Search NASA⌕ Search

SEARCH · Search NASA

Results for “BRAGG REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Semiconductor Heterolasers with Double-Mirror Two-Dimensional Bragg Resonators

A double-mirror two-dimensional Bragg resonator design based on structures of planar geometry, which is typical of both band-to-band and quantum-cascade heterolasers, is suggested. The distinguishing feature of this design is the coupling between longitudinal and transverse energy flows in two-dimensional Bragg mirrors. The eigenmode spectrum of the structure is described. It is shown that the proposed design can be used for synchronizing radiation emitted in lasers and laser arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Properties of Metal-Dielectric Structures Based on Photon-Crystal Opal Matrices

Optical properties of novel metal–dielectric nanocomposite materials based on opal matrices have been investigated. The position of optical resonances of nanocomposites, obtained by embedding of silver into the opal matrix by the electrothermodiffusion method, is explained by the Bragg diffraction, and an asymmetric form of resonance curves is attributed to the Fano resonance. An anomalous transmission and absorption of light by hybrid plasmon-photonic layered heterostructures, which is apparently associated with excitation of surface plasmon-polaritons, propagating along “metal–dielectric” interfaces, was revealed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Acousto-Optic Control of the Energy Profile of Laser Radiation

An acousto-optic shaper is developed for transformation of the Gaussian beam profile into almost rectangular profile. As distinct from lens devices, an acousto-optic device allows modification of the shape of the output beam in a fixed optical configuration using changes in radio control with relatively short response times of about 10 μs. The method is based on multibeam high-efficiency Bragg diffraction when the diffraction orders are overlapped with respect to angle. It is shown that the beam profile can be transformed into rectangular and more complicated profiles with an efficiency of no less than 80%. The experiments are performed using the TeO{sub 2} crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acousto-Optic Diffraction in Paratellurite by a Slow Acoustic Mode. Increase of Diffraction Efficiency of Divergent Light

Peculiarities of anisotropic acousto-optic Bragg diffraction in paratellurite by a slow acoustic wave have been considered. The ranges of frequency-angular dependences have been found, in which effective diffraction occurs, and their practical relevance has been formulated. The numerical values for light radiation with a wavelength of 1.06 μm have been obtained. We have proposed the method of enhancement of a diffraction efficiency of divergent optical radiation, which in turn leads to the increase of the response time of an acousto-optical modulator. The method is based on a multifrequency electric control of the acousto-optical modulator. We have shown experimentally that, as distinct from the single-frequency control, a considerable intensity suppression of the zero diffraction order from 30 to 8% is achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bragg Deflectors of Wave Fluxes for High-Power Relativistic Masers

Quasi-optical Bragg structures that represent sections of planar waveguides with tilted (with respect to the beam propagation direction) corrugation are studied. It is shown that such structures may serve as efficient deflectors for high-power wave fluxes and, hence, can be used for separation of microwave radiation and electron beam in relativistic masers. The corrugation configuration is optimized to increase the efficiency of transformation of wave fluxes to the transverse direction and improve uniformity of the spatial distribution of scattered radiation. The simulated results are verified using cold electrodynamic tests.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying the uncertainty of synchrotron-based lattice strain measurements

Crystallographic lattice strains - measured using diffraction techniques - are the same magnitude as typical macroscopic elastic strains. From a research perspective, the main interest is in measuring changes in lattice strains induced during in-situ loading: either from one macroscopic stress level to another or from one cycle to the next. The hope is to link these measurements to deformation-induced changes in the internal structure of crystals, possibly related to inelastic deformation and damage. These measurements are relatively new - little experimental intuition exists and it is difficult to discern whether observed differences are due to actual micromechanical evolution or to random experimental fluctuations. If the measurements are linked to material evolution on the size scale of the individual crystal, they have the potential to change the ideas about grain scale deformation partitioning processes and can be used to validate crystal-based simulation frameworks. Therefore, understanding the uncertainty associated with the lattice strain experiments is a crucial step in their continued development. If the measured lattice strains are of the same order as the random fluctuations that are part of the measurement process, documenting the strains can create more confusion than understanding. Often lattice strain error is quoted as {+-}1 x 10{sup -4}. This simple value fails to account for the range of factors that contribute to the experimental uncertainty - which, if not properly accounted for, may lead to a false confidence in the measurements. The focus of this paper is the development of a lattice strain uncertainty expression that delineates the contributing factors into terms that vary independently: (i) the contribution from the instrument and (ii) the contribution from the material under investigation. These aspects of uncertainty are described, and it is then possible to employ a calibrant powder method (diffraction from an unstrained material with high-precision lattice constants) to quantify the instrument portion of the lattice strain uncertainty. In these experiments, the instrument contribution to the uncertainty has been found to be a function of the Bragg angle and the intensity of the diffracted peaks. To develop a model for the instrument portion of the lattice strain uncertainty two datasets obtained using a MAR345 online image plate at the Cornell High Energy Synchrotron Source and a GE 41RT amorphous silicon detector at the Advanced Photon Source have been examined.

