American Made Infrastructure: Evolution of Federal Incentives and Requirements

Foreign Entity of Concern (FEOC) restrictions in the One Big Beautiful Bill Act (OBBB) represent the latest evolution of a multi-year legislative trajectory responding to national security concerns about foreign control – and particularly FEOC control – of energy infrastructure. Beginning with Executive Order 14017 (February 2021), which initiated comprehensive federal review of critical supply chain vulnerabilities in semiconductors, battery energy storage systems, and critical minerals, policymakers have progressively expanded restrictions on foreign participation. The National Defense Authorization Act (NDAA) 2019 established precedent for component-level prohibitions on foreign information and communications technology procurement, while NDAA 2024 extended these restrictions to six major People’s Republic of China (PRC) battery manufacturers. Complementary measures such as the Build America, Buy America (BABA) Act and the Infrastructure Investment and Jobs Act (IIJA) introduced domestic content thresholds and FEOC eligibility criteria for federal funding programs. The Inflation Reduction Act (IRA) 2022 further operationalized FEOC restrictions through electric vehicle tax credit requirements, creating a scalable framework for excluding foreign-controlled components. Recent executive actions and state-level policies have reinforced this trajectory, reflecting sustained alignment across federal and state governments. Collectively, these developments demonstrate a bipartisan policy approach that pairs incentives for advanced energy deployment with safeguards designed to prevent subsidizing adversaries or entities that present foreign-sourcing risk.

99 - GENERAL AND MISCELLANEOUS↗

Center for Electrocatalysis, Transport Phenomena, and Materials (CETM) for Innovative Energy Storage - Final Report

EFRC vision. The direct use of organic hydrides in fuel cells as virtual hydrogen carriers that generate stable organic molecules, protons, and electrons upon electro-oxidation and can be electrochemically charged by re-hydrogenating the oxidized carrier was the major focus of the Center for Electrocatalysis, Transport Phenomena and Materials for Innovative Energy Storage (EFRC-ETM). Compared to a hydrogen-on-demand design that includes thermal decomposition of organic hydrides in a catalytic reactor, the proposed approach is much simpler and does not require additional dehydrogenation catalysts or heat exchangers. Further, this approach utilizes the advantages of a flow battery (i.e., separation of power and energy, ease of transport and storage of liquid fuels) with fuels that have system energy densities similar to current hydrogen PEM fuel cells. EFRC challenges. Two major EFRC challenges were electrocatalysis and transport phenomena. The electrocatalysis challenge addresses fundamental processes which occur at a single molecular catalyst (microscopic level) and involve electron and proton transfer between the hydrogen rich and hydrogen depleted forms of organic liquid fuel and the catalyst. To form stable, non-radical dehydrogenation products from the organic liquid fuel, it is necessary to ensure fast transport of at least two electrons and two protons (per double bond formation). The same is true for the reverse hydrogenation reaction. The transport phenomena challenge addresses transport of electrons to/from the electrocatalyst and the current collector as well as protons across the polymer membrane. Additionally it addresses prevention of organic liquid fuel, water and oxygen transport through the PEM. In this challenge, the transport of protons or molecules involves multiple sites or a continuum (macroscopic level) and water serves as a proton conducting medium for the majority of known sulfonic acid based PEMs. Proton transfer in the presence of prospective organic liquid fuels was studied. During EFRC program various types of electrocatalysts, classes of fuels, and membranes have been investigated.

25 ENERGY STORAGE↗

Roll-to-Roll Advanced Materials Manufacturing DOE Laboratory Collaboration (FY2020 Final Report)

