Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Results of baseline tests of the EVA Metro sedan, Citi-car, Jet Industries Electra-van, CDA town car, and Otis P-500 van

Five electric vehicles were tested at vehicle test tracks using the SAE. The tests provide range data at steady speeds and for several driving cycles. Most tests were conducted with lead-acid traction batteries. The Otis Van and the Copper Electric Town Car were also tested with lead-acid and nickel-zinc batteries. The tests showed a range increase of from 82 to 101 percent depending on vehicle, speed, and test cycle.

Stenger, F. J.↗

Development of automated electromagnetic compatibility test facilities at Marshall Space Flight Center

The efforts to automate the electromagentic compatibility (EMC) test facilites at Marshall Flight Center were examined. A battery of nine standard tests is to be integrated by means of a desktop computer-controller in order to provide near real-time data assessment, store the data acquired during testing on flexible disk, and provide computer production of the certification report.

Harrison, Cecil A.↗

Global Precipitation Measurement (GPM) Spacecraft Lithium Ion Battery Micro-Cycling Investigation

The Global Precipitation Measurement (GPM) spacecraft was jointly developed by NASA and JAXA. It is a Low Earth Orbit (LEO) spacecraft launched on February 27, 2014. The power system is a Direct Energy Transfer (DET) system designed to support 1950 watts orbit average power. The batteries use SONY 18650HC cells and consist of three 8s by 84p batteries operated in parallel as a single battery. During instrument integration with the spacecraft, large current transients were observed in the battery. Investigation into the matter traced the cause to the Dual-Frequency Precipitation Radar (DPR) phased array radar which generates cyclical high rate current transients on the spacecraft power bus. The power system electronics interaction with these transients resulted in the current transients in the battery. An accelerated test program was developed to bound the effect, and to assess the impact to the mission.

Lithium Ion Battery Performance↗

Response of lead-acid batteries to chopper-controlled discharge

The results of tests on an electric vehicle battery, using a simulated electric vehicle chopper-speed controller, show energy output losses up to 25 percent compared to constant current discharges at the same average current of 100 A. However, an energy output increase of 22 percent is noticed at the 200 A average level and 44 percent increase at the 300 A level using pulse discharging. Because of these complex results, electric vehicle battery/speed controller interactions must be considered in vehicle design.

Cataldo, R. L.↗

Evaluation of nickel-hydrogen battery for space application

Results of electrical space qualification tests of nickel-hydrogen battery type HR 23S are presented. The results obtained for the nickel-cadmium battery type VO 23S are similar except that the voltage level and the charge conservation characteristics vary significantly. The electrical and thermal characteristics permit predictions of the following optimal applications: charge coefficient in the order of 1.3 to 1.4 at 20C; charge current density higher than C/10 at 20C; discharge current density from C/10 to C/3 at 20C; maximum discharge temperature: OC; storage temperature: -20C.

Billard, J. M.↗

Tuning the Solar Dynamics Observatory Onboard Kalman Filter

The Solar Dynamics Observatory (SDO) was launched in 2010. SDO is a sun pointing semi-autonomous spacecraft in a geosynchronous orbit that allows nearly continuous observations of the sun. SDO is equipped with coarse sun sensors, two star trackers, a digital sun sensor, and three two-axis inertial reference units (IRU). The IRUs are temperature sensitive and were designed to operate in a stable thermal environment. Due to battery degradation concerns the IRU heaters were not used on SDO and the onboard filter was tuned to accommodate the noisier IRU data. Since launch currents have increased on two IRUs, one had to eventually be powered off. Recent ground tests on a battery similar to SDO indicated the heaters would have negligible impact on battery degradation, so in 2016 a decision was made to turn the heaters on. This paper presents the analysis and results of updating the filter tuning parameters onboard SDO with the IRUs now operating in their intended thermal environment.

Halverson, Julie Kay↗

Power systems testing

The Space Station Freedom (SSF) will give the U.S. a permanent manned presence in space in 1999. The SSF underwent its final design concept in 1991. Launches of hardware will begin in late 1995, and the SSF will become operational in the man tended configuration in 1997. Additional Space Shuttle flights between 1997 and 1999 will complete the SSF. Along with international partners, a crew of four astronauts will conduct long-term experimentation in the microgravity environment of the orbiting spacecraft. Lewis Research Center, along with its prime contractor, will provide the electrical power system (EPS) for SSF. Two major testing facilities at the Lewis Research Center will support the Lewis EPS. The Power Systems Facility provides test beds for life testing the station batteries and the power management distribution system testbed. This testbed simulates two channels of the EPS. The Space Power Facility at the Lewis Plum Brook Station is the largest vacuum chamber in the world. Within this chamber, a simulated space environment, testing of full-size EPS components will occur.