43 PARTICLE ACCELERATORS↗

Temporal thermal response of Type II-IR fiber Bragg gratings

We use the phase mask method to investigate both experimentally and theoretically the temporal thermal response of Type II-IR fiber Bragg gratings inscribed by a femtosecond laser. A fast testing system is developed to measure the thermal response time by means of periodic CO2 laser irradiation, which creates a rapid temperature change environment. The temporal thermal response is found to be independent of the heat power and the heat direction, although the grating produced destroys the axial symmetry of the fiber. The measured values of the temporal thermal response are {approx}230 ms for heating and {approx}275 ms for cooling, which different from the simulation results obtained from a lumped system equation. The causes of such differences are investigated in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and characterization of chalcogenide glass for hollow Bragg fibers

Low- and high-refractive-index chalcogenide glasses are studied for their potential use in the fabrication of one-dimensional hollow Bragg fibers. The low-index glasses are based on the GeSe-glass systems with indices varying from 2.0 to 2.5, while the high-index glasses are formed from the AgAsSe glasses with indices ranging from 2.8 to 3.8. High-purity elemental starting materials are distilled and the surface oxides removed prior to mixing in a rocking furnace. The refractive indices of the AgAsSe glasses, measured using a CO2 laser reflectometer, were near 3.10 for the compositions most compatible with the low-index Ge20Se80 glass (n=2.46). Spectral measurements show impurity absorption bands between 12 and 16 {mu}m. The loss at 10.6 {mu}m for the Ag25As40Se35 glass measured using CO2 laser calorimetry was 1.16x10{sup -3} cm{sup -1}.

36 MATERIALS SCIENCE↗

Directly photoinscribed refractive index change and Bragg gratings in Ohara WMS-15 glass ceramic

We inscribed thick volume gratings in WMS-15 glass ceramic by ultraviolet light at 193 and 248 nm. Unlike earlier work in ceramic materials, the inscription process modified the optical properties of the material without the need for any additional chemical or thermal processing. Experimental evidence from measurements of grating growth, thermal annealing, and spectral absorption indicates that two distinct physical mechanisms are responsible for the grating formation. Weak, easily thermally bleached gratings resulted from exposure fluences below 0.3 kJ/cm{sup 2}. Optical absorption measurements suggest that these low fluence gratings are predominantly absorption gratings. More thermally stable gratings, found to be refractive index gratings with unsaturated refractive index modulation amplitude as large as 6x10{sup -5} were formed at cumulative fluences of 1 kJ/cm{sup 2} and above.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bragg cell laser intensity modulation: effect on laser Doppler velocimetry measurements

In most laser Doppler velocimetry (LDV) systems, the frequency of one of the two laser beams that intersect to create the probe volume is shifted with an acousto-optic element. It is shown here that Bragg shifting can impose a problematic fluctuation in intensity on the frequency-shifted beam, producing spurious velocity measurements. This fluctuation occurs at twice the Bragg cell frequency, and its relative amplitude to the time average intensity is a function of the ratio of the laser beam diameter to the Bragg cell acoustic wavelength. A physical model and a configuration procedure to minimize adverse effects of the intensity modulations are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray diffraction effect from surface acoustic waves traveling on a deposited multilayer