R2R processing is used to manufacture a wide range of products for various applications which span many industrial business sectors. The overall R2R methodology has been in use for decades and this continuous technique traditionally involves deposition of material(s) onto moving webs, carriers or other continuous belt-fed or conveyor-based processes that enable successive steps to build a final version which serves to support the deposited materials. Established methods that typify R2R processing include tape casting, silk-screen printing, reel-to-reel vacuum deposition/coating, and R2R lithography. Products supported by R2R manufacturing include micro-electronics, electro-chromic window films, PVs, fuel cells for energy conversion, battery electrodes for energy storage, and barrier and membrane materials. Due to innovation in materials and process equipment, high-quality yet very low-cost multilayer technologies have the potential to be manufactured on a very cost-competitive basis. To move energy-related products from high-cost niche applications to the commercial sector, the means must be available to enable manufacture of these products in a cost-competitive manner that is affordable. Fortunately, products such as fuel cells, thin- and mid-film PVs, batteries, electrochromic and piezoelectric films, water separation membranes, and other energy saving technologies readily lend themselves to manufacture using R2R approaches. However, more early-stage research is needed to solve the challenge of linking the materials (particles, polymers, solvents, additives) used in ink and slurry formulations and the coating and drying processes to the ultimate performance of the final R2R product, especially for a process that uses multiple layers of deposition to achieve the end product. To solve the problems associated with these challenges, the R2R Collaboration is executing a research program with outcomes that will ultimately link modeling, processing, metrology and defect detection tools, thereby directly relating the properties of constituent particles and processing conditions to the performance of final devices. This collaborative approach was designed to foster identification and development of materials and processes related to R2R for clean-energy materials development. Using computational and experimental capabilities by acknowledged subject matter experts within the supported National Laboratory system, this project leverages the capabilities and expertise at each of five National Laboratories to further the development of multilayer technologies that will enable high-volume, cost-competitive platforms. A typical R2R process has three steps: (1) mixing of particles and various constituents in a slurry, (2) coating of the ink/slurry mixture on a substrate, and (3) drying/curing and processing of the coating. Final performance of devices made via R2R processes is dependent on the active materials (e.g., electrochemical particles in battery or fuel cell electrodes) and the device structure that stems from the governing component interactions within the various steps. However, a fundamental understanding of the underlying mechanisms and phenomena is still lacking, which is why industrial-scale R2R process development and manufacturing is still largely empirical in nature. The FY 2019 through FY 2021 program addresses aspects of the following two targets from the AMO Multi-Year Program Plan: (1) Target 8.1 Develop technologies to reduce the cost per manufactured throughput of continuous R2R manufacturing processes. (A) Increasing throughput of R2R processes by 5 times for batteries (to 50 square feet per minute (50 ft 2 /min)) and capacitors and 10 times for printed electronics and the manufacture of other substrates and MEs used in support of these products. (B) Developing resolution capabilities to enable registration and alignment that will detect, align, and co-deposit multiple layers of coatings and print < 1-micron (1 µm) features using continuous process scalable for commercial production. (C) Developing scalable and reliable R2R processes for solution deposition of ultra-thin (<10 nm) films for active and passive materials. (D) Develop in-line multilayer coating technology on thin films with yields greater than 95%. (2) Target 8.2 Develop in-line instrumentation tools that will evaluate the quality of single and multilayer materials in-process. (A) Developing in-line QC technologies and methodologies for real-time identification of defects and expected product properties “in-use/application” during continuous processing at all size-scales with a focus on the “micro” and “nano” scale traces, lines, and devices, i.e., <1 μm at 300 ft./min for R2R processing in air and <10 nm at 20 ft./min for vacuum (B) Developing technologies to increase the measurement frequency of surface rheology without significant cost increases with a goal of a 10-nanometer in-line profilometry at a production rate of 100,000 square millimeters per minute (100,000 mm 2 /min).

42 ENGINEERING↗

Optimal Scheduling of an Isolated Microgrid With Battery Storage Considering Load and Renewable Generation Uncertainties

By modeling the uncertainty of spinning reserves provided by energy storage with probabilistic constraints, a new optimal scheduling mode is proposed in this paper for minimizing the operating costs of an isolated microgrid (MG) by using chance-constrained programming. The model is transformed into a readily solvable mixed integer linear programming formulation in general algebraic modeling system (GAMS) via a proposed discretized step transformation approach and finally solved by applying the CPLEX solver. By properly setting the confidence levels of the spinning reserve probability constraints, the MG operation can achieve a tradeoff between reliability and economy. The test results on the modified Oak Ridge National Laboratory Distributed Energy Control and Communication lab MG test system reveal that the proposal significantly exceeds the commonly used hybrid intelligent algorithm with much better and more stable optimization results and significantly reduced calculation times.