Source record↗

Electric and hybrid vehicles charge efficiency tests of ESB EV-106 lead acid batteries

Charge efficiencies were determined by measurements made under widely differing conditions of temperature, charge procedure, and battery age. The measurements were used to optimize charge procedures and to evaluate the concept of a modified, coulometric state of charge indicator. Charge efficiency determinations were made by measuring gassing rates and oxygen fractions. A novel, positive displacement gas flow meter which proved to be both simple and highly accurate is described and illustrated.

Rowlette, J. J.↗

Preliminary testing of a prototype portable X-ray fluorescence spectrometer

A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.

Patten, L. L.↗

Test Procedures for Characterizing, Evaluating, and Managing Separator Materials used in Secondary Alkaline Batteries

Secondary alkaline batteries, such as nickel-cadmium and silver-zinc, are commonly used for aerospace applications. The uniform evaluation and comparison of separator properties for these systems is dependent upon the measurement techniques. This manual presents a series of standard test procedures that can be used to evaluate, compare, and select separator materials for use in alkaline batteries. Detailed test procedures evaluating the following characteristics are included in this manual: physical measurements of thickness and area weight, dimensional stability measurements, electrolyte retention, resistivity, permeability as measured via bubble pressure, surface evaluation via SEM, chemical stability, and tensile strength.

Guasp, Edwin↗

The Galileo probe Li/SO2 battery

NASA's Galileo mission to Jupiter will consist of an orbiter and a probe, the probe to descend through and analyze the Jovian atmosphere. All power for the probe will be supplied by three battery modules containing a total of 39 D size Li/SO2 cells that will be required to retain capacity for the duration of the mission (over 50 months) and then provide current at 3 to 4 amperes for 48 minutes. The design, development, and testing of this battery are described herein.

Marcoux, L.↗

Exploration Exercise System (EES) Development

Exploration class missions will be required to have an exercise device that is lightweight, has a small footprint, and is capable of providing enough physical stimulus and exercise variability to be an effective countermeasure against muscle and bone loss that results from the microgravity environment. Exploration exercise device prototypes should be evaluated on the ground and in-orbit for feasibility of use in microgravity for long and short duration exploration missions and efficacy of the device to maintain multi-system health and performance. The European Enhanced Exploration Exercise Device (E4D) was selected as the exploration prototype device to be evaluated on ISS for efficacy and feasibility of use as a single multi-modality device for the exercise system for exploration missions. This effort supports the continued development, testing, and verification of E4D hardware and software, internal NASA integration (Human Health and Performance, ISS Vehicle Office, Engineering, and Flight Operations), and external integration across NASA, ESA, and the Danish Aerospace Company (DAC). Providing a feasibility and acceptability assessment from a physiological efficacy and hardware durability standpoint are critical for informing use and risk associated with use on exploration missions. Clearly defined objectives from end users, stakeholders, and Subject Matter Experts (SMEs) will be tested by crewmembers during acute use sessions and long duration use of the exercise device while on ISS. This effort will include a flight study where crewmembers will be asked to exercise using only the E4D during the duration of their mission and participate in a battery of physiological testing to evaluate the efficacy. Hardware is scheduled to launch in FY25 followed by 2 years of operational use after activation and checkout. A final recommendation will be provided to the Artemis program on acceptability of the device for exploration missions. The E4D needs a vibration isolation stabilization (VIS) system that serves as a platform for the exercise hardware to protect the vehicle from loads imparted during exercise. Exploration forward VIS systems will need to protect the vehicle and provide sufficient stabilization for the exerciser during performance of all critical exercises. These enabling capabilities need to be achieved within exploration vehicle power, thermal, mass, and volume limitations.

Kent Lawrence Kalogera↗

Hydrogen recombination in sealed nickel-cadmium aerospace cells

The paper presents a mechanism which offers an explanation of the observed behavior of nickel-cadmium cells during voltage reversal. Constant current reversals using aerospace Ni-Cd cells showed that at rates of C/100 and temperatures of 20 C, a steady condition of constant pressure is achieved with continuous overdischarge. Results of a test employing a battery pack of thirteen 24 Ah cells at 10 C showed that: (1) no net evolution of H occurs in Ni-Cd cells during overdischarge, (2) as H pressure increases the rate of pressure rise decreases, and (3) after attaining pressure equilibrium at a given overdischarge rate, a pressure decrease is noted when the discharge is lowered. Other tests using varying overdischarge rates were examined and have resulted in the development of a laboratory cell with a safe overdischarge capability of C/20 which is three times as great as state-of-the-art Ni-Cd cells.

Ritterman, P. F.↗