We investigate the x-ray diffraction effects from surface acoustic waves (SAW) traveling along a multilayer. The diffraction intensity distribution depends on the incidence angle and the multilayer SAW (MLSAW) amplitude. Particularly, a small departure deviating from the Bragg incidence angle at a certain amplitude will produce a larger variation of the intensity distribution. This shows that the diffraction intensity from MLSAW has an extremely high sensitivity to the Bragg incidence angle, which is different from a SAW traveling along a solid surface without deposited layers. By carefully analyzing the relationship between the intensity distribution I and the incidence angle {theta}, the corresponding analytic expression of the intensity distribution is theoretically derived. Our theoretical prediction is in great agreement with the experimental results previously obtained. A theoretical model that can be applied to study the x-ray diffraction effect from MLSAW is developed. The extremely high sensitivity to the Bragg angle will help us in acousto-optic instrument research with MLSAW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A framework for 3-D coherent diffraction imaging by focused beam x-ray Bragg ptychography.

We present the framework for convergent beam Bragg ptychography, and, using simulations, we demonstrate that nanocrystals can be ptychographically reconstructed from highly convergent x-ray Bragg diffraction. The ptychographic iterative engine is extended to three dimensions and shown to successfully reconstruct a simulated nanocrystal using overlapping raster scans with a defocused curved beam, the diameter of which matches the crystal size. This object reconstruction strategy can serve as the basis for coherent diffraction imaging experiments at coherent scanning nanoprobe x-ray sources.

99 GENERAL AND MISCELLANEOUS↗

High-power narrow spectrum GaSb-based DBR lasers emitting near 2.1 µm

Stable high-power narrow-linewidth operation of the 2.05–2.1 µm GaSb-based diode lasers was achieved by utilizing the sixth-order surface-etched distributed Bragg reflector (DBR) mirrors. The DBR multimode devices with 100 µm wide ridge waveguides generated ~850 mW in the continuous wave (CW) regime at 20°C. The device CW output power was limited by thermal rollover. The laser emission spectrum was defined by Bragg reflector reflectivity at all operating currents in a wide temperature range. Finally, the devices operated at DBR line with detuning from gain peak exceeding 10 meV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Scattering of X-Rays

The purpose of this report and its derivations is to account for magnetic scattering of photons by magnetization densities in matter as discussed by de Bergevin and Brun (Acta Cryst. A37, 314 (1981))

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polarimeter for celestial X rays.

Polarimeter using 45 degree Bragg angle reflection applied to rocket payload design for determining polarization of celestial sources X rays

Kalata, K.↗

Stellar and solar X-ray polarimetry

Astronomical stellar and solar studies involving X-ray polarimetry are discussed along with the statistical limitations inherent in polarimeter measurements and the design principles of a number of polarimeter types. Attention is given to photoelectric polarimeters, secondary fluorescence X-ray polarimeters, Borrmann-effect polarimeters, circular polarization analyzers, gamma-ray polarimeters, and multilayer reflection polarimeters. Bragg crystal polarimeters are considered, taking into account the theory of the polarimeter operation, aspects of instrument design, and the occurrence of systematic errors. The design and the performance of a rocket and a satellite Thomson-scattering polarimeter are also examined.

Novick, R.↗

A large-area lithium-fluoride Bragg spectrometer for stellar X-ray astronomy

A large-area Bragg spectrometer used to search for the Fe XXV X-ray emission lines of Sco X-1 is described. The device has 3400 sq cm of LiF on nine crystal panels aligned perpendicular to the longitudinal axis of the rocket. X rays satisfying the Bragg condition reflect into an array of nine companion proportional counters. A pointing system incorporating a free gyroscope with 2 degrees of freedom assures that target X rays are reflected at the required angle and produces repeated spectral scans of the X-ray continuum, which are later superimposed to correct temporal effects. The instrument is capable of detecting a narrow line flux from Sco X-1 of about .01 photons/sq cm/sec.

Stockman, H. S., Jr.↗

Distributed feedback acoustic surface wave oscillator

An acoustic surface wave oscillator is constructed from a semiconductor piezoelectric acoustic surface wave amplifier by providing appropriate perturbations at the piezoelectric boundary. The perturbations cause Bragg order reflections that maintain acoustic wave oscillation under certain conditions of gain and feedback.

Elachi, C.↗