Li, Yang↗

On-Ramp Wireless: Program Final Report

The objective of the project was to develop and demonstrate a centrally managed, wide area wireless distribution grid sensor and faulted circuit indicator system capable of monitoring underground and other hard-to-reach distribution circuits while delivering the reliability, ease of installation, security, battery life and low cost structure required to be a commercially viable product for the electric utility industry. This integrated wireless grid monitoring system enables utilities across the United States to enhance the reliability of their distribution grids, improve performance metrics (i.e., SAIFI, CAIDI, SAIDI), support dynamic load management and predictive maintenance, and enable future remote monitoring applications necessary to achieve the goals of the Smart Grid. This project scope included: conceptual design; trade studies focused on maximizing ease of installation, sensing capabilities, power budget analysis to reduce maintenance costs and time to replace; sensor product development; and field technology demonstration. The trade studies included Radio Frequency (RF) propagation. The RF Trade Study was completed for the 2.4 GHz ISM-band and not extended to 1 GHz band due to availability of suitable radio solutions and associated impacts to overall commercial value of the solution. The technology demonstrations/field trials were performed in partnership with Southern California Edison and San Diego Gas and Electric. The sensing systems included fault indicator and wireless analog sensor devices from Schweitzer Engineering Labs (SEL) and smart transformer monitoring devices from Gridsense. Both SEL and Gridsense worked with ORW during this project to During the demonstration phase, sensors were deployed in multiple locations. Resulting data was analyzed for the following: RF performance, communication systems reliability, sensor system capabilities, and system level analytics relative to the commercial value to the smart grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY2017 annual report: Roll-to-Roll Advanced Materials Manufacturing DOE Laboratory Consortium Project

The following report provides a description of the program structure and technical accomplishments made during FY 2017 to overcome challenges for expanding use of R2R technologies and processing for clean energy applications. Technologies are under development that enable enhanced manufacturing of battery electrodes, fuel cells and water separation membranes that take advantage of advancements in new functional materials. Data mining, visualization, modeling and simulation for the materials, technologies and processes being developed allow for improvements in R2R manufacturing applications. This report documents the research conducted by four DOE national laboratories as a consortium in collaboration with industry partnerships. The research is directly applicable to AMM strategies that apply the National Science and Technology Council’s Materials Genome Initiative (NSTC 2011) approach to enhance the performance of battery, fuel cell and water membrane materials. This effort supports building the foundation of technologies, processes and a U.S. manufacturing base that will enable an order of magnitude in shorter process development cycles with the pathway for initial commercialization within months instead of years.

