Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Electrorefining Bismuth Using AC Superimposed DC Waveforms

Bismuth has been successfully electrorefined using both direct current (DC) and alternating current (AC) superimposed DC waveforms on a kilogram scale at Brigham Young University (BYU) in Provo, Utah. Finding a suitable surrogate for Pu Electrorefining has always been a technical challenge. This work allows the possibility to improve Pu electrorefining with nonradioactive material at universities, which greatly reduces the cost at Lawrence Livermore National Laboratory (LLNL) for improving Pu Electrorefining. Several possible surrogates (Ce, In, Sn, Zn, and Bi) were selected based on their ability to mimic the Pu electrorefining process. Ce and In electrorefining experiments were conducted at the same temperature as Pu electrorefining in CaCl 2 while Sn, Zn, and Bi, electrorefining experiments were conducted at a lower temperature in a eutectic molten salt composed of LiCl, KCl, and CaCl 2 . The electrorefining experiments using Ce with a Ga impurity did not produce a cathode ring. While the remaining Ce anode after electrorefining was significantly less than what was initially added, Scanning Electron Microscopy with Energy Dispersive X-Ray (SEM-EDX) analysis showed that the Ce had been oxidized and formed a colloid with the surrounding molten salt. This is supported in the literature by analysis of Ce-rich CaCl 2 mixtures. All the electrorefining experiments except for the Ce electrorefining experiments did not introduce an impurity to the system. Electrorefining experiments with In showed that the InCl 3 volatilized out of the molten salt to an extent that only a low current (<<1 A) could be supported without decomposing the molten salt. Zn electrorefining experiments had marginal success, however an easily separable product was not formed. The Zn had to be rinsed from the salt after the experiment. Of the identified potential surrogates. Investigated, only Bi and Sn yielded an easily separable product ring, which enables quantitative analysis of yields and coulombic efficiencies. Bismuth was first identified as a surrogate at BYU, while Sn was identified as a surrogate at LLNL later. Thus, the electrorefining experiments conducted at BYU using AC superimposed DC waveforms used Bi as the metal to be electrorefined.

36 MATERIALS SCIENCE↗

AC resistance measurement of Skew Quadrupole Magnet

This tech note exhibits AC resistance measurement system of the Skew Quadrupole magnet with and without a beam pipe used in the AGS ring. The measurement results are compared with a system that uses skew quad power supply for the magnet. An introduction to ac resistance conceptualization and modeling is presented. It is followed by measurement methodology used and the results.

43 PARTICLE ACCELERATORS↗

Ferrites Analysis for the AC-Dipole

In this article, it’s presented the AC-Dipole magnet structure and a method to measure and model bricks of ferrite. These are the building blocks of the magnet. Aim of the project is obtaining a model of the magnetic permeability of the chosen material to get satisfying simulation of the AC-Dipole magnet’s behavior and to size power supply and cooling system.

43 PARTICLE ACCELERATORS↗

Optimal Power Dispatch of DGs in Radial and Mesh AC Grids: A Hybrid Solution Methodology between the Salps Swarm Algorithm and Successive Approximation Power Flow Method

In this paper, we address the problem of the optimal power dispatch of Distributed Generators (DGs) in Alternating Current (AC) networks, better known as the Optimal Power Flow (OPF) problem. We used, as the objective function, the minimization of power losses (P loss ) associated with energy transport, which are subject to the set of constraints that compose AC networks in an environment of distributed generation. To validate the effectiveness of the proposed methodology in solving the OPF problem in any network topology, we employed one 10-node mesh test system and three radial text systems: 10, 33, and 69 nodes. In each test system, DGs were allowed to inject 20%, 40%, and 60% of the power supplied by the slack generator in the base case. To solve the OPF problem, we used a master–slave methodology that integrates the optimization method Salps Swarm Algorithm (SSA) and the load flow technique based on the Successive Approximation (SA) method. Moreover, for comparison purposes, we employed some of the algorithms reported in the specialized literature to solve the OPF problem (the continuous genetic algorithm, the particle swarm optimization algorithm, the black hole algorithm, the antlion optimization algorithm, and the Multi-Verse Optimizer algorithm), which were selected because of their excellent results in solving such problems. The results obtained by the proposed solution methodology demonstrate its superiority and convergence capacity in terms of minimization of P loss in both radial and mesh systems. It provided the best reduction in minimum P loss in short processing times and showed excellent repeatability in each test system and scenario under analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prognostic simulations of mixed-phase clouds with model AC-1D v1.0: the impact of aerosol types and freezing parameterizations on ice crystal budgets

Mixed-phase clouds at high latitudes contribute to the uncertainty in predicting cloud feedbacks and climate sensitivity, mainly due to the complexity of microphysical processes that influence the partitioning between the supercooled liquid and ice phases, and hence, cloud radiative effects on regional scales. Particularly in Arctic mixed-phase clouds, the activation of ice-nucleating particles (INPs) from various aerosol populations remains a leading source of uncertainty. We developed an aerosol-cloud one-dimensional (AC-1D) model, which provides a novel framework to prognostically treat INP and ice crystal budgets while explicitly accounting for polydisperse and multicomponent aerosol that activate INPs following different freezing parameterizations. The AC-1D model is informed by large-eddy simulations to probe the impact of INP representation on predicted ice crystal number concentrations (N i ) and ice crystal budgets in mixed-phase Arctic stratus. We apply three immersion freezing (IMF) parameterizations, two time-independent (singular) and one time-dependent (classical nucleation theory), to predict the evolution of the INP reservoir and resulting ice crystal budget from polydisperse mineral dust, organic (humic-like substances), and sea spray aerosol particle size distributions. Our analysis focuses on how variations in aerosol number concentration and cloud system parameters such as cloud cooling rate, cloud-top entrainment rate, and ice crystal fall speed influence the INP reservoir and ice crystal budgets. Furthermore, this study investigates the competitive ice nucleation dynamics in mixed aerosol environments and provides a process-level quantification of the INP budget terms, which directly controls ice crystal budgets. For all studied case scenarios, the aerosol types and associated particle size distributions significantly impact INP and N i , and the choice between a time-dependent and a singular freezing description yields orders-of-magnitude differences in the predicted INP and N i over the 10 h simulation time, reflecting typical cloud lifetimes. Our results show that the influence of cloud cooling, INP entrainment, and sedimentation varies significantly depending on the chosen freezing parameterization. These findings underscore the critical need for robust IMF parameterizations and precise cloud system observations to enhance the accuracy of models in predicting mixed-phase cloud structure and evolution.

Arctic clouds↗

Solid-state ac-to-dc converter

Converter uses solid-state ac-to-dc rectification circuitry, filter circuitry, a tuned transformer, ac chopper circuitry, and an automatic current-control network. It has a dc power source which operates from 5 to 100 percent load at a 72 to 94 input to output efficiency.

Monroe, C. M.↗

Thermionic triode generates ac power

Electrostatic grid controls conduction cycle of thermionic diode to convert low dc output voltages to high ac power without undesirable power loss. An ac voltage applied to the grid of this new thermionic triode enables it to convert heat directly into high voltage electrical power.

Kniazzeh, A. G. F.↗

Postflight Evaluation of Atlas-Centaur AC-6 (Launched August 11, 1965)

The sixth Atlas Centaur vehicle (AC-6) was successfully launched from the Eastern T e s t Range, Complex 36B, on August 11, 1965, at 0931:04.430 EST. A 2084-pound dynamic model of the Surveyor payload was placed in a simulated lunar transfer trajectory. Vehicle systems operated satisfactorily and all the flight objectives were accomplished. Lift-off within 4 seconds of the window opening demonstrated the launch-on-time capability of the vehicle were accurately compensated for by the Centaur guidance system. the Surveyor model into a near-perfect lunar transfer trajectory would have resulted in an impact of the moon without a midcourse correction. To hit the precise target area on the lunar surface, the required correction would have been 4.25 meters per second, which is well within the spacecraft capability. Normal thrust and impulse levels were obtained with both the A t l a s and Centaur propulsion systems. However, a sizeable thrust overshoot on startup of the Centaur engines has not been resolved. A propellant-utilization system used for the first time on the Centaur, accurately controlled the fuel and oxidant consumption. The turnaround and retrothrust maneuver were performed without incident. Relatively high longitudinal modal excitations and lateral payload excitations were obtained at lift-off; these high perturbations are believed t o be related t o the launcher holddown arms. Nominal temperatures were recorded for both the external vehicle skin and the payload compartment; however, abnormally low temperatures were measured in the forward equipment area, which may have resulted from leakage of cold helium purge gas. All vehicle electrical systems performed satisfactorily; the only difficulty with the RF systems was obtained with the C-band transponder. of the vehicle instrumentation yielded valid data. The AC-6 vehicle was constructed with several new lightweight designs including the forward bulkhead, thrust barrel, interstage adapter and tank skin thickness reduction from 0.016 t o 0.014 inch. No deficiencies were observed in any of these new structural elements.

Source record↗

Measured losses in superconductor magnets for 60-Hertz ac operation.

Results of an experimental study of electrical losses in superconductor magnets. Preliminary 60-Hz ac loss data are presented for coils constructed of Nb3Sn ribbon, Nb-Ti cable, and multifilament Nb-Ti. Losses have been measured for different size coils up to approximately 20 cm in diameter. Of the conductor types tested, Nb3Sn ribbon has the lowest losses for ac operation. In Nb3Sn-ribbon coils of different sizes, the loss per unit length of conductor is shown to decrease with a decrease in the rate of change of current and to increase, in general, with increase in coil size. An important aspect of the study is the high degree of repeatability of the data.

Hamlet, I. L.↗

Variable-frequency inverter controls torque, speed, and braking in ac induction motors

Dc to ac inverter provides optimum frequency and voltage to ac induction motor, in response to different motor-load and speed requirements. Inverter varies slip frequency of motor in proportion to required torque. Inverter protects motor from high current surges, controls negative slip to apply braking, and returns energy stored in momentum of load to dc power source.

Nola, F. J.↗

Phase protection system for ac power lines

The system described provides protection for phase sensitive loads from being or remaining connected to ac power lines whenever a phase reversal occurs. It comprises a solid state phase detection circuit, a dc power relay circuit, an ac-to-dc converter for energizing the relay circuit, and a bistable four terminal transducer coupled between the phase detection circuit and the power relay circuit, for controlling both circuits.

Wong, W. J.↗

Postflight Evaluation of Atlas-Centaur AC-5 (Launched 2 March 1965)

The Atlas-Centaur AC-5 vehicle was launched from ETR Complex 36A on March 2., 1965 at 8:25.04 a.m. EST. Within about 1 second after launch the thrust of the Atlas booster engine decayed rapidly; the vehicle settled back on the launch pad and was quickly destroyed by fire and explosion. Considerable damage was sustained by the launch complex and its associated equipment. Loss of booster engine thrust was due to fuel depletion at the turbopump inlets, which is attributed to closure of the fuel prevalve or the staging valve. To preclude the recurrence of either of these fuel valving malfunctions, the following corrective action has been taken: The remote control actuator has been replaced by manual operation of the Atlas fuel prevalve; the internal passage dimensions in the staging valve have been increased to lessen the hydraulic load on the valve poppet. In addition to the Atlas fuel system malfunction, a failure in the power control circuitry of the Centaur guidance computer resulted in partial removal of power at umbilical ejection. To prevent such a guidance system failure on future flights some redundant circuitry has been eliminated and more rigorous checkout procedures have been adopted. No further anomalies were discovered in the telemetered data prior to the Atlas booster thrust decay. A prime objective of the AC-5 flight was to place a dynamic model of the Surveyor spacecraft in a simulated lunar transfer trajectory. An important facet of this problem is the demonstration of a launch-on-time capability in accordance with the proper Earth-moon relation. The window opening time was established at 8:25 a.m. EST; thus the actual launch occurred within 4 seconds of the planned time.

Source record↗

Direct-current drive for ac motors

Dual windings of ac motor serve as output transformer for dc/ac inversion. Method makes use of low-cost commutatorless ac motors, powered by solar energy, batteries and other dc sources possible.

Solario, J. N.↗

Data pattern sensitivity in tracking performance of an AC coupled Costas loop with hard-limited in-phase channel

This paper is concerned with data pattern sensitivity in carrier tracking performance of an AC coupled Costas loop with a suppressed BPSK signal. The signal amplitude suppression factor is derived as a function of data 'asymmetry ratio' - the ratio of '1's to the total number of bits in a period of a periodic signal. For an asymmetric pattern, the effect of AC coupling is noticeable whereas there is almost no effect for symmetric square wave. The tracking performance with an asymmetric pattern is worse than that with a symmetric pattern. However, it is also shown that as expected, the tracking performance of a DC coupled loop with an asymmetric pattern is better than that with a symmetric pattern.

Park, Y. H.↗

The ac propulsion system for an electric vehicle, phase 1

A functional prototype of an electric vehicle ac propulsion system was built consisting of a 18.65 kW rated ac induction traction motor, pulse width modulated (PWM) transistorized inverter, two speed mechanically shifted automatic transmission, and an overall drive/vehicle controller. Design developmental steps, and test results of individual components and the complex system on an instrumented test frame are described. Computer models were developed for the inverter, motor and a representative vehicle. A preliminary reliability model and failure modes effects analysis are given.

Geppert, S.↗

Progress on advanced dc and ac induction drives for electric vehicles

Progress is reported in the development of complete electric vehicle propulsion systems, and the results of tests on the Road Load Simulator of two such systems representative of advanced dc and ac drive technology are presented. One is the system used in the DOE's ETV-1 integrated test vehicle which consists of a shunt wound dc traction motor under microprocessor control using a transistorized controller. The motor drives the vehicle through a fixed ratio transmission. The second system uses an ac induction motor controlled by transistorized pulse width modulated inverter which drives through a two speed automatically shifted transmission. The inverter and transmission both operate under the control of a microprocessor. The characteristics of these systems are also compared with the propulsion system technology available in vehicles being manufactured at the inception of the DOE program and with an advanced, highly integrated propulsion system upon which technology development was recently initiated.

Schwartz, H. J.↗