 50%, with a total diagnostic capacity of 71.40%, while by adding DWI sensitivity increased to 100%, specificity to 67%, and total diagnostic capacity to 90.40%. ΔADC correlates with treatment response and a cutoff of 1.35 × 10{sup −3} mm²/s predicts the pCR with a sensitivity of 93.3% and a specificity of 83.3%. Conclusions: Adding DWI to conventional sequences may improve MRI capability to evaluate tumor response to CRT. The quantitative DWI assessment is promising, but larger studies are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generators for Spaces of Entire Functions with a System of Weighted Estimates

We consider spaces of entire functions with systems of weighted estimates. The case of twoterm weight sequences consisting of radial and nonradial components is studied. Under some assumptions on the weight sequence, we obtain a complete description of generators in these spaces. We apply this result to the problem of normal solvability of systems of convolution equations in the Roumieu spaces of ultradifferentiable functions and, as a particular case, in Gevrey classes.

97 MATHEMATICS AND COMPUTING↗

Effects of n-3PUFAs on autophagy and inflammation of hypothalamus and body weight in mice

Highlights: • The effect of fat-1 gene on body weight is achieved via regulating expression of inflammatory and autophagy in hypothalamus. • The body weight, body and the Lee’s index are decreased in fat-1 transgenic mice. • The autophagy increased and the inflammation decreased in hypothalamus of fat-1 transgenic mice. Fat-1 transgenic mice were used as a model to study the effect of endogenous n-3 polyunsaturated fatty acids (n-3PUFAs) on the body weight, inflammatory factors and autophagy proteins in hypothalamus to explore the mechanism of n-3PUFAs inhibiting obesity.

60 APPLIED LIFE SCIENCES↗

Compound D159687, a phosphodiesterase 4D inhibitor, induces weight and fat mass loss in aged mice without changing lean mass, physical and cognitive function

Highlights: • Seven weeks of Compound D159687 (D159687) induces weight loss in aged mice. • D159687 causes a selective loss of fat mass while preserving lean mass. • The weight loss in D159687 treated mice occurred despite increased food intake. Therapies that recapitulate the health benefits of caloric restriction in older adults are needed. Phosphodiesterase 4 inhibitors demonstrate such promise. We examined their effects on body weight and composition, physical and cognitive function in aged mice using Compound D159687 (D159687).

60 APPLIED LIFE SCIENCES↗

Weighted nodal domain averages of eigenstates for quantum Monte Carlo and beyond

In this report we study the nodal properties of many-body eigenstates of stationary Schrödinger equation that affect the accuracy of real-space quantum Monte Carlo calculations. In particular, we introduce weighted nodal domain averages that provide a new probe of nodal surfaces beyond the usual expectations. Particular choices for the weight function reveal, for example, that the difference between two arbitrary fermionic eigenvalues is given by the nodal hypersurface integrals normalized by overlaps with the bosonic ground state of the given Hamiltonian. Noninteracting and fully interacting Be atom with corresponding almost exact and approximate wave functions are used to illustrate several aspects of these concepts. Variational formulations that employ different weights are proposed for prospective improvement of nodes in variational and fixed-node diffusion Monte Carlo calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Weight Gain in Advanced Non-Small-Cell Lung Cancer Patients During Treatment With Split-Course Concurrent Chemoradiotherapy Is Associated With Superior Survival

Background: Preoperative concurrent chemoradiotherapy (CRT) is an accepted treatment for potentially resectable, locally advanced, non-small-cell lung cancer (NSCLC). We reviewed a decade of single institution experience with preoperative split-course CRT followed by surgical resection to evaluate survival and identify factors that may be helpful in predicting outcome. Methods and Materials: All patients treated with preoperative split-course CRT and resection at Rush University Medical Center (RUMC) between January 1999 and December 2008 were retrospectively analyzed. Endpoints included overall survival (OS), progression-free survival (PFS), local-regional progression-free survival (LRPFS), and distant metastasis-free survival (DMFS). Patient and treatment related variables were assessed for correlation with outcomes. Results: A total of 54 patients were analyzed, 76% Stage IIIA, 18% Stage IIIB, and 6% oligometastatic. The pathologic complete response (pCR) rate was 31.5%, and the absence of nodal metastases (pN0) was 64.8%. Median OS and 3-year actuarial survival were 44.6 months and 50%, respectively. Univariate analysis revealed initial stage (p < 0.01) and percent weight change during CRT (p < 0.01) significantly correlated with PFS/OS. On multivariate analysis initial stage (HR, 2.4; 95% CI, 1.18-4.90; p = 0.02) and percent weight change (HR, 0.79; 95% CI, 0.67-0.93; p < 0.01) maintained significance with respect to OS. There were no cases of Grade 3+ esophagitis, and there was a single case of Grade 3 febrile neutropenia. Conclusions: The strong correlation between weight change during CRT and OS/PFS suggests that this clinical parameter may be useful as a complementary source of predictive information in addition to accepted factors such as pathological response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-Weighted Magnetic Resonance Imaging Early After Chemoradiotherapy to Monitor Treatment Response in Head-and-Neck Squamous Cell Carcinoma

Purpose: To evaluate diffusion-weighted imaging (DWI) for assessment of treatment response in head and neck squamous cell carcinoma (HNSCC) three weeks after the end of chemoradiotherapy (CRT). Methods and Materials: Twenty-nine patients with HNSCC underwent magnetic resonance imaging (MRI) prior to and 3 weeks after CRT, including T{sub 2}-weighted and pre- and postcontrast T{sub 1}-weighted sequences and an echo-planar DWI sequence with six b values (0 to 1,000 s/mm{sup 2}), from which the apparent diffusion coefficient (ADC) was calculated. ADC changes 3 weeks posttreatment compared to baseline ( Increment ADC) between responding and nonresponding primary lesions and adenopathies were correlated with 2 years locoregional control and compared with a Mann-Whitney test. In a blinded manner, the Increment ADC was compared to conventional MRI 3 weeks post-CRT and the routinely implemented CT, on average 3 months post-CRT, which used size-related and morphological criteria. Positive and negative predictive values (PPV and NPV, respectively) were compared between the Increment ADC and anatomical imaging. Results: The Increment ADC of lesions with later tumor recurrence was significantly lower than lesions with complete remission for both primary lesions (-2.3% {+-} 0.3% vs. 80% {+-} 41%; p < 0.0001) and adenopathies (19.9% {+-} 32% vs. 63% {+-} 36%; p = 0.003). The Increment ADC showed a PPV of 89% and an NPV of 100% for primary lesions and a PPV of 70% and an NPV of 96% for adenopathies per neck side. DWI improved PPV and NPV compared to anatomical imaging. Conclusion: DWI with the Increment ADC 3 weeks after concluding CRT for HNSCC allows for early assessment of treatment response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-Weighted Magnetic Resonance Imaging in Monitoring Rectal Cancer Response to Neoadjuvant Chemoradiotherapy

Purpose: To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. Methods and Materials: The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T{sub 2}- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm{sup 2}/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examined the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Results: Low pretreatment ADCs (<1.0 Multiplication-Sign 10{sup -3}mm{sup 2}/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC {>=}1.4 Multiplication-Sign 10{sup -3}mm{sup 2}/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Conclusion: Diffusion-weighted magnetic resonance imaging seems to be a promising tool for monitoring the response to CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A weighted ℓ{sub 1}-minimization approach for sparse polynomial chaos expansions

This work proposes a method for sparse polynomial chaos (PC) approximation of high-dimensional stochastic functions based on non-adapted random sampling. We modify the standard ℓ{sub 1}-minimization algorithm, originally proposed in the context of compressive sampling, using a priori information about the decay of the PC coefficients, when available, and refer to the resulting algorithm as weightedℓ{sub 1}-minimization. We provide conditions under which we may guarantee recovery using this weighted scheme. Numerical tests are used to compare the weighted and non-weighted methods for the recovery of solutions to two differential equations with high-dimensional random inputs: a boundary value problem with a random elliptic operator and a 2-D thermally driven cavity flow with random boundary condition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