36 MATERIALS SCIENCE↗

Ames National Laboratory Annual Site Environmental Report for CY2021

The primary purpose of this report is to summarize the performance of Ames National Laboratory’s environmental programs, present highlights of significant environmental activities, and confirm compliance with environmental regulations and requirements for calendar year 2021. This report is a working requirement of Department of Energy Order 231.1B, Environment, Safety and Health Reporting. It includes descriptions of the Laboratory’s site, mission, the status of its compliance with applicable environmental regulations, its planning and activities to maintain compliance, and a comprehensive review of its environmental protection, surveillance and monitoring activities. Ames National Laboratory is located on the campus of Iowa State University (ISU) and occupies 13 buildings owned by the Department of Energy (DOE). See the Laboratory’s Web page for location and Laboratory overview. The Laboratory also leases space in ISU owned buildings. In 2021, the Laboratory accumulated and disposed of hazardous waste under a U.S. Environmental Protection Agency (EPA) issued generator number. All waste was handled according to applicable EPA, State, and local regulations and DOE Orders. The Laboratory operates as a Small Quantity Generator (SQG) of hazardous waste. There were no radiological air emissions or exposures to the general public due to Laboratory activities in 2021 (See U.S. Department of Energy Air Emissions Annual Report in Appendix A.) The Laboratory has an established Environmental Radiological Protection Program (Plan 10200.041) per DOE Order 458.1 requirements. Plans, policies, and procedures are in place to protect the public and the environment against undue risk from radiation associated with DOE radiological activities. As indicated in prior Site Environmental Reports, formal pollution prevention awareness, waste minimization and recycling programs have been in practice since 1990, with improvements implemented most recently in 2017 with Iowa State University’s shift toward single-stream recycling. Included in recycling efforts are items such as batteries, monitors, corrugated cardboard, lamps, miscellaneous electronic office equipment, mixed paper, newsprint, food/beverage containers, and laboratory glassware. Ames National Laboratory also recycles/reuses salvageable metal, used oil, and foamed polystyrene peanuts, and encourages chemical redistribution and sharing among research groups. Ames National Laboratory reported its contractual performance to DOE-Ames Site Office (AMSO) through the Laboratory’s Performance Evaluation Measurement Plan (PEMP), and a performance level of “B+” was achieved in 2021 for Sustain Excellence and Enhance Effectiveness of Integrated Safety, Health, and Environmental Protection As reported in Site Environmental Reports for prior years, the Laboratory’s Environmental Management System (EMS) has been integrated into the Laboratory’s Integrated Safety Management System (ISMS) since 2005. The integration of EMS into Laboratory business practices allows the Laboratory to systematically review, address and respond to environmental impacts. In addition to DOE-identified objectives and targets, the EMS Steering Committee recommends annual environmental goals for the Laboratory. Due to the COVID-19 pandemic and limited onsite work staff, goals of reducing water usage and travel/commuting to promote the reduction of scope 3 greenhouse gases were achieved. All contract deliverables and environmental compliance activities were still met during this time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Depot Charging Schedule Optimization for Medium- and Heavy-Duty Battery-Electric Trucks

Charge management, which lowers charging costs for fleets and prevents straining the electrical grid, is critical to the successful deployment of medium- and heavy-duty battery-electric trucks (MHD BETs). This study introduces an energy demand and cost management framework that optimizes depot charging for MHD BETs by combining an energy consumption machine learning model and a linear program optimization model. The framework considers key factors impacting real-world MHD BET operations, including vehicle and charger configurations, duty cycles, use cases, geographic and climate conditions, operation schedules, and utilities’ time-of-use (TOU) rates and demand charges. The framework was applied to a hypothetical fleet of 100 MHD BETs in California under three different utilities for 365 days, with results compared to unmanaged charging. The optimized charging solution avoided more than 90% of on-peak charging, reduced fleet charging peak load by 64–75%, and lowered fleet energy variable costs by 54–64%. This study concluded that the proposed charge management framework significantly reduces energy costs and peak loads for MHD BET fleets while making recommendations for fleet electrification infrastructure planning and the design of utility TOU rates and demand charges.

Song, Shuhan↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Modeling the performance and cost of lithium-ion batteries for electric-drive vehicles.

This report details the Battery Performance and Cost model (BatPaC) developed at Argonne National Laboratory for lithium-ion battery packs used in automotive transportation. The model designs the battery for a specified power, energy, and type of vehicle battery. The cost of the designed battery is then calculated by accounting for every step in the lithium-ion battery manufacturing process. The assumed annual production level directly affects each process step. The total cost to the original equipment manufacturer calculated by the model includes the materials, manufacturing, and warranty costs for a battery produced in the year 2020 (in 2010 US$). At the time this report is written, this calculation is the only publically available model that performs a bottom-up lithium-ion battery design and cost calculation. Both the model and the report have been publically peer-reviewed by battery experts assembled by the U.S. Environmental Protection Agency. This report and accompanying model include changes made in response to the comments received during the peer-review. The purpose of the report is to document the equations and assumptions from which the model has been created. A user of the model will be able to recreate the calculations and perhaps more importantly, understand the driving forces for the results. Instructions for use and an illustration of model results are also presented. Almost every variable in the calculation may be changed by the user to represent a system different from the default values pre-entered into the program. The distinct advantage of using a bottom-up cost and design model is that the entire power-to-energy space may be traversed to examine the correlation between performance and cost. The BatPaC model accounts for the physical limitations of the electrochemical processes within the battery. Thus, unrealistic designs are penalized in energy density and cost, unlike cost models based on linear extrapolations. Additionally, the consequences on cost and energy density from changes in cell capacity, parallel cell groups, and manufacturing capabilities are easily assessed with the model. New proposed materials may also be examined to translate bench-scale values to the design of full-scale battery packs providing realistic energy densities and prices to the original equipment manufacturer. The model will be openly distributed to the public in the year 2011. Currently, the calculations are based in a Microsoft{reg_sign} Office Excel spreadsheet. Instructions are provided for use; however, the format is admittedly not user-friendly. A parallel development effort has created an alternate version based on a graphical user-interface that will be more intuitive to some users. The version that is more user-friendly should allow for wider adoption of the model.

25 ENERGY STORAGE↗

Modeling the Performance and Cost of Lithium-Ion Batteries for Electric-Drive Vehicles (Second Edition)

This report details the Battery Performance and Cost model (BatPaC) developed at Argonne National Laboratory for lithium-ion battery packs used in automotive transportation. The model designs the battery for a specified power, energy, and type of vehicle battery. The cost of the designed battery is then calculated by accounting for every step in the lithium-ion battery manufacturing process. The assumed annual production level directly affects each process step. The total cost to the original equipment manufacturer calculated by the model includes the materials, manufacturing, and warranty costs for a battery produced in the year 2020 (in 2010 US$). At the time this report is written, this calculation is the only publicly available model that performs a bottom-up lithium-ion battery design and cost calculation. Both the model and the report have been publicly peer-reviewed by battery experts assembled by the U.S. Environmental Protection Agency. This report and accompanying model include changes made in response to the comments received during the peer-review. The purpose of the report is to document the equations and assumptions from which the model has been created. A user of the model will be able to recreate the calculations and perhaps more importantly, understand the driving forces for the results. Instructions for use and an illustration of model results are also presented. Almost every variable in the calculation may be changed by the user to represent a system different from the default values pre-entered into the program. The distinct advantage of using a bottom-up cost and design model is that the entire power-to-energy space may be traversed to examine the correlation between performance and cost. The BatPaC model accounts for the physical limitations of the electrochemical processes within the battery. Thus, unrealistic designs are penalized in energy density and cost, unlike cost models based on linear extrapolations. Additionally, the consequences on cost and energy density from changes in cell capacity, parallel cell groups, and manufacturing capabilities are easily assessed with the model. New proposed materials may also be examined to translate bench-scale values to the design of full-scale battery packs providing realistic energy densities and prices to the original equipment manufacturer.

25 ENERGY STORAGE↗

Next Generation RivGen Power System: Kvichak River, AK Overwinter Ice Study

The University of Alaska Fairbanks (UAF) Alaska Hydrokinetic Energy Research Center was tasked with developing a real-time data telemetry / remote power generation system to monitor frazil ice conditions in the Kvichak River in support of the U.S. Department of Energy funded "Next Generation MHK River Power System Optimized for Performance, Durability and Survivability" project. A real-time telemetry system was requested because of the short time span between the end of the frazil ice season when the instruments would be recovered, limited vessel availability and the project end-date. To meet the project objectives, UAF designed and assembled a remote power/real-time data telemetry system that included an auto start propane generator, a small PV array, a small battery bank and line-of-sight radios as well as two sonar systems to monitor river velocity and water column acoustic backscatter strength. Both sonars included internal batteries for powering the instruments in case of failure of the shore based power system. The sonars, deployed in ~5 m of water on the bed of the Kvichak River, adjacent to the Village of Igiugig, Alaska were tethered to shore via a waterproof armored cable that conveyed power to the subsurface instruments and data from the instruments to the shore based telemetry system. The instruments were programmed to record data internally as well as to transmit data serially over the cables to the shore based system. The system was in-place between November, 2016 and June, 2017. While the real-time data telemetry system was not successful and the remote power generation power system was only partially successful, the system design included sufficient redundant power in the form of internal instrument batteries to enable the collection of nearly three months of overlapping velocity and backscatter data (from November through February) and a record of acoustic backscatter strength spanning the entire ~150 day frazil ice season between November, 2016 and ~April, 2017. This submission includes the overwinter ice study plan, raw data, and report.

16 TIDAL AND WAVE POWER↗

Harnessing Virtual Power Plants Reliably: Enabling tools for increased observability, controllability, operation, and aggregation of distributed energy resources

Harnessing virtual power plants enhances the integration of distributed energy resources into utility grids for a sustainable energy future. Virtual power plants (VPPs) aggregate DERs to enhance resource adequacy and reduce emissions. U.S. utilities are exploring various technologies to manage DERs effectively. FERC Order 2222 allows DERs to participate in both wholesale and retail markets. Enhancing observability and controllability of behind-the-meter (BTM) DERs is essential for reliable grid operations. A hierarchical control architecture can improve coordination among residential energy resources. Field tests showed nearly 20% energy savings and 30% peak power reduction during grid events. Effective management of DERs requires enhanced situational awareness to prevent grid congestion. Integrating DER management systems (DERMS) with existing planning tools can improve operational security. Near-real-time grid models can validate optimal resource set points against resource uncertainty. Traditional uninterruptible power supplies (UPS) can be upgraded to support grid services and become part of VPPs. Upgrading UPS systems can reduce costs by 75% and unlock significant battery capacity. New battery management systems and grid-aware controllers are essential for optimizing UPS performance. Continued research and development are necessary to address challenges in integrating DERs into utility grids. Encouraging customer participation in pilot programs is vital for the evolution of VPPs. Here, the shift towards price-responsive DERs and VPPs is expected to enhance energy distribution efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainable Federal Fleets: Deploying Electric Vehicles and Electric Vehicle Supply Equipment

The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) helps federal agencies reduce petroleum consumption and increase alternative fuel use through its resources for Sustainable Federal Fleets. To assist agencies with the transition to plug-in electric vehicles (PEVs), including battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs), FEMP offers technical guidance on electric vehicle supply equipment (EVSE) installations and site-specific planning through partnerships with the National Renewable Energy Laboratory's (NREL's) EVSE Tiger Teams.

30 DIRECT ENERGY CONVERSION↗

Modeling the Performance and Cost of Lithium-Ion Batteries for Electric-Drive Vehicles, Third Edition

This Manual details the Battery Performance and Cost model (BatPaC) developed at Argonne National Laboratory for lithium-ion battery packs used in automotive transportation. The model designs the battery for a specified power, energy, and type of vehicle battery. The cost of the designed battery is then calculated by accounting for every step in the lithium-ion battery manufacturing process. The assumed annual production level directly affects each process step. The total price to vehicle manufacturers calculated by the model represent both our estimates for the present-day costs and projected costs for up to ten years in the future, depending upon the designated scale of production. BatPaC assumes that future plants with production volumes of up to 500,000 EV batteries per year would be highly automated resulting in lower capital equipment and labor costs per unit produced than present day plants that have lower production volumes. All costs are calculated in US$ for the year of the estimate with all input costs for that same year. BatPaC is the only publicly available model of which we are aware that performs a bottom-up lithium-ion battery design and cost calculation. The original model and Manual were publicly peer-reviewed by battery experts assembled by the U.S. Environmental Protection Agency. This revised model and Manual include changes made in response to the comments received from the users; most of the changes were made over a number of years and are summarized here. The purpose of the report is to document the equations and assumptions from which the model has been created. A user of the model will be able to recreate the calculations and perhaps more importantly, understand the driving forces for the results. Instructions for use and illustrations of the model results are also presented. Almost every variable in the calculation may be changed by the user to represent a system different from the default values pre-entered into the program. The distinct advantage of using a bottom-up cost and design model is that the entire power-to-energy space may be traversed to examine the correlation between performance and cost. The BatPaC model accounts for the physical limitations of the electrochemical processes within the battery. Thus, unrealistic designs are penalized in energy density and cost, unlike cost models based on linear extrapolations. Additionally, the consequences on cost and energy density from changes in cell capacity, parallel cell groups, and manufacturing capabilities are easily assessed with the model. New proposed materials may also be examined to translate bench-scale values to the design of full-scale battery packs providing realistic energy densities and prices to the original equipment manufacturer.

25 ENERGY STORAGE↗