Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Accuracy and stability in incompressible SPH (ISPH) based on the projection method and a new approach

The stability and accuracy of three methods which enforce either a divergence-free velocity field, density invariance, or their combination are tested here through the standard Taylor-Green and spin-down vortex problems. While various approaches to incompressible SPH (ISPH) have been proposed in the past decade, the present paper is restricted to the projection method for the pressure and velocity coupling. It is shown that the divergence-free ISPH method cannot maintain stability in certain situations although it is accurate before instability sets in. The density-invariant ISPH method is stable but inaccurate with random-noise like disturbances. The combined ISPH, combining advantages in divergence-free ISPH and density-invariant ISPH, can maintain accuracy and stability although at a higher computational cost. Redistribution of particles on a fixed uniform mesh is also shown to be effective but the attraction of a mesh-free method is lost. A new divergence-free ISPH approach is proposed here which maintains accuracy and stability while remaining mesh free without increasing computational cost by slightly shifting particles away from streamlines, although the necessary interpolation of hydrodynamic characteristics means the formulation ceases to be strictly conservative. This avoids the highly anisotropic particle spacing which eventually triggers instability. Importantly pressure fields are free from spurious oscillations, up to the highest Reynolds numbers tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy Based Generation of Thermodynamic Properties for Light Water in RELAP5-3D

RELAP5-3D interpolates to obtain thermodynamic properties for use in its internal calculations. The accuracy of the interpolation was determined for the original steam tables currently used by the code. This accuracy evaluation showed that the original steam tables are generally detailed enough to allow reasonably accurate interpolations in most areas needed for typical analyses of nuclear reactors cooled by light water. However, there were some regions in which the original steam tables were judged to not provide acceptable accurate results. Revised steam tables were created that used a finer thermodynamic mesh between 4 and 21 MPa and 530 and 640 K. The revised steam tables solved most of the problems observed with the original steam tables. The accuracies of the original and revised steam tables were compared throughout the thermodynamic grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

Maintaining Trust in Reduction: Preserving the Accuracy of Quantities of Interest for Lossy Compression

As the growth of data sizes continues to outpace computational resources, there is a pressing need for data reduction techniques that can significantly reduce the amount of data and quantify the error incurred in compression. Compressing scientific data presents many challenges for reduction techniques since it is often on non-uniform or unstructured meshes, is from a high-dimensional space, and has many Quantities of Interests (QoIs) that need to be preserved. To illustrate these challenges, we focus on data from a large scale fusion code, XGC. XGC uses a Particle-In-Cell (PIC) technique which generates hundreds of PetaBytes (PBs) of data a day, from thousands of timesteps. XGC uses an unstructured mesh, and needs to compute many QoIs from the raw data, f.One critical aspect of the reduction is that we need to ensure that QoIs derived from the data (density, temperature, flux surface averaged momentums, etc.) maintain a relative high accuracy. We show that by compressing XGC data on the high-dimensional, nonuniform grid on which the data is defined, and adaptively quantizing the decomposed coefficients based on the characteristics of the QoIs, the compression ratios at various error tolerances obtained using a multilevel compressor (MGARD) increases more than ten times. We then present how to mathematically guarantee that the accuracy of the QoIs computed from the reduced f is preserved during the compression. We show that the error in the XGC density can be kept under a user-specified tolerance over 1000 timesteps of simulation using the mathematical QoI error control theory of MGARD, whereas traditional error control on the data to be reduced does not guarantee the accuracy of the QoIs.

Gong, Qian↗

Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency

ObjectivesTo compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference.MethodsForty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard.ResultsBoth readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5′45″ based on mpCPRs vs. 7′40″ based on axial images; Reader 2: 4′41″ based on mpCPRs vs. 6′57″ based on axial images; p < 0.01).ConclusionsmpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Study of Layer Heating and Continuous Heating Methods on Prediction Accuracy of Residual Stresses in Selective Laser Melted Tube Samples

Thermal distortion and residual stresses are two important factors that affect the quality and reliability of steel parts manufactured by laser powder bed fusion (LPBF) processes. A cost-effective model for evaluation of those heat effects is needed to refine the manufacturing process and provides insights into the product design and heat treatment. In this study, the layer heating method and sophisticated track-layer scanning method were applied to simulate the thermo-mechanical response of IN625 tube parts built by LPBF. Based on the similarity of temperature field in each layer deposit, a swept mesh was constructed to perform the thermal analysis for top layer, with the rest of layers referring to the temperature by node number offsetting. A novel explicit finite element analysis code accelerated by graphics processing unit was used for the massive-element numerical analysis. The computational accuracy and efficiency of the layer heating and track-layer scanning methods were compared in detail. It is shown that layer heating method can efficiently capture the pattern of stress distribution with reasonable accuracy in stress magnitude. The grouped track-layer scanning method can predict the residual stress and strain more accurately at a higher cost (5 ~ 10×). The elastic strain distribution was compared with the measurement by X-ray diffraction, confirming the accuracy of residual stress prediction.

36 MATERIALS SCIENCE↗

Accuracy of predictions made by machine learned models for biocrude yields obtained from hydrothermal liquefaction of organic wastes

Hydrothermal liquefaction (HTL) has potential for converting abundant wet organic wastes into renewable fuels. Because HTL consists of a complex reaction network, deterministic, physics-based prediction of its biocrude yield is prohibitively difficult. Data-driven methods provide an alternative to the physics-based approach; however, rigorous testing must be performed to ensure the accuracy of predictions made by data-driven methods. To this end, a data set was assembled consisting of 570 data points appearing in the open literature. The data set was divided into training, validation, and test sub-sets and used for evaluating different machine learning regression approaches to predict biocrude yield. Among the tested algorithms, Random Forest and eXtreme Gradient Boosting (XGBoost) predicted biocrude yields in a test set that had not been used for training with the greatest accuracy, with root mean square errors (RMSE) of 8.34 and 8.57, respectively. Further refinement of the Random Forest model reduced its RMSE to 8.07. In comparison, predictions of a series of literature models resulted in RMSE ranging from 9.16 in the most accurate case to 27.6 in the least accurate; most literature models yielded RMSE values > 10. Using biocrude yield predictions from the most accurate Random Forest model and a probabilistic economic analysis found that the model accuracy is sufficient to prioritize allocation of resources based on projected minimum fuel selling price. In our report the models and analysis represent a major advance in the ability to use readily available data to predict biocrude yields on new feedstocks that have not previously been studied.

42 ENGINEERING↗

Development and application of a statistical methodology to evaluate the predictive accuracy of building energy baseline models

This paper documents the development and application of a general statistical methodology to assess the accuracy of baseline energy models, focusing on its application to Measurement and Verification (M&V) of whole-­building energy savings. The methodology complements the principles addressed in resources such as ASHRAE Guideline 14 and the International Performance Measurement and Verification Protocol. It requires fitting a baseline model to data from a ``training period’’ and using the model to predict total electricity consumption during a subsequent ``prediction period.’’ We illustrate the methodology by evaluating five baseline models using data from 29 buildings. The training period and prediction period were varied, and model predictions of daily, weekly, and monthly energy consumption were compared to meter data to determine model accuracy. Several metrics were used to characterize the accuracy of the predictions, and in some cases the best-­performing model as judged by one metric was not the best performer when judged by another metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Reported Outcomes After Radiation Therapy in Men With Prostate Cancer: A Systematic Review of Prognostic Tool Accuracy and Validity

Purpose: To identify, through a systematic review, all validated tools used for the prediction of patient-reported outcome measures (PROMs) in patients being treated with radiation therapy for prostate cancer, and provide a comparative summary of accuracy and generalizability. Methods and Materials: PubMed and EMBASE were searched from July 2007. Title/abstract screening, full text review, and critical appraisal were undertaken by 2 reviewers, whereas data extraction was performed by a single reviewer. Eligible articles had to provide a summary measure of accuracy and undertake internal or external validation. Tools were recommended for clinical implementation if they had been externally validated and found to have accuracy ≥70%. Results: The search strategy identified 3839 potential studies, of which 236 progressed to full text review and 22 were included. From these studies, 50 tools predicted gastrointestinal/rectal symptoms, 29 tools predicted genitourinary symptoms, 4 tools predicted erectile dysfunction, and no tools predicted quality of life. For patients treated with external beam radiation therapy, 3 tools could be recommended for the prediction of rectal toxicity, gastrointestinal toxicity, and erectile dysfunction. For patients treated with brachytherapy, 2 tools could be recommended for the prediction of urinary retention and erectile dysfunction. Conclusions: A large number of tools for the prediction of PROMs in prostate cancer patients treated with radiation therapy have been developed. Only a small minority are accurate and have been shown to be generalizable through external validation. This review provides an accessible catalogue of tools that are ready for clinical implementation as well as which should be prioritized for validation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the accuracy of discretisations of the vector transport equation on the lowest-order quadrilateral Raviart-Thomas finite elements

Within finite element models of fluids, vector-valued fields such as velocity or momentum variables are commonly discretised using the Raviart-Thomas elements. However, when using the lowest-order quadrilateral Raviart-Thomas elements, standard finite element discretisations of the vector transport equation typically have a low order of spatial accuracy. This paper describes two schemes that improve the accuracy of transporting such vector-valued fields on two-dimensional curved manifolds. The first scheme that is presented reconstructs the transported field in a higher-order function space, where the transport equation is then solved. The second scheme applies a mixed finite element formulation to the vector transport equation, simultaneously solving for the transported field and its vorticity. In this work, an approach to stabilising this mixed vector-vorticity formulation is presented that uses a Streamline Upwind Petrov-Galerkin (SUPG) method. These schemes are then demonstrated, along with their accuracy properties, through some numerical tests. Two new test cases are used to assess the transport of vector-valued fields on curved manifolds, solving the vector transport equation in isolation. The improvement of the schemes is also shown through two standard test cases for rotating shallow-water models.

97 MATHEMATICS AND COMPUTING↗

A novel approach to increase accuracy in remotely sensed evapotranspiration through basin water balance and flux tower constraints

Remote sensing-derived evapotranspiration (RSET) products capture the spatiotemporal variations of evapotranspiration (ET) from field to basin scales with unprecedented details. However, their accuracy varies across RSET estimation methods and diverse hydroclimate regions. While ET modeling efforts to account for biophysical processes and controlling parameters have made good progress in recent years, a parallel approach of integrating in-situ ET with RSET could reduce biases in RSET products. Basin water balance ET (WBET) and flux tower ET are widely applied to evaluate RSET accuracy, yet such ET measurements are rarely used for RSET bias corrections, especially for large area applications. To address this issue, we propose a novel approach: the water balance equivalence (WABE) method, which generates spatially continuous WBET for correcting biases in RSET products. The WABE method computes synthetic WBET by integrating observed WBET and flux tower-derived FLUXCOM ET, which fills the spatial gaps of observed WBET and generates a spatially continuous WBET dataset. Synthetic WBET (2002–2015 annual average) of eight-digit hydrologic unit code (HUC8) basins across the conterminous United States (CONUS), constituting 44 % (887 out of 2035 basins) of CONUS basins, was determined within 2.0 % (RMSE = 12 %) of observed WBET at CONUS and between 1–12 % (RMSE = 3–33 %) across 18 regions in CONUS. With WABE-based bias corrections, the overall annual bias of RSET decreased from 10 % (RMSE = 34 %) to 6 % (RMSE = 26 %) across 37 flux tower sites. The WABE method offers a new approach for RSET accuracy improvement and shows great promise for large area implementations with a potential to yield substantial benefits for building accurate basin water budgets and water management decisions.

Khand, Kul↗

Graph interpolating activation improves both natural and robust accuracies in data-efficient deep learning

Improving the accuracy and robustness of deep neural nets (DNNs) and adapting them to small training data are primary tasks in deep learning (DL) research. In this paper, we replace the output activation function of DNNs, typically the data-agnostic softmax function, with a graph Laplacian-based high-dimensional interpolating function which, in the continuum limit, converges to the solution of a Laplace–Beltrami equation on a high-dimensional manifold. Furthermore, we propose end-to-end training and testing algorithms for this new architecture. The proposed DNN with graph interpolating activation integrates the advantages of both deep learning and manifold learning. Compared to the conventional DNNs with the softmax function as output activation, the new framework demonstrates the following major advantages: First, it is better applicable to data-efficient learning in which we train high capacity DNNs without using a large number of training data. Second, it remarkably improves both natural accuracy on the clean images and robust accuracy on the adversarial images crafted by both white-box and black-box adversarial attacks. Third, it is a natural choice for semi-supervised learning. This paper is a significant extension of our earlier work published in NeurIPS, 2018. For reproducibility, the code is available at https://github.com/BaoWangMath/DNN-DataDependentActivation .

Mathematics↗

Metabolite Spectral Accuracy on Orbitraps

Orbitraps are high-resolution ion-trap mass spectrometers that are widely used in metabolomics. While the mass accuracy and resolving power of orbitraps have been extensively documented, their spectral accuracy, i.e., accuracy in measuring the abundances of isotopic peaks, remains less studied. In analyzing spectra of unlabeled metabolites, we discovered a systematic under representation of heavier natural isotopic species, especially for high molecular weight metabolites (~20% under-measurement of [M + 1]/[M + 0] ratio at m/z 600). We hypothesize that these discrepancies arise for metabolites far from the lower limit of the mass scan range, due to the weaker containment in the C-trap that results in suboptimal trajectories inside the Orbitrap analyzer. Consistent with this, spectral fidelity was restored by dividing the mass scan range (initially 75 m/z to 1000 m/z) into two scan events, one for lower molecular weight and the other for higher molecular weight metabolites. Having thus obtained accurate mass spectra at high resolution, we found that natural isotope correction for high-resolution labeling data requires more sophisticated algorithms than typically employed: the correction algorithm must take into account whether isotopologues with the same nominal mass are resolved. We present an algorithm and associated open-source code, named AccuCor, for this purpose. Together, these improvements in instrument parameters and natural isotope correction enable more accurate measurement of metabolite labeling and thus metabolic flux.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effective Fragment Molecular Orbital Method: Achieving High Scalability and Accuracy for Large Systems

The effective fragment molecular orbital (EFMO) method has been developed to predict the total energy of a very large molecular system accurately (with respect to the underlying quantum mechanical method) and efficiently by taking advantage of the locality of strong chemical interactions and employing a two-level hierarchical parallelism. The accuracy of the EFMO method is partly attributed to the accurate and robust intermolecular interaction prediction between distant fragments, in particular, the many-body polarization and dispersion effects, which require the generation of static and dynamic polarizability tensors by solving the coupled perturbed Hartree–Fock (CPHF) and time-dependent HF (TDHF) equations, respectively. Solving the CPHF and TDHF equations is the main EFMO computational bottleneck due to the inefficient (serial) and I/O-intensive implementation of the CPHF and TDHF solvers. In this work, the efficiency and scalability of the EFMO method are significantly improved with a new CPU memory-based implementation for solving the CPHF and TDHF equations that are parallelized by either message passing interface (MPI) or hybrid MPI/OpenMP. Here, the accuracy of the EFMO method is demonstrated for both covalently bonded systems and noncovalently bound molecular clusters by systematically examining the effects of basis sets and a key distance-related cutoff parameter, R cut . R cut determines whether a fragment pair (dimer) is treated by the chosen ab initio method or calculated using the effective fragment potential (EFP) method (separated dimers). Decreasing the value of Rcut increases the number of separated (EFP) dimers, thereby decreasing the computational effort. It is demonstrated that excellent accuracy (<1 kcal/mol error per fragment) can be achieved when using a sufficiently large basis set with diffuse functions coupled with a small R cut value. With the new parallel implementation, the total EFMO wall time is substantially reduced, especially with a high number of MPI ranks. Given a sufficient workload, nearly ideal strong scaling is achieved for the CPHF and TDHF parts of the calculation. For the first time, EFMO calculations with the inclusion of long-range polarization and dispersion interactions on a hydrated mesoporous silica nanoparticle with explicit water solvent molecules (more than 15k atoms) are achieved on a massively parallel supercomputer using nearly 1000 physical nodes. In addition, EFMO calculations on the carbinolamine formation step of an amine-catalyzed aldol reaction at the nanoscale with explicit solvent effects are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Accuracy Semiempirical Quantum Models Based on a Minimal Training Set

A great need exists for computationally efficient quantum simulation approaches that can achieve an accuracy similar to high-level theories at a fraction of the computational cost. In this regard, we have leveraged a machine-learned interaction potential based on Chebyshev polynomials to improve density functional tight binding (DFTB) models for organic materials. The benefit of our approach is two-fold: (1) many-body interactions can be corrected for in a systematic and rapidly tunable process, and (2) high-level quantum accuracy for a broad range of compounds can be achieved with ~0.3% of data required for one advanced deep learning potential. Our model exhibits both transferability and extensibility through comparison to quantum chemical results for organic clusters, solid carbon phases, and molecular crystal phase stability rankings. Overall, our efforts thus allow for high-throughput physical and chemical predictions with up to coupled-cluster accuracy for systems that are computationally intractable with standard approaches.

36 MATERIALS SCIENCE